Laserfiche WebLink
r <br />HVAC GENERAL NOTES <br />NO EXCLUSIONS FROM OR LIMITATIONS IN THE LANGUAGE USED IN THE CONTRACT <br />DOCUMENTS SHALL BE INTERPRETED AS MEANING THAT THE EQUIPMENT, APPURTENANCES, <br />AND/OR ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM ARE NOT <br />TO BE PROVIDED AS REQUIRED. THE SEPARATE DIVISIONAL CONTRACT DOCUMENTS DO NOT <br />RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY TO PROVIDE THE WORK WHICH IS <br />INDICATED ON ANY OF THE DIVISIONAL CONTRACT DOCUMENTS. REVIEW AND COORDINATE <br />THE SCOPE OF WORK WITH ALL DOCUMENTS AND TRADES TO ASSURE A COMPLETE AND <br />FUNCTIONAL SYSTEM IS BID AND INSTALLED. <br />THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS <br />REQUIRED TO COMMENCE AND COMPLETE HVAC WORK. <br />SUBMIT FULL SUBMITTALS OF ALL HVAC EQUIPMENT AND MATERIALS TO THE ENGINEER FOR <br />REVIEW, WHETHER IT IS EXACTLY AS SPECIFIED OR NOT. <br />THE CONTRACT DOCUMENTS AND SUBMITTALS OF ALL TRADES SHALL BE COORDINATED AND <br />BE VIEWED IN CONNECTION AND CONJUNCTION WITH EACH OTHER TO INSURE THE PROPER <br />LOCATION AND INSTALLATION OF ALL DEVICES AND EQUIPMENT. MAKE PARTICULAR NOTE <br />OF LOCATIONS AND DIMENSIONS SHOWN ON THE ARCHITECTURAL FLOOR PLANS AND <br />ELEVATIONS. <br />HVAC DRAWINGS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE HVAC SYSTEM <br />COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL LOCATION OF THESE <br />COMPONENTS SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR IN COORDINATION <br />WITH THE WORK OF OTHER TRADES, THE USE OF MANUFACTURER'S SUBMITTALS, AND <br />SIMILAR CERTIFIED .DATA. <br />ALL HVAC EQUIPMENT INSTALLED OUTDOORS SHALL BE SECURED TO ITS SUPPORT AS <br />DETAILED BY THE STRUCTURAL ENGINEER FOR THE REQUIRED WIND LOAD DESIGN. <br />ALL EXTERIOR EXPOSED MATERIALS SHALL BE CONSTRUCTED OF NON-FERROUS MATERIALS <br />AND BE PAINTED WITH TWO COATS OF RUST INHIBITOR PAINT. <br />INSTALL AND TEST ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. MAINTAIN ADEQUATE SERVICE <br />SPACE AS REQUIRED. SERVICE SPACE SHALL BE CLEAR OF DUCTS, PIPES, CONDUITS, WALL <br />STUDS, CEILING HANGERS, AND ANY OTHER CONSTRUCTION APPURTENANCE. <br />CONTRACTOR SHALL COORDINATE AND PROVIDE ALL CEILING/FLOOR/WALL ACCESS PANELS <br />THAT MAY BE REQUIRED FOR THE INSTALLATION, INSPECTION, AND SERVICE OF HVAC <br />EQUIPMENT WHETHER OR NOT IT IS SHOWN. ACCESS PANELS TO BE SELECTED BY THE <br />ARCHITECT. <br />ALL WALL MOUNTED THERMOSTATS AND SIMILAR SENSORS SHALL BE INSTALLED AT A <br />CENTER LINE ELEVATION OF 4'-0" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED ON <br />DRAWINGS. LOCATION OF THE SENSORS SHALL BE COORDINATED WITH THE OTHER TRADES <br />FOR A NEAT APPEARANCE. FINAL LOCATION OF .THE SENSORS SHALL BE SUBJECT TO THE <br />APPROVAL OF THE ENGINEER. <br />PERFORM FINAL TESTING AND BALANCING OF ALL HVAC SYSTEMS IN ACCORDANCE WITH <br />AABC OR NEBB STANDARDS. RECORD ALL DATA ON STANDARD "AABC" OR OTHER <br />APPROVED FORMS, AND SUBMIT TO THE ENGINEER FOR REVIEW. <br />AT PROJECT COMPLETION, THE CONTRACTOR SHALL PROVIDE A MINIMUM OF 2 HOURS OF <br />TRAINING ON THE OPERATION AND MAINTENANCE OF THE HVAC EQUIPMENT. <br />CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY ON PARTS AND LABOR FROM THE <br />DATE OF SUBSTANTIAL COMPLETION. <br />EXHAUST AIR DUCTWORK SHALL BE GALVANIZED SHEET METAL. SEAL ALL DUCT JOINTS <br />WITH HARDCAST. <br />ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE LATEST <br />EDITION rr OF SMACNA" DUCT CONSTRUCTION STANDARDS. FABRICATE DUCTWORK TO THE 2" <br />W.G. PRESSURE CLASS AND SEAL TO SEAL CLASS C. <br />DUCTWORKr r AIR DEVICES AND OTHER ITEMS OF THE AIR DISTRIBUTION SYSTEM SHALL BE <br />SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE AND NOT FROM THE CEILING OR <br />P <br />CEILING SUSPENSION SYSTEM. AIR DEVICES SHALL BE SUPPORTED FROM THE BUILDING <br />STRUCTURE FROM AT LEAST TWO POINTS. COORDINATE LOCATION OF AIR DEVICES WITH <br />ALL OTHER TRADES. <br />100 <br />X4X2 <br />i <br />Aitor QC <br />0 �S �. <br />M <br />EAD1 <br />100 O <br />8X8 <br />DG1 <br />EAD1 <br />Q2 200 <br />8X8 <br />3 � E <br />1 <br />I � <br />3 <br />Mwo <br />i1� <br />24X2E <br />3 .. <br />_ <br />9 ...€ <br />�., <br />155 SF <br />_F_..... ;... 6 S <br />r' <br />1 <br />.... .........<.,.... „.. «,,,, i �,,... <br />V <br />� � EAD1 <br />1200 <br />8X8 <br />._ ._ _._ .._.__._.... .. ...... <br />I � I <br />Arbor Mafir� Entry Arbor <br />I � i <br />I <br />g i E I O; I I}j ` <br />t ....._,I �.._._. <br />s <br />f <br />a <br />HVAC SYMBOL _LEGEND <br />SYMBOL <br />DESCRIPTION <br />2 <br />ROUND DUCTWORK SIZE, WHERE THE DIMENSION IS THE INSIDE <br />PLAN VIEW DUCTWORK DIMENSION <br />z <br />EXHAUST AIR CEILING AIR DEVICE <br />—DG-> <br />DOOR GRILLE AIR DEVICE FOR TRANSFER OF AIR, ARROW <br />INDICATES AIRFLOW DIRECTION <br />TAG <br />SUPPLY, RETURN, TRANSFER, OUTSIDE, AND EXHAUST AIR DEVICE <br />SAW AIRFLOW <br />IDENTIFICATION <br />150 --- CFM <br />80 <br />SAD=SUPPLY AIR DEVICE, RAD=RETURN AIR DEVICE, <br />TAD=TRANSFER AIR DEVICE, EAD=EXHAUST AIR DEVICE, <br />f <br />OAD=OUTSIDE AIR DEVICE <br />NECK SIZE <br />TAG <br />1 <br />DG1 AIRFLOW <br />150 --- CFM <br />DOOR GRILLE AIR DEVICE IDENTIFICATION <br />202 <br />DOOR GRILLE SIZE, <br />(LENGTHXHEIGHT) <br />❑T <br />TEMPERATURE SENSOR <br />OS <br />SWITCH <br />FAN SCHEDULE <br />I <br />FAN TAG <br />- <br />EF-T <br />EF-2 <br />EF-3 EF-4 <br />SERVICE TYPE <br />- <br />EXHAUST AIR <br />EXHAUST AIR <br />EXHAUST AIR EXHAUST AIR <br />AIR FLOW <br />CFM: <br />1OG <br />200 <br />200 100 <br />EXTERNAL STATIC PRESSURE <br />IN WG <br />0.5 <br />0.5 <br />0.5, 0.5 <br />FAN TYPE <br />- <br />CEILING <br />CEILING <br />CEILING CEILING- <br />DRIVE TYPE <br />- <br />DIRECT <br />DIRECT <br />DIRECT DIRECT <br />MOTOR <br />HP/BHP <br />66.9 WATTS <br />66.9 WATTS <br />66.9 WATTS 66.9 WATTS <br />SPEED <br />RPM <br />1014, <br />1014 <br />1014 1014 <br />SOUND <br />SONES <br />2,5 <br />2,5 <br />2.5 2.5 <br />VOLTAGE <br />VIPHIHZ <br />12011160 <br />12011160 <br />12011/60' 120/1160 <br />WEIGHT <br />LBS <br />16 <br />16 <br />16 16 <br />MANUFACTURER <br />- <br />COOK <br />COOK <br />COOK COOK <br />MODEL <br />GC488 <br />GC-188 <br />GC-18NOTES <br />- <br />1,2,5,6,7 <br />1,2,4,6,7�EG,C-188 <br />2,4,6,7 1,2,3,6,7 <br />NOTES .._.. <br />1. PROVIDE DISGONNECT. ....................... ... ..... ...... .• ...... ,..... .. _ _.. . <br />2. PROVIDE SOLID STATE SPEED CONTROLLER. ...... ........ .. <br />3. WALL SWITCH PRUVIDED By ELECTRICAL CONTRACTOR_ <br />4 INTERLOC WITH LIGHTS AND EN MINUTE DELAYS SWITCH PROVIDED ED BY <br />ELECTRICAL CONTRACTOR. I <br />5. PROVIDE LINE VOLTAGE THERMOSTAT. <br />6 ITEE O PRVIDW A U U <br />.. _-: _.._::. �._ L MANM GRILLE <br />.. _ _ .............. ...M..... .. <br />F. PROVIDE' BACKDRAFT DAMPER. <br />100 , <br />24X24F, <br />Eqs.' <br />CyEE— <br />i <br />EAD1 <br />O100 <br />8X8 <br />HVAC FLOOR PLAN <br />SCALE: 3/16"40" <br />HVAC. CODE CRITERIA <br />THE FOLLOWING IS A LIST OF ALL CODES ADOPTED DECEMBER 31, 2017 BY THE STATE FIRE <br />MARSHALL'S RULE 69A3.012 F.A.C.: <br />* FLORIDA BUILDING CODE 6TH EDITION (2017) - ALL SECTIONS <br />* FLORIDA ENERGY EFFICIENCY CODE (FBC 2017), FLORIDA ENERGY CODE SOFTWARE: <br />ENERGYGAUGE USA VERSION 6.00 <br />* FLORIDA FIRE PREVENTION CODE 6TH EDITION (2017) <br />69A-3.012 STANDARDS OF THE NATIONAL FIRE PROTECTION ASSOCIATION ADOPTED. <br />(1) EXCEPT AS SPECIFICALLY MODIFIED BY STATUTE OR BY THE STATE FIRE MARSHAL'S <br />RULES, THE "FLORIDA FIRE PREVENTION CODE, 6TH EDITION (2017)," WHICH IS COMPRISED <br />OF THE FLORIDA SPECIFIC EDITION OF NFPA 101, THE LIFE SAFETY CODE (2015 EDITION) <br />AND THE FLORIDA SPECIFIC EDITION OF NFPA 1, THE FIRE CODE (2015 EDITION), ARE <br />HEREBY ADOPTED AND INCORPORATED BY REFERENCE AND ARE APPLICABLE TO THOSE <br />BUILDINGS AND STRUCTURES SPECIFIED IN PARAGRAPHS (A) AND (B) OF SUBSECTION (1) <br />OF SECTION 633.206, F.S. IN ADDITION, THE FOLLOWING STANDARDS, EXCEPT AS <br />SPECIFICALLY MODIFIED IN THE RULE CHAPTERS IN RULE TITLE 69A, ARE HEREBY ADOPTED <br />AND INCORPORATED BY REFERENCE AND SHALL TAKE EFFECT ON THE EFFECTIVE DATE OF <br />THIS RULE, AS A PART OF THE UNIFORM FIRE SAFETY STANDARDS ADOPTED BY RULE BY <br />THE STATE FIRE MARSHAL AND ARE APPLICABLE TO THOSE BUILDINGS AND STRUCTURES <br />SPECIFIED IN PARAGRAPHS (A) AND (B) OF SUBSECTION (1) OF SECTION 633.206, F.S.: <br />* NFPA 70, 2014 EDITION, NATIONAL ELECTRIC CODE <br />* NFPA 90A, 2015 EDITION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING <br />AND VENTILATING SYSTEMS <br />• NFPA 90B, 2015 EDITION, STANDARD FOR THE INSTALLATION OF WARM AIR HEATING <br />AND AIR-CONDITONING SYSTEMS <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS, INC. <br />(ASHRAE) (INCLUDING ALL APPROVED ADDENDUM): <br />ASHRAE FUNDAMENTALS 2017 <br />ASHRAE GUIDELINE 4-2008, PREPARATION OF OPERATING AND MAINTENANCE <br />DOCUMENTATION FOR BUILDING SYSTEMS <br />* ASHRAE STANDARD 111-2008, MEASUREMENT, TESTING, ADJUSTING AND BALANCING OF <br />BUILDING HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS <br />SHEET METAL AND AIR CONDITIONING' CONTRACTORS' NATIONAL ASSOCIATION (SMACNA) <br />(INCLUDING ALL APPROVED ADDENDUM): <br />HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, 3RD EDITION, 2005 <br />HVAC SYSTEM DUCT DESIGN, 4TH EDITION, 2006 <br />OTHER: <br />* LOCAL CODES AND ORDINANCES <br />NOTE: TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THESE HVAC DESIGN DRAWINGS <br />COMPLY WITH THE ABOVE CODE CRITERIA. WHEN TWO OR MORE CODES OR <br />STANDARDS ARE IN CONFLICT, THE MORE STRINGENT SHALL APPLY. <br />EMERALD <br />ENGINEERING INC. <br />9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 <br />TEL (813) 995-0300 FLORIDA E8# 0027845 <br />WWW.EMERALDMEP.COM EEI PROJECT# 180822 <br />Right Wing <br />Pavilion . <br />£ U <br />81 `u, <br />0 CODED NOTES <br />1) REFER TO DETAIL ON THIS SHEET FOR CEILING MOUNTED <br />EXHAUST FAN. <br />2) MOUNT EXHAUST GRILLE IN ROOF OVERHANG SOFFIT. <br />CEILING <br />EXHAUST FAN <br />ATTACH TO <br />BUILDING STRUCTURE. <br />PROVIDE A <br />MINIMUM OF FOUR <br />ANGLES OR <br />FACTORY <br />7r <br />MOUNTING <br />BRACKET(S) FOR <br />HANGING ROD <br />1/4" THREADED ROD. ATTA(WMFMT <br />VERIFY WITH FAN <br />MANUFACTURER <br />FOR FAN WEIGHT. <br />FOR FANS UNDER <br />160 LBS. <br />PROVIDE ISOLATOR <br />BUSHINGS AT <br />ROD/FAN <br />INTERFACE. <br />PROVIDE DUCT <br />TRANSITION AS <br />REQUIRED. <br />EXHAUST <br />DUCT. <br />REFER TO <br />HVAC FLOOR <br />PLANS FOR <br />SIZE. i <br />AIRFLOW <br />EXHAUST <br />FAN <br />FACTORY <br />CEILING <br />GRILLE. <br />/<\ I <br />CEILING <br />NOTE: <br />AIRFLOW FAN TO BE DIRECTLY SUPPORTED <br />FROM BUILDING STRUCTURE ABOVE <br />AND NOT FROM CEILING. <br />AIR DEVICE TAG <br />EADi <br />DG1 <br />SERVICE TYPE <br />EXHAUST AIR <br />TRANSFER AIR <br />DESCRIPTION <br />LOUVERED GRILLE <br />(MINUS FILTER) <br />LOUVERED <br />DOOR GRILLE <br />NECK <br />RECTANGULAR <br />RECTANGULAR <br />AIR FLOW PATTERN <br />1-WAY <br />1-WAY' <br />BLADESIVANES <br />FIXED <br />FIXED <br />MATERIAL <br />ALUMINUM <br />ALUMINUM <br />FINISH <br />WHITE <br />WHITE <br />DAMPER <br />OPPOSED BLADE <br />NONE <br />MANUFACTURER' <br />PRICE <br />PRICE <br />MODEL <br />63OFF <br />ATGH <br />NOTES <br />1,2,3;4 <br />1,34 <br />NOTES <br />1; PROVIDE FRAMES/FLANGES AS RE 01k _..._ <br />Q ED FO R <br />CONSTRUCTION AND AS SELECTED BY ARCHITECT. <br />2. FACE OF AIR DEVICE TO BE HINGED AND CAPABLE TO FLIP <br />DOWN FOR INT RN E AL CLEANING. N. <br />3 COLOR TO BE SELECTED BY HI ARCTECT, <br />4. PROVIDE REMOVABLE INSECT SCREEN. <br />0 8 436 ®s <br />0 <br />� •® E tip m° �C! <br />MICHAEL A CO`STELLO, PE <br />FL. REG. NO. PE81436 <br />U) <br />Z <br />O <br />U^) <br />Lu <br />cc <br />0 <br />■ <br />m <br />cc <br />N <br />Cz <br />Cl) <br />0- <br />a� <br />Mid <br />C/) <br />CIO <br />> <br />MIMI <br />0 <br />-0 <br />CZ <br />-0 <br />Lm <br />o <br />J <br />4) <br />Q <br />Q <br />N <br />N <br />N <br />BSB <br />iN <br />www.bsbdesign.com <br />100 Main St. Suite 209 <br />Safety Harbor, Florida 34695 <br />8132654808 <br />JOB NO: AM180320.00 PROJ MGR: MC <br />DRAWN: CQ CHECKED: MC <br />HVAC FLOOR PLAN <br />