6564 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6564 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:42:11 AM
Creation date
2/19/2025 12:57:57 PM
Metadata
Fields
Template:
Building Plans
Street #
6564
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18397
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />)pper to lights& outlets <br />)pper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />Alu <br />---------------------------- <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 --/ <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />------------------------------------------------ <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2"AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />FTT <br />DUPLEX OUTLET ABOVE COUNTER <br />K%.P. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />94 <br />FOUR-WAYSWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />#P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />14), <br />EXHAUST FAN/LIGHT COMBINATION <br />�Dj <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[�E <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />FTV1 <br />TELEVISION (OPTIONAL) <br />N 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /><1 \> <br />OPT. CEILING FAN <br />E;�) <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />— — — — — — — — — — — — — — — — — - <br />> <br />< <br />I/ V <br />MASTER <br />BEDROOM <br />L---------------------------------------------------------- j <br />2nd FLOOR ELECTRICAL <br />SCALE: Y4"=V-0" <br />0 LO <br />to <br />Lu <br />L/) 0 <br />Q) <br />C—f) <br />Lu <br />U <br />LLJ <br />0 <br />E <br />V) ry <br />=3 <br />0 <br />2 cn <br />Lf) <br />.2 CD <br />04 <br />C) <br />E <br />0 <br />Q M <br />0) ce) <br />a cc c', <br />C�a �0 M <br />'r N <br />0 00 <br />LL 00 <br />(D <br />U Iwo <br />15 - CO <br />o 5. i�� <br />U) CL 0 <br />< 0 <br />,, 0:S <br />,r CL <br />o) < 6 <br />A I <br />8 D. <br />1,C 11 D,C <br />*Y <br />F <br />LO <br />M <br />0-CN <br />U') <br />un, r-- <br />"' 0, cj <br />c� 6 C-4 <br />0 <br />6 6 <br />LU 00 Z <br />(:nl 0? 0C c�j <br />LL_ LL_ <br />14 4� C, 0. <br />LLI <> Ij Nr- <br />u- <br />ILL, LLJ <br />a- <br />0 <br />LLI U 'a ___5 <br />Z0 C 'a. co 5 <br />.00 (U -,t < <br />= <br />?:: <br />0 <br />(a 04 <br />rm, <br />Z <br />CD C14 LE- <br />JU Z <br />_j <br />0 C0 lt� <br />UD (5 a) <br />X Uj <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />C:) <br />Z <br />0 <br />0 <br />�-4 C:) <br />V) <br />4 p <br />4-J <br />V) <br />-2 <br />L_ <br />ON <br />Z <br />CL LE <br />� <br />31 (0,_j <br />0. 00 <br />< <br />Z E <br />Z <br />Uj C) F- <br />0 <br />OR Z <br />0 <br />Lu LL <br />LLJ Z ci� <br />LU co rE W <br />b VZ) <br />Z 0 <br />Z U 2: <br />Z UZ Z <br />Z <br />W, a,: U I <br />__l <br />CL U 0 un <br />C) = U 0 <br />0 Ce 0 <br />U 2 M 04 <br />C:) <br />0. 0 Z <br />LU Z <br />M <br />ce Lul <br />C:) <br />Ln <br />(1*4 <br />17�4 <br />Ln <br />LU o <br />LLI < <br />U) <br />Ce <br />Z U n <br />LU 0 0 0 0� <br />0 <br />< <br />u [0j-1 Zn E2 <br />fu <br />Z <br />Z CV2: 0 Z <br />LU 0 0 :D 0 <br />L_ <br />(3) <br />Z <br />LU <br />_j Z 0 <br />< U P <br />8 <br />RM90. <br />< <br />N c) <br />Uj 0 LL Z <br />0� uu Z 0 <br />n <br />CY >1 LL <br />En Z <br />0 Z <br />C:) <br />_j <br />D <br />a. LU <br />Q. <br />g <br />ci, <br />rr) <br />< <br />U_ <br />Z <br />. . Gi <br />Uj <br />> <br />0 <br />Z <br />:5 _j <br />Z <br />Lu <br />SCALE AS NOTED <br />PLOT DATE 12/7/2012 <br />TECH: EPAND <br />VERSION NO. <br />1525 <br />JOB NO: 16-6651 <br />SHEET NO. <br />6 <br />