Laserfiche WebLink
GENERAL PLUMBING NOTES: <br />GENERAL <br />I. THE BUILDING SHALL BE PROVIDED WITH THE FOLLOWING SYSTEMS: <br />A. A COMPLETE COLD WATER AND HOT WATER SYSTEM. <br />B. A COMPLETE SANITARY, WASTE AND VENT SYSTEM. <br />2. MANUFACTURERS AND MODEL NUMBERS SHOWN IN THE CRITERIA ARE USED <br />AS A BASIS OF DESIGN, WITH OTHER APPROVED MANUFACTURERS NOTED. <br />SUBSTITUTION FOR THE BASIS OF DESIGN ITEMS IS SUBJECT TO THE <br />WRITTEN APPROVAL OF THE ARCHITECT ON AN APPROVED EQUAL BASIS <br />WATER PIPING <br />I. WATER PIPING SHALL BE TYPE "L" COPPER, WITH 95-5 SILVER SOLDERED <br />JOINTS. CPVC MAY BE USED AS AN ALTERNATE <br />2. INSULATE ALL HOT WATER PIPING WITH I" RIGID FIBERGLASS OR /2" <br />FLEXIBLE FOAM INSULATION (ARMAFLEX). FLEXIBLE FOAM INSULATION <br />SHALL NOT BE SPLIT, AND SHALL BE TAPED AT THE BUTT JOINTS. <br />3. PROVIDE EACH FIXTURE WITH STOPS AND SUPPLIES. EXPOSED STOPS <br />SHALL BE CHROME PLATED. <br />4. PROVIDE WATER HAMMER PROTECTION AT EACH FIXTURE, OR GROUP OF <br />SIMILAR FIXTURES. <br />5. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE. <br />6. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS. PRIMERS SHALL BE <br />LOCATED IN A SERVICEABLE LOCATION. <br />7. STERILIZE WATER PIPING IN ACCORDANCE WITH THE HEALTH DEPARTMENT <br />REGULATIONS AND AMERICAN WATER WORKS ASSOCIATION'S SPECIFICATIONS. <br />SANITARY PIPING <br />I. SANITARY, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC, UNLESS <br />PROHIBITED BY THE LOCAL CODES. <br />2. IF PVC PIPING IS PROHIBITED UNDER -GROUND, BY THE LOCAL CODES, <br />THEN SANITARY WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT <br />CAST IRON. LEADED JOINTS, TYLER "TY-SEAL" AND "NO -HUB" ARE <br />APPROVED SUBJECT TO APPROVAL BY THE BUILDING OFFICAL. <br />3. IF PVC PIPING IS PROHIBITED ABOVE -GROUND BY THE LOCAL CODES, <br />THEN SANITARY, WASTE, AND VENT PIPING SHALL BE SERVICE WEIGHT <br />CAST IRON. LEADED JOINTS, TYLER "TY-SEAL" AND "NO -HUB" ARE <br />APPROVED SUBJECT TO APPROVAL BY THE BUILDING OFFICIAL. <br />4. AN APPROVED ALTERNATE FOR ALL SANITARY, WASTE AND VENT PIPING <br />IS DWV COPPER WITH 50-50 TIN LEADED SOLDERED JOINTS. <br />5. SLOPE OF SANITARY AND WASTE PIPING SHALL BE 1/4' PER FOOT MINIMUM. <br />6. EXPOSED WASTE DRAINS, IN TOILETS, SHALL BE CHROME PLATED <br />BRASS, WITH MATCHING STOPS AND ESCUTCHEONS. <br />7. ROOF PENETRATIONS SHALL BE WITH LEAD PIPE ROOF JACKS. <br />PLUMBING LEGEND <br />NEW COLD WATER <br />C:X--- <br />BALANCING VALVE <br />HW, <br />_ , _ <br />NEW HOT WATER <br />--C,4- <br />CHECK VALVE <br />WHY <br />WALL HYDRANT <br />04 <br />GLOBE VALVE/BALL VALVE <br />HB <br />A- <br />HOSE BIB <br />-� <br />IN LINE PUMP <br />-ID <br />UNION <br />-HWR - <br />HOT WATER RECIRCULATED <br />---�- <br />GATE VALVE <br />-G <br />NATURAL GAS LINE <br />SOIL OR WASTE <br />BFG <br />BELOW FINISHED GRADE <br />- - <br />- - - - - <br />VENT <br />BFF <br />BELOW FINISHED FLOOR <br />CW- <br />EXISTG COLD WATER <br />AFC <br />ABOVE FINISHED CEILING <br />HW - <br />EXISTG HOT WATER <br />ate- <br />P-TRAP <br />- <br />GL <br />GREASE LINE <br />SS <br />SANITARY SEWER <br />WHA <br />QI <br />WATER HAMMER ARRESTOR <br />G <br />WATER METER <br />FD <br />0:1 <br />FLOOR DRAIN <br />C. <br />PIPE TURNED DOWN <br />FS <br />0:1 <br />FLOOR SINK <br />Qo i-- <br />PIPE TURNED UP <br />HD <br />�-H- <br />HUB DRAIN <br />END OF PIPE <br />FCO <br />*+- <br />FLOOR CLEANOUT <br />WH <br />WATER HEATER <br />COTG <br />CLEANOUT TO GRADE <br />P-TRAP <br />WCO <br />WALL CLEANOUT <br />o <br />WALL MOUNTED LAVATORY <br />CO <br />Imo_ <br />END OF LINE CLEANOUT <br />VTR <br />VENT THRU ROOF <br />aOR <br />DRINKING FOUNTAIN <br />NTS <br />NOT TO SCALE <br />WATER COOLER <br />RWL <br />RAIN WATER LINE <br />,WHY <br />WALL HYDRANT <br />Oo <br />TANK TYPE WATER CLOSET <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L <br />1 _________________________________________________________________________� I ____ <br />_________________________ <br />I"CWUGFROMMETER <br />AND BFP SEE CIVIL <br />PLANS <br />PLUMBING FIXTURE SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />MANUF. <br />MODEL NO. <br />CW <br />HW <br />WASTE <br />VENT <br />HEIGHT <br />MAX. WATER <br />COLOR <br />REMARKS <br />USAGE <br />FINISH <br />17"-I9' AFF <br />BEMIS 3155CCST, (OR OTHER SLOW -CLOSE SEAT), SLOAN <br />WCI <br />HANDICAPPED <br />KOHLER <br />KOHLER <br />I/2" <br />3" <br />3" <br />COMPLY WITH <br />1.6 GPF <br />WHITE <br />FLUSHMATE M-101526-F3IPRESSURE ASSIST SYSTEM, <br />WATER CLOSET <br />OR EQUAL <br />K-3611 <br />ADA / ANSI <br />CHROME STOPS/SUPPLIES & LID LOCKS. <br />INSTALL PER ADA & ANSI-A117.1 REQUIREMENTS <br />EWC <br />WATER COOLER <br />(TWO STATION <br />ELKAY <br />ELKAY <br />1/2" <br />2/i2' <br />I " <br />2/2 <br />COMPLY WITH <br />.25 GAL/MIN <br />STAINLESS <br />JR SMITH 0834RL FIXTURE SUPPORT CARRIER. <br />HI-LO) <br />OR EQUAL <br />LZSTL8LC <br />ADA / ANSI <br />STEEL <br />MOUNT UNIT PER ADA & ANSI A117.1 REQUIREMENTS <br />KOHLER <br />1/2' <br />34" TO RIM <br />SYMMONS S20 FAUCET, CHROME STOPS/SUPPLIES <br />LVI <br />HANDICAPPED <br />KOHLER <br />2007, 2030 <br />1/2" <br />WHERE <br />21/2" <br />2�/2" <br />COMPLY WITH <br />.25 GAL/MIN <br />WHITE <br />& P-TRAP WITH TAILPIECE, WATTS USG-B TEMPERING <br />WALL LAVATORY <br />OR EQUAL <br />OR 2861 <br />SHOWN <br />ADA / ANSI <br />DEVICE, J.R. SMITH 0700-D-E BACK TO BACK WALL <br />CARRIER. INSTALL PER ADA& ANSI-A117.I REQUIREMENTS <br />6 GALLON ELECTRIC <br />RHEEM/RUUD <br />RHEEM/RUUD <br />MOUNT IN <br />MOUNT IN BASE CABINET IN DRAIN PAN WITH RELIEF <br />WHI <br />POINT -OF -USE WATER <br />OR EQUAL <br />EGSP6 (208V) <br />3/4" <br />3/4' <br />BASE CABINET <br />DRAIN TO SERVICE SINK - VERIFY ELECTRICAL <br />HEATER <br />VOLTAGE PRIOR TO ORDERING <br />WH2 <br />SINGLE LAVATORY <br />POINT -OF -USE <br />ECOSMART <br />ECOSMART <br />1/2" <br />1/2" <br />WALL MOUNT <br />MOUNT ON WALL BELOW LAVATORY - VERIFY <br />WATER HEATER <br />POU 3.5 <br />ELECTRICAL VOLTAGE PRIOR TO ORDERING <br />SSI <br />FIBERGLASS SERVICE <br />ZURN <br />ZURN <br />3/4" <br />3/4" <br />3" <br />3" <br />FLOOR MOUNT <br />WHITE <br />FLOOR MOP SINK W/ CHICAGO FAUCET #897-CP <br />SINK (MOP SINK) <br />OR EQUAL <br />Z1996-24 <br />OR EQUAL <br />SINGLE BOWL <br />CONTRACTOR'S <br />STAINLESS <br />CHROME STOPS/SUPPLIES & P-TRAP WITH TAILPIECE <br />SS2 <br />KITCHEN SINK <br />OPTION <br />112" <br />1/2" <br />3" <br />3" <br />34" TO RIM <br />.25 GAL/MIN <br />STEEL <br />AND ADA FAUCET. INSTALL PER ADA/ANSI-A117.1 <br />HANDICAPPED REQUIREMENTS <br />PLUMBING KEYNOTES <br />O1 NEW ADA COMPLIANT TOILET ROOM <br />O2 RUN NEW WATER LINE ABOVE CEILING <br />O3 NEW WATER HEATER IN CABINET <br />4O INSTALL NEW HI -LOW ADA ELECTRIC WATER FOUNTAIN <br />O5 EXISTING I' CW SUPPLY LINE WITH S/OFF VALVE <br />PLUMBING SCOPE <br />I. CONSTRUCT ONE TWO ADA COMPLIANT TOILET <br />ROOMS AT THE FRONT LOBBY AS SHOWN. <br />INSTALL ONE NEW HI -LOW ELECTRIC WATER COOLER <br />AND INSTALL ONE NEW BREAKROOM SINK. INSTALL <br />ONE NEW WATER HEATER IN THE BREAKROOM CABINET <br />AS SHOWN. <br />2. CONNECT NEW SANITARY SEWER LINES INTO <br />EXISTING WASTE LINES STUBBED INTO THE <br />BUILDING AS SHOWN <br />3. PROVIDE NEW CPVC WATER SUPPLY LINES TO <br />NEW FIXTURES AS SHOWN. SUPPLY FIXTURES <br />FROM EXISTING 2' WATER LINE WITH SHUT/OFF <br />VALVE STUBBED INTO THE BUILDING <br />4. FIELD VERIFY ALL EXISTING PLUMBING WASTE LINE <br />DEPTHS AND SUPPLY LINE SIZES. MAKE ADJUSTMENTS <br />AS NECESSARY AND AS PER PLUMBING CODE <br />WALL BRACKET <br />WATTS USB-B <br />TEMPERING VALVE <br />WALL BRACKET <br />POINT -OF -USE <br />WATER HEATER <br />WALL BRACKET <br />COLD WATER INLET <br />NOTES; <br />I. WATER TEMPERATURE LIMITING DEVICES SHALL BE USED AT <br />ALL LAVATORIES <br />2. DEVICES SHALL COMPLY WITH ASSE 1070 OR CSA B125.3 <br />3. CONDITION AT EMPLOYEE TOILET ROOM IS SIMILAR <br />COLD <br />WATER <br />SUPPLY <br />O <br />PLUMBING <br />FLOOR PLAN <br />SCALE 1/4" = 1'-0" <br />PLUMBING NOTES. <br />I. ALL PLUMBING WORK SHALL BE IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE, 2020 <br />FLORIDA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES AND ORDINANCES. <br />2. GENERAL CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED FOR A COMPLETE INSTALLATION <br />AND FOR PROPER OPERATION OF MECHANICAL AND PLUMBING SYSTEMS, INCLUDING ALL <br />WORK REQUIRED BY CODE OR REGULATORY AGENCIES. <br />3. SEE SHEET GI.2 FOR ADDITIONAL TOILET ROOM NOTES AND DIMENSIONAL INFORMATION <br />4. ALL PLUMBING FIXTURES SHALL COMPLY WITH FLORIDA BUILDING CODE 2020 401-426. PROVIDE <br />FIXTURE AND FAUCET COMPLIANCE WITH MAXIMUM WATER CONSUMPTION RATES PER <br />FLORIDA BUILDING CODE PLUMBING 604.4 <br />5. PROVIDE TEMPERED HOT WATER FOR ACCESSIBLE HAND WASHING LOCATIONS <br />NEW <br />3" VTR <br />I <br />3" <br />2/2" .- I <br />2i/2"V 2/2"V <br />%_3"V <br />I LVI I <br />I I <br />EWC 3"SS <br />FD <br />3"SS <br />uri 4"SS <br />TEMPERATURE LIMITING <br />2 DEVICE DETAIL <br />1. ij NOT TO SCALE 1.1 <br />NEW <br />3" VTR <br />I <br />• 2'/2"V <br />21/2 11 V I I `•i <br />LVI I ! 3 V �21/2"V EXISTING 4" SAN SEWER <br />TO UTILITY <br />I <br />3"SS <br />FD C <br />EEX <br />3"SS I FO 2'/2"V <br />WCi �2'/z"V '. <br />21/2"SS I SSI ! <br />SS2 >0121/2"SS <br />WCO <br />WASTE RISER <br />NOT TO SCALE <br />Revisions Date y <br />Mark A. Jonnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway 19 N <br />Clearwater, Florida 33765 <br />(727) 725-ARCH <br />(727) 725-2603 fx <br />www.jarch.com <br />info@jarch.com <br />Jonnatti Architecture <br />Incorporated 2021 <br />g <br />0 0 0 41 <br />INTERIOR <br />REMODEL <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />PLUMBING <br />PLAN <br />(Drawn <br />MAJ <br />Check <br />MAJ <br />Date <br />AUG 31, 2021 <br />Scale <br />AS NOTED <br />Job No <br />I TRULIEVE-ZH <br />'l Ol <br />Sheet: <br />of <br />