My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6515 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6515 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:28:18 PM
Creation date
2/19/2025 12:54:46 PM
Metadata
Fields
Template:
Building Plans
Street #
6515
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18788
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - - - r - - - - - - - - - - I <br />I I <br />I I <br />I I <br />s <br />L— — — — — — — — — — — — — — — J <br />2nd FLOOR ELECTRICAL PLAN <br />1 /4" = 11 <br />-0" <br />NFPA 70 <br />ADD GFCI PROTECTION TO RECEPTACLES IN LAUNDRY ROOMS AND UTILITY ROOMS OF DWELLINGS <br />WHERE INSTALLED WITHIN 6OF THE OUTSIDE EDGE OF A SINK. THIS WOULD INCLUDE THE <br />RECEPTACLE INSTALLED FOR A WASHING MACHINE. <br />RECEPTACLE OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A RANGE OR SINK TO <br />FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24'.'. THE WIDTH OF THE SINK OR RANGE IS NOT <br />TO BE INCLUDED IN THE SPACING OF THE OUTLETS UNLESS THE DISTANCE FROM THE SINK OR <br />RANGE IS GREATER THAN 12" FOR STRAIGHT COUNTER TOPS AND 18" FOR SINKS AND RANGES <br />INSTALLED IN CORNER COUNTERS. <br />Typical 150-200 Amp Electrical Riser Diagram <br />POWER CO. FEE <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METERV-210 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />DISCLAIMER <br />IT IS THE CONTRACTOR/SUB-CONTRACTORS RESPONSIBILITY TO REVIEW ALL <br />INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF <br />CONSTRUCTION. B&A DESIGN STUDIO, INC. & FLORIDA DESIGN SOLUTIONS INC. <br />IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR <br />CUSTOM CHANGES MISSED AND NOT REPORTED TO B&A DESIGN STUDIO, INC. & <br />FLORIDA DESIGN SOLUTIONS INC. PRIOR TO CONSTRUCTION. <br />NO EXCEPTIONS. <br />GENERAL NOTES <br />1. FAN, PHONE, & CAN LOCATIONS PER CONTRACT <br />R314.2 / R315.1 <br />2. ALL SMOKE/CARBON MONOXIDE DETECTORS TO BE INSTALLED PER <br />2014 FBRC REFERENCED NFPA 72. SMOKE DETECTORS SHALL BE <br />HARDWIRED INTO AN AC ELECTRICAL POWER SOURCE AND SHALL BE <br />EQUIPPED WITH A MONITORED BATTERY BACKUP AND SHALL BE <br />INTERCONNECTED. <br />3, ARCH FAULT BREAKERS: ALL BRANCH CIRCUITS SERVING BEDROOMS, <br />FAMILY ROOMS, HALLWAYS, AND DINING ROOMS SHALL BE PROTECTED <br />BY ARCH FAULT BREAKERS, PER 2014 FRBC. <br />(REFER TO CHAPTERS 34 - 43) <br />4. TAMPER -RESISTANT "TR" RECEPTACLES: ALL 125-VOLT, 15 & 20 <br />AMPERE ELECTICAL OUTLETS (RECEPTACLES) IN LIVING ROOM <br />AREAS, BATHROOMS, KITCHEN, GARAGE, LAUNDRY ROOM, AND <br />EXTERIOR LOCATIONS MUST BE "TAMPER -RESISTANT' PER 2014 FRBC. <br />(REFER TO CHAPTERS 34 - 43) <br />5. ALL ELECTRICAL WORK AND APPLIANCES SHALL CONFORM TO <br />2014 FBRC REFERENCED NFPA 70 <br />6. EXCEPTIONS FROM GFI REQUIREMENTS SHALL BE PERMITTED <br />PROVIDED LOCATION WHERE EXCEPTION IS DESIRED IS ALLOWED <br />PER 2014 FBRC REFERENCED NFPA 70 <br />7. UNLESS OTHERWISE INDICATED OR GOVERNED BY CODE, INSTALL <br />SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS <br />ABOVE FINISH FLOOR. <br />ELECTRICAL DEVICES ABOVE FIN. FLR. <br />SWITCHES AND WALL OUTLETS OVER COUNTERS <br />48" TO C.L. <br />REMAINING SWITCHES <br />48" TO C.L. <br />WALL OUTLETS <br />12" TO C.L. <br />TELEPHONE OUTLETS <br />12" TO C.L. <br />TELEVISION OUTLETS <br />12" TO C.L. <br />EXTERIOR GFI'S <br />12" TO C.L. <br />GARAGE GFI'S (ABOVE GARAGE FLOOR) <br />48" TO C.L. <br />THERMOSTAT <br />54" TO C.L. <br />DOOR BELL CHIMES <br />84" TO C.L. <br />DOOR BELL BUTTON <br />LEVEL W/ DOOR HANDLE <br />KITCHEN HOOD FAN "WHIP" <br />66" TO C.L. <br />KITCHEN WALL HUNG MICROWAVE RECEPTACLE <br />76" TO C.L. <br />KITCHEN DISHWASHER RECEPTACLE <br />UNDER SINK <br />KITCHEN RANGE <br />24" TO C.L. <br />KITCHEN REFRIGERATOR <br />48" TO C.L. <br />WASHER/DRYER OUTLET <br />36" TO C.L. <br />HOLLYWOOD LIGHTS <br />84" TO C.L. <br />C.L. = CENTER LINE <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />wF WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />Id DISPOSAL <br />WALL SWITCH <br />s THREE-WAY SWITCH <br />$4 FOUR-WAY SWITCH <br />DIMMER SWITCH <br />OM MOTION DETECTOR SWITCH (OPTIONAL) <br />sP PRE -WIRED SPEAKER <br />DO RECESSED LIGHT FIXTURE <br />DO VF RECESSED LIGHT FIXTURE - VAPOR PROOF <br />OO LEo LED LIGHT FIXTURE <br />*-O MONO POINT TRACK HEAD (OPTIONAL) <br />{�} <br />PENDANT FIXTURE <br />SURFACE MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />FLUORESCENT LIGHT FIXTURE <br />WALL MOUNTED STRIP LIGHT <br />--' UNDERCABINET LIGHTING (OPTIONAL) <br />WALL SCONCE <br />O <br />EXHAUST FAN <br />EXHAUST FAN & LIGHT COMBO <br />OUTLET FOR GARAGE DOOR OPENER <br />SOFFIT OUTLET (OPTIONAL) <br />CHIMES <br />r•� <br />CHIMES <br />4 <br />PUSHBUTTON SWITCH <br />O <br />CARBON MONOXIDE/SMOKE DETECTOR <br />TELEPHONE OUTLET PREWIRE <br />T <br />TELEVISION OUTLET PREWIRE <br />4 <br />THERMOSTAT <br />L� <br />ELECTRIC METER <br />0 <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />EZEZ <br />SECURITYSYSTEM KEYPAD <br />>)e� <br />PRE -WIRE FOR CEILING FAN <br />xFAN/LIGHT COMBO <br />vSECURITY/FLOOD LIGHTS <br />GAS METER <br />JB JUNCTION BOX <br />tio E <br />�N ti - O O <br />N00N V <br />CN a7 <br />.r O <br />sXr�yj <br />>�o� <br />C <br />tit <br />C <br />Q X <br />cc 0 <br />R <br />z <br />sa <br />is.r '•` <br />w <br />a r <br />W <br />z <br />2 LU <br />z <br />W °°a O aOt `^ <br />ono�i~ <br />Zox <br />AGO <br />�m� O <br />0Ul— <br />EW <br />El <br />LL Z� <br />om <br />ZZo - a <br />N <br />�z <br />WPO cop <br />z UJ <br />5 � <br />zIn o <br />uj <br />W GIN :pN <br />mow <br />W Q�L) C'� <br />b� <br />LiP�F- <br />Q <br />I <br />��LLO <br />4e04 Uri <br />o <br />N 1LI <br />❑ <br />U <br />N N[O�'tJNHSQ� MMdA <br />w <br />�d <br />z <br />W <br />z <br />z <br />z <br />LL <br />o W <br />w <br />J <br />F _ <br />0 <br />U3 <br />z <br />w <br />i <br />U <br />O <br />W <br />W <br />w <br />x <br />z <br />z <br />U <br />F_ <br />r- <br />w <br />W <br />x <br />0 <br />w <br />x <br />0 <br />0 <br />x <br />z <br />r <br />a <br />U <br />N <br />5, title: <br />w <br />2nd FLOOR <br />z <br />ELECTRICAL PLAN <br />S <br />Z project no. 2017407 <br />W checked: AB/EC <br />0 <br />drawn: <br />Ln I date: 07-06-17 <br />N scale: AS SHOWN <br />2 <br />} <br />01 <br />E20 <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />
The URL can be used to link to this page
Your browser does not support the video tag.