Laserfiche WebLink
L L. .. III I <br />I <br />2 <br />I 3 I <br />0 <br />It <br />C <br />m <br />n <br />1 ENLARGED LIFE SAFETY PLAN - LEVEL 1 NG <br />SCALE: 1/8" = l'—O" <br />LIFE SAFETY LEGEND <br />FE <br />FIRE EXTINGUISHER <br />FEC <br />FIRE EXTINGUISHER CABINET <br />FHC <br />FIRE HOSE CABINET & EXTINGUISHER CABINET <br />z <br />HAZARDOUS AREAS <br />FB <br />FIRE BLANKET <br />Q <br />SMOKE DETECTOR <br />Q <br />HEAT DETECTOR <br />EXIT LIGHT <br />1 <br />EXIT LIGHT W/ DIRECTIONAL ARROW <br />4 <br />FIRE ALARM HORN/ STROBE <br />F❑ <br />FIRE ALARM MANUAL PULL STATION <br />© <br />FIRE ALARM STROBE <br />9sP <br />STAND PIPE <br />® <br />CARD READER <br />2A <br />SMOKE ZONE <br />SUITE: 1-A <br />SUITE NAME <br />44 <br />EXIT ARROW / CLEAR WIDTH <br />ETD <br />EXIT TRAVEL DISTANCE <br />CPT <br />COMMON PATH OF TRAVEL <br />THE FOLLOWING REQUIREMENTS & REFERENCES NOTED ARE BASED UPON <br />a. <br />FULLY SPRINKLED BUILDING, AND <br />b. <br />EXISTING HEALTHCARE OCCUPANCY - 2009 NFPA 101, FLORIDA <br />SPECIFIC EDITION <br />c. <br />2007 NFPA 80 <br />LIMITS OF NON SLEEPING SUITES LIMITS OF SLEEPING SUITES <br />(NFPA 101 PAR 19-2.5.7) (NFPA <br />101 PAR 19-2.5.7) <br />ALL CORRIDOR WALLS ARE TO BE SMOKE TIGHT. <br />GASKETING OF DOORS SHOULD NOT BE NECESSARY <br />(NFPA 101 PAR A.8.4.3.4) (NFPA 101 PAR 19.3.6.3.1) <br />SMOKE RESISTANT CORRIDORS WITH PARTITIONS EXTENDED TO DECK ABOVE <br />■ <br />(NFPA 101 Par 19.3.6.3.1) <br />■ <br />■ <br />a. 20 MINUTE RATED 13/4" SOLID CORE WOOD DOOR, FRAME AND WINDOWS <br />(19.3.6.3.1) <br />■ <br />b. POSITIVE LATCHING REQUIRED <br />(A19.3.6.3.5(1)) <br />■ <br />■ <br />c. NON RATED PROTECTIVE PLATE ON DOORS, UNLIMITED IN HEIGHT, ARE PERMITTED <br />(19.3.6.3.12) <br />d. DOOR CLOSER NOT REQUIRED <br />■ <br />e. MAX 118" GAP AT HINGE, LATCH & TOP ON PULL SIDE OF SINGLE DOORS AND AT <br />■ <br />MEETING EDGES OF PAIR OF DOORS <br />(NFPA 80 6.3.1.7 <br />■ <br />f. MAX.1" UNDERCUT FROM BTM OF DOOR TO FINISH FLOOR <br />(19.3.6.3.4) <br />■ <br />g. PERIMETER WALLS OF AREAS OPEN TO CORRIDOR CONSTRUCTED TO MATCH <br />■ <br />■ <br />CORRIDOR PARTITIONS AND CEILING <br />(8.4.2) <br />h. FIRE OR SMOKE DAMPERS NOT REQUIRED <br />(19.3.7.4) <br />_ <br />ONE HOUR FIRE WALL ASSEMBLY (NFPA 101 Par 8.3.4.2) <br />a. 3I4 HOUR RATED DOOR & FRAME <br />(TABLE 8.3.4.2) <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(8.3.3.3) <br />c. POSITIVE LATCHING REQUIRED <br />(19.3.6.3.5) <br />LE <br />d. NON RATED PROTECTIVE PLATE UP TO 48" <br />(19.3.2.1.4) <br />■ <br />e. MAX 118" GAP AT HINGE, LATCH & TOP ON PULL SIDE <br />(8.5.4.1 & NFPA 80 6.3.1.7) <br />■ <br />f. MAX 3l4" DOOR UNDERCUT <br />(NFPA 80 4.8.4.1) <br />g. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 80 4.4.5) <br />h. FIRE DAMPERS REQUIRED <br />(8.3.5.6.1) <br />i. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />■ <br />TWO HOUR FIRE WALL ASSEMBLY (NFPA 101 Par 8.3.4.2) <br />a. 1112 HOUR RATED DOOR & FRAME <br />(TABLE 8.3.4.2) <br />■ <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(8.3.3.3) <br />c. POSITIVE LATCHING REQUIRED <br />(19.3.6.3.5) <br />— <br />d. RATED PROTECTIVE PLATE REQUIRED IF TOP OF PLATE IS GREATER <br />THAN 48" ABOVE BOTTOM OF DOOR <br />(19.3.2.1.4) <br />e. MAX 118" GAP AT HINGE, LATCH & TOP ON PULL SIDE <br />(8.5.4.1 & NFPA 80 6.3.1.7) <br />f. MAX 314" DOOR UNDERCUT <br />(NFPA 80 4.8.4.1) <br />—_ <br />g. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 80 4.4.5) <br />■ <br />h. 11/2 HOUR FIRE DAMPER REQUIRED <br />(8.3.5.6.1) <br />i. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />ONE HOUR FIRE/SMOKE BARRIER WALL ASSEMBLY (NFPA 101, <br />Par 19-3.7) <br />a. 20 MIN. RATED SOLID CORE WOOD DOOR OR STEEL DOOR & FRAME <br />(TABLE 8.3.4.2) <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(19.3.7.8 & 8.5.4.4) <br />■ <br />c. POSITIVE LATCHING NOT REQUIRED AT CROSS CORRIDOR DOORS <br />(19.3.7.8) <br />d. NON RATED PROTECTIVE PLATE UNLIMITED IN HEIGHT IS PERMITTED <br />(19.37.6.1) <br />■_ <br />e. MAX 118" GAP AT HINGE, LATCH & TOP ON PULL SIDE OF SINGLE DOORS <br />■ <br />AND AT MEETING EDGES OF PAIR OF DOORS <br />(8.5.4.1 & NFPA 80 6.3.1.7) <br />f. EXISTING ASTRAGALS SHALL REMAIN <br />■ <br />g. MAX 314" DOOR UNDERCUT <br />(NFPA 80 4.8A.1) <br />h. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 80 4.4.5) <br />■ <br />■ <br />i. FIRE/SMOKE DAMPER(S) REQUIRED <br />(8.5.5.2) <br />j. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />TWO HOUR FIRE/SMOKE BARRIER WALL ASSEMBLY (NFPA 101, <br />Par 19.3.7) <br />a. 1112 HOUR RATED DOOR & FRAME <br />(TABLE 8.3.4.2) <br />b. SELF CLOSING OR AUTOMATIC CLOSING REQUIRED <br />(19.3.7.8 & 8.5.4.4) <br />c. POSITIVE LATCHING REQUIRED <br />(19.3.7.8) <br />d. RATED PROTECTIVE PLATE REQUIRED IF TOP OF PLATE IS GREATER <br />■ <br />THAN 16" ABOVE BOTTOM OF DOOR <br />(NFPA 80 6.4.5) <br />e. MAX 1l8" GAP AT HINGE, LATCH & TOP ON PULL SIDE OF SINGLE DOORS <br />■ <br />AND AT MEETING EDGES OF PAIR OF DOORS <br />(8.5.4.1 & NFPA 80 6.3.1.7) <br />f. EXISTING ASTRAGALS SHALL REMAIN <br />g. MAX 314" DOOR UNDERCUT <br />(NFPA 80 4.8.4.1) <br />h. FIRE GLAZING SIZE LIMITED TO AREA TESTED <br />(NFPA 80 4.4.5) <br />■ <br />i. FIREISMOKE DAMPER(S) REQUIRED <br />(8.5.5.2) <br />j. NO LOUVERS IN DOORS <br />(8.4.3.3) <br />106 WEST NORTH BAY STREET I TAMPA, FL 33603 <br />http://cjaegroup.com <br />I hill! 11"I'll I I <br />STAMPS AND APPROVALS <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A <br />DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF FLORIDA. <br />TO THE BEST OF MY KNOWLEDGE, THESE PLANS AND SPECIFICATIONS <br />COMPLY WITH THE APPLICABLE BUILDING CODES. <br />CARLA J. HARVEY; LICENSE NO: AR9508B <br />In <br />Advento'H'ealth <br />Zephyrhills <br />PROJECT NAME <br />ADVENTHEALTH ZEPHYRHILLS <br />ROOM 6 X-RAY REPLACEMENT <br />PROJECT LOCATION <br />7050 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT NUMBER <br />2021-009 <br />PROJECT PHASE <br />100% CONSTRUCTION DOCUMENTS <br />ISSUE DATE <br />AUGUST 18, 2021 <br />REVISIONS LIST <br />NO. I DATE DESCRIPTION <br />SHEET TITLE <br />ENLARGED LIFE SAFETY PLAN <br />SHEET NO. <br />LSm02 <br />KEY PLAN N0 <br />