Laserfiche WebLink
ANCHOR ABOVE <br />CEILING TO WALL <br />STUD: / 5OLPS <br />ONE EACH ROOM LMI <br />ELI-S-E O BATTERY <br />BACKUP SYSTEM PO <br />WATT FOR 90 MINUTES <br />L I E1.IERGENC <br />LINE POWER FROM <br />..1,.v, <br />ROOM LIGHT CIRCUIT UNL's` <br />WALL, <br />SWITCH <br />ELEVATION <br />ELECTRICAL ABBREVIATIONS <br />A <br />AMPERE <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />AL <br />ALUMINUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />AWG <br />AMERICAN WIRE GAUGE <br />BC <br />BELOW CEILING <br />C <br />CONDUIT <br />CB, CKT BKR <br />CIRCUIT BREAKER <br />CLG <br />CEILING <br />CU <br />COPPER OR CONDENSING UNIT <br />DISC <br />DISCONNECT <br />EC <br />ELECTRICAL CONTRACTOR <br />ECB <br />ENCLOSED CIRCUIT BREAKER <br />ELEV <br />ELEVATOR <br />EMT <br />ELECTRICAL METALLIC TUBING <br />ENT <br />ELECTRICAL NONMETALLIC TUBING <br />FOR <br />ENGINEER OF RECORD <br />ERRCS <br />EMERGENCY RESPONDER RADIO COVERAGE SYSTEM <br />ES <br />ENERGY SAVING <br />EVC <br />ELECTRIC VEHICLE CHARGER <br />FAAP <br />FIRE ALARM ANNUNCIATOR PANEL <br />FACP <br />FIRE ALARM CONTROL PANEL <br />FPC <br />FIRE PUMP CONTROLLER <br />FSD <br />FIRE SMOKE DAMPER <br />G,GND <br />GROUND <br />GACP <br />GENERATOR ANNUNCIATOR AND CONTROL PANEL <br />GD <br />GENERATOR DISCONNECT <br />GEN <br />GENERATOR <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />HOA <br />HAND -OFF -AUTOMATIC <br />HP <br />HORSEPOWER <br />HT <br />HEIGHT <br />IG <br />ISOLATED GROUND <br />JB, J-BOX <br />JUNCTION BOX <br />JPC <br />JOCKEY PUMP CONTROLLER <br />KAIC <br />THOUSAND AMPERE INTERRUPTING CAPACITY <br />kcmil <br />THOUSAND CIRCULAR MILS <br />KVA <br />KILOVOLT -AMPERE <br />LC <br />LIGHTING CONTRACTOR <br />MC <br />MECHANICAL CONTRACTOR <br />MCB <br />MAIN CIRCUIT BREAKER <br />MLO <br />MAIN LUGS ONLY <br />N/L <br />NIGHT LIGHT <br />NAC <br />NOTIFICATION APPLIANCE CABINET <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NIC <br />NOT IN CONTRACT <br />OC <br />ON CENTER <br />PNL <br />PANEL <br />PVC <br />POLY -VINYL -CHLORIDE (SCHEDULE 40, UON) <br />SE <br />SERVICE ENTRANCE <br />TBB <br />TELECOMMUNICATIONS BACKBONE BONDING <br />TGB <br />TELECOMMUNICATIONS GROUND BAR <br />TMGB <br />TELECOMMUNICATIONS MAIN GROUND BAR <br />TR <br />TAMPER RESISTANT <br />TTB <br />TELECOMMUNICATIONS TERMINAL BOARD <br />TYP <br />TYPICAL <br />LID <br />UTILITY DISCONNECT <br />UON <br />UNLESS OTHERWISE NOTED <br />V <br />VOLT <br />VA <br />VOLT-AMPERE <br />W <br />IWATT <br />WP <br />IWEATHERPROOF <br />LINE OF CEILING <br />STANDARD FLUORESCENT <br />3-LAMP FIXTURE 96 WATT` <br />42' GRAB BAR. <br />TREATMENT ROOM LIGHTING EMG. BACKUP DETAIL <br />SCALE:NTS <br />GROUND BUS <br />NEUTRALBUS <br />BRANCH CIRCUIT VOLTAGE DROP TABLE <br />NOTES: <br />A. BRANCH CIRCUIT UNGROUNDED AND NEUTRAL CONDUCTORS ADJUSTED FOR VOLTAGE DROP OF 3%. <br />B. EQUIPMENT GROUNDING CONDUCTOR SIZE INCREASE IN PROPORTION TO UNGROUNDED <br />CONDUCTORS PER NEC 250.122(B). <br />C. VOLTAGE DROP CALCULATIONS BASED ON 100% CIRCUIT LOAD, 100% POWER FACTOR, AND 6 OR LESS <br />CURRENT CARRYING CONDUCTORS PER RACEWAY. <br />D. DISTANCE INDICATES CONDUCTOR LENGTH FROM OVERCURRRENT DEVICE TO LAST DEVICE / OUTLET / <br />EQUIPMENT. <br />E. THE LARGER OF THE CONDUCTOR SIZES INDICATED IN THE PANEL SCHEDULES AND THE VOLTAGE <br />DROP TABLE ABOVE, SHALL BE USED. <br />F. WHERE THE WIRE SIZE IS LARGER THAN THE MAXIMUM WIRE SIZE TERMINAL OF THE EQUIPMENT, <br />PROVIDE A JUNCTION BOX AND SPLICE DOWN TO THE LARGEST WIRE SIZE POSSIBLE. THE BOX SHALL <br />G. BE LOCATED AS CLOSE TO THE TERMINATION AS POSSIBLE, BUT NO FARTHER THAN 15 FEET. <br />WHERE BRANCH CIRCUIT EXCEEDS DISTANCES NOTED ABOVE AND SIZES ARE NOT OTHERWISE NOTED <br />ON PLANS, NOTIFY ENGINEER. <br />OVER- <br />BRANCH CIRCUIT <br />MAXIMUM LENGTH <br />CURRENT <br />PROTECTION <br />CONDUCTOR <br />(PH&N / G) <br />RACEWAY <br />120V, 10 <br />208V, 10 <br />208V, 30 <br />277V, 10 <br />480V, 10 <br />480V, 30 <br />15A <br />#12 / #12 <br />1/2" <br />60' <br />105' <br />121' <br />140' <br />242' <br />280' <br />#10/#10 <br />1/2" <br />96' <br />167' <br />193' <br />222' <br />386' <br />445' <br />#8 / #8 <br />3/4" <br />153' <br />266' <br />307' <br />354' <br />614' <br />709' <br />#6/#6 <br />1" <br />244' <br />423' <br />488' <br />563' <br />976' <br />1127' <br />20A <br />#12 / #12 <br />1/2" <br />45' <br />78' <br />91, <br />105, <br />182' <br />210' <br />#10/#10 <br />1/2" <br />72' <br />125' <br />144' <br />167' <br />289' <br />334' <br />#8 / #8 <br />3/4" <br />115' <br />199, <br />230' <br />265' <br />460' <br />532' <br />#6 / #6 <br />1" <br />183' <br />317' <br />366' <br />422' <br />732' <br />845' <br />30A <br />#10/#10 <br />1/2" <br />48' <br />83' <br />96' <br />111' <br />193' <br />222' <br />#8 / #8 <br />3/4" <br />76' <br />133' <br />153' <br />177' <br />307' <br />354' <br />#6 / #6 <br />1" <br />122' <br />21 l' <br />244' <br />281' <br />488' <br />563' <br />#4/#4 <br />1-1/4" <br />194' <br />336' <br />388' <br />448' <br />776' <br />896' <br />40A <br />#8 / #10 <br />3/4" <br />57' <br />99, <br />115, <br />132' <br />230' <br />266' <br />#6 / #8 <br />1" <br />91, <br />158' <br />183' <br />21 l' <br />366' <br />422' <br />#4 /#4 <br />1-1/4" <br />145' <br />252' <br />291' <br />336' <br />582' <br />672' <br />#3/#4 <br />1-1/4" <br />183' <br />318' <br />367' <br />423' <br />734' <br />847' <br />50A <br />#6/#10 <br />1" <br />73' <br />126' <br />146' <br />169' <br />292' <br />338' <br />#4/#6 <br />1-1/4" <br />116' <br />201' <br />233' <br />268' <br />465' <br />538' <br />#3/#6 <br />1-1/4" <br />146' <br />254' <br />293' <br />338' <br />587' <br />678' <br />#2/#4 <br />1-1/4" <br />185' <br />320' <br />370' <br />427' <br />740 <br />855' <br />60A <br />#6 / #10 <br />1" <br />61' <br />105' <br />122' <br />140' <br />244' <br />281' <br />#4/#6 <br />1-1/4" <br />97' <br />168' <br />194' <br />224' <br />388' <br />448' <br />#3/#6 <br />1-1/4" <br />122' <br />212' <br />244' <br />282' <br />489' <br />565' <br />#2/#4 <br />1-1/4" <br />154' <br />267' <br />308' <br />356' <br />617' <br />712' <br />70A <br />#4 / #8 <br />1-1/4" <br />83' <br />144' <br />166' <br />192' <br />332' <br />384' <br />#3 / #6 <br />1-1/4" <br />104' <br />181' <br />209' <br />242' <br />419' <br />484' <br />#2 / #4 <br />1-1/4" <br />132' <br />229' <br />264' <br />305' <br />529' <br />610' <br />#1 /#4 <br />1-1/2" <br />166' <br />298' <br />333' <br />385' <br />667' <br />770' <br />80A <br />#3 / #8 <br />1-1/4" <br />91, <br />159, <br />183' <br />21 l' <br />367' <br />423' <br />#2 / #6 <br />1-1/4" <br />115, <br />200' <br />231' <br />267' <br />462' <br />534' <br />#1 / #4 <br />1-1/2" <br />145' <br />253' <br />292' <br />336' <br />583' <br />674' <br />#1 /0 / #4 <br />1-1/2" <br />184' <br />319' <br />368' <br />425' <br />736' <br />850' <br />90A <br />#2 / #8 <br />1-1/4" <br />102' <br />178' <br />205' <br />237' <br />411' <br />475' <br />#1 / #6 <br />1-1/2" <br />129' <br />224' <br />259' <br />299' <br />519, <br />599' <br />#1/0 / #4 <br />1-1/2" <br />163' <br />283' <br />327' <br />377' <br />654' <br />756' <br />#2/0 / #4 <br />2" <br />206' <br />357' <br />413' <br />476' <br />825' <br />953' <br />100A <br />#2 / #8 <br />1-1/4" <br />92' <br />160' <br />185' <br />213' <br />370' <br />427' <br />#1/#6 <br />1-1/2" <br />116' <br />202' <br />233' <br />269' <br />467' <br />539' <br />#1 /0 / #4 <br />1-1/2" <br />147' <br />255' <br />294' <br />340' <br />589' <br />680' <br />#2/0 / #4 <br />2" <br />185' <br />321' <br />371' <br />428' <br />742' <br />857' <br />SERVICE <br />ENTRANCE <br />EQUIP <br />t_ _J <br />GROUNDING ELECTRODE CONDUCTOR <br />AS INDICATED ON POWER RISER DIAGRAM <br />(SIZE PER 2005 NEC TABLE 250-66, MIN) <br />3/4" 0 X 10'-0" CU. <br />GROUND ROD <br />DRIVEN TO t3" <br />BELOW FINISH <br />GRADE <br />#6 CU. MIN, IF NO <br />METALLIC WATER <br />MAIN, CONTINUE <br />FULL SIZE GEC <br />d �¢ <br />GROUNDING DETAIL <br />SCALE: NTS <br />#6 CU, MIN <br />EXOTHERMIC WELD <br />TO BLDG STEEL <br />INTERSYSTEM (WHERE AVAILABLE) <br />BONDING BAR PER <br />NEC 250-94 <br />GROUND CLAMP ON <br />METALLIC WATER MAIN <br />#4 CU, MIN <br />CONC FOUNDATION <br />OR FOOTING INDIRECT <br />CONTACT WITH EARTH <br />20' OF 1/2" GAL STEEL ROD <br />2" MIN CONCRETE COVER <br />PROVIDE SHORT PVC SLEEVE OR OTHER <br />DESIGNATION ACCEPTABLE TO THE LOCAL <br />INSPECTOR TO IDENTIFY ROD AS PROPERLY <br />INSTALLED, BONDED <br />LIGHTING SYSTEMS COMMISSIONING REQUIREMENTS <br />LIGHTING CONTROL SYSTEM SHALL UNDERGO FUNCTIONAL TESTING AS DESCRIBED BELOW. TESTING SHALL BE BY THE CONTRACTOR UNDER THE <br />SUPERVISION OF A CERTIFIED REPRESENTATIVE OF THE LIGHTING CONTROL SYSTEMS MANUFACTURER(S). <br />PRIOR TO PASSING FINAL INSPECTION, THE LIGHTING CONTROL SYSTEMS SHALL HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND <br />SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION <br />DOCUMENTS AND MANUFACTURER'S INSTRUCTIONS. THE CONTRACTOR SHALL SUBMIT A LETTER CERTIFYING THE SUCCESSFUL COMPLETION OF <br />FUNCTIONAL TESTING TO THE ENGINEER AT LEAST 2 DAYS PRIOR TO FINAL INSPECTION. THIS CERTIFICATION LETTER MUST BE AVAILABLE TO THE <br />INSPECTOR AT THE TIME OF FINAL INSPECTION. <br />OCCUPANT SENSOR CONTROLS <br />1. CERTIFY THAT THE OCCUPANT SENSORS HAVE BEEN LOCATED AND AIMED FOR PROPER COVERAGE OF THE INTENDED AREA IN ACCORDANCE <br />WITH MANUFACTURER RECOMMENDATIONS. <br />2. FOR PROJECTS WITH SEVEN OR FEWER OCCUPANT SENSORS, EACH SENSOR SHALL BE TESTED. <br />3. FOR PROJECTS WITH MORE THAN SEVEN OCCUPANT SENSORS, TESTING SHALL BE DONE FOR EACH UNIQUE COMBINATION OF SENSOR TYPE AND <br />SPACE GEOMETRY. WHERE MULTIPLES OF EACH UNIQUE COMBINATION OF SENSOR TYPE AND SPACE GEOMETRY ARE PROVIDED, NOT LESS THAN <br />10 PERCENT, BUT IN NO CASE LESS THAN ONE, OF EACH COMBINATION SHALL BE TESTED UNLESS THE CODE OFFICIAL REQUIRES A HIGHER <br />PERCENTAGE TO BE TESTED. WHERE 30 PERCENT OR MORE OF THE TESTED CONTROLS FAIL, ALL REMAINING IDENTICAL COMBINATIONS SHALL BE <br />TESTED. <br />FOR OCCUPANT SENSOR CONTROLS TO BE TESTED, VERIFY THE FOLLOWING: <br />1. WHERE OCCUPANT SENSOR CONTROLS INCLUDE STATUS INDICATORS, VERIFY CORRECT OPERATION. <br />2. THE CONTROLLED LIGHTS TURNOFF OR DOWN TO THE PERMITTED LEVEL WITHIN THE REQUIRED TIME. <br />3. FOR AUTO —ON OCCUPANT SENSOR CONTROLS, THE LIGHTS TURN ON TO THE PERMITTED LEVEL WHEN AN OCCUPANT ENTERS THE SPACE. <br />4. FOR MANUAL -ON OCCUPANT SENSOR CONTROLS, THE LIGHTS TURN ON ONLY WHEN MANUALLY ACTIVATED. <br />5. THE LIGHTS ARE NOT INCORRECTLY TURNED ON BY MOVEMENT IN ADJACENT AREAS OR BY HVAC OPERATION. <br />TIME —SWITCH CONTROLS <br />1. CONFIRM THAT THE TIME —SWITCH CONTROL IS PROGRAMMED WITH ACCURATE WEEKDAY, WEEKEND AND HOLIDAY SCHEDULES. <br />2. PROVIDE DOCUMENTATION TO THE OWNER OF TIME —SWITCH CONTROLS PROGRAMMING INCLUDING WEEKDAY, WEEKEND, HOLIDAY SCHEDULES, <br />AND SET—UP AND PREFERENCE PROGRAM SETTINGS ARE AS DIRECTED BY THE OWNER. <br />3. VERIFY THE CORRECT TIME AND DATE IN THE TIME SWITCH. <br />4. VERIFY THAT ANY BATTERY BACK—UP IS INSTALLED AND ENERGIZED. <br />5. VERIFY THAT THE OVERRIDE TIME LIMIT IS SET TO NOT MORE THAN 2 HOURS (OR KEY SWITCH OVERRIDE PROVISION IN RETAIL APPLICATIONS). <br />6. SIMULATE OCCUPIED CONDITION. VERIFY AND DOCUMENT THE FOLLOWING: <br />a. ALL LIGHTS CAN BE TURNED ON AND OFF BY THEIR RESPECTIVE AREA CONTROL SWITCH. <br />b. THE SWITCH ONLY OPERATES LIGHTING IN THE ENCLOSED SPACE IN WHICH THE SWITCH IS LOCATED. <br />7. SIMULATE NOCCUPIED CONDITION. VERIFY AND DOCUMENT THE FOLLOWING: <br />a. NONEXEMPT LIGHTING TURNS OFF. <br />b. MANUAL OVERRIDE SWITCH ALLOWS ONLY THE LIGHTS IN THE ENCLOSED SPACE WHERE THE OVERRIDE SWITCH IS LOCATED TO TURN ON OR <br />REMAIN ON UNTIL THE NEXT SCHEDULED SHUTOFF OCCURS. <br />DAYLIGHT RESPONSIVE CONTROLS. <br />1. CONTROL DEVICES HAVE BEEN PROPERLY LOCATED, FIELD CALIBRATED AND SET FOR ACCURATE SETPOINTS AND THRESHOLD LIGHT LEVELS. <br />2. DAYLIGHT CONTROLLED LIGHTING LOADS ADJUST TO LIGHT LEVEL SET POINTS IN RESPONSE TO AVAILABLE DAYLIGHT. <br />3. THE LOCATIONS OF CALIBRATION ADJUSTMENT EQUIPMENT ARE READILY ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. <br />EXTERIOR LIGHTING CONTROLS <br />1. PHOTOCELUSENSORS HAVE BEEN PROPERLY LOCATED, FIELD CALIBRATED AND SET FOR ACCURATE SETPOINTS AND THRESHOLD LIGHT LEVELS. <br />2. TIME SWITCH CONTROL AS DESCRIBED ABOVE. <br />3. AFTER—HOURS LIGHTING LEVEL REDUCTION IS IMPLEMENTED IN ACCORDANCE WITH THE OWNER'S SCHEDULE DIRECTION (EITHER FROM MIDNIGHT <br />TO 6AM OR, FROM ONE HOUR AFTER TO ONE HOUR PRIOR TO BUSINESS HOURS.) <br />4. THE LOCATIONS OF CALIBRATION ADJUSTMENT EQUIPMENT ARE READILY ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. <br />AS —BUILT DOCUMENTATION <br />DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET THE DOCUMENTED PERFORMANCE CRITERIA OF FBC ENERGY CODE <br />SECTION C405 SHALL BE PROVIDED IN THE PROJECT AS —BUILT DOCUMENTATION. DELIVERY OF AS —BUILT DOCUMENTATION SHALL BE PROVIDED TO THE <br />BUILDING OWNER WITHIN 30 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. <br />GENERAL SYMBOLS <br />PLAN OR DETAIL NO. <br />SHEET NUMBER <br />OKEYED <br />NOTE TO PLAN <br />QREVISION <br />NUMBER <br />N <br />NORTH ARROW <br />FIRE ALARM HORN AND/OR ALIGN HORN ONLY DEVICE WITH TOP OF DOOR FRAME, NOT <br />STROBE LIGHT (WHITE FINISH, TYP) TO EXCEED 96" AFF. STROBE OR HORN/STROBE DEVICE 80" <br />AFF TO BOTTOM OF STROBE LENS <br />ALIGN WHEN MOUNTED 4 <br />ON SAME WALL <br />LIGHT SWITCH <br />OR DIMMER i WALL MOUNTED <br />TELEPHONE <br />FIRE ALARM <br />PULL STATION <br />0 <br />CEILING <br />RECEPTACLE <br />a (HORIZONTAL) <br />©© <br />x I <br />co <br />O m I <br />UNOBSTRUCTED <br />O <br />00 <br />U <br />O <br />COUNTER OR OTHER <br />r- U_ <br />_ O I <br />RECEPTACLE <br />v O <br />O m <br />U_ <br />OBSTRUCTION <br />0 a <br />LO a <br />O <br />o °x <br />0- <br />UX <br />O <br />O <br />Om <br />U_ <br />-°r° O <br />FLOOR <br />TELEPHONE OR DATA <br />JACK MOUNT AT SAME <br />HEIGHT AS ADJACENT <br />RECEPTACLE <br />MOUNTING HEIGHT DIAGRAM <br />SCALE: NTS <br />McVEIGH&MANGUM <br />ENGINEERING INC <br />Atlanta • Charlotte • Jacksonville Raleigh <br />www.MeVeigbMangatn.com <br />1955 Lake Park Drive SE, Suite 325 <br />Smyrna, Georgia 30080 <br />Ph: (678) 213-1616 <br />email: mail@McVeighMmgum.com <br />PEF005182 <br />Eng. of Record:LADD D. MARKS, P.E. License No.:58264 <br />R A N D A L L <br />P A U L S 0 N <br />a r G l I t e G t S <br />Roswell Mill <br />85-A Mill Street, Suite 290 <br />Roswell, Georgia 30075 <br />t 770.650.7558 f 770.650.7559 <br />e-mail architects@randallpaulsen.com <br />These plans and specifications are the property of flandall-Paulson Architects, <br />Incorporated. These documents may not he copied, reproduced, used or <br />implemented in any way, in part ar in whole, Othout the written consent of <br />Randall -Poulson Architects, Incorporated. All common law rights of copyright are <br />hereby specifically reserved. <br />TENANT <br />BUILD -OUT <br />at <br />ZEPHYRHILLS <br />for <br />U.S. HIGHWAY 301 & PRETTY <br />POND ROAD, <br />ZEPHYRHILLS, FLORIDA 33541 <br />Print Record <br />Revisions <br />Date Project No. <br />14 JUNE 2021 2021217.00 <br />Sheet Title <br />NOTES & DETAILS <br />Sheet No. <br />E�002 <br />Released for Construction <br />❑Not Released for Construction <br />