— — — — — — — — — — — — — — <br />I I <br />L— — — — — — — — — — — — — — — J <br />ARCHITECTURAL <br />SHINGLES <br />6" BANDING AT <br />EAVE <br />OIL 19'-4 7/8" <br />HEEL HGT. <br />18'-8 7/&' — <br />BRG. HGT. — <br />17'-10 3/4" — <br />WDW. HGT. <br />OIL 10'-8 3/4" <br />2nd FLR <br />OIL— <br />BRG. HGT. <br />OIL 8'-0" <br />WDW.. HGT. <br />6" BANDING AT <br />EAVE <br />TEXTURED CEMENT <br />PLASTER FINISH <br />0'-0" - <br />FIN. FLR. <br />12 <br />6 <br />FRONT- ELEVATION <br />1 /4" = 1'-0" <br />HANDRAIL <br />ROOF CRITERIA EXTERIOR PLASTER <br />12" OVERHANG U.N.O. / PLUMB CUT FASCIA / ROOF PITCH PER R703.6 EXTERIOR PLASTER - <br />ELEVATION / SHINGLES U.N.O. INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH <br />ASTM C 926 AND ASTM C 1063 AND THE PROVISIONS OF THIS CODE. <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS <br />RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS R703.6.1 LATHE. <br />MANUFACTURER. ALL LATH AND LATH ATTACHMENTS SHALL BE OF <br />CORROSION -RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT LATH SHALL BE ATTACHED WITH 1 1/2-INCH-LONG (38 MM), 11 GAGE <br />GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND NAILS HAVING A 7/16-INCH (11.1 MM) HEAD, OR 7/8-INCHLONG (22.2 MM), <br />AROUND ROOF OPENINGS. 16 GAGE STAPLES, SPACED AT NO MORE THAN 6 INCHES (152 MM), OR AS <br />STEP FLASHING SHALL BE USED ON ALL ROOF TO WALL INTERSECTIONS OTHERWISE APPROVED. <br />ON RAKES. <br />R703.6.2 PLASTER. <br />ATTENTION CONTRACTORS ALL PENETRATIONS THROUGH ROOF ARE PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS <br />TO BE LOCATED ON REAR OR IF NECESSARY ON THE SIDE OF THE ROOF THAN THREE COATS WHEN APPLIED OVER METAL LATH OR WIRE LATH <br />BEHIND THE FRONT FACADE ZONE. AND SHALL BE NOT LESS THAN TWO COATS WHEN APPLIED OVER <br />_ MASONRY, CONCRETE, PRESSURE -PRESERVATIVE TREATED WOOD OR <br />ASPHALT SHINGLES (IF APPLICABLE) : DECAY -RESISTANT WOOD AS SPECIFIED IN SECTION R317.1 OR GYPSUM <br />1. WIND RESISTANCE OF ASPHALT SHINGLES. -ASPHALT SHINGLES SHALL BACKING. IF THE PLASTER SURFACE IS COMPLETELY COVERED BY <br />BE INSTALLED IN ACCORDANCE WITH SECTION R905.2.6AND R905.2.6.1. VENEER OR OTHER FACING MATERIAL OR IS COMPLETELY CONCEALED, <br />2. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF PLASTER APPLICATION NEED BE ONLY TWO COATS, PROVIDED THE <br />TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER. TOTAL THICKNESS IS AS SET FORTH IN TABLE R702.1(1). <br />FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL <br />(2:12) AND LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL ON WOOD -FRAME CONSTRUCTION WITH AN ON -GRADE FLOOR SLAB <br />A (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING WITH ASTM D 226, SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED TO COVER, BUT NOT <br />TYPE I OR TYPE II, ASTM D 4869, TYPE I OR TYPE II OR ASTM D 6757 IS EXTEND BELOW, LATH, PAPER AND SCREED. <br />3A REQUIRED IN ACCORDANCE WITH SECTION R905.2.7. <br />FOR ROOF SLOPES FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL THE PROPORTION OF AGGREGATE TO CEMENTITIOUS MATERIALS SHALL <br />(4:12) AND GREATER, ONE LAYER OF UNDERLAYMENT COMPLYING WITH BE AS SET FORTH IN TABLE R702.1(3). <br />ASTM D 226, TYPE II, ASTM D 4869, TYPE IV OR ASTM D 6757 IS REQUIRED IN <br />ACCORDANCE WITH SECTION R905.2.7. R703.6.2.1 WEEP SCREEDS. <br />3. AS AN ALTERNATIVE, THE ENTIRE ROOF DECK SHALL BE COVERED WITH A MINIMUM 0.019-INCH (0.5 MM) (NO.26 GALVANIZED SHEET GAGE), <br />16" BANDING AT AN APPROVED SELF -ADHERING POLYMER MODIFIED BITUMEN SHEET CORROSION -RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED, <br />FLOOR TRUSS MEETING ASTM D 1970 OR AN APPROVED SELF -ADHERING SYNTHETIC WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3 1/2 INCHES (89 <br />CONTROL JOINT UNDERLAYMENT INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S MM) SHALL BE AT OR BELOW THE FOUNDATION PLATE LINE ON <br />INSTALLATION INSTRUCTIONS EXTERIOR STUD WALLS IN ACCORDANCE WITH ASM C 926. THE WEEP <br />AT BOTTOM OF SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES (102 MM) ABOVE THE <br />BANDING CLAY AND CONCRETE TILE (IF APPLICABLE) : EARTH OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND SHALL BE OF A <br />THE INSTALLATION OF CLAY AND CONCRETE TILE PER F.B.C.R. - TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR <br />5TH EDITION (2014) R905.3 SHALL BE IN ACCORDANCE WITH OF THE BUILDING. THE WEATHER -RESISTANT BARRIER SHALL LAP THE <br />THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND <br />RECOMMENDATIONS OF FRSA/TRI FLORIDA HIGH WIND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. <br />CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL, <br />FIFTH EDITION WHERE THE VASD IS DETERMINED IN R703.6.3 WATER -RESISTIVE BARRIES. <br />ACCORDANCE WITH SECTION R301.2.1.3 OR THE WATER -RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN <br />RECOMMENDATIONS OF RAS 118, 119 OR 120. SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED SHEATHING, <br />REQUIRED UNDERLAYMENT PER F.B.C.R. - 5TH EDITION (2014) SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH <br />R905.3.3 SHALL CONFORM WITH ASTM D 226, TYPE II; ASTM D 2626, A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D <br />TYPE II; OR ASTM D 1970 OR ASTM D 6380, CLASS M MINERAL PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY <br />SURFACED ROLL ROOFING AND SHALL BE INSTALLED IN <br />iv SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE <br />ACCORDANCE WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION R703.8) <br />AND CLAY ROOF TILE INSTALLATION MANUAL, FIFTH EDITION INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS DIRECTED <br />BANDING AT BASE WHERE THE VASD IS DETERMINED IN ACCORDANCE WITH BETWEEN THE LAYERS. <br />SECTION R301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118, 119 OR 120. <br />R312.2.1 Window sills. <br />In dwelling units, where the opening of an operable window is located more than 72 inches <br />(1829 mm) above the finished grade or surface below, the lowest part of the clear opening of <br />BANDING WITH the window shall be a minimum of 24 inches (610 mm) above the finished floor of the room in <br />SMOOTH TEXTURED which the window is located. Operable sections of windows shall not permit openings that <br />CEMENT PLASTER allow passage of a 4 inch (102 mm) diameter sphere where such openings are located within <br />FINISH 24 inches (610 mm) of the finished floor. <br />ARCHITECTURAL <br />SHINGLES <br />18'-4 3/4" <br />BRG. HGT. @ PORCH <br />RAILINGS SHALL NOT <br />ALLOW PASSAGE OF A <br />4" DIAMETER SPHERE <br />9'-4" <br />CMU BRG. HGT. @ PORCH <br />TEXTURED CEMENT <br />PLASTER FINISH <br />8/8 LITES AT 4' WIDE WINDOWS <br />6/6 LITES AT 3' WIDE WINDOWS <br />FRONTS WINDOWS AND SIDE WINDOWS <br />THAT OCUPPY THE SAME INTERIOR <br />1 <br />SPACE TO RECIEVE MULLIONS. <br />1 <br />1 <br />1 <br />1 <br />3" PAST WINDOW OPNG <br />1 <br />1 <br />TYP. <br />1 <br />iHDR. <br />BANDING AT FIRST FLOOR ONLY <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />SMOOTH BANDING <br />A WINDOW DETAIL. <br />1 /2" = 1'-0" <br />DISCLAIMER <br />�i oOt E <br />j} <br />U <br />NCDN CA <br />M a) 'M <br />t+iV.1 <br />• <br />CA <br />�LLL�0 <br />~O ^ rn <br />C <br />'~ OL X 'tn <br />C:) ca 45 CD <br />t6 <br />.z <br />M <br />. Z <br />i <br />� UJ <br />�❑ <br />oc650 <br />t� <br />a00 <br />� <br />ILU <br />J J� z �/ i'IE(I� <br />Q Z � an C11 /� W <br />0 <br />\� <br />W <br />4a p W U ¢';D w <br />r b # Q <br />O U <br />rZ <br />W W O w <br />� U ❑ <br />W 0 <br />O�'> <br />U � <br />N 3YOD'DN3SQ3'MMM � <br />aw <br />u <br />14" X LENGTH OF WINDOW <br />LOUVER SHUTTER <br />IT IS THE CONTRACTOR/SUB-CONTRACTORS RESPONSIBILITY TO REVIEWALL <br />INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF <br />CONSTRUCTION. B&A DESIGN STUDIO, INC. & FLORIDA DESIGN SOLUTIONS INC. <br />IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR <br />CUSTOM CHANGES MISSED AND NOT REPORTED TO B&A DESIGN STUDIO, INC. & <br />FLORIDA DESIGN SOLUTIONS INC. PRIOR TO CONSTRUCTION. <br />NO EXCEPTIONS. <br />I- <br />U_ <br />W <br />J <br />1 <br />LO <br />Q <br />N <br />W <br />N <br />Q <br />� <br />1 <br />— <br />Lo <br />O <br />Q <br />O <br />Z <br />Q <br />1 <br />O <br />Z <br />W <br />Z <br />Q <br />0 <br />J <br />� <br />� <br />W <br />J <br />U) <br />title: <br />ELEVATIONS <br />Z <br />project no. <br />o <br />checked: <br />m <br />drawn: <br />date: <br />Ni <br />Scale: <br />I <br />0 <br />} <br />a <br />0 <br />2017407 <br />AB/EC <br />07-06-17 <br />AS SHOWN <br />3A <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />