Laserfiche WebLink
r <br />� <br />L <br />J <br />509 FELT OVER <br />METAL FLASHING <br />SHINGLE ROOF, U.N.O PER <br />CONTRACT <br />TYPICAL VALLEY FLASHING DETAIL <br />N.T.S. <br />3 TAB 25 YR SHINGLE ON APPROVED <br />UNDERLAYMENT ASTM D 226 OVER <br />ROOF SHEATHING SPECIFIED ON <br />NAILING SCHEDULE ROOF OVER <br />PRE-ENGINEERED ROOF TRUSSES @ <br />24" O.C. <br />12 <br />PITCH AS <br />PER <br />ELEV. HURRICANE STRAP PER <br />ROOF FRAMING PLAN <br />BRG. HGT. <br />,I <br />ALUM. DRIP EDGE <br />-- 2x6. FASCIA <br />VENTED ALUM. SOFFIT <br />SHEATHING & EXTERIOR FINISH <br />WINDOW FLASHING AS REQ'D <br />lx4 WINDOW TRIM <br />DBL.HEADER <br />TYPICAL WINDOW & SLIDING GLASS <br />DOOR Z FLASHING DETAIL <br />N.T.S. <br />OPTION - A <br />FLASHING <br />WOODEN <br />SHIM <br />SILL PLATE <br />SEE NOTE #2 <br />WALL SHEATHIN <br />G <br />G <br />NOTES: <br />1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) <br />2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE <br />3. INSTALL SILL FLASHING AS SHOWN ABOVE <br />4. INSTALL FLASHING AROUND REMAINING WINDOW UNIT <br />5. WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS <br />TYPICAL FLASHING DETAIL AT SILL PLATE <br />N.T.S. <br />TIE-IN WITH WEATHER RESISTIVE BARRIER: <br />1. INTEGRATE INSTALLATION OF WEATHER RESISTIVE BARRIER WITH <br />FLASHING TO FORM WATER SHEDDING LAPS <br />2. SCORE & FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO <br />ALLOW FOR FLASHING INSTALLATION <br />4. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER <br />5. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING <br />AND SEAL WITH WEATHER RESISTIVE BARRIER TAPE <br />FLASHING <br />TYPICA <br />N.T.S. <br />MECHANICALLY FASTEN AS <br />NECESSARY IN CORNERS <br />THROUGH FLASHING <br />WEATHER <br />RESISTIVE <br />BARRIER <br />TAPE -71 <br />WEATHER <br />RESISTIVE <br />BARRIER <br />SLOPE <br />s <br />t� <br />FLASHING <br />FORMED CAP <br />HOUSE WRAP <br />WIRE LATHE <br />CEMENT <br />PLASTER FINISH <br />CAP @LOW WALL <br />N.T.S. <br />EXTERIOR SHEATHING WALL COVERING <br />FOLD UP WEATHER 2014 FBRC SECTION R703 EXTERIOR COVERING <br />RESISTIVE BARRIER& EXTERIOR WALLS SHALL PROVIDE THE BUILIDNG WITH A WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE <br />TEMPORARILY SECURE <br />EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.8. THE EXTERIOR WALL <br />�Fs�s ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER AS <br />REQUIRED BY SECTION R7O3.2 AND A MEANS OF DRAINING TO THE EXTERIOR WALL THAT ENTERS THE ASSEMBLY. <br />PROTECTION AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY SHALL BE PROVIDED IN ACCORDANCE <br />WEATHER RESISTIVE WITH SECTION R702.7 OF THE CODE. <br />BARRIER <br />R703.2 WATER -RESISTIVE BARRIER <br />SILL PLATE F.PV. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM HOLES AND BREAKS, COMPLYING WITH ASTM D 226 FOR TYPE 1 <br />(SEE DETAIL B FELT OR OTHER APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />2 FOR OPTIONS) � EXTERIOR WALLS. SUCH FELT OR MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED <br />OVER THE LOWER LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT <br />LESS THAN 6 INCHES (152 MM). THE FELT OR OTHER APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF <br />CORNER PATCH WALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TO MEET THE <br />REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />R703.8 FLASHING <br />O APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING <br />FLASHING COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR <br />FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT <br />NOTES: COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND <br />1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE CONTRACTION, ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF <br />(MIN. 6" WIDE) SEALANT. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED <br />CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: <br />2. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS <br />3. MECHANICALLY FASTEN AS NECESSARY 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND <br />OR FLASHING DETAIL TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT <br />DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE <br />CEMENT <br />FOLD UP WEATHER <br />PLASTER FINISH <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />WIRE LATHE <br />HOUSE WRAP - <br />TO OVERLAP <br />FLASHING <br />EXTERIOR <br />SHEATHING <br />SILL PLATE <br />WALL PER PLAN <br />6" <br />RUN KICKOUT FLASHING 6' <br />PAST EDGE OF ROOF <br />TYPICAL ROOF TO WALL FLASHING DETAIL <br />5"x5" METAL FLASHING <br />w/TAR BETWEEN <br />FLASHING AND SHINGLES U.N.O. <br />SHINGLE, <br />U.N.O. PER <br />CONTRACT <br />TYPICAL ROOF TO WALL <br />FLASHING DETAIL <br />N.T.S. PLAN VIEW I N.T.S. <br />0 <br />u <br />wFgTyF _ <br />R <br />HOUSE WRAP - <br />WI RE LATHE - <br />DO NOT FLASH CEMENT <br />OVER BOTTOM PLASTER FINISH <br />NAILING FLANGE <br />HEAD FLASHING TIE-IN <br />INSTRUCTIONS: <br />NOTES: <br />1. CUT, FOLD UP & TEMPORARILY <br />SECURE WEATHER RESISTIVE 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) <br />BARRIER ABOVE HEADER TO <br />ALLOW FOR FLASHING 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW <br />INSTALLATION SILL PLATE <br />2. INSTALL HEAD FLASHING UNDER 3. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS <br />WEATHER RESISTIVE BARRIER <br />4. INSTALL FLASHING AND WEATHER RESISTIVE <br />3. FOLD WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS <br />BARRIER BACK OVER HEAD <br />FLASHING AND SEAL WITH TAPE <br />TYPICAL WINDOW FLASHING DETAIL <br />N.T.S. <br />(ASSEMBLED <br />WINDOW) <br />x <br />2 <br />z <br />O <br />z <br />G) <br />FLASHING <br />FLASHING <br />3-HEAD <br />SLOPE <br />`L <br />1-SILL <br />FLASHING <br />SHIM TO <br />PROVIDE SLOPE <br />HOUSE WRAP <br />WIRE LATHE <br />CEMENT <br />PLASTER FINISH <br />OR MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT <br />- <br />ADDRESSED IN THE FENESTRATION MANUFACTURER'S, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S <br />INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE <br />SILL OF EXTERIOR WINDOWS AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A <br />WIRE LATHE <br />MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE <br />CEMENT <br />BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OR <br />PLASTER FINISH <br />PROTECTION AT THE HEAD AND SIDES. <br />FLASHING <br />CEMENT <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. <br />PLASTER FINISH <br />HOUSE WRAP <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250„ OR FMA/AAMA/WDMA 300. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. <br />-FOLD UP WEATHER <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />BARRIER AND <br />4-�oo <br />N <br />coN <br />N <br />00 <br />3 <br />�L.LCo <br />� <br />O N <br />C <br />O QXo <br />C <br />co <br />3 <br />E 3 <br />a � <br />AA <br />g <br />ar=-o <br />CT, <br />a <br />av0 <br />wCTz <br />Za Wes' <br />� f Z <br />F bD� O OmN <br />"kv� oa <br />WZo= <br />tt <br />❑ <br />�ZO <br />Nyma <br />w��J <br />pO\Q pW„' <br />o� O <br />N <br />O <br />� <br />go <br />zgA��Zov�° <br />aLy <br />O 0 <br />W � <br />o= <br />Z <br />W <br />0P�� <br />v ai <br />Q <br />a <br />L U <br />LU <br />W a, <br />U ❑ <br />o�73 <br />U <br />° <br />� <br />N N[O�'JPE3SQ3'A1MAA <br />LL <br />W <br />J <br />Q1 <br />LO <br />Q (N 0) <br />Nr LO <br />W N <br />Z 1 <br />LO <br />� � o <br />Q � o <br />z O <br />z z o <br />W Q <br />J �M <br />W <br />VJ <br />LU <br />SECURE 5. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME <br />> title: <br />CONSTRUCTION. W <br />FLASHING DETAILS <br />CJ <br />z <br />WEATHER BARRIER 6. AT WALL AND ROOF INTERSECTIONS. o <br />project no. 2017407 <br />7. AT BUILT-IN GUTTERS. <br />FLASHING @ <br />WALL OPENING <br />N.T.S. <br />W checked: AB/EC <br />0 <br />drawn: <br />r <br />date: 07-06-17 <br />N scale: AS NOTED <br />0 <br />z <br />IL WP1 <br />0 <br />U <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />