ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 — <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />Diaper to lights& oudets <br />Dipper to 20 amp ckh; <br />copper to WH <br />copper to Dryer <br />� AID <br />1 250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser DiagraM (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Mono)dde Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />tw_. P. <br />K�_G.F.I. <br />$3 <br />$R <br />#P.C. <br />FTVJ 2 <br />--=E--j <br />6� <br />09 <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />EYEBALL CENTER <br />ON WINDOW <br />BRKFST <br />GFI I <br />cl) <br />GFI <br />SWITCH FOR DISPOSAL <br />GFI <br />F -cI 11 <br />I Ak <br />U_ <br />ILL <br />c\l <br />E0 <br />01 P <br />GFI 9GFI <br />A <br />KIT <br />�F_ F 1] <br />A61 <br />— <br />— <br />IGFI <br />OPTIONAL LIGHTING <br />SCALE: Y4"=V-0" <br />P <br />PENDANT AS PER <br />UNDER COUNTER <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />1st FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />E <br />D <br />:r <br />D <br />_j <br />1� 0: <br />U Lu <br />L <br />U <br />> <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />0 19 <br />co <br />a <br />0 <br />to <br />C—f) <br />LU <br />0 LU <br />U-) <br />lk E <br />0 <br />2 co <br />.2 p <br />fn r- <br />0`11 <br />C) <br />LU <br />E <br />0) ce) <br />0) M <br />r_ M M <br />2:2 M <br />0 - C14 <br />.20 <br />U_ 00 <br />- 00 <br />0 42) <br />Qf <br />'00) <br />0 .2 i::- <br />05 as <br />< 0 <br />0:S <br />CL <br />(3) < 6 <br />A <br />8 D. <br />N-C-B D-C <br />Cc <br />to M <br />Ul) <br />co <br />C-, <br />60 <br />6 <br />Z LLI 00 Z <br />cj <br />ILL. ILL. <br />LL1 <br />LLJ Ljj <br />Ill. cl- <br /><> <br />LLI <br />Z 0 Jr-9 102 <br />0 !g <br />9;5 <br />Cf <br />Z s <br />Z <br />tr- <br />LL LU -0 1 <br />__j <br />LO IE <br />0 Ell <br />To the best ofthe Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and sea] is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seaL <br />C:) <br />C:) <br />Z <br />0 <br />1­4 C:) <br />U') i�o , <br />> J) ro — <br />p <br />Z <br />M Ln <br />< <br />6 <br />CU — in <br />L_ LL <br />Z <br />3- CL 00 <br />< <br />Z E <br />Z <br />Lu C:) <br />W <br />_j C:) <br />ko <br />0 <br />0� Z <br />LU LL <br />Z <br />LLJ z a, <br />ti � a <br />.;c <br />U Ln - �-j <br />P Z < 3 <br />OZ, OL <br />Z U Z <br />Z Z <br />LIJ Z <br />W <br />LL, <br />01% <br />0 Ln <br />U d <br />8 Ln 0 W 0 <br />= OR LU N <br />CD <br />F- a. 0 Z <br />LU Z <br />ce L4 <br />Ln <br />17114 <br />11711.4 <br />Ln <br />0 <br />LU <br />Ce <br />Z <br />W V) �.d <br />< Z 0 <br />LU 0 0 0 <br />0 <br />< <br />U W <br />r I.- Q! <br />0 Z <br />-0 <br />Z <br />0 <br />Z 5 um,: <br />U_ <br />Z <br />LU 00:)o <br />(D W Z 0 <br />< < U r- <br />ED <br />6 9 � - <br />> <br />< <br />0 2: <br />V) <br />r L) <br />W 0 ILL Z < <br />W <br />< 10 <br />rA <br />0 CyX LL Z <br />Z < <br />D <br />0 <br />C:) <br />.. �, Lu <br />< < 2: <br />c) <br />re) <br />Z <br />. . <br />.. Lu <br />LU <br />> <br />0 <br />Z <br />:5 <br />Z <br />U-1 <br />SCALE AS NOTED <br />PLOT DATE 12/7/2012 <br />TECH: ERAND <br />VERSION NO. <br />15m,25 <br />JOB NO: 16-6651 <br />SHEET NO. <br />5 <br />