My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6598 Bar S Bar Trl (3)
Zephyrhills
>
Building Department
>
Building Plans
>
6598 Bar S Bar Trl (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:56:01 PM
Creation date
2/19/2025 1:02:24 PM
Metadata
Fields
Template:
Building Plans
Street #
6598
Location
Bar S Bar Trl
Contractor
Windward Building Group
Building Plans - Permit #
3585
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I 1 I 1— u - 1 1 _ 1_ 1 1 ' 1 l_ II i 1 n 1 L L'll' 1 I I I I I J I I _ I I I I 1 I —. . - — L- - I I 1— I .--- <br />ELECTRICAL SYMBOLS LEGEND <br />LIGHTING (SEE LIGHTING FIXTURE SCHEDULE) <br />0 <br />RECESSED CAN DOWNLIGHT FIXTURE. <br />Fo <br />SURFACE MOUNT WALL SCONCE FIXTURE. <br />Q <br />RECESSED CAN DOWNLIGHT FIXTURE WITH INTEGRAL <br />EMERGENCY BATTERY BACKUP. <br />SURFACE MOUNT WALL SCONCE FIXTURE WITH INTEGRAL <br />EMERGENCY BATTERY BACKUP. <br />®} <br />EXIT SIGN - SINGLE FACE ARROW INDICATES DIRECTION - <br />CEILING MOUNTED <br />EMERGENCY LIGHT WITH INTEGRAL BATTERY PACK - <br />DUAL HEAD <br />CEILING FAN <br />LC LIGHTING CONTACTOR. <br />SWITCHES <br />S SINGLE POLE SWITCH - TOGGLE TYPE. SEE ELECTRICAL <br />SPECIFICATIONS FOR MOUNTING HEIGHTS. <br />(3) 3 WAY <br />4 4 WAY <br />III DOUBLE POLE <br />P WITH PILOT LIGHT INDICATION <br />D DIMMER <br />K KEY <br />S M MOTOR RATED SWITCH - 1 POLE OR 2 POLE 30 AMP 250 VOLT WITH INTEGRAL <br />THERMAL OVERLOADS <br />SOS WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH. <br />OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. <br />DS DAYLIGHT SENSOR. <br />DATA/COMM <br />'TWH DATA/COMM OUTLET WITH FLUSH MOUNTED 4" SQUARE SINGLE GANG JUNCTION BOX. <br />PROVIDE BLANK STAINLESS STEEL COVER PLATE. EXTEND 1" CONCEALED CONDUIT TO <br />ABOVE ACCESSIBLE CEILING AND STUB -OUT WITH PLASTIC BUSHING. <br />Mn <br />DATA/COMM <br />OUTLET <br />FLUSH MOUNTED IN FLOOR. <br />❑TV <br />TELEVISION <br />OUTLET. <br />MOUNT 18 " ABOVE FINISHED FLOOR. <br />SERVICE AND DISTRIBUTION <br />= BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, <br />SURFACE MOUNTED, LION. <br />34 M FUSED DISCONNECT SWITCH.3-POLE, 30AMP ASTERISK <br />INDICATES TO FUSE ACCORDING TO MANUFACTURERS <br />RECOMMENDATIONS. NEMA 1 RATED INDOORS, NEMA 3R <br />RATED OUTDOORS. <br />33D Mh COMBINATION STARTER/DISCONNECT SWITCH 3-POLE, <br />30AMP, FUSED. NEMA SIZE 1 NEMA RATED INDOORS, <br />NEMA 3R RATED OUTDOORS. <br />mm UTILITY TRANSFORMER <br />TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR. <br />NOTE: NOT ALL SYMBOLS SHOWN ARE USED IN THIS PROJECT. <br />POWER <br />(SEE ELECTRICAL SPECIFICATIONS FOR MOUNTING HEIGHTS.) <br />DUPLEX RECEPTACLE - SEE ELECTRICAL SPECIFICATIONS FOR MOUNTING <br />HEIGHTS. <br />(WP) WEATHERPROOF <br />(H) HORIZONTALLY MOUNTED <br />(G) CEILING MOUNTED <br />(TP) TAMPER PROOF <br />DOUBLE DUPLEX RECEPTACLE <br />"GFI" DUPLEX RECEPTACLE/GROUND FAULT INTERRUPTING <br />.OWP <br />"GFI" DUPLEX RECEPTACLE/GROUND FAULT INTERRUPTING/WEATHERPROOF COVER <br />=@ <br />DUPLEX RECEPTACLE, COUNTER HEIGHT <br />❑� <br />DUPLEX RECEPTACLE - FLUSH MOUNTED IN FLOOR BOX. <br />® <br />DOUBLE DUPLEX RECEPTACLE MOUNTED TOGETHER IN A FLUSH MOUNTED FLOOR <br />BOX. <br />QF <br />JUNCTION BOX (SIZE AS REQUIRED PER N.E.C.). <br />(F) FAN RATED JUNCTION BOX. <br />QJ <br />WALL MOUNTED JUNCTION BOX (SIZE AS REQUIRED PER N.E.C.). <br />MOTOR <br />OEF <br />(EF) EXHAUST FAN <br />PC <br />PHOTO CELL <br />(-Q Wp <br />ELECTRICAL SERVICE SHUNT TRIP BREAK GLASS STATION <br />SQUARE "D" CLASS#900 1-K15 W/ CLASS 9001-K25 STAINLESS STEEL COVER <br />PLATE. ENGRAVE "SERVICE DISCONNECT" MOUNT 7'-0" AFF./WEATHERPROOF HOUSING <br />GROUND BAR <br />1208 <br />CEILING OR WALL MOUNTED 120 VOLT DUAL RATED RESIDENTIAL SELF <br />CM <br />CONTAINED SMOKE AND CARBON MONOXIDE DETECTORS, DETECTOR WITH <br />BATTERY BACK UP. ALL UNITS SHALL BE TIED TOGETHER AND ALARM ALL <br />AT ONE TIME. MANUFACTURER: GENTEX #GN-503 SERIES. <br />CM = CARBON MONOXIDE DETECTOR <br />BY OTHERS. SMOKE AND CARBON MONOXIDE DETECTORS. <br />FIRE ALARM <br />FD MANUAL PULL STATION WP=WEATHERPROOF <br />I� COMBINATION AUDIBLE AUDIO/VISUAL SIGNALING UNIT- HORN/FLASHING "FIRE" LIGHT <br />WALL MOUNTED 48" AFF UNLESS OTHERWISE NOTED. WP=WEATHER PROOF. 110 <br />CANDELA UNLESS NOTED OTHERWISE. LOW FREQUENCY SOUNDER (520 HZ.) <br />FABCP FIRE ALARM CONTROL PANEL. <br />Fo REMOTE FIRE ALARM ANNUNCIATOR PANEL (FLUSHED MOUNTED). <br />J <br />A - <br />AMPERES <br />EMS - <br />ENERGY MANAGEMENT SYSTEM <br />A/C - <br />AIR CONDITIONING <br />EMT - <br />ELECTRICAL METALLIC TUBING <br />AC - <br />ALTERNATING CURRENT <br />EF - <br />EXHAUST FAN <br />AFF - <br />ABOVE FINISHED FLOOR <br />EWC - <br />ELECTRIC WATER COOLER <br />AFG - <br />ABOVE FINISHED GRADE <br />EX - <br />EXISTING <br />AHU - <br />AIR HANDLING UNIT <br />FA - <br />FIRE ALARM <br />AWG - <br />AMERICAN WIRE GAUGE <br />FACP - <br />FIRE ALARM CONTROL PANEL <br />C - <br />CONDUIT <br />FBC - <br />FLORIDA BUILDING CODE <br />CH - <br />COUNTER HEIGHT <br />GFI - <br />GROUND FAULT INTERRUPTER <br />CM - <br />CARBON MONOXIDE <br />GND - <br />GROUND <br />CONIC - <br />CONCRETE <br />GRC - <br />GALVANIZED RIGID CONDUIT <br />COND - <br />CONDUIT <br />HVAC - <br />HEATING VENTILATING AND AIR <br />CONDITIONING <br />CU - <br />COPPER <br />IWH - <br />INSTANTANEOUS WATER HEATER <br />DISC - <br />DISCONNECT <br />I.D. - <br />INTERIOR DESIGNER <br />ECB - <br />ENCLOSED CIRCUIT BREAKER <br />I G - <br />ISOLATED GROUND <br />ELEC - <br />ELECTRICAL <br />J - <br />JUNCTION <br />EM - <br />EMERGENCY <br />KAIC - <br />(THOUSAND) AMPERE <br />INTERRUPTING CAPACITY <br />KCMIL - THOUSANDS OF CIRCULAR MILLS <br />KVA - <br />KILOVOLT -AMPERES <br />KW - <br />KILOWATT <br />LED - <br />LIGHT EMITTING DIODE <br />LTG - <br />LIGHTING <br />MCP - <br />MOTOR CIRCUIT PROTECTION <br />MCU - <br />MASTER CONTROL UNIT <br />N - <br />NEUTRAL <br />NA - <br />NOT APPLICABLE <br />NEC - <br />NATIONAL ELECTRICAL CODE <br />NEMA - <br />NATIONAL ELECTRICAL <br />MANUFACTURERS ASSOCIATION <br />NFPA <br />NATIONAL FIRE PROTECTION <br />ASSOCIATION <br />- <br />NF <br />NON -FUSED <br />NIC - <br />NOT IN CONTRACT <br />NL - <br />NIGHT LIGHT <br />O.C. - <br />ON CENTER <br />Z M <br />r psi O <br />WWI <br />A,Z N <br />64 <br />Z <br />i <br />Q:__ <br />� J <br />i <br />GENERAL NOTES <br />THESE PLANS HAVE BEEN <br />P - <br />POLE <br />DESIGNED <br />IN ACCORDANCE WITH THE 2017 <br />k, <br />PNL - <br />PANELBOARD <br />NATIONAL ELECTRICAL CODE. <br />° o <br />PVC - <br />POLYVINYL CHLORIDE <br />s"' 4_ ..... — <br />RGS - <br />RIGID GALVANIZED STEEL <br />w <br />RM - <br />ROOM <br />o <br />SPEC - <br />SPECIFICATION <br />SS - <br />STAINLESS STEEL <br />VOLTAGE DROP <br />w <br />~ <br />�U-) <br />TVSS - <br />TRANSIENT VOLTAGE <br />, e U <br />J " Co <br />SURGE SUPPRESSION <br />THIS PROJECT IS IN COMPLIANCE <br />I � r, <br />'s <br />�� t ,1, ti^ N <br />L U <br />IL � <br />TYP - <br />TYPICAL <br />WITH 2O20 FBC-ENERGY <br />Y <br />a Co <br />UON - <br />UNLESS OTHERWISE NOTED <br />CONSERVATION C405.5.3 AND NEC <br />°' <br />N <br />V — <br />VOLTS <br />210.19 WITH REGARDS TO VOLTAGE <br />DROP (596). <br />e <br />W - <br />WIRE <br />WP - <br />WEATHERPROOF <br />THIS DOCUMENT AND/OR THE DESIGN CONCEPTS <br />EXPRESSED HEREIN ARE THE PROPERTY OF <br />KLLSEE ASSOCIA I"ES AND ALL RIGHTS 01 <br />OWNERSHIP, INCLUDING COPYRIGHT OF <br />INTELLECTUAL PROPERTY, ARE RESERVED. THE <br />RLPRODUCTIONS, COPYING, OR USE OF THIS <br />DOCUMENT AND/OR THE DESIGN CONCEPT <br />WITHOUT THE WRITTEN CONSENT OF KEESEE <br />ASSOCIATES IS STRICTLY PROHIBH ED AND <br />PROTECTED BY UNITED STATES AND <br />INTERNATIONAL LAW. <br />LIGHTING FIXTURE SCHEDULE <br />GAME PAVILION FIXTURES <br />TYPE <br />MANUFACTURER & CATALOG NO. <br />DESCRIPTION <br />WATTS <br />VOLTAGE <br />REMARKS <br />OR APPROVED EQUALS BY <br />A <br />COOPER LIGHTING <br />6" RECESSED DOWNLIGHT, <br />21W <br />LED <br />120V <br />GAME PAVILLION <br />APPROVED BY OWNER <br />PD6-20-ED010-PDM6A-835-64VC <br />LED <br />B <br />COOPER LIGHTING <br />6" RECESSED DOWNLIGHT, <br />21 W <br />PD6-20-ED010-REM-PDM6A-835-64VC <br />LED, WITH INTEGRAL 90 MINUTE <br />LED <br />120V <br />GAME PAVILLION <br />AS APPROVED BY OWNER <br />EMERGENCY BATTERY PACK. WET LOCATION <br />CiF1 <br />F888-IRE <br />888-BNW <br />CEILING FAN <br />NO <br />LIGHT <br />120V <br />GAME PAVILLION <br />AS APPROVED BY OWNER <br />KIT <br />EM <br />COOPER LIGHTING <br />LED EMERGENCY LIGHT WITH INTEGRAL 90 <br />1.6W <br />120V <br />GAME PAVILLION <br />AS APPROVED BY OWNER <br />SURE-LITES APEL <br />MINUTE EMERGENCY BATTERY PACK <br />LED <br />EX <br />COOPER LIGHTING <br />SURE-LITES APEX <br />LED EXIT SIGN WITH INTEGRAL 90 MINUTE <br />1.3W <br />LED <br />120V <br />GAME PAVILLION <br />AS APPROVED BY OWNER <br />EMERGENCY BATTERY PACK <br />W <br />COOPER LIGHTING <br />XTOR5A-WT-LUMAR CROSSTOUR <br />W.P. WALL PACK - (5000K) <br />41W <br />LED <br />120V <br />GAME PAVILION EXTERIOR <br />AS APPROVED BY OWNER <br />L0 <br />N <br />a <br />w <br />U) <br />� a <br />,� <br />Un <br />a <br />Z <br />� � <br />N <br />C <br />C) a� <br />U <br />PERMIT 01/26/2022 <br />REV. REV. REV. <br />NO. DESC. DATE <br />REVISIONS <br />Project Number: 21-7431 <br />Date: 01 /26/2022 1,30:00 PM <br />Issue Date: 01/26/2 <br />Reviewed By: KR <br />Drawn By: JM <br />Scale: As indicated <br />Sheet Name: <br />ELECTRICAL LEGEND, <br />NOTES & ABBREVIATIONS <br />CA# 26308 <br />I21570.00 <br />idlk <br />I N G E N U I T Y <br />Sheet No. <br />RIF <br />ENGINEERS, INC. <br />"PROACTIVE ENGINEERING SOLUTIONS" <br />4798 NEW BROAD ST. SUITE 300 1 ORLANDO, FLORIDA 1407.398.6007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.