2 <br />3 <br />4 <br />U <br />C <br />1 <br />0 <br />00 01 15 LIST OF DRAWINGS <br />COMPLETE LIST OF DRAWINGS IN CONTRACT SET WITH DRAWING NO., SHEET DESCRIPTION AND DRAWING DATE. <br />00 10 00 SOLICITATION FOR BIDS <br />BID FORM / REQUEST FOR PROPOSAL (RFP) DOCUMENT BY OWNER OR OWNER'S REPRESENTATIVE; PROVIDED <br />BY OWNER OR OWNER REP. <br />00 52 00 AGREEMENT FORMS <br />OWNER AGREEMENT TO BE BETWEEN OWNER AND CONTRACTOR. REFER TO RFP OR BID REQUEST. <br />00 70 00 CONDITIONS OF THE CONTRACT <br />PROVIDED BY OWNER OR OWNER REPRESENTATIVE. <br />01 25 00 SUBSTITUTION PROCEDURES <br />ALL PRODUCTS MUST MATCH CONTRACT DOCUMENTS OR SPECIFICATIONS. ANY SUBSTITUTIONS MUST BE <br />SUBMITTED AND APPROVED BY ARCHITECT OR ENGINEER OF RECORD. SUBSTITUTIONS MUST PROVIDE MONETARY <br />OR SCHEDULE VALUE TO THE PROJECT. <br />01 29 00 PAYMENT PROCEDURES <br />'APPLICATIONS FOR PAYMENT' SCHEDULE AND REQUIREMENTS MUST BE COORDINATED WITH OWNER OR OWNER <br />REPRESENTATIVE. ARCHITECT IS REQUIRED TO REVIEW ALL APPLICATIONS FOR PAYMENT PRIOR TO SUBMISSION <br />TO OWNER FOR FINAL PAYMENT APPROVAL. FULL SCHEDULE OF VALUES MUST BE INCLUDED, ALONG WITH <br />PERCENTAGE COMPLETE / PAYMENT REQUESTED AMOUNTS. PROVIDE INDIVIDUAL TRADES PAY APPLICATIONS AS <br />SUPPORT. <br />01 32 00 CONSTRUCTION PROGRESS DOCUMENTA11ON <br />CONTRACTOR MUST PROVIDE REGULAR RECORDED DOCUMENTATION OF CONSTRUCTION PROGRESS. FREQUENCY <br />TO BE DETERMINED BY OWNER OR OWNER REPRESENTATIVE. PHOTOGRAPHIC DOCUMENTATION IS REQUIRED. <br />IN —WALL PHOTOGRAPHS MUST BE TAKEN PRIOR TO CLOSING —UP OF ANY WALLS. <br />PROJECT SCHEDULE, INCLUDING MILESTONE DATES AND PROGRESS COMPLETION, SHALL BE INCLUDED. <br />01 50 00 TEMPORARY FACILITIES AND CONTROLS <br />TEMPORARY UTILITIES AND UTILITY CONNECTIONS FOR CONSTRUCTION MUST BE COORDINATED WITH OWNER. <br />01 56 10 TEMPORARY BARRIERS AND ENCLOSURES — INFECTION CONTROL <br />REFER TO INFECTION CONTROL RISK ASSESSMENT FORM, BY OWNER. RISK ASSESSMENT DOCUMENTATION IS <br />INCLUDED IN THIS DOCUMENT PACKAGE; ASSESSMENT MUST BE VERIFIED AND CONFIRMED BY OWNER'S <br />INFECTION CONTROL DEPARTMENT. <br />01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS DISCOVERY OF WATER DAMAGE AND ORGANIC CONTAMINANTS <br />CONSULTANTS AND CONTRACTORS CONDUCTING WORK ARE REQUIRED TO NOTIFY OWNER OF ANY WATER <br />DAMAGE OR CONCERNS OF ORGANIC CONTAMINANTS. ANY REQUIRED TESTING SHALL BE PERFORMED BY <br />OWNER. <br />01 58 13 TEMPORARY PROJECT SIGNAGE <br />COORDINATE ALL SIGNAGE REQUIREMENTS AND LANGUAGE WITH OWNER. IMMEDIATE CONTACT INFORMATION <br />MUST BE PROVIDED FOR EMERGENCY USE. <br />01 70 00 EXECUTION AND CLOSEOUT DOCUMENTS <br />PROVIDE FINAL AS —BUILT DOCUMENTATION FOR ALL DISCIPLINES TO THE ARCHITECT AND OWNER OR OWNER <br />REPRESENTATIVE. <br />PROVIDE OWNER MANUALS AND PRODUCT DATA FOR ALL MAJOR MECHANICAL, PLUMBING AND ELECTRICAL <br />EQUIPMENT, AS DEFINED IN THE PROJECT DOCUMENTS. <br />PROVIDE AND COORDINATE FINAL WARRANTY INFORMATION TO THE OWNER, AS DEFINED IN THE PROJECT <br />DOCUMENTS. <br />COORDINATE FINAL WALKTHROUGHS AND PUNCH LIST WITH ARCHITECT, ENGINEER AND OWNER OR OWNER <br />REPRESENTATIVE. FINAL DOCUMENTATION OF ACCEPTANCE OF WORK BY ARCHITECT/ENGINEER MUST BE <br />PROVIDED TO OWNER. <br />02 41 19 SELECTIVE DEMOLITION <br />COORDINATION DEMOLITION PRACTICES WITH OWNER OR OWNER REPRESENTATIVE. SCHEDULE DEMOLITION <br />ACTIVITIES TO BE OF LEAST IMPACT TO REGULAR OPERATIONS BY OWNER. PROTECTIVE MEASURES SHALL BE <br />PUT INTO PLACE, WITH CLEAR COMMUNICATION AND PROCESSES/PROCEDURES COORDINATED WITH OWNER OR <br />OWNER REPRESENTATIVE. <br />CONTRACTOR SHALL FOLLOW MATERIAL DISPOSAL WITH HOSPITAL STANDARD PROCEDURES. ALL ITEMS/ <br />MATERIAL TO BE REMOVED/DISPOSED MUST BE PROTECTED WHILE IN TRANSIT THROUGH THE HOSPITAL TO <br />FINAL DISPOSAL AREA. <br />02 26 23 ASBESTOS ASSESSMENT <br />REQUIRED FOR ALL PROJECTS WITHIN THE HOSPITAL UNLESS RECENT SURVEY IS ON RECORD, BY OWNER. <br />VERIFY TESTING COMPLETION BY OWNER. <br />02 87 13 MOLD REMEDIATION <br />COORDINATE ALL REQUIRED MOLD REMEDIATION WITH OWNER. REMEDIATION PROCESS MUST BE COORDINATED <br />WITH OWNER, INFECTION CONTROL DEPARTMENT, USER GROUPS. REMEDIATION MUST BE COMPLETED BY A <br />LICENSED PROFESSIONAL. <br />03 30 00 CAST —IN —PLACE CONCRETE <br />ALL CONCRETE POURS SHALL BE INSPECTED BY REGULATORY AUTHORITIES, OWNER REPRESENTATIVE, <br />ARCHITECT AND STRUCTURAL ENGINEER, AS APPROPRIATE, BEFORE POURS. ALLOW A MINIMUM OF 72—HOUR <br />NOTICE IF POURS ARE TO OCCUR WITHIN THE EXISTING HOSPITAL BUILDING TO ALLOW FOR SAFETY MEASURES <br />AND COORDINATION WITH OPERATIONS. <br />FOR ANY NEW CONCRETE HOUSEKEEPING PADS TO BE POURED AND ANCHORED TO AN EXISTING CONCRETE <br />SLAB, ALL PAINT, SEALERS AND FINISHES MUST BE REMOVED BEFORE DOWELING AND POURING NEW SLAB, <br />UNLESS OTHERWISE SPECIFIED. <br />03 82 13 CONCRETE CORE DRILLING <br />ALL CORE DRILL LOCATIONS MUST BE VERIFIED AND CONFIRMED WITH STRUCTURAL ENGINEER PRIOR TO WORK. <br />ALL CORE DRILLING MUST BE COORDINATED WITH OWNER OR OWNER REPRESENTATIVE TO COMPLY WITH <br />ICRA/SAFETY MEASURES AND TO MINIMIZE IMPACT ON EXISTING OPERATIONS. <br />NOT USED <br />05 10 00 STRUCTURAL METAL FRAMING <br />REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL STEEL INFORMATION. <br />PROVIDE 'UNISTRUT' SYSTEMS FOR STRUCTURAL RAIL SUPPORT SYSTEM, DELEGATED DESIGN. REFER TO AGFA <br />DRAWINGS AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. COORDINATE FINAL CEILING RAIL <br />SUPPORT SYSTEM WITH AGFA EQUIPMENT, CONFIRM WITH AGFA REPRESENTATIVE FOR FINAL APPROVAL OF <br />SYSTEM AND INSTALLATION LOCATION. <br />06 10 53 MISCELLANEOUS ROUGH CARPENTRY <br />ALL BLOCKING AND CONCEALED WOOD FRAMING TO BE FIRE —RETARDANT TREATED, COMPLYING WITH AWPA C20 <br />AND AWPA C27. <br />06 40 23 INTERIOR ARCHITECTURAL WOODWORK <br />MINIMUM AN PREMIUM GRADE MATERIALS AND WORKMANSHIP <br />— ALL CABINETS TO BE MADE OF PLYWOOD, NO EXCEPTIONS <br />— ALL BASE CABINETS TO BE INSTALLED OVER SHEET VINYL FLOORING, SHALL RUN CONTINUOUS UNDER BASE <br />CABINET AND FLASH —COVED TO BACK WALL. <br />— DRAWER CONSTRUCTION SHALL BE ALL PLYWOOD; NO PARTICLE BOARD AND NO METAL SIDES. <br />— LEG SUPPORTS SHALL BE LAMINATED PLYWOOD <br />— ALL BASE CABINET COUNTERTOP OUTSIDE CORNERS SHALL BE 2" RADIUS. <br />— WALL CABINETS MUST HAVE LAMINATED FILLER PIECE TO CEILING, UNLESS OTHERWISE NOTED. <br />— INSIDE OF CABINET WHITE LINER ONLY, NO MELAMINE <br />— SOLID SURFACE COUNTERTOPS — CORIAN, WILSONART — SEE FINISH SCHEDULE FOR DETAILS <br />PLASTIC LAMINATE — FORMICA, ARBORITE, WILSONART — SEE FINISH SCHEDULE FOR DETAILS <br />— CABINET HARDWARE — TO MATCH EXISTING, OR <br />HINGES — HINGES BLUM 120 DEG PRESS —IN, BLUM—BLlT5550 <br />BACK PLATE — BACK PLATE — OMM, BLUM BACK PLATE BL-175H7100 <br />DRAWER GLIDES — KNAPE/VOGT DRAWER GLIDES — FULL EXTENSION KV8400 SERIES <br />PULLS — BRUSHED CHROME WIRE PULLS 96MM <br />COUNTERTOP SUPPORT BRACKETS — RAKKS <br />FOR COUNTERS 12" DEEP — STYLE EC-0808; FOR COUNTERS 18" DEEP — STYLE EC0812; FOR COUNTERS <br />24" DEEP - EH-1818 WITH RADIUS; FOR COUNTERS 30" DEEP - EH-1824 WITH RADIUS <br />ADDITIONAL SUPPORT ANGLE RAKKS EH —CS 2 X 2 X 1 /8" ALUMINUM ANGLE CLEAT STOCK. <br />— GROMMETS — 3" DIAMETER, WITH RIM AND REMOVABLE PLASTIC COVER (BLACK) <br />07 81 00 APPLIED FIREPROOFING <br />FIREPROOFING EXISTING STRUCTURE AT CORE DRILL OR PENETRATION LOCATIONS MUST MATCH EXISTING <br />FIREPROOFING METHOD. <br />07 84 10 PENETRATION FIRESTOPPING <br />ALL FIRESTOPPING MUST BE UL SYSTEM, AND MUST BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. <br />- PENETRATIONS IN FIRE —RESISTANCE —RATED WALLS: PROVIDE PENETRATION FIRESTOPPING WITH RATINGS <br />DETERMINED PER ASTM E 814 OR UL 1479. <br />— PENETRATIONS IN HORIZONTAL ASSEMBLIES: PROVIDE PENETRATION FIRESTOPPING WITH RATINGS <br />DETERMINED PER ASTM E 814 OR UL 1479. F—RATING SHALL BE AT LEAST 1—HOUR, BUT NOT LESS THAN <br />THE FIRE —RESISTANCE RATING OF THE CONSTRUCTION PENETRATED. T—RATING SHALL BE AT LEAST <br />1—HOUR, BUT NOT LESS THAN THE FIRE —RESISTANCE RATING OF CONSTRUCTION PENETRATED EXCEPT FOR <br />FLOOR PENETRATIONS WITHIN THE CAVITY OF A WALL. <br />— PENETRATIONS IN SMOKE BARRIERS: PROVIDE PENETRATION FIRESTOPPING WITH RATINGS DETERMINED PER <br />UL 1479. <br />APPROVED MANUFACTURERS — HILTI, STI, 3M <br />BOD — 3M FIRE BARRIER CP 25WBt SEALANT <br />UL—SYSTEM LABEL SHALL BE AFFIXED ADJACENT TO THE PENETRATION. <br />07 84 40 FIRE —RESISTIVE JOINT SYSTEMS <br />APPROVED MANUFACTURERS — HILTI, STI, 3M <br />07 92 00 JOINT SEALANTS <br />FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL JOINT SEALANT INSTALLATION. <br />PROVIDE SILICONE, URETHANE OR LATEX JOINT SEALANTS, AS APPROPRIATE, FOR SPECIFIC INSTALLATION TYPE. <br />— SILICONE JOINT SEALANT : CONTROL AND EXPANSION JOINTS IN OVERHEAD SURFACES; OTHER JOINTS AS <br />NOTED. <br />APPROVED MANUFACTURERS: DOW CORNING CORP 790; GE ADVANCED MATERIALS SILPRUF LM SCS2700; <br />TREMCO INC SPECTREM 1 <br />— URETHANE JOINT SEALANT. INTERIOR JOINTS IN HORIZONTAL TRAFFIC SURFACES — ISOLATION JOINTS IN <br />CAST —IN —PLACE CONCRETE SLABS; CONTROL AND EXPANSION JOINTS IN TILE FLOORING; OTHER JOINTS AS <br />NOTED. <br />APPROVED MANUFACTURERS: BASF BUILDING SYSTEMS SONOLASTIC NP 2; PECORA CORP DYNATRED; <br />TREMCO INC VULKEM 227 <br />— ACRYLIC —LATEX SEALANT. INTERIOR JOINTS IN VERTICAL SURFACES AND HORIZONTAL NONTRAFFIC <br />SURFACES THAT WILL BE FIELD —PAINTED — PERIMETER JOINTS BETWEEN INTERIOR WALL SURFACES AND <br />FRAMES OF INTERIOR DOORS, ACCESS DOORS AND WINDOWS; OTHER JOINTS AS NOTED. <br />APPROVED MANUFACTURERS: BASF BUILDING SYSTEMS SONOLAC; BOSTIK INC CHEM—CALK 600; TREMCO <br />INC TREMFLEX 834 <br />— MILDEW —RESISTANT SILICONE SEALANT: MILDEW —RESISTANT JOINTS IN VERTICAL SURFACES AND HORIZONTAL <br />NON -TRAFFIC SURFACES — JOINTS BETWEEN PLUMBING FIXTURES AND ADJOINING WALLS, FLOORS AND <br />COUNTERS; TILE CONTROL AND EXPANSION JOINTS; OTHER JOINTS AS NOTED. <br />APPROVED MANUFACTURERS: BASF BUILDING SYSTEMS OMNIPLUUS; DOW CORNING CORP 786 MILDEW <br />RESISTANT, TREMCO INC TREMSIL 200 SANITARY <br />08 12 13 HOLLOW METAL FRAMES <br />PROVIDE 1/16" LEAD —LINED EQUIVALENT GLAZING AND FRAME PER PHYSICIST REPORT. <br />ENAMEL PAINTED FRAME <br />APPROVED MANUFACTURER: RAY —BAR LEAD —LINED FRAME; RADIATION PROTECTION PRODUCTS (RPP) <br />08 56 49 GLAZING <br />PROVIDE 1/16" LEAD —LINED EQUIVALENT GLAZING AND FRAME PER PHYSICIST REPORT. <br />APPROVED MANUFACTURER: RAY —BAR LEAD —LINED VIEW WINDOWS; RADIATION PROTECTION PRODUCTS (RPP) <br />09 06 00 SCHEDULES FOR FINISHES <br />REFER TO INTERIOR FINISH PLAN OR INTERIOR FINISH SCHEDULE IN THE DOCUMENTS FOR INTERIOR FINISH <br />SCHEDULE. <br />09 21 16 GYPSUM BOARD ASSEMBLIES <br />MUST COMPLY WITH ASTM C 36/C 36M OR ASTM C 1396/C 1396M, AS APPLICABLE TO TYPE OF GYPSUM <br />BOARD AND WHICHEVER IS MORE STRINGENT. <br />5/8" TYPE X GYPSUM BOARD — TYPICAL <br />MOISTURE AND MOLD RESISTANT TYPE — ASTM D 3273, SCORE OF 10 AS RATED ACCORDING TO ASTM D 3274.. <br />LONG EDGES TAPERED — WET WALLS (BOD "PURPLE BOARD" BY US GYPSUM) <br />PROVIDE LEAD —LINED 1/16" GYPSUM WALL BOARD, AS REQ'D, REFER TO PHYSICIST REPORT. <br />09 22 16 NON—STRUCTURAL METAL FRAMING <br />20 GA STEEL STUDS FOR INTERIOR FRAMING AT 16" OC <br />20 GA STEEL STUDS FOR HEADERS AND FOOTERS <br />DOUBLE 20 GA STEEL STUDS FOR FRAMING OF DOORS AND WINDOWS <br />FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR FRAMING GAUGE OF LEAD —LINED DOORS OR DOORS GREATER <br />THAN 3'-6". <br />09 30 00 11LING <br />REFER TO FINISH SCHEDULE <br />USE MANUFACTURER'S RECOMMENDED ADHESIVE PROGRAM/SYSTEM. <br />09 51 13 ACOUSTIC PANEL CEILINGS <br />ACT1 — REFER TO FINISH SCHEDULE <br />APPROVED MANUFACTURERS: ARMSTRONG, SQUARE LAY —IN <br />METAL SUSPENSION SYSTEM: <br />BOD: PRELUDE XL 15/16" EXPOSED TEE SYSTEMS, OR EQUAL <br />APPROVED MANUFACTURERS: ARMSTRONG <br />09 65 00 RESILIENT FLOORING <br />SHEET VINYL B.O.D.: REFER TO FINISH SCHEDULE <br />ADHESIVES: PER MANUFACTURER'S RECOMMENDATION <br />RUBBER BASE B.O.D.: JOHNSONITE/TARKETT DURACOVE THERMOPLASTIC RUBBER 1/8"; 4" HT TYPICAL <br />09 72 00 WALL COVERINGS <br />WALL PROTECTION BY INPRO CORP.; 0.08" THICKNESS. <br />REFER TO FINISH SCHEDULE FOR DETAILS AND LOCATIONS <br />09 91 23 INTERIOR PAINTING <br />REFER TO INTERIOR FINISHES DRAWINGS FOR PAINT COLORS/LOCATIONS <br />LOW VOC PAINT REQUIRED <br />SHERWIN WILLIAMS PROMAR 200, EGGSHELL (SEMIGLOSS AT DOOR/WINDOW FRAMES) <br />NEW WALLS: 1 COAT PRIMER, 2 COATS FINISH (MINIMUM) <br />EXISTING WALLS: 1 COAT KILZ OR PRIMER, 2 COATS FINISH <br />FRAMES: SEMIGLOSS; 1 COAT PRIMER, 2 COATS FINISH <br />REFER TO FINISH SCHEDULE FOR ADDITIONAL DETAILS <br />10 14 00 SIGNAGE <br />NOT USED (EXISTING TO REMAIN) <br />10 26 23 PROTECTIVE WALL COVERING <br />INPRO — 160 CG HIGH IMPACT CORNER GUARDS (2") <br />10 28 13 TOILET ACCESSORIES <br />GRAB BARS (GB) — EXISTING TO REMAIN <br />MIRROR (MIR) — NEW — CFCI — BOBRICK B-293-1836 <br />SOAP DISPENSER (SD) — EXISTING TO REMAIN <br />TOILET PAPER DISPENSER (TPD) — EXISTING TO REMAIN <br />PAPER TOWEL DISPENSER (PTD) — EXISTING TO REMAIN <br />SHELF — EXISTING TO REMAIN <br />10 44 00 FIRE PROTECTION SPECIALTIES <br />NOT USED (EXISTING TO REMAIN) <br />11 77 00 REFER TO EQUIPMENT PACKAGE PROVIDED BY VENDOR 'AGFA' TITLED "DR 800 DIGITAL HIGH FREQUENCY <br />UNIVERSAL R/F SYSTEM SUITE" DATED 05/03/2021. <br />REVIEW ALL VENDOR —PROVIDED EQUIPMENT PLANS TO ENSURE COORDINA11ON WITH THIS CONTRACT DOCUMENT <br />PACKAGE. <br />12 35 70 HOSPITAL CASEWORK <br />REFER TO DIVISION 06 AND DRAWINGS FOR INFORMATION. <br />13 49 00 RADIATION PROTECTION <br />OWNER TO PROVIDE LEAD SHIELDING REPORT BY PHYSICIST BOTH PRIOR TO AND POST -CONSTRUCTION. <br />REFER TO SPECIFICATIONS DIVISIONS 08 AND 09, AND DRAWINGS, FOR ADDITIONAL INFORMATION ABOUT <br />SHIELDING REQUIREMENTS. <br />ALL LEAD SHIELDING SHALL BE CONTINUOUS UP TO 7'-0". <br />NOT USED <br />106 WEST NORTH BAY STREET I TAMPA, FL 33603 <br />http://cjaegroup.com <br />STAMPS AND APPROVALS <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT i AM A <br />DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF FLORIDA. <br />TO THE BEST OF MY KNOWLEDGE, THESE PLANS AND SPECIFICATIONS <br />COMPLY WITH THE APPLICABLE BUILDING CODES. <br />CARLA J. HARVEY, LICENSE NO: AR95088 <br />PROJECT NAME <br />ADVENTHEALTH ZEPHYRHILLS <br />ROOM 6 X-RAY REPLACEMENT <br />PROJECT LOCATION <br />7050 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT NUMBER <br />2021-009 <br />PROJECT PHASE <br />100% CONSTRUCTION DOCUMENTS <br />ISSUE DATE <br />AUGUST 18, 2021 <br />REVISIONS LIST <br />(�NO. I DATE DESCRIPTION <br />SHEET TITLE <br />PROJECT SPECIFICATIONS <br />SHEET NO. <br />Amol <br />