2 I 3 <br />4 I 5 <br />I <br />C <br />A <br />A <br />a <br />co <br />N <br />io <br />N <br />O <br />N <br />N <br />CEP <br />PROPOSED CONDUIT ROUTING FROM NEW ELEC ROOM TO EXISTING <br />CEP. RUN CONDUIT UP BUILDING THRU EXISTING ELEC/MECH ROOM <br />AND THEN UNDERGROUND TO EXISTING CEP. CONDUIT RUN IS <br />APPROXIMATELY 200 FEET. CONTRACTOR SHALL FIELD VERIFY ALL <br />EXISTING CONDITIONS TO DETERMINE EXACT CONDUIT ROUTING AND <br />LENGTH. <br />OPEN COURTYARD <br />LEVEL 1 RENOVATION - PHASE 1 - POWER <br />SCALE: 1/8" = 1'-0" <br />AREA OF WORK <br />PER OWNER REQUEST, REMOVE <br />SCOPE OF WORK IN THE BAKERY <br />AREA FROM PHASE 1: REMOVAL OF <br />EXISTING HOODS, CONSTRUCTION <br />OF WALL AND DOOR, <br />CEILING, LIGHTS, POWER, EF1-1, <br />AND ASSOCIATED DUCTWORK TO <br />ENCLOSE POT/ DISHWASH AREA. <br />THIS PORTION OF WORK WILL BE <br />MOVED TO LATER PHASE (PHASE 2), <br />REVISED PHASING PLAN (A/MEP/FP) <br />TO BE ISSUED UPON OWNER <br />NOTICE -TO -PROCEED TO START OF <br />PHASE 2 CONSTRUCTION. <br />OPEN AIR BREEZEWAY <br />A <br />OPEN AIR BREEZEWAY <br />GENERAL POWER PLAN NOTES <br />1 VERIFY AND COORDINATE EXACT ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT WITH <br />MANUFACTURER'S RECOMMENDATIONS PRIOR TO INSTALLATION OF EQUIPMENT. MODIFY LAYOUT AS <br />REQUIRED PER MANUFACTURER'S SPACE REQUIREMENTS. <br />2 COORDINATE FINAL LOCATIONS OF ALL DIVISION 23 EQUIPMENT IN FIELD WITH DIVISION 23. FIELD <br />LOCATIONS SHALL DICTATE. <br />3 COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF ALL DEVICES WITH ARCHITECTURAL <br />ELEVATIONS AND CASEWORK. <br />4 REFER TO KITCHEN VENDOR DRAWINGS FOR EXACT LOCATIONS AND REQUIREMENTS OF ALL <br />EQUIPMENT, ELECTRICAL DEVICES, AND ELECTRICAL CONNECTIONS <br />5 ALL ELECTRICAL WORK IN PROJECT SCOPE SHALL BE NEW. NO ELECTRICAL DEVICES, CONDUIT OR <br />WIRE SHALL BE RE USED, <br />6 CONTRACTOR SHALL INVESTIGATE ALL REQUIREMENTS OF EXISTING EQUIPMENT TO BE RELOCATED. <br />PROVIDE NEW ELECTRICAL CONNECTIONS AS NECESSARY, <br />7 REFER TO WIRE SIZE CHART ON DETAIL SHEET FOR WIRE SIZES, <br />POWER PLAN NOTES (CODED NOTES) <br />1 PROVIDE SURGE PROTECTION FOR BRANCH CIRCUIT(S) EXITING/ENTERING THE BUILDING. SURGE <br />PROTECTORS MUST BE UL LISTED. REFER TO SPECIFICATION FOR FUTHER INFORMATION. COORDINATE <br />EXACT LOCATION IN FIELD PRIOR TO ROUGH -IN. DESIGN SELECTION: 480V/3P - DYTEK: ZEUS <br />D50-277/4803Y, 1200 P -DYTEK DTK-120HW, 277V-1 P PHILLIPS 929000665202 OR APPROVED EQUAL. <br />2 PROVIDE LIGHTNING PROTECTION FOR ROOF MOUNTED MECHANICAL AND HVAC EQUIPMENT. <br />CEP <br />APPROXIMATE <br />LOCATION OF MSB <br />AND EQB <br />RS&H <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886' 1626000956 <br />5620 " LCC000210 * GB238 <br />�T LC <br />ENGINEERING <br />S O L U T I O N S® <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407.841.9050 <br />www.tic-engineers.com <br />COA 15 <br />0 Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />THINK. LISTEN. CREATE. <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Christopher V. O'Hara, P.E. <br />Florida License #66504 <br />%%%��,0 HER <br />�` 5� • O <br />O' No 66504 <br />C14 <br />13 STATE OF ' 4U� m <br />lo <br />i o ••'• p p <br />Digitall�,s� byZC0fi TvV® a •l Ir�ARA CC <br />DN: CN= hlE�hfi �� <br />OU=A0141 13D07, M <br />O=TLC ENGIN twNG f3A00 NS, C=US N <br />Date: 2021.02.04 13:24:59-05'00' LiJ <br />0 <br />0 <br />CU <br />IH <br />Z <br />W <br />J <br />0 <br />Q <br />0 <br />2 <br />Q <br />REVISIONS <br />NO. <br />DESCRIPTION <br />DATE <br />1 <br />REVISION 1 <br />06/15/2020 <br />2 <br />ADDENDUM NO.1 <br />07/17/2020 <br />3 <br />CCD #1 <br />01/07/2021 <br />5 <br />CCD #2 <br />02/03/2021 <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: CVO <br />DRAWN BY: MA <br />DESIGNED BY: MA <br />PROJECT NUMBER: <br />504- 0226- 000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />LEVEL 1 RENOVATION <br />PLAN - PHASE 1 - <br />POWER <br />SHEET ID: <br />E101 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />Copyright 0 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />N <br />3 <br />4 <br />5 <br />