My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6607 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6607 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:52:31 PM
Creation date
2/19/2025 1:04:02 PM
Metadata
Fields
Template:
Building Plans
Street #
6607
Location
Gall Blvd
Contractor
SL2 Consulting LLC
Building Plans - Permit #
3138
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECURITY SYSTEM LEGEND: -1 <br />SP SPEAKER <br />MD MOTION DETECTOR <br />ES ELECTRIC STRIKE - 12VOLTS ADAMSRITE ELECTRIC STRIKE OR EQUAL <br />CR CARD READER - CORTEX COR - ACC890 OR EQUAL <br />LR LOCK RELEASE <br />I <br />CB CRASH BAR WITH SURFACE STRIKE <br />M! MAG LOCK - SDC 350 NARROW LINE SINGLE EMLOCK (1200 LBS, 12V OR EQUAL) <br />DUPLEX OUTLET (GROUNDING) <br />DATA JACK - LEVITON ATLAS XICAT 6A OUICKPORT CONNECTOR <br />W/41080-IWP WALLPLATE <br />(2) CAT5 DROPS PER MARK. TONED, TESTED, LABELED <br />VA UNDER CABINETS - DUPLEX OUTLET & CAT 6 DATA OUTLET <br />19AI UNDER CABINETS - QUAD OUTLET & CAT 6 DATA OUTLET <br />6GFI GROUND FAULT INTERRUPTER <br />Ir HDMI TERMINATION BOX WITH DUPLEX RECEPTACLE - DATACOMM <br />45-0051-WH OR EQUAL <br />0 SECURITY CAMERAS <br />360 DEG SECURITY CAMERA <br />® 180 DEG SECURITY CAMERA <br />0 ALARM KEY PAD <br />® ALARM SENSOR <br />HANDICAP AUTOMATIC PUSH BUTTON <br />®ALARM/DATAANTERNET <br />HDMI/NETWORK CLOSET <br />AC/SPKR/RCVR <br />1� <br />=AP/WIFI - (1) CAT5 DROP PER MARK, SHOULD <br />LEAVE SERVICE LOOP IN CEILING ABOVE MARK <br />NOTES: <br />I. REAR DOORS MUST HAVE BREAKER BAR FOR EGRESS. <br />2. ALL POS AND ATM CAT5 DROPS ARE SINGLE, TERMINATED IN A BOX WITH KEYSTONES. <br />3. MULTI CAM LENSES ARE (1) 2.8MM AND (2) 4MM AND (1) 6 OR 8MM. <br />ELECTROMAGNETICALLY LOCKED EGRESS DOORS. <br />ELECTROMAGNETICALLY LOCKED DOORS SHALL BE EQUIPPED WITH LISTED HARDWARE THAT <br />INCORPORATES A BUILT-IN SWITCH AND MEET THE REQUIREMENTS BELOW: <br />1. THE LISTED HARDWARE THAT IS AFFIXED TO THE DOOR LEAF HAS AN OBVIOUS METHOD OF <br />OPERATION THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS. <br />2. THE LISTED HARDWARE IS CAPABLE OF BEING OPERATED WITH ONE HAND. <br />3. OPERATION OF THE LISTED HARDWARE DIRECTLY INTERRUPTS THE POWER TO THE <br />ELECTROMAGNETIC LOCK AND UNLOCKS THE DOOR IMMEDIATELY. <br />4. LOSS OF POWER TO THE LISTED HARDWARE AUTOMATICALLY UNLOCKS THE DOOR, <br />5. WHERE PANIC OR FIRE EXIT HARDWARE IS INSTALLED, OPERATION OF THE LISTED PANIC OR <br />FIRE EXIT HARDWARE ALSO RELEASES THE ELECTROMAGNETIC LOCK. <br />ACCESS -CONTROLLED EGRESS DOORS. <br />THE ENTRANCE DOORS ARE TO BE EQUIPPED WITH AN APPROVED ENTRANCE AND EGRESS <br />ACCESS CONTROL SYSTEM, LISTED IN ACCORDANCE WITH UL 294, WHICH SHALL BE INSTALLED IN <br />ACCORDANCE WITH NFPA 7.2.1.6.2 " ACCESS -CONTROLLED EGRESS DOORS" AND ALL OF THE <br />FOLLOWING CRITERIA: <br />1. A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE ARRANGED TO DETECT AN OCCUPANT <br />APPROACHING THE DOORS. THE DOORS SHALL BE ARRANGED TO UNLOCK BY A SIGNAL FROM <br />OR LOSS OF POWER TO THE SENSOR. <br />2. LOSS OF POWER TO THAT PART OF THE ACCESS CONTROL SYSTEM WHICH LOCKS THE DOORS <br />SHALL AUTOMATICALLY UNLOCK THE DOORS. <br />3. THE DOORS SHALL BE ARRANGED TO UNLOCK FROM A MANUAL UNLOCKING DEVICE LOCATED <br />40 INCHES TO 48 INCHES (1016 MM TO 1219 MM) VERTICALLY ABOVE THE FLOOR AND WITHIN 5 <br />FEET (1524 MM) OF THE SECURED DOORS. READY ACCESS SHALL BE PROVIDED TO THE MANUAL <br />UNLOCKING DEVICE AND THE DEVICE SHALL BE CLEARLY IDENTIFIED BY A SIGN THAT READS <br />"PUSH TO EXIT." WHEN OPERATED, THE MANUAL UNLOCKING DEVICE SHALL RESULT IN DIRECT <br />INTERRUPTION OF POWER TO THE LOCKINDEPENDENT OF THE ACCESS CONTROL SYSTEM <br />ELECTRONICSAND THE DOORS SHALL REMAIN UNLOCKED FOR A MINIMUM OF 30 SECONDS. <br />4. ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY <br />UNLOCK THE DOORS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM <br />SYSTEM HAS BEEN RESET. <br />5. ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER OR FIRE DETECTION SYSTEM, IF <br />PROVIDED, SHALL AUTOMATICALLY UNLOCK THE DOORS. THE DOORS SHALL REMAIN UNLOCKED <br />UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET. <br />6. ENTRANCE DOORS SHALL NOT BE SECURED FROM THE EGRESS SIDE DURING PERIODS THAT <br />THE BUILDING IS OPEN TO THE GENERAL PUBLIC. <br />7. ALL ACCESS CONTROLLED EGRESS DOOR WORK IS UNDER THIS PERMIT <br />IF JUNCTION BOX <br />CEILING <br />48' <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />L <br />KEYNOTES <br />LJ O48- X 72" X FINISH GRADE <br />PLYWOOD MOUN4TED TO WALL <br />OPAINT WHITE WITH FIRE RETARDANT <br />PAINT <br />LIMITED ENERGY CONDUIT AS NECESSARY TO ROUTE <br />MSYSTEMOUNTING O CABLING FROM CEILING TO BOARD <br />BOARD O #6 AWG SOLID COPPER GROUND <br />TO oBUILDINGyy GROUNDING SYSTEM <br />O O O INTERNETTSERVICE UCASWE E FOR <br />4 <br />v (2) QUAD RECEPTACLES <br />FLOOR WE —(SEE POWER PLAN) <br />LIMITED ENERGY SYSTEM <br />1 MOUNTING BOARD <br />71) 11 NOT TO SCALE <br />MOTION MD - <br />DETECTOR _--------------------------------- T _ <br />' I _-----_--_-- I DOOR & <br />�1 S,IREN WINDOW <br />SENSORS <br />SECURITY <br />CAMERA 6 II 6 T <br />LIMITED ENERGY SYSTEM I � � : — — -- <br />BOARD IN SAFE ROOM j I I i �•--------•-----•—•------------•—••--- I <br />SEE DETAIL 2/EI.2 ! I I 1 1 I 1 <br />, <br />VIDEC <br />I j�I <br />AND <br />DATA <br />TV � <br />BOAR <br />OR � <br />TV <br />' VD <br />JACK DATA <br />JACK <br />INTERNET SERVICE "*— <br />BY SERVICE PROVIDER <br />OVERHEAD OR UNDERGROUND <br />—.......................... <br />L <br />SECURITY SECURITY ACCESS ........... "—' "1 <br />CAMERA SYSTEM SYSTEM ALARM ; I MOCK <br />DVR AND PANEL PANEL & KEYPAD I U 5 j <br />D POWER POWER ; I <br />SUPPLY SUPPLY j <br />I <br />SC 'ss 'ss 'K i LR ES <br />3 I <br />B M ELEC. <br />CR O STRIKE <br />(...._ ._.._.._.._.._..� .._ 8 A CARD <br />5 READER <br />LEGEND <br />......... LIMITED ENERGY CABLING <br />LIMITED ENERGY <br />.RISER DIAGRAM <br />NOT TO SCALE <br />EXTERIOR AND INTERIOR <br />STOREFRONT DOORS <br />KEYNOTES: <br />O CAT 5 CABLE <br />O CAT 5E CABLE <br />O 22-4 CABLE <br />O 18-2 CABLE <br />INTERIOR DOORS <br />O 18-4 STRANDED CABLE <br />(� 18-2 STRANDED CABLE <br />O HDMI CABLE <br />OFAIL-SAFE "REQUEST TO EXIT" <br />B BUTTON AND MOTION DETECTOR <br />® 22-8 SHIELDED CABLE <br />0 <br />x <br />LOW VOLTAGE <br />iyirnc�e�w� <br />SCALE 1 /4" = 1'-0" <br />ELECTRICAL SECURITY SYSTEM NOTES: <br />I. ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, NATIONAL <br />ELECTRIC CODE AND ALL OTHER APPLICABLE CODES AND ORDINANCES. <br />2. GENERAL CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED FOR A COMPLETE INSTALLATION <br />AND FOR PROPER OPERATION OF ELECTRICAL LIMITED ENERGY SYSTEMS, INCLUDING ALL WORK <br />REQUIRED BY CODE OR REGULATORY AGENCIES. <br />3. LIMITED ENERGY CABLING INCLUDES THERMOSTAT WIRING, SECURITY CABLING, NETWORK CABLING, <br />VIDEO CABLING AND DOOR BUZZER WIRE. LIMITED ENERGY SYSTEM CABLING (LOW VOLTAGE) <br />SHALL BE CMR TYPICAL. IF WIRE IS RUN THRU HVAC PLENUMS THEN USE CLASS 2 (CMP <br />PLENUM RATED) CABLING. <br />4. LIMITED ENERGY SYSTEM CABLING (LOW VOLTAGE) SHALL BE CMR TYPICAL. IF WIRE IS RUN <br />THRU HVAC PLENUMS THEN USE CLASS 2 (CMP PLENUM RATED) CABLING. CONTRACTOR SHALL <br />INSTALL TERMINATION JACKS ON BOTH ENDS OF ALL NETWORK CABLES. <br />5. OWNER TO PROVIDE AND INSTALL THE FOLLOWING SECURITY SYSTEM ELEMENTS: <br />A. VIDEO AND DATA EQUIPMENT AND TELEVISIONS. <br />B. SECURITY CAMERA DVR SYSTEM, POWER SUPPLY AND CAMERAS. <br />C. SECURITY SYSTEM PANEL (GE CONCORD), KEY PAD, MOTION DETECTORS, DOOR/WINDOW <br />SENSORS AND SIRENS. <br />D. ACCESS SYSTEM PANEL, CARD READERS, POWER SUPPLY, DOOR BUZZ BUTTON, FAIL-SAFE <br />BUTTON AND MOTION DETECTOR BUTTON. <br />S. GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL THE FOLLOWING: <br />A. 12 V ELECTRIC DOOR STRIKES. <br />B. 12 V MAGNETIC LOCKS. <br />C. CARD READERS. <br />D. COORDINATION OF ALL DOORS, DOOR JAMBS AND HARDWARE TO ACCEPT ELECTRIC LOCKS <br />AND CARD READERS. <br />E. ALL LIMITED ENERGY WIRING/CABLING. <br />F. STANDARD MALE HDMI CONNECTORS SHALL BE INCLUDED ON EACH END OF HDMI CABLES. <br />G. STANDARD RJ-45 MODULAR PLUGS SHALL BE INCLUDED ON EACH END OF NETWORK <br />CABLES. <br />7. GENERAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF OWNER -SUPPLIED ITEMS WITH <br />THE OWNER'S SYSTEM INSTALLERS: <br />A. COORDINATE THE EXACT LOCATION OF OWNER -SUPPLIED ELEMENTS PRIOR TO INSTALLING <br />CABLE AND WIRE. <br />B. COIL AND TWIST TIE WIRE ENDS LEAVING A MINIMUM OF 24" OF CABLE LOOPED AT <br />TERMINATION POINTS. <br />C. CONTACT OWNER'S SECURITY COMPANY, MASADA SECURITY OF FLORIDA INC. (727) <br />579-3836 TO COORDINATE WORK ON THIS PROJECT. <br />8. AS AN OPTION, EXISTING DOORS SHOWN TO RECIEVE ELECTRIC DOOR STRIKES CAN BE FITTED <br />WITH MAGNETIC LOCKS IF EXISTING CONDITIONS ARE NOT EASILY MODIFIED TO ACCEPT STRIKES. <br />Revisions Date By <br />Mark A. jonnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway 19 N <br />Clearwater, Florida 33765 <br />(727) 725-ARCH <br />(727) 725-2603 fx <br />www.jarch.com <br />info@jarch.com <br />C jonnatti Architecture <br />Incorporated 2021 <br />06 <br />Truti..VIC <br />INTERIOR <br />REMODEL <br />US HWY 301 <br />GALL BL VD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />LOW VOLTAGE <br />SECURITY PLAN <br />(Drawn <br />I MAJ <br />Check <br />MAJ <br />Date <br />AUG 31, 2021 <br />Scale <br />AS NOTED <br />Job No <br />TRULIEVE-ZH <br />Sheet: <br />
The URL can be used to link to this page
Your browser does not support the video tag.