My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6598 Bar S Bar Trl (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6598 Bar S Bar Trl (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:46:15 PM
Creation date
2/19/2025 1:00:14 PM
Metadata
Fields
Template:
Building Plans
Street #
6598
Location
Bar S Bar Trl
Contractor
Windward Building Group
Building Plans - Permit #
3364
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SYMBOLS LEGEND <br />LIGHTING (SEE LIGHTING FIXTURE SCHEDULE) <br />0 EVX MERGENCY ' IUAORESCENT STLIGHTING FIXTURE CONNECTED TO <br />4 LIGHT FIXTURE WALL MOUNTED. <br />0 LIGHTING FIXTURE - (NL) NIGHTLIGHT. <br />I-0 LIGHTING FIXTURE - WALL MOUNTED <br />WALL WASH / ACCENT FIXTURE - CEILING MOUNTED <br />®t EXIT SIGN - SINGLE FACE ARROW INDICATES DIRECTION - <br />CEILING MOUNTED <br />EMERGENCY LIGHT WITH INTEGRAL BATTERY PACK - <br />DUAL HEAD <br />SWITCHES <br />S SINGLE POLE SWITCH - TOGGLE TYPE. SEE ELECTRICAL <br />SPECIFICATIONS FOR MOUNTING HEIGHTS. <br />(3) 3 WAY <br />(4) 4 WAY <br />III DOUBLE POLE <br />P WITH PILOT LIGHT INDICATION <br />D DIMMER <br />K KEY <br />S M MOTOR RATED SWITCH - 1 POLE OR 2 POLE 30 AMP 250 VOLT WITH INTEGRAL <br />THERMAL OVERLOADS <br />SOS WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH. <br />OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. <br />DATAXOMM <br />TWH DATA/COMM OUTLET WITH FLUSH MOUNTED 4" SQUARE SINGLE GANG JUNCTION BOX. <br />PROVIDE BLANK STAINLESS STEEL COVER PLATE. EXTEND 1" CONCEALED CONDUIT TO <br />ABOVE ACCESSIBLE CEILING AND STUB -OUT WITH PLASTIC BUSHING. <br />® DATA/COMM OUTLET FLUSH MOUNTED IN FLOOR. <br />N❑ TELEVISION OUTLET. MOUNT 18 " ABOVE FINISHED FLOOR. <br />SERVICE AND DISTRIBUTION <br />i BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, <br />SURFACE MOUNTED, LION. <br />3M M FUSED DISCONNECT SWITCH.3-POLE, 30AMP ASTERISK <br />INDICATES TO FUSE ACCORDING TO MANUFACTURERS <br />RECOMMENDATIONS. NEMA 1 RATED INDOORS, NEMA 3R <br />RATED OUTDOORS. <br />3-R m, COMBINATION STARTER/DISCONNECT SWITCH 3-POLE, <br />30AMP, FUSED. NEMA SIZE 1 NEMA RATED NDOORS, <br />NEMA 3R RATED OUTDOORS. <br />mm UTILITY TRANSFORMER <br />I'TVSSI TRANSIENT VOLTAGE SURGE SUPPRESSOR. <br />SECURITY SYSTEM <br />® <br />CARD READER <br />(WP) WEATHERPROOF <br />® <br />CALL BOX <br />(WP) WEATHERPROOF <br />' <br />SECURITY SYSTEM CONTROL PANEL (SSCP) <br />POWER <br />(SEE ELECTRICAL SPECIFICATIONS FOR MOUNTING HEIGHTS.) <br />=0 <br />DUPLEX RECEPTACLE - SEE ELECTRICAL SPECIFICATIONS FOR MOUNTING <br />HEIGHTS. <br />(WP) WEATHERPROOF <br />(H) HORIZONTALLY MOUNTED <br />(G) CEILING MOUNTED <br />(TP) TAMPER PROOF <br />DOUBLE DUPLEX RECEPTACLE <br />=@ <br />"GFI- DUPLEX RECEPTACLE/GROUND FAULT INTERRUPTING <br />=@Wp <br />"GFI" DUPLEX RECEPTACLE/GROUND FAULT INTERRUPTING/WEATHERPROOF COVER <br />DUPLEX RECEPTACLE, COUNTER HEIGHT <br />DUPLEX RECEPTACLE - FLUSH MOUNTED IN FLOOR BOX. <br />® <br />DOUBLE DUPLEX RECEPTACLE MOUNTED TOGETHER IN A FLUSH MOUNTED FLOOR <br />BOX. <br />QF <br />JUNCTION BOX (SIZE AS REQUIRED PER N.E.C.). <br />(F) FAN RATED JUNCTION BOX. <br />OJ <br />WALL MOUNTED JUNCTION BOX (SIZE AS REQUIRED PER N.E.C.). <br />OEF <br />MOTOR <br />(EF) EXHAUST FAN <br />PC <br />PHOTO CELL <br />(� Wp <br />ELECTRICAL SERVICE SHUNT TRIP BREAK GLASS STATION <br />SQUARE "D" CLASS#900 1-K 15 W/ CLASS 9001-K25 STAINLESS STEEL COVER <br />PLATE. ENGRAVE "SERVICE DISCONNECT" MOUNT 7'-0" AFF./WEATHERPROOF HOUSING <br />® <br />GROUND BAR <br />BY OTHERS. FIRE DAMPER/SMOKE ALARM CONNECTION. <br />120e CEILING OR WALL MOUNTED 120 VOLT DUAL RATED RESIDENTIAL SELF <br />CM CONTAINED SMOKE AND CARBON MONOXIDE DETECTORS, DETECTOR WITH <br />BATTERY BACK UP. ALL UNITS SHALL BE TIED TOGETHER AND ALARM ALL <br />AT ONE TIME. MANUFACTURER: GENTEX #GN-503 SERIES. <br />CM = CARBON MONOXIDE DETECTOR <br />BY OTHERS. SMOKE AND CARBON MONOXIDE DETECTORS. <br />ABBREVIATIONS <br />A - <br />AMPERES <br />EMS - <br />ENERGY MANAGEMENT SYSTEM <br />KCMIL - <br />THOUSANDS OF CIRCULAR MILLS <br />A/C - <br />AIR CONDITIONING <br />EMT - <br />ELECTRICAL METALLIC TUBING <br />KVA - <br />KILOVOLT -AMPERES <br />AC - <br />ALTERNATING CURRENT <br />EF - <br />EXHAUST FAN <br />KW - <br />KILOWATT <br />AFF - <br />ABOVE FINISHED FLOOR <br />EWC - <br />ELECTRIC WATER COOLER <br />LED - <br />LIGHT EMITTING DIODE <br />AFG - <br />ABOVE FINISHED GRADE <br />EX - <br />EXISTING <br />LTG - <br />LIGHTING <br />AHU - <br />AIR HANDLING UNIT <br />FA - <br />FIRE ALARM <br />MCP - <br />MOTOR CIRCUIT PROTECTION <br />AWG - <br />AMERICAN WIRE GAUGE <br />FACP - <br />FIRE ALARM CONTROL PANEL <br />MCU - <br />MASTER CONTROL UNIT <br />C - <br />CONDUIT <br />FBC - <br />FLORIDA BUILDING CODE <br />N - <br />NEUTRAL <br />CH - <br />COUNTER HEIGHT <br />GFI - <br />GROUND FAULT INTERRUPTER <br />NA - <br />NOT APPLICABLE <br />CM - <br />CARBON MONOXIDE <br />GND - <br />GROUND <br />NEC - <br />NATIONAL ELECTRICAL CODE <br />CONC - <br />CONCRETE <br />GRC - <br />GALVANIZED RIGID CONDUIT <br />NEMA - <br />NATIONAL ELECTRICAL <br />MANUFACTURERS ASSOCIATION <br />COND - <br />CONDUIT <br />HVAC - <br />AND AIR <br />CONDm6NING NGTILATING <br />NFPA <br />NATIONAL FIRE PROTECTION <br />CU - <br />COPPER <br />ASSOCIATION <br />IWH - <br />INSTANTANEOUS WATER HEATER <br />_ <br />DISC - <br />DISCONNECT <br />NF <br />NON -FUSED <br />I.D. - <br />INTERIOR DESIGNER <br />ECB - <br />ENCLOSED CIRCUIT BREAKER <br />NIC - <br />NOT IN CONTRACT <br />I G - <br />ISOLATED GROUND <br />ELEC - <br />ELECTRICAL <br />NL - <br />NIGHT LIGHT <br />J - <br />JUNCTION <br />EM - <br />EMERGENCY <br />O.C. - <br />ON CENTER <br />KAIC - <br />(THOUSAND), AMPERE <br />INTERRUPTING CAPACITY <br />P - <br />POLE <br />PNL - <br />PANELBOARD <br />PVC - <br />POLYVINYL CHLORIDE <br />RGS - <br />RIGID GALVANIZED STEEL <br />RM - <br />ROOM <br />SPEC - <br />SPECIFICATION <br />SS - <br />STAINLESS STEEL <br />NSS - <br />TRANSIENT VOLTAGE <br />SURGE SUPPRESSION <br />TYP - <br />TYPICAL <br />UON - <br />UNLESS OTHERWISE NOTED <br />V - <br />VOLTS <br />W - <br />WIRE <br />WP - <br />WEATHERPROOF <br />GENERAL NOTE <br />THESE PLANS HAVE BEEN DESN•1�ED <br />N ACCORDANCE WITH THE 2017 <br />NATIONAL ELECTRICAL CODE <br />VOLTAGE DROP <br />THIS PROJECT IS IN COMPLIANCE <br />WITH 2O20 FBC-ENERGY <br />CONSERVATION C405.6.3 AND NEC <br />210.19 WITH REGARDS TO VOLTAGE <br />DROP (5%). <br />C1 <br />BARNES AND IVY: <br />#42E57 <br />FOYER PENDANT LIGHT <br />(4)30W <br />120V <br />CLUB HOUSE AREA <br />AS APPROVED BY OWNER <br />C2 <br />CIRCA LIGHTING: <br />TOWNER MINI PENDANT: #6141301-962 <br />SNACK AREA PENDANT LIGHT <br />35W <br />120V <br />CLUB HOUSE AREA <br />AS APPROVED BY OWNER <br />CH <br />PORTFOLIO: <br />#FD12-001 <br />EXTERIOR PENDANT LIGHT LIGHT <br />(3)60W <br />120V <br />CLUB HOUSE AREA <br />AS APPROVED BY OWNER <br />F ICOOPER LIGHTING <br />SSF-228T5-UNV-EBTI-U/WG <br />ENI ICOOPER LIGHTING <br />SURE-LITES APEL <br />EX ICOOPER LIGHTING <br />SURE-LITES APEX <br />W ICOOPER LIGHTING <br />XTOR5A-WT-LUMAR CROSSTOUR <br />FLUORESCENT STRIP (2)28W 120V <br />LED EMERGENCY LIGHT WITH INTEGRAL 90 1.6W 120V <br />MINUTE EMERGENCY BATTERY PACK LED <br />LED EXIT SIGN WITH INTEGRAL 90 MINUTE I 1.3W <br />EMERGENCY BATTERY PACK LED <br />W.P. WALL PACK - (5000K) <br />41W <br />LED <br />120V <br />120V <br />CLUB HOUSE AREA <br />CLUB HOUSE AREA <br />CLUB HOUSE AREA <br />EXTERIOR CLUBHOUSE <br />AS APPROVED BY OWNER <br />AS APPROVED BY OWNER <br />AS APPROVED BY OWNER <br />AS APPROVED BY OWNER <br />V <br />VALUE LIGHTING <br />AD452 <br />VANITY LIGHT <br />(3)60W <br />120V <br />CLUB HOUSE AREA <br />AS APPROVED BY OWNER <br />MINKAAIRE <br />NO <br />(Ft <br />F888-BNW <br />CEILING FAN <br />LIGHT <br />120V <br />CLUB HOUSE AREA <br />AS APPROVED BY OWNER <br />KIT <br />EC1F <br />MINKAAIRE <br />F888-BNW <br />SLIPSTREAM EXTERIOR FAN <br />NO <br />LIGHT <br />120V <br />CLUB HOUSE AREA <br />AS APPROVED BY OWNER <br />KIT <br />FL <br />ECOSENCE <br />F080-1S-HO-35-9-20-Z-F <br />EXTERIOR LED FLOOD LIGHT <br />41W <br />120V <br />CLUB HOUSE SITE <br />AS APPROVED BY OWNER <br />LED <br />PL D-SERIES SIZE 1 <br />DSX1 LED 40C 700 30 T3M-T5W <br />120-RPA <br />XX EMERGI-LITE <br />BZ-LUX-SD-FT <br />SITE LIGHTING <br />EXTERIOR EMERGENCY ONLY LIGHT <br />LED I 120V I CLUB HOUSE SITE I AS APPROVED BY OWNER <br />SHEET INFORMATION <br />[REVIEWED <br />TE: � 0 � 19 � 2(]2 <br />LED 120V CLUB HOUSE EXTERIOR AS APPROVED BY OWNER AWN BY: KR <br />OJECT N0: 20-6001 <br />BY: i MPlan Revisions Date: <br />06/04/2021 ISSUED FOR PERMIT <br />10/18/2021 OWNER REVISION <br />Sheet Name <br />ELECTRICAL <br />LEGEND, NOTES <br />CA# 26308 I21270.00 & <br />AlkI N G E N U I TY ABBREVIATIONS <br />ENGINEERS, INC. Sheet No. <br />14pp "PROACTIVE ENGINEERING SOLUTIONS" EO. 1 <br />4798 NEW BROAD ST. SUITE 300 1 ORLANDO, FLORIDA 1407.398.6007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.