F, <br />3 <br />4 <br />5 <br />10 HVAC KEY NOTES: I <br />F <br />C <br />B <br />A <br />I <br />AREA OF WORK <br />PER OWNER REQUEST, REMOVE SCOPE <br />OF WORK IN THE BAKERY AREA FROM <br />PHASE 1: REMOVAL OF EXISTING HOODS, <br />CONSTRUCTION OF WALL AND DOOR, <br />CEILING, LIGHTS, POWER, EF1-1, AND <br />ASSOCIATED DUCTWORK TO ENCLOSE <br />POT/DISHWASH AREA. THIS PORTION OF <br />WORK WILL BE MOVED TO LATER PHASE <br />(PHASE 2). REVISED PHASING PLAN <br />(A/MEP/FP) TO BE ISSUED UPON OWNER <br />j NOTICE TO PROCEED TO START OF <br />I PHASE 2 CONSTRUCTION. <br />Ij <br />I <br />I� <br />l <br />I� <br />j <br />OPEN AIR BREEZEWAY <br />IPMENT WILL <br />AIN IN THIS' <br />N. FOR PREP <br />3E ONLY' <br />P,'gil 'jai <br />(E)AHU-4 REBALANCE <br />SCHEDULE <br />SUPPLY <br />RETURN <br />OUTSIDE AIR <br />OLD <br />1,737 <br />1,160 <br />577 <br />NEW <br />1,400 <br />750 <br />650 <br />NOTES: <br />1. ADJUST VFD AS NECESSARY TO COMPLETE AIR BALANCE. <br />2. T&B CONTRACTOR SHALL PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />3. PROVIDE FULL PRE -DEMO AND FINAL REPORT INCLUDING SUPPLY <br />FAN DATA. <br />(E)AHU-3A REBALANCE <br />SCHEDULE <br />SUPPLY <br />RETURN <br />OUTSIDE AIR <br />OLD <br />1 2,989 <br />1,726 <br />1,263 <br />NEW <br />2.625 <br />1,400 <br />1,175 <br />NOTES: <br />1. ADJUST VFD AS NECESSARY TO COMPLETE AIR BALANCE. <br />2. T&B CONTRACTOR SHALL PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />3. PROVIDE FULL PRE -DEMO AND FINAL REPORT INCLUDING SUPPLY <br />FAN DATA. <br />0 REBALANCE EXISTING AIR DISTRIBUTION DEVICE (TYP.) <br />Q PROVIDE NEW FIRE RATED DAMPER AT FIRE RATED WALL, FIELD VERIFY <br />EXISTING DUCT ROUTING, SIZE, AND LOCATION PRIOR TO BID. <br />O3 COORDINATE NEW DUCTWORK WITH EXISTING CONDUITS, PIPING, LIGHTS <br />EXISTING DUCTWORK ETC. <br />® FABRICATED DUCTWORK MADE FROM STAINLESS STEEL CONFORMING TO <br />ASTM A430, TYPE 304 WITH 2B FINISH, ALL WELDED CONSTRUCTION. PROVIDE <br />VOLUME DAMPER ON EACH DROP. SEE DISHWASHER VENDOR CUTSHEETS <br />FOR ADDITIONAL INFORMATION. SLOPE DUCT AT A MINIMUM OF 1/8 TOWARDS <br />DISHWASHER UNIT. <br />O REBALANCE EXISTING EXHAUST FAN. <br />© BLANK OFF DIFFUSER. <br />O7 EXISTING FIRE DAMPER TO REMAIN, CONTRACTOR TO VERIFY THAT EXISTING <br />FIRE DAMPER IS IN GOOD WORKING CONDITION PRIOR TO NEW DUCTWORK <br />CONNECTION. <br />® CONNECT NEW 12"x12" DUCTWORK TO EXISTING FIRE DAMPER PROVIDE <br />TRANSITION AND ALL THE NECESSARY ACCESORIES TO MAKE PROPER <br />INSTALLATION. PROVIDE DUCTMOUNTED ACCESS DOOR FOR FIRE DAMPER. <br />(E)AHU-3 REBALANCE <br />SCHEDULE <br />SUPPLY <br />RETURN <br />OUTSIDE AIR <br />OLD <br />11,385 <br />0 <br />11,385 <br />NEW <br />7,625 <br />0 <br />7,625 <br />NOTES: <br />1. ADJUST VFD AS NECESSARY TO COMPLETE AIR BALANCE. <br />2. T&B CONTRACTOR SHALL PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />3. PROVIDE FULL PRE -DEMO AND FINAL REPORT INCLUDING SUPPLY <br />FAN DATA. <br />EFREBALANCE <br />SCHEDULE <br />MARK <br />OLD —7NEW <br />(E)EF-41 <br />2,030 <br />1,725 <br />NOTES: <br />1. T&B CONTRACTOR SHALL PROVIDE ALL BELTS AND SHEAVES AS <br />NECESSARY TO COMPLETE AIR BALANCE. <br />2. PROVIDE FULL PRE -DEMO AND FINAL REPORT <br />VENTILATION <br />TABLE- PHASE 1 <br />ROOM <br />SUPPLY <br />RETURN <br />EXHAUST <br />AREA <br />CEILING <br />HEIGHT <br />REQUIRED <br />OA AC/HR <br />DESIGN <br />OA AC/HR <br />REQUIRED <br />AC/HR <br />DESIGN <br />AC/HR <br />DISHWASH <br />800 <br />0 <br />1200 <br />730 <br />8.0 <br />0.0 <br />0.0 <br />10.0 <br />11.6 <br />ELEC <br />300 <br />300 <br />0 <br />60 <br />15.0 <br />N/A <br />0.0 <br />0.0 <br />26.7 <br />TEMP. POT/DISH <br />425 <br />0 <br />500 <br />156 <br />8.5 <br />0.0 <br />0.0 <br />10.0 <br />22.6 <br />NOTE: <br />1.) THE REQUIRED OUTDOOR AIR AND AIR CHANGES ARE PER HEALTH CARE GUIDELINES AND ASHRAE 170 <br />2.) AIR CHANGES PER HOUR = CFM*60/AREA*HEIGHT <br />RS&H <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />8' <br />TL C <br />ENGINEERING <br />SOLUTIONS <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407.841.9050 <br />www.tic-engineers.com <br />COA 15 <br />0 Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />THINK. LISTEN. CREATE. <br />PROJECT TITLE: <br />KITCHEN RENOVATION <br />ADVENTHEALTH ZEPHYRHILLS <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />LEE ,U0y <br />i <br />- <br />No 71576 <br />ST 4U: <br />REVISIONS <br />NO. <br />DESCRIPTION <br />DATE <br />1 <br />REVISION No.1 <br />06/15/2020 <br />3 <br />CCD #1 <br />01 /07/2021 <br />5 <br />CCD #2 <br />02/03/2021 <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: AU <br />DRAWN BY: LLP <br />DESIGNED BY: LLP <br />PROJECT NUMBER: <br />504- 0226- 000 <br />0 2019 RS&H, INC. <br />SHEET TITLE: <br />LEVEL 1 RENOVATION <br />PLAN - PHASE 1- <br />DUCTWORK <br />SHEET ID: <br />M101 <br />r- <br />A <br />N <br />co <br />0 <br />M <br />N <br />UJ <br />C <br />O <br />t� <br />Z <br />W <br />J <br />C.i <br />a <br />c� <br />LEVEL 1 RENOVATION - PHASE 1 - DUCTWORK <br />SCALE: 1/8" =1'-0" <br />Copyright C 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the 2 <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />3 <br />4 <br />8 0 8 16 <br />SCALE: 1/8" = V-0" <br />5 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />