My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6607 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6607 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:52:31 PM
Creation date
2/19/2025 1:04:02 PM
Metadata
Fields
Template:
Building Plans
Street #
6607
Location
Gall Blvd
Contractor
SL2 Consulting LLC
Building Plans - Permit #
3138
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING RTU SCHEDULE <br />EQUIPMENT DESIGNATION <br />- <br />RTU-1 <br />RTU-2 <br />NOMINAL TONNAGE <br />TONS <br />5.0 <br />7.5 <br />SUPPLY AIR <br />CFM <br />2,000 <br />3,000 <br />OUTSIDE AIR <br />CFM <br />174 <br />429 <br />EXT. STATIC PRESSURE <br />IN. H2O <br />0.60 <br />0.60 <br />FAN SPEED <br />RPM <br />- <br />- <br />INDOOR FAN MOTOR <br />H.P. <br />1.0 <br />1.5 <br />FILTER TYPE <br />- <br />2"-307. <br />2"-30% <br />POWER <br />VOLTS/PH. <br />208/3 <br />208/3 <br />ELECTRICAL <br />MCA/MOCP <br />56.0/60.0 <br />51.0/60.0 <br />TOTAL COOLING CAPACITY <br />BTUH <br />59,500 <br />88,000 <br />SENSIBLE COOLING CAPACITY <br />BTUH <br />42,800 <br />65,100 <br />ENT, AIR TEMP. (DB/WB) <br />'F/'F <br />80/67 <br />80/67 <br />LVG. AIR TEMP. (DB/WB) <br />'F/'F <br />58/56 <br />58/56 <br />SEER/EER ® ARI CONDITIONS <br />- <br />13.0/ <br />-/11.2 <br />AMBIENT TEMPERATURE <br />'F <br />95 <br />95 <br />APPROX. UNIT WEIGHT W/CURB <br />LBS. <br />830 <br />1,260 <br />MANUFACTURER <br />- <br />DAIKIN <br />DAIKIN <br />MODEL NO. <br />- <br />DCC060 <br />DCCO90 <br />ELECTRIC HEAT ® 208 VOLT <br />KW <br />15.2 <br />12.16 <br />NOTES <br />® 11 <br />1 2 3 <br />COT <br />lO PROVIDE / INSTALL WITH FACTORY PROGRAMMABLE THERMOSTAT <br />(2 STAGE ASAF REQUIRED) <br />O SUBSTITUTE EQUIPMENT MANUFACTURERS SHALL BE PERMITTED <br />UPON APPROVAL OF ARCHITECT. EQUIPMENT SHALL HAVE <br />EQUIVALENT PERFORMANCE <br />3O PROVIDE OUTSIDE AIR CFMS AS SHOWN ON OUTSIDE AIR <br />CALCULATIONS FOR EACH UNIT <br />MINISPLIT SCHEDULE <br />AIR HANDLER MARK: <br />AHU 3 <br />UNIT MODEL NUMBER: <br />YORK DCP09NWBIIS <br />OR APPROVED EQUAL <br />CABINET INSULATION: <br />MINI SPLIT <br />UNIT VOLTAGE: <br />115/1/60 <br />REFRIGERANT TYPE: <br />A410A <br />HEATSTRIP KW: <br />NONE <br />MCA / MOCP: <br />20 AMPS (MOCP) <br />UNIT DIMEN LWH: <br />33" X II" X 8" <br />CONDENSER MARK <br />CU-3 <br />UNIT MODEL NUMBER: <br />YORK DCP09CSBIIS <br />OR APPROVED EQUAL <br />UNIT VOLTAGE: <br />0.75 TONS <br />UNIT MCA / BREAKER: <br />- <br />RL AMPS - LR AMPS: <br />- <br />UNIT DIMEN LWH: <br />31' x 21" x 12.5' <br />PERFORMANCE DATA: <br />TOTAL COOLING BTUH: <br />9,000 BTUH <br />SENS. COOLING BTUH: <br />6,600 BTUH <br />TOTAL HEATING BTUH: <br />0 BTUH <br />ACTUAL AIRFLOW CFM: <br />300 CFM <br />OUTDOOR AIR CFM: <br />0 CFM <br />SEER: <br />23.0 <br />THERMOSTAT MODEL: <br />INCLUDED WITH UNIT <br />OUTSIDE AIR CALCULATIONS <br />PER FLORIDA MECHANICAL CODE 2020 SEC 403.3.1.1 AND ASHRAE 62.1 <br />VbZ Rp*PZ + R,#AZ = CFM REQUIRED <br />= VbZ <br />Vaz EZ <br />ZONE <br />SPACE <br />OCC <br />DENSITY <br />/1000 <br />SO FT <br />PEOPLE <br />OUTDOOR <br />AIR RATE <br />(Rp) <br />ZONE <br />POPULAT <br />(PZ) <br />OUTDOOR <br />AIR RATE <br />(R,) <br />ZONE <br />FLOOR <br />AREA <br />(AZ) <br />EXHAUST <br />(Ea) <br />BREATHING <br />ZONE <br />(VbZ) <br />ZONE <br />OUTDOOR <br />AIRFLOW <br />(V,Z) <br />RTUI <br />DISPENSARY <br />15 <br />IO <br />13.5 <br />0.12 <br />904 <br />N/A <br />243.4 <br />320.4 <br />BREAK AREA <br />25 <br />5 <br />8.1 <br />0.06 <br />327 <br />N/A <br />60.1 <br />MANAGER OFFICE <br />5 <br />5 <br />.4 <br />0.06 <br />80 <br />N/A <br />9.6 <br />TOILET ROOM 2 <br />0 <br />0 <br />0 <br />0 <br />53 <br />160 <br />0 <br />SMALL INVENTORY <br />0 <br />5 <br />0 <br />0.06 <br />123 <br />N/A <br />7.3 <br />RTU2 <br />LOBBY/RECPT <br />30 <br />5 <br />27 <br />0.06 <br />903 <br />N/A <br />189.1 <br />484.9 <br />MAIN INVENTORY <br />0 <br />5 <br />0 <br />0.06 <br />979 <br />N/A <br />58.7 <br />VESTIBULE 1 <br />30 <br />5 <br />1.3 <br />0.06 <br />45 <br />N/A <br />9.2 <br />VESTIBULE 2 <br />30 <br />5 <br />1.1 <br />0.06 <br />38 <br />N/A <br />7.8 <br />CONSULT ROOM <br />50 <br />5 <br />2.9 <br />0.06 <br />59 <br />N/A <br />18.0 <br />EXPRS CHECK -IN <br />15 <br />5 <br />.7 <br />0.06 <br />45 <br />N/A <br />6.2 <br />MANTRAP <br />0 <br />5 <br />0 <br />0.06 <br />64 <br />N/A <br />3.8 <br />TOILET ROOM I <br />0 <br />0 <br />0 <br />0 <br />53 <br />160 <br />0 <br />AHU3 <br />IT CLOSET <br />0 <br />5 <br />0 <br />0.06 <br />1 50 <br />1 N/A <br />3.0 <br />3.0 <br />TOTAL O/A REQUIRED = 808.3 CFM TOTALS 320 808.3 <br />C/A PROVIDED THROUGH UNITS <br />RTU-1 = 320.4 CFM <br />RTU-2 = 484.9 CFM <br />AHU-3 = 0 CFM <br />HVAC LEGEND <br />RECTANGULAR DUCTWORK <br />T <br />O <br />7-DAY PROGRAMMABLE THERMOSTAT <br />MOUNTED AT 60 A.F.F. <br />/VVVVV <br />ROUND FLEXIBLE DUCTWORK <br />OH <br />HUMIDSTAT MTD AT 60"A.F.F. <br />FLEX. DUCT MIXING BOXES <br />SD <br />DUCT MTD SMOKE DETECTOR <br />ROUND METAL DUCTWORK <br />DUCT MOUNTED FIRESTAT <br />VOLUME CONTROL DAMPER <br />F�,& IN WALL FIRE DAMPER <br />DUCT ELBOW -TURNING VANES <br />FD <br />1 <br />DUCT MTD FIRE SMOKE DAMPER <br />RETURN DUCT SECTION <br />T <br />DUCT MOUNTED FIRE DAMPER <br />SUPPLY DUCT SECTION <br />EF <br />CEILING MOUNTED EXHAUST FAN <br />® <br />RETURN AIR DEVICE <br />VTR = <br />VTW = <br />VTE = <br />VENT THROUGH ROOF <br />VENT THROUGH WALL <br />VENT TO EXTERIOR <br />-6- SUPPLY AIR DEVICE (4 WAY) <br />AIR DISTRIBUTION SCHEDULE <br />MARK <br />MANUF <br />MODEL <br />TYPE <br />SERVICE <br />NECK SZ <br />NOTES <br />AD -I <br />METALAIRE <br />LM <br />CEILING <br />SUPPLY <br />8 X 4 <br />VOLUME DAMPER <br />AD-2 <br />METALAIRE <br />7300 <br />CELING <br />SUPPLY <br />24 X 24 <br />LAY -IN FRAME <br />AD-3 <br />METALAIRE <br />RP -I <br />CEILING <br />RETURN <br />24 X 24 <br />FILTER RACK <br />FAN SCHEDULE <br />FAN MARK <br />EF1 <br />MANUFACTURER <br />BROAN <br />MODEL NUMBER <br />L150MG <br />FAN TYPE <br />CLG EXHAUST <br />FAN CFM <br />160 CFM <br />TOTAL PRESSURE <br />.125 <br />FAN VOLTAGE <br />120/1/60 <br />FAN AMPERAGE <br />1.3 AMPS <br />FIN DIM L X W X H <br />12.25"XI2.25"XIi.75" <br />DUCT OUTLET SIZE <br />6" <br />FAN WEIGHT <br />12.4 LBS <br />NOTES <br />1,2 <br />NOTES: <br />I. SWITCH WITH LIGHTS <br />2. VENT THRU WALL <br />FLEX DUCT <br />0 - 80 CFM = G"0 <br />80 - 170 CFM = 8" 0 <br />171 - 300 CFM = I0"0 <br />301 - 510 CFM = 1210 <br />511 - 750 CFM = 14110 <br />751 - 1100 CFM = 16110 <br />1101 - 1450 CFM = 18110 <br />1451 - 1900 CFM = 20'0 <br />NOTES: <br />I. SIZES BASED ON WIRE HELIX <br />"FLEX MASTER" FLEXIBLE DUCT <br />2. UL LISTING: U-181 / ETL CLASS I <br />AIR DUCT <br />3. FLAME SPREAD: <25 <br />4. SMOKE DEVELOPED: <50 <br />5. MIN R-8 FOR UNCONDITIONED <br />ATTIC SPACE <br />6. MANUFACTURER IS TO BE USED <br />AS A BASIS OF DESIGN. EQUAL <br />IS APPROVED <br />DUCTWORK <br />PECIFICATIONS <br />I. PROVIDE HOT DIPPED GALVANIZED MILD STEEL <br />SHEET METAL FOR EXHAUST AIR AND <br />VENTILATION SYSTEMS AND FOR OTHER <br />SYSTEMS WHERE INDICATED. <br />2. SUPPORTS, FASTENERS AND ACCESSORIES SHALL <br />BE GALVANIZED STEEL. PROVIDE TURNING VANES <br />WITH EXTENDED TRAILING EDGE IN ALL ELBOWS. <br />CONNECTIONS TO FANS SHALL BE MADE WITH 4' <br />INCH FLEXIBLE FIREPROOF CONNECTIONS. SEAL <br />JOINTS WITH GLASS-FAB AND MASTIC OR HIGH <br />VELOCITY SEALANT WHICH BEARS THE U.L. LABEL. <br />3. DUCT GAUGES, CROSS -BREAKING AND SUPPORT <br />SPACING SHALL COMPLY WITH REQUIREMENTS OF <br />THE SMACNA STANDARDS.FLEXIBLE DUCT SHALL <br />BE PRE -INSULATED WITH SEAMLESS VAPOR BARRIER. <br />DUCT SHALL BE UL 181 CLASS I AIR DUCT WITH I" <br />FIBERGLASS INSULATION. MAXIMUM VELOCITY SHALL <br />BE 4000 FPM, SIMILAR TO GENFLEX SLR-25 OR <br />APPROVED EQUAL. <br />4. DUCT ACCESSORIES: <br />INSULATION FIBERGLASS BLANKET WRAP: (MINIMUM <br />R-VALUE OF 8). MANVILLE MICROLITE FIBERGLASS <br />DUCT INSTALLATION ONE AND ONE HALF (1-1/2") <br />INCH THICK. ONE (1) POUND PER CUBIC FOOT <br />DENSITY WITH REINFORCED FOIL SCRIM KRAFT <br />VAPOR BARRIER. <br />5. SMOKE DETECTORS: PROVIDE DUCT MOUNTED <br />SMOKE DETECTORS WHERE SYSTEMS ARE 2000 <br />CFM AND GREATER. DETECTOR SHALL CONFORM <br />TO SECTION 172 OF NFPA PAMPHLET NO 90A. <br />NOTE:AT THE CONTRACTOR'S OPTION, 1-1/2" THICK <br />DUCTBOARD, MINIMUM R-8, CAN BE USED IN <br />PLACE OF SHEET METAL.(SHEET METAL <br />MUST BE USED AT RATED CORRIDORS) <br />MECHANICAL NOTES <br />I. IN GENERAL,PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. <br />2. THE INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY <br />THE SCOPE OF WORK AND ALERT THE CONTRACTOR OF EXISTING CONDITIONS. (IF ANY) <br />THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION <br />OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET <br />FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION WORK <br />BEFORE ANY MECHANICAL CONSTRUCTION WORK BEGINS. <br />3. SHOULD ANY CONFLICTS ARISE, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF THE <br />CONFLICT BEFORE ANY CHANGES ARE MADE. THE CONTRACTOR SHALL OBTAIN WRITTEN <br />APPROVAL BEFORE PROCEEDING WITH ANY CHANGES. <br />4. THIS SYSTEM IS DESIGNED AS A LOW PRESSURE SYSTEM SUBJECT TO VELOCITIES OF 2500 <br />FPM OR LESS AND AN OPERATING PRESSURE OF 2" W.G. OR LESS, POSITIVE OR NEGATIVE. <br />5. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. <br />6. ALL PRIMARY A/C DRAINS TO HAVE APPROVED P-TRAP AND SHALL BE INSULATED PER CODE. <br />7. SECONDARY DRAIN AND/ OR AUX. DRAIN TO HAVE SAFETY SHUT OFF (FLOAT SWITCH). <br />REFRIGERATION LINES (SUCTION LINE) TO HAVE MIN. 11/2' THICK INSULATION. <br />8. PROVIDE LOW VOLTAGE WIRE (T-STAT, CONDENSER WIRE, ETC.) WITH A MINIMUM OF 2 EXTRA <br />WIRES. PROVIDE 18 GAUGE, 8 WIRE TYPICAL. <br />9. PVC CONDENSATE DRAINS TO BE SCH40,SIZES PER PLANS AND/OR LOCAL CODES. SLOPE AS <br />NECESSARY TO PROVIDE POSITIVE DRAINAGE. <br />10. ALL SUPPLY AND RETURN GRILLES AND REGISTERS TO HAVE WHITE FINISHES, ALL SUPPLY <br />GRILLES TO HAVE ADJUSTABLE LOUVERS WITH DAMPERS. <br />II. ALL EXHAUST AND OUTSIDE AIR DUCTS TO BE METAL PER CODE. <br />12. STARTUP SYSTEM WITH NEW FILTERS, REPLACE WITH NEW FILTERS PRIOR TO TENANT <br />OCCUPANCY. <br />13. ALL MECHANICAL EQUIPMENT, MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A <br />PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. <br />14. UPON SYSTEM COMPLETION, PROVIDE A SYSTEM TEST AND BALANCE REPORT PREPARED <br />BY AN INDEPENDANT TEST AND BALANCE AGENCY <br />HVAC KEYNOTES <br />O1 EXISTING RTU AND ROOF CURB <br />ONEW TOILET ROOM FAN AND EXHAUST <br />DUCTWORK - SEE DETAIL THIS SHEET <br />ORETURN AIR TRANSFER DUCTWORK AND <br />GRILLS <br />O PROGRAMMABLE THERMOSTAT <br />ONEW OUTDOOR MINISPLIT UNIT ON <br />WIND RESISTANT WALL BRACKET <br />O6 NEW 9000 BTUH MINISPLIT INDOOR UNIT <br />MOUNT HIGH ON WALL <br />HVAC SCOPE <br />I. HVAC SYSTEM IS NEW. (3 UNITS) <br />2. INSTALL NEW MINI -SPLIT SYSTEM AS <br />SHOWN. MOUNT OUTDOOR UNIT ON <br />WIND -RESISTANT BRACKET (SEE GI.I) <br />3. INSTALL NEW DUCTWORK, SUPPLY AND <br />RETURN GRILLES AS SHOWN. <br />4. PROVIDE NEW OUTSIDE AIR VOLUME <br />AS SHOWN ON CALCULATIONS ON THIS <br />SHEET. <br />5. PROVIDE NEW PROGRAMMABLE THERMOSTATS <br />AS SHOWN. <br />FLEXIBLE DUCT W/ 1-1/2" THICK (F-6) INSULATION & VAPOR <br />BARRIER. MAXIMUM RUN TO BE 8'-0". PROVIDE RIGID DUCT <br />EXTENDING FROM MAIN AS REQUIRED TO MEET MAX. RUN OF <br />FLEXIBLE ELBOW RADIUS SIZED FOR NO LESS THAN <br />R/O = 1.0 <br />UPPER ATTACHMENT <br />PER SMACNA (SEE NOTE <br />#2) <br />MIN. 2" WIDE 22" GALV. STRAP <br />HANGER W/HEMMED EDGES <br />PER SMACNA FIC.3-10 <br />MECHANICAL <br />FLO OR <br />PLAN <br />SCALE 1 /4" = 1'-0" <br />MECHANICAL NOTES: <br />I. ALL MECHANICAL WORK SHALL BE <br />IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE, <br />2020 FLORIDA MECHANICAL CODE <br />AND ALL OTHER APPLICABLE CODES AND ORDINANCES. <br />2. GENERAL CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED FOR A COMPLETE INSTALLATION <br />AND FOR PROPER OPERATION OF <br />MECHANICAL AND PLUMBING SYSTEMS, INCLUDING ALL <br />WORK REQUIRED BY CODE OR REGULATORY AGENCIES. <br />3. REPLACE ALL FILTERS PRIOR TO <br />FINAL INSPECTION. <br />4. PERFORM A SYSTEM TEST AND <br />BALANCE FOR ALL NEW AND ADJUSTMENTS TO EXISTING <br />HVAC EQUIPMENT TO MEET NEW <br />VENTILATION REQUIREMENTS AND MAKE ADJUSTMENTS TO <br />CONFORM TO APPROVED PLAN. SUBMIT FINAL TEST AND BALANCE REPORT TO ARCHITECT <br />AND TENANT. <br />GALV.STEEL ROD OR STRAP 3 <br />SUPPORTS PER SMACNA <br />STANDARDS I <br />(SEE NOTE #2) <br />I' (R-6) STANDARD DUTY FOIL <br />REINFORCED FIBERGLASS <br />W/VAPOR BARRIER SUPPLY <br />DUCT OR SHEET METAL <br />SUPPLY DUCT W/2" THICK <br />WRAP INSULATION (R-6) <br />SQUARE TO ROUND ADAPTER <br />IF REQUIRED. PROVIDE SADDLE 11/2" X 11/2" X 1/8' GALV. <br />OPPOSED BLADE DAMPER ANGLE OF STRAP PER <br />INSULATE TOP PANEL OF SMACNA <br />LAY -IN DIFFUSER NYLON DRAWBAND AND <br />SUSPENDED TYPE MASTIC AT EACH CONNECTION <br />CEILING SYSTEM OR <br />DRYWALL CEILING SEE PLANS FOR GRILLE SIZES <br />NOTES: <br />I. FLEXIBLE DUCT SHALL BE ONE PIECE & SHALL NOT BE SPLICED TOGETHER. <br />2. MAXIMUM SAG = 1/2" PER FOOT BETWEEN SUPPORT POINTS AND 5'-0" MAX OF <br />SUPPORT SPACING. <br />LAY -IN CEILING <br />IQ GALVANIZED STEEL HOUSING <br />® HON ZONTAL DISCHARGE DUCT <br />TION <br />Q OPTIONAL VERTICAL DISCHARGE 0--Y <br />® BACKDRAFT DAMPER <br />® EXTERNAL ELECT ACCESS COVER 9, <br />Q6 24'x24" PERFORATED GRILLE 24' <br />® CEILING TILE WALL CAP OR WALL LOUVER <br />® FLEXIBLE DUCT CONNECTOR NOTE: PROVIDE WALL CAP WITH ALUMINUM <br />® ADJUSTABLE MOUNTING FLANGE CONSTRUCTION, DUCT CONNECTION, <br />BUILT IN DAMPER AND BIRDSCREEN, IN <br />1® VIBRATION ISOLATOR, TOP AND BOTTOM BAKED ENAMEL FINISH. <br />(D 3/16" DIAMETER THREADED HANGER RODS <br />4 TOTAL, SUPPORT FROM BUILDING STRUCTURE. <br />® NUT AND WASHER <br />(Revisions Date T y) <br />Mark A. jonnatti <br />Florida Ak 0010778- <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway 19 N <br />Clearwater, Florida 33765 <br />(727) 725-ARCH <br />(727) 725-2603 fx <br />www.jarch.com <br />info@jarch.com <br />© jonnatti Architecture <br />Incorporated 2021 <br />d: <br />Trub... <br />INTERIOR <br />REMODEL <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />MECHANICAL <br />PLAN <br />(Draw7nMAj <br />Check <br />MAj <br />Date <br />AUG 31, 2021 <br />Scale <br />AS NOTED <br />job No <br />TRULIEVE-ZH <br />Sheet: <br />2 DIFFUSER DETAILS <br />T7 11 NOT TO SCALE <br />EXH FAN DETAIL <br />NOT TO SCALE <br />NOTE: USE SIMILAR WALL CAP AT OUTSIDE AIR INTAKES <br />
The URL can be used to link to this page
Your browser does not support the video tag.