My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7898 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7898 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:54:16 PM
Creation date
2/19/2025 1:10:48 PM
Metadata
Fields
Template:
Building Plans
Street #
7898
Location
Gall Blvd
Contractor
Schaefer General Contracting
Building Plans - Permit #
313
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MECHANICAL GENERAL NOTES: <br />• IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE <br />SCALED. <br />• INTENT OF THESE NOTES AND MECHANICAL NOTES ON DRAWINGS IS TO CLARIFY <br />THE SCOPE OF WORK AND ALERT CONTRACTOR OF EXISTING CONDITIONS. <br />CONTRACTOR TO VISIT SITE AND VERIFY ALL CLEARANCES BEFORE FABRICATION <br />OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT <br />SIZES TO MEET FIELD CONDITIONS AND COORDINATE WITH ELECTRICAL, PLUMBING <br />AND FIRE PROTECTION SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK. <br />• BIDDERS SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL <br />CONDITIONS INVOLVING THE WORK. <br />• SHOULD ANY CONFLICTS ARISE, THE CONTRACTOR SHALL NOTIFY THE ENGINEER <br />OF THE CONFLICT BEFORE ANY CHANGES ARE MADE. THE CONTRACTOR SHALL <br />OBTAIN WRITTEN APPROVAL BEFORE PROCEEDING WITH ANY CHANGES. <br />• THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES INSTALLATION <br />SCHEDULES. FIXED WORK SUCH AS DUCTWORK AND PLUMBING SHALL BE INSTALLED <br />PRIOR TO ANY TRADE WORK THAT CAN BE EASILY RELOCATED OR OFFSET SUCH <br />AS ELECTRICAL CONDUITS AND SMALL WATER LINES ETC. <br />• ALL AIR CONDITIONING WORK SHALL NOT INTERFERE WITH CLEARANCES <br />REQUIRED FOR GENERAL AND MECHANICAL CONSTRUCTION. SHOULD AIR <br />CONDITIONING WORK BE INSTALLED WHICH INTERFERES WITH THE WORK <br />OF OTHER CONTRACTORS. SUCH WORK SHALL BE CHANGED AT NO <br />ADDITIONAL COST TO THE OWNER. <br />• ALL WORK COVERED IN THIS SECTION SHALL BE CONSTRUCTED IN ACCORDANCE <br />WITH THE LATEST PUBLISHED STANDARDS OF ASHRAE, AND NFPA. <br />• ALL MECHANICAL WORK SHALL MEET ALL THE REQUIREMENTS OF THE "FLORIDA <br />BUILDING CODE 2017, 6TH EDITION". <br />• IN THE EVENT THAT THERE IS A CONFLICT BETWEEN THE CONTRACT DOCUMENTS <br />AND THE CODE, THE CODE SHALL TAKE PRECEDENCE. THE MECHANICAL <br />CONTRACTOR SHALL STUDY THE CONTRACT DOCUMENTS AND SUBMIT A BID <br />BASED ON WORK WHICH COMPLIES WITH ALL CODE REQUIREMENTS. ANY <br />CONFLICTS BETWEEN THE CONTRACTOR DOCUMENTS AND THE CODE SHALL BE <br />BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BID. THE COST OF <br />ANY WORK WHICH ARISES OUT OF ANY CHANGES DUE TO CODE REQUIREMENTS <br />SHALL BE PAID BY THE MECHANICAL CONTRACTOR. <br />• THE MECHANICAL CONTRACTOR SHALL CHECK ALL EQUIPMENT FOR CORRECT <br />VOLTAGE RATING BEFORE INSTALLATION. <br />• IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR FOR THE <br />ADVANCE ORDERING OF LONG LEAD ITEMS SO AS NOT TO DELAY OTHER TRADES <br />RESULTING IN ANY DOWN OR LAG TIME. <br />• THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS <br />WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO COMPLETE THE <br />INSTALLATION WHETHER OR NOT SPECIFIED AS SHOWN ON THE PLANS. <br />• MECHANICAL CONTRACTOR SHALL ARRANGE TO PAY FOR ALL NECESSARY PERMITS, <br />LICENSES AND INSPECTIONS AS REQUIRED BY THE CITY. <br />• TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND <br />SPECIFICATIONS COMPLY WITH THE MINIMUM BUILDING CODES. <br />• DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. <br />• ALL CONCEALED SUPPLY AND RETURN DUCTWORK SHALL BE FABRICATED OF 1-1/2" <br />THICK R-6 (MIN.) DUCTBOARD WITH GALVANIZED SHEET METAL TURNING VANES AND <br />MANUAL VOLUME DAMPERS. ALL EXPOSED DUCT SHALL BE DOUBLE WALL SPIRAL <br />SEAM DUCT WITH A 'PAINT -GRIP' PRIMER FINISH. ALL TOILET EXHAUST DUCTWORK <br />SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL MATERIAL. <br />• MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 8'-0". <br />• ALL EXPOSED DUCTWORK SHALL DOUBLE WALL SPIRAL SEAM DUCT WITH A "PAINT -GRIP" <br />PRIMER FINISH. FINAL COLOR SELECTION BY ARCHITECT. <br />• VOLUME DAMPERS NTH LOCKING QUADRANTS SHALL BE INSTALLED IN ALL DUCT <br />BRANCHES. <br />• ALL INSULATION SHALL HAVE A MINIMUM FLAME SPREAD/SMOKE DEVELOPED <br />RATING OF 25/50. <br />• FLEXIBLE DUCTWORK SHALL BE LOW PRESSURE FACTORY FABRICATED CONSISTING <br />OF A ZINC -COATED SPRING STEEL HELIX, NON -PERFORATED INNER LINER AND <br />1" THICK FIBERGLASS INSULATION WITH METALIZED VAPOR BARRIER. <br />• COORDINATE AIR DEVICE LOCATIONS WITH LIGHTING FIXTURES. <br />• ALL SUPPLY AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS OTHERWISE NOTED. <br />• INSULATE BACK PANS OF ALL DIFFUSERS. <br />• LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE COORDINATED <br />WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF <br />THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER OR <br />HIS REPRESENTATIVE IN THE FIELD. <br />• AT THE CONCLUSION OF THE INSTALLATION THE CONTRACTOR SHALL SUBMIT TO <br />THE ENGINEER FOR APPROVAL A COMPLETE CERTIFIED TEST AND BALANCE REPORT <br />FROM AN AGENCY HAVING A MINIMUM OF THREE YEARS EXPERIENCE. REPORT <br />SHALL ITEMIZE THE PERFORMANCE OF EACH AIR DEVICE AND A/C UNIT WITH <br />REGARD TO CFM, STATIC PRESSURE AND TEMPERATURE. <br />SUPPLY DUCT RING SEAL COLLAR <br />W/ DAMPER. CROWN <br />,--PRODUCTS NO. 654 <br />>< !xt <br />ROUND METAL DUCT <br />(EXTERNAL INSULATION) <br />CEILING -� CEILING DIFFUSER <br />INSULATED ROUND FLEXIBLE <br />DUCT (MAX. 8'-0" LONG) <br />ATTACH INNER LINER WITH PANDUIT <br />STRAP TO DIFFUSER COLLAR. SEAL <br />OUTSIDE INSULATION WRAP WITH DUCT <br />TAPE <br />FULLY INSULATE <br />TOP OF DIFFUSER <br />`-SEAL INSULATION TO <br />'T'. BAR GRID WITH <br />DUCT TAPE. <br />CEILING DIFFUSER RUNOUT DETAIL <br />NOT TO SCALE <br />FAN SCHEDULE <br />MARK <br />- <br />EF-1 <br />SERVICE <br />- <br />EXHAUST <br />AREA SERVED <br />- <br />RESTROOM <br />AIR QUANTITY <br />CFM <br />40 <br />EXT. STATIC PRESS. <br />IN. H2O <br />0.50 <br />FAN TYPE <br />- <br />CEILING VENT <br />DRIVE <br />- <br />DIRECT <br />SONES <br />- <br />2.7 <br />MOTOR <br />M.P./WATTS <br />80.2W <br />MOTOR SPEED <br />RPM <br />950 <br />ELECTRICAL <br />V/O/HZ <br />120/1/60 <br />CONTROL <br />_ <br />INTERLOCK <br />W UGHTS <br />MANUFACTURER <br />- <br />GREENHECK <br />MODEL <br />- <br />SP-B110 <br />NOTES <br />® <br />0 <br />Q1 PROVIDE AND INSTALL WITH DISCONNECT, <br />BACKDRAFT DAMPER AND WHITE EXHAUST <br />GRILLE. <br />Q PROVIDE WALL CAP AND INSTALL SOLID STATE <br />SPEED CONTROL AT FAN FOR BALANCING. <br />* APPROVED EQUALS SHALL BE COOK AND <br />PENN. <br />AIR DEVICE SCHEDULE <br />MARK <br />TYPE <br />MATERIAL <br />FINISH <br />MANUFACTURER <br />AND MODEL <br />REMARKS <br />AD-1 <br />CEILING <br />ALUMINUM <br />WHITE <br />11TUS <br />1 <br />SUPPLY <br />BAKED ENAMEL <br />OMNI <br />AD-2 <br />CEILING <br />ALUMINUM <br />WHITE <br />TITUS <br />2 <br />RET. EXH. <br />BAKED ENAMEL <br />I 350FL <br />AD-3 <br />CEILING <br />SUPPLY <br />ALUMINUM <br />WHITE <br />BAKED ENAMEL <br />TITUS <br />OMNI <br />3 <br />1O PROVIDE 24x24 MODULE WITH ROUND NECK TRANSITION. SEE PLANS <br />FOR NECK SIZES. <br />Q PROVIDE 24x24 MODULE, WITH 22x22 NECK. <br />PROVIDE 12x12 MODULE WITH 6.0 NECK. <br />* APPROVED EQUALS SHALL BE METALAIRE, PRICE AND NAILOR. <br />WALL CAP <br />MECHANICAL LEGEND <br />SYMBOL DESCRIPTION <br />NEW DUCTWORK, PIPING, OR EQUIPMENT <br />5- _ _ _ _ _ - _ EXISTING DUCTWORK, PIPING, OR EQUIPMENT <br />— "- TO REMAIN <br />FLEXIBLE DUCT <br />SUPPLY OR OUTSIDE AIR DUCT SECTION <br />RETURN DUCT SECTION <br />® EXHAUST DUCT SECTION <br />DUCTWORK TRANSITION <br />MANUAL AIR VOLUME CONTROL DAMPER <br />® SUPPLY AIR DEVICE. CLEAR TRIANGLE SIDES <br />INDICATE AIR FLOW PATTERN <br />RETURN AIR DEVICE <br />z EXHAUST AIR DEVICE <br />U <br />10"0 AD-1 <br />® i 320 CFM <br />U F7TYP OF 2 <br />Li <br />IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII - ---- <br />OFFICE - <br />SMOOTHIE 6"0 <br />KITCHEN 8 � AD-1 PREP <br />260 CFM <br />8"0 AD-1 NP OF 2 FOOD ; ; CASHIER <br />PREP <br />150 CFM (2)AD-2 <br />r — <br />TYP OF 2 <br />1325 CFM <br />-� �-- 1 <br />- --- - ----- ---- - --- <br />RTU-EX <br />12x12 <br />® 6x12 � 12x12 14x12 � O d � Q <br />DINING O <br />6"0 AD-1 L — _ _ J <br />I� <br />60 CFM ISTORAGE I� <br />® RESTROOM <br />��/ EF-1 40 CFM <br />Im <br />FLOOR PLAN — MECHANICAL <br />SCALE: 1 /4"=1'-0" /4187-M1.0 IQ p <br />MECHANICAL NOTES: <br />O1 EXISTING 4 TON ROOFTOP UNIT TO BE REUSED. <br />PROVIDE NEW AIR DISTRIBUTION SYSTEM. BALANCE TO: <br />1560 CFM SUPPLY AIR <br />235 CFM OUTSIDE AIR <br />5596 Rio Vista Drive <br />ID Clearwater, Florida 33760 <br />ENG ER17VG _ (727)531-2989 ' Reg. No. ED6890 <br />pyragnid®p mmidengineering.org <br />CONSULTINC INCINERRS <br />c� <br />°D E <br />M <br />O <br />in <br />M ,N <br /><m <br />S <br />Z E <br />ca <br />Sf <br />o 2 <br />04 <br />ir <br />Ci <br />PIP- <br />no <br />c <br />x <br />w <br />w <br />fi <br />uZi <br />CO <br />a <br />wal <br />1-0 <br />� <br />r <br />r <br />r <br />r � <br />1 t <br />N 46 = <br />� sT YE OF 4f <br />WIIOV� Q7! o \ <br />PE 45 4IS�itll�`e� <br />No. 1910 <br />TITLE: MECHANICAL <br />FLOOR PLAN <br />7898 GALL BLVD., <br />ZEPHYRHILLS, FL 32541 <br />STORE #FL-280 <br />DATE <br />ISSUE, 07.03.19 <br />SHEET NO <br />mi <br />■ <br />AA-0003276 <br />%. yumam w. w- w- <br />