My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6515 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6515 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:28:18 PM
Creation date
2/19/2025 12:54:46 PM
Metadata
Fields
Template:
Building Plans
Street #
6515
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18788
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y"^"I <br />GFI <br />._. u_ <br />N <br />�I <br />1 <br />�-i <br />GFI <br />H <br />FI <br />RECEPT. FOR \ <br />IRRIGATION. <br />3 CAR TANDEM GARAGE \ <br />9'-4" CLG. <br />METER PRE -WIRE \\ <br />W ONLY <br />4FT. / <br />I_.. <br />ELECTRICIAN TO VERIFY LIGHT LOCATION <br />I- WITH GARAGE DOOR OPEN POSITION. <br />m BEFORE INSTALLING. <br />`A i I <br />R <br />GARAGE DOOR, <br />RECEPTACLE AND <br />1 OVERHEAD LIGHTS TO <br />BE GFCI PROTECTED <br />I I <br />T. BREAKFAST <br />I 9'-4" CLG. <br />3 i\ <br />GFI <br />PREWIREP GFI +39' <br />ONLY // FAMILY � +39 <br />9'-4" CLG. I GFI / <br />i $ +3911 / <br />I GF <br />GFI$ li <br />GARBAGE a� D , - <br />- DISPOSAL ii"GFI <br />WH <br />GFI (9= <br />+42" <br />J <br />CHIMES <br />LAUNDRY <br />9'-4" CLG. <br />220V <br />_ __ _r F4- <br />� ��_F � GFI Q+42„ <br />SWITCH TO <br />LGHT. ABV <br />/" _ ............... <br />PREWARE� <br />ONLY P\_ <br />l <br />LIBRARY O <br />9'-4" CLG. <br />�^ C <br />7PH O <br />W€ I <br />I 0 GFI <br />KITCHEN <br />9'41 CLG. I _. H <br />I $ <br />l I PENDANT! <br />NT! <br />t LIGHT \ � IGFI <br />1 <br />�p REFRFG. -if _._.. GFI <br />I <br />f <br />3 l <br />DINING <br />Q \ 9'-4" CLG. <br />. ACLG. <br />MOUNTED <br />UNDER STAIRS <br />NFPA 70 <br />ADD GFCI PROTECTION TO RECEPTACLES IN LAUNDRY ROOMS AND UTILITY ROOMS OF DWELLINGS <br />WHERE INSTALLED WITHIN 6' OF THE OUTSIDE EDGE OF A SINK. THIS WOULD INCLUDE THE <br />RECEPTACLE INSTALLED FOR A WASHING MACHINE. <br />RECEPTACLE OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A RANGE OR SINK TO <br />FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24". THE WIDTH OF THE SINK OR RANGE IS NOT <br />TO BE INCLUDED IN THE SPACING OF THE OUTLETS UNLESS THE DISTANCE FROM THE SINK OR <br />RANGE IS GREATER THAN 12" FOR STRAIGHT COUNTER TOPS AND 18" FOR SINKS AND RANGES <br />INSTALLED IN CORNER COUNTERS. <br />Typical 150-200 Amp Electrical Riser Diagram <br />200A INDOOR PANEL <br />CENTER <br />LIVING I METER <br />9'-4" CLG. MAIN <br />AL <br />O <br />...... ,. .. t ..,.....-,..a._._.d �...m._. .a�.„ �i z <br />" - — 200 amp <br />150 amp <br />FOYER _ Disconnect <br />WP \ 9'-4" CLG. a <br />GFI <br />€ l `...E� POWER CO. FEED <br />LIJ <br />DB <br />COVERED PORCH I I€ <br />9'-4" CLG. ro) � I <br />�I <br />ELECTRICAL FIRST PLAN ELEVATION "A" <br />#15 copper to lights & outlets <br />#12 copper to 20 amp dds <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />DISCLAIMER <br />IT IS THE CONTRACTOR/SUB-CONTRACTORS RESPONSIBILITY TO REVIEWALL <br />INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF <br />CONSTRUCTION. B&A DESIGN STUDIO, INC. & FLORIDA DESIGN SOLUTIONS INC. <br />IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR <br />CUSTOM CHANGES MISSED AND NOT REPORTED TO B&A DESIGN STUDIO, INC. & <br />FLORIDA DESIGN SOLUTIONS INC. PRIOR TO CONSTRUCTION. <br />NO EXCEPTIONS. <br />GENERAL NOTES <br />1. FAN, PHONE, & CATV LOCATIONS PER CONTRACT <br />R314.2 / R315.1 <br />2. ALL SMOKE/CARBON MONOXIDE DETECTORS TO BE INSTALLED PER <br />2014 FBRC REFERENCED NFPA 72. SMOKE DETECTORS SHALL BE <br />HARDWIRED INTO AN AC ELECTRICAL POWER SOURCE AND SHALL BE <br />EQUIPPED WITH A MONITORED BATTERY BACKUP AND SHALL BE <br />INTERCONNECTED. <br />3. ARCH FAULT BREAKERS: ALL BRANCH CIRCUITS SERVING BEDROOMS, <br />FAMILY ROOMS, HALLWAYS, AND DINING ROOMS SHALL BE PROTECTED <br />BY ARCH FAULT BREAKERS, PER 2014 FRBC. <br />(REFER TO CHAPTERS 34 - 43) <br />4. TAMPER -RESISTANT "TR" RECEPTACLES: ALL 125-VOLT, 15 & 20 <br />AMPERE ELECTICAL OUTLETS (RECEPTACLES) IN LIVING ROOM <br />AREAS, BATHROOMS, KITCHEN, GARAGE, LAUNDRY ROOM, AND <br />EXTERIOR LOCATIONS MUST BE "TAMPER -RESISTANT" PER 2014 FRBC. <br />(REFER TO CHAPTERS 34 - 43) <br />5. ALL ELECTRICAL WORK AND APPLIANCES SHALL CONFORM TO <br />2014 FBRC REFERENCED NFPA 70 <br />6. EXCEPTIONS FROM GFI REQUIREMENTS SHALL BE PERMITTED <br />PROVIDED LOCATION WHERE EXCEPTION IS DESIRED IS ALLOWED <br />PER 2014 FBRC REFERENCED NFPA 70 <br />7. UNLESS OTHERWISE INDICATED OR GOVERNED BY CODE, INSTALL <br />SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS <br />ABOVE FINISH FLOOR. <br />ELECTRICAL DEVICES ABOVE FIN. FLR. <br />SWITCHES AND WALL OUTLETS OVER COUNTERS 48" TO C.L. <br />REMAINING SWITCHES 48" TO C.L. <br />WALL OUTLETS 12" TO C.L. <br />TELEPHONE OUTLETS 12" TO C.L. <br />TELEVISION OUTLETS 12" TO C.L. <br />EXTERIOR GFI'S 12" TO C.L. <br />GARAGE GFI'S (ABOVE GARAGE FLOOR) 48" TO C.L. <br />THERMOSTAT 54" TO C.L. <br />DOOR BELL CHIMES 84" TO C.L. <br />DOOR BELL BUTTON LEVEL W/ DOOR HANDLE <br />KITCHEN HOOD FAN "WHIP" 66" TO C.L. <br />KITCHEN WALL HUNG MICROWAVE RECEPTACLE 76" TO C.L. <br />KITCHEN DISHWASHER RECEPTACLE UNDER SINK <br />KITCHEN RANGE 24" TO C.L. <br />KITCHEN REFRIGERATOR 48" TO C.L. <br />WASHER/DRYER OUTLET 36" TO C.L. <br />HOLLYWOOD LIGHTS 84" TO C.L. <br />C.L. = CENTER LINE <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />wP WEATHERPROOF DUPLEX OUTLET <br />GFI GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />>� HALF -SWITCHED DUPLEX OUTLET <br />DUPLEX OUTLET IN FLOOR <br />22oV 220 VOLT OUTLET <br />I DISPOSAL <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />$¢ FOUR-WAY SWITCH <br />$D DIMMER SWITCH <br />@M MOTION DETECTOR SWITCH (OPTIONAL) <br />sP PRE -WIRED SPEAKER <br />0 RECESSED LIGHT FIXTURE <br />OvP RECESSED LIGHT FIXTURE- VAPOR PROOF <br />OLED LED LIGHT FIXTURE <br />*0 MONO POINT TRACK HEAD (OPTIONAL) <br />PENDANT FIXTURE <br />SURFACE MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />FLUORESCENT LIGHT FIXTURE <br />WALL MOUNTED STRIP LIGHT <br />UNDERCABINET LIGHTING (OPTIONAL) <br />WALL SCONCE <br />4 EXHAUST FAN <br />EXHAUST FAN & LIGHT COMBO <br />OUTLET FOR GARAGE DOOR OPENER <br />SOFFIT OUTLET (OPTIONAL) <br />CHIMES <br />�•� CHIMES <br />4 PUSHBUTTON SWITCH <br />O CARBON MONOXIDEISMOKE DETECTOR <br />TELEPHONE OUTLET PREWIRE <br />T TELEVISION OUTLET PREWIRE <br />THERMOSTAT <br />[� ELECTRIC METER <br />0 ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SECURITYSYSTEM KEYPAD <br />xPRE -WIRE FOR CEILING FAN <br />xFAN/LIGHT COMBO <br />SECURITY/FLOOD LIGHTS <br />GAS METER <br />JB JUNCTION BOX <br />V�o o <br />00 <br />N N U <br />�CV) Cna7 O_ <br />CO 00 <br />® ?' <br />r~ n = <br />�4t c <br />tio-r-xIm <br />n <br />cu <br />CD co w <br />l <br />�$ <br />e,:mI <br />z❑ ", W <br />w3az z a <br />❑LLI <br />a Zcr F 01 Q IY:N <br />❑ Q <br />wz <br />c00 a t w <br />W6ZZ oo ❑ r <br />0E5q w <br />0u,9� <br />a =o �¢ VS c <br />�yma z p op,d P; N <br />z Z LLW M -NO T <br />C9Zo� Zz o > <br />w��n� (�� �r.� 0 <br />�PoW W � <br />O ❑ LC �wry <br />H U S m d U n a Q <br />m N Z° IICC O tt� QQU w C <br />F=u ❑ <br />OfU � <br />N I10D'DN3SQd'Mh1M <br />I— <br />LL <br />W <br />VI <br />Q <br />N <br />0) <br />W <br />CN <br />Z <br />1 <br />LO <br />0 <br />Q <br />o <br />Z <br />0 <br />O <br />Z <br />W <br />Z <br />Q <br />0 <br />J <br />� <br />� <br />W <br />V <br />V <br />title: <br />W <br />1 st FLOOR <br />CK ELECTRICAL PLAN <br />Z project no. 2017407 <br />LU checked: AB/EC <br />drawn: <br />date: 07-06-17 <br />N scale: AS SHOWN <br />0 <br />H <br />I <br />U <br />} <br />0 El0 <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />
The URL can be used to link to this page
Your browser does not support the video tag.