Laserfiche WebLink
— — — — — — — — — — — — — — — <br />I I <br />L — — — — — — — — — — — — — — — J <br />RAILINGS SHALL NOT - <br />ALLOW PASSAGE OF A <br />4" DIAMETER SPHERE <br />ARCHITECTURAL <br />SHINGLES <br />19'-4 7/8" <br />HEEL HGT. <br />18'-8 7/8" <br />BRG. HGT. <br />17'-10 3/4" <br />WDW. HGT. <br />12 <br />6 <br />1 x 12 TRIM <br />10'-8 3/4" BOARD <br />2nd FLR <br />9'-4" <br />BRG. HGT. <br />WDW.. HGT. <br />0'-0" <br />FIN. FLR. <br />ARCHITECTURAL <br />SHINGLES <br />TEXTURED CEMENT <br />PLASTER FINISH <br />TEXTURED CEMENT <br />PLASTER FINISH <br />REAR ELEVATION <br />1 /411 = 1'-01 <br />' <br />12 <br />6�/ <br />LEFT ELEVATION <br />1 /4" = 1'-0" <br />12 <br />6 I/ <br />SLOPE GRADE SO <br />THAT THE FOUNDATION <br />OF BUILDING IS MAX. <br />8" ABV. GRADE @ REAR <br />12 <br />`3 <br />nft.— — <br />ROOF CRITERIA <br />12" OVERHANG U.N.O. / PLUMB CUT FASCIA / ROOF PITCH PER <br />ELEVATION /SHINGLES U.N.O. <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE CONTRACTORS <br />RESPONSIBILITY TO VERIFY ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT <br />GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND <br />AROUND ROOF OPENINGS. <br />STEP FLASHING SHALL BE USED ON ALL ROOF TO WALL INTERSECTIONS <br />ON RAKES. <br />ATTENTION CONTRACTORS ALL PENETRATIONS THROUGH ROOF ARE <br />TO BE LOCATED ON REAR OR IF NECESSARY ON THE SIDE OF THE ROOF <br />BEHIND THE FRONT FACADE ZONE. <br />ASPHALT SHINGLES (IF APPLICABLE) : <br />1. WIND RESISTANCE OF ASPHALT SHINGLES. - ASPHALT SHINGLES SHALL <br />BE INSTALLED IN ACCORDANCE WITH SECTION R905.2.6AND R905.2.6.1. <br />2. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF <br />TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER. <br />FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL <br />(2:12) AND LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL <br />(4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING WITH ASTM D 226, <br />TYPE I OR TYPE II, ASTM D 4869, TYPE I OR TYPE II OR ASTM D 6757 IS <br />REQUIRED IN ACCORDANCE WITH SECTION R905.2.7. <br />FOR ROOF SLOPES FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL <br />(4:12) AND GREATER, ONE LAYER OF UNDERLAYMENT COMPLYING WITH <br />ASTM D 226, TYPE II, ASTM D 4869, TYPE IV OR ASTM D 6757 IS REQUIRED IN <br />ACCORDANCE WITH SECTION R905.2.7. <br />3. AS AN ALTERNATIVE, THE ENTIRE ROOF DECK SHALL BE COVERED WITH <br />AN APPROVED SELF -ADHERING POLYMER MODIFIED BITUMEN SHEET <br />MEETING ASTM D 1970 OR AN APPROVED SELF -ADHERING SYNTHETIC <br />UNDERLAYMENT INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS <br />EXTERIOR PLASTER <br />R703.6 EXTERIOR PLASTER. <br />INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH <br />ASTM C 926 AND ASTM C 1063 AND THE PROVISIONS OF THIS CODE. <br />R703.6.1 LATHE. <br />ALL LATH AND LATH ATTACHMENTS SHALL BE OF <br />CORROSION -RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE <br />LATH SHALL BE ATTACHED WITH 1 1/2-INCH-LONG (38 MM), 11 GAGE <br />NAILS HAVING A 7116-INCH (11.1 MM) HEAD, OR 7/8-INCHLONG (22.2 MM), <br />16 GAGE STAPLES, SPACED AT NO MORE THAN 6 INCHES (152 MM), OR AS <br />OTHERWISE APPROVED. <br />R703.6.2 PLASTER. <br />PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS <br />THAN THREE COATS WHEN APPLIED OVER METAL LATH OR WIRE LATH <br />AND SHALL BE NOT LESS THAN TWO COATS WHEN APPLIED OVER <br />MASONRY, CONCRETE, PRESSURE -PRESERVATIVE TREATED WOOD OR <br />DECAY -RESISTANT WOOD AS SPECIFIED IN SECTION R317.1 OR GYPSUM <br />BACKING. IF THE PLASTER SURFACE IS COMPLETELY COVERED BY <br />VENEER OR OTHER FACING MATERIAL OR IS COMPLETELY CONCEALED, <br />PLASTER APPLICATION NEED BE ONLY TWO COATS, PROVIDED THE <br />TOTAL THICKNESS IS AS SET FORTH IN TABLE R702.1(1). <br />ON WOOD -FRAME CONSTRUCTION WITH AN ON -GRADE FLOOR SLAB <br />SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED TO COVER, BUT NOT <br />EXTEND BELOW, LATH, PAPER AND SCREED. <br />THE PROPORTION OF AGGREGATE TO CEMENTITIOUS MATERIALS SHALL <br />BE AS SET FORTH IN TABLE R702.1(3). <br />R703.6.2.1 WEEP SCREEDS. <br />A MINIMUM 0.019-INCH (0.5 MM) (NO.26 GALVANIZED SHEET GAGE), <br />CORROSION -RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED, <br />WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 31/2 INCHES (89 <br />MM) SHALL BE AT OR BELOW THE FOUNDATION PLATE LINE ON <br />EXTERIOR STUD WALLS IN ACCORDANCE WITH ASM C 926. THE WEEP <br />SCREED SHALL BE PLACED A MINIMUM OF 4INCHES (102 MM) ABOVE THE <br />CLAY AND CONCRETE TILE (IF APPLICABLE) : <br />EARTH OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND SHALL BE OF A <br />THE INSTALLATION OF CLAY AND CONCRETE TILE PER F.B.C.R. - <br />TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR <br />5TH EDITION (2014) R905.3 SHALL BE IN ACCORDANCE WITH <br />OF THE BUILDING. THE WEATHER -RESISTANT BARRIER SHALL LAP THE <br />THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR <br />ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND <br />RECOMMENDATIONS OF FRSA/TRI FLORIDA HIGH WIND <br />TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. <br />CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL, <br />FIFTH EDITION WHERE THE VASD IS DETERMINED IN <br />R703.6.3 WATER -RESISTIVE BARRIES. <br />ACCORDANCE WITH SECTION R301.2.1.3 OR THE <br />WATER -RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN <br />RECOMMENDATIONS OF RAS 118,119 OR 120. <br />SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED SHEATHING, <br />REQUIRED UNDERLAYMENT PER F.B.C.R. - 5TH EDITION (2014) <br />SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH <br />R905.3.3 SHALL CONFORM WITH ASTM D 226, TYPE II; ASTM D 2626, <br />A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D <br />TYPE II; OR ASTM D 1970 OR ASTM D 6380, CLASS M MINERAL <br />PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY <br />SURFACED ROLL ROOFING AND SHALL BE INSTALLED IN <br />SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE <br />ACCORDANCE WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE <br />AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION R703.8) <br />AND CLAY ROOF TILE INSTALLATION MANUAL, FIFTH EDITION <br />INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS DIRECTED <br />WHERE THE VASD IS DETERMINED IN ACCORDANCE WITH <br />BETWEEN THE LAYERS. <br />SECTION R301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118,119 OR 120. <br />R312.2.1 Window sills. <br />In dwelling units, where the opening of an operable window is located more than 72 inches <br />(1829 mm) above the finished grade or surface below, the lowest part of the clear opening of <br />the window shall be a minimum of 24 inches (610 mm) above the finished floor of the room in <br />which the window is located. Operable sections of windows shall not permit openings that <br />allow passage of a 4 inch (102 mm) diameter sphere where such openings are located within <br />24 inches (610 mm) of the finished floor. <br />19'-4 7/8" <br />HEEL HGT. <br />18'-8 7/8" <br />BRG. HGT. <br />17'-10 3/4' <br />WDW. HGT. <br />1 U-8 3/4" <br />2nd FLR <br />\ 9'-4" <br />\ BRG. HGT. <br />s'-o° <br />PORCH BRG. HGT. <br />OPT. DECORATIVE <br />HANDRAIL <br />0'-0" <br />FIN. FLR. <br />DISCLAIMER <br />IT IS THE CONTRACTOR/SUB-CONTRACTORS RESPONSIBILITY TO REVIEW ALL <br />INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF <br />CONSTRUCTION. B&A DESIGN STUDIO, INC. & FLORIDA DESIGN SOLUTIONS INC. <br />IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR <br />CUSTOM CHANGES MISSED AND NOT REPORTED TO B&A DESIGN STUDIO, INC. & <br />FLORIDA DESIGN SOLUTIONS INC. PRIOR TO CONSTRUCTION. <br />NO EXCEPTIONS. <br />o E <br />It 0 <br />.F N QO N V <br />O <br />00 00 <br />• <br />_J <br />~ <br />O N <br />'O x CD <br />55 <br />i <br />F. ❑ � �-- OWN <br />gw�jX CD <br />iaLEM 7i <br />w3 y(d� � ��J <br />❑ U m f•*a oa �d Q <br />❑02in <br />UJZOF <br />U Z <br />El ib <br />OUwao z �ga <br />cc�--°oftr FESS8 <br />N oZg n Z°�71-1 <br />^i <br />`flll$i€It <br />�¢Cc, � Z >Mdrq <br />Ir <br />O r r -o ai I•s." Q <br />4t., o <br />UJ �Ow Uw <br />`� U ❑ <br />0T1 <br />U <br />F <br />N Y1IO�DN3SQ3'MMM <br />LL <br />W <br />J <br />0) <br />�LO <br />N � <br />N <br />Q W V <br />�- - � <br />O <br />Q o <br />Z ' <br />Z z O <br />W 0 <br />J 9 Q <br />m � <br />W <br />W <br />title: <br />ELEVATIONS <br />project no. <br />2017407 <br />checked: <br />AB/EC <br />drawn: <br />date: <br />07-06-17 <br />scale: <br />AS SHOWN <br />3A�l <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />