Laserfiche WebLink
ui <br />i <br />i <br />/,/MIjlmllm <br />cO <br />HEADROOM <br />OR (2) <br />SLOPED PLANE <br />W ADJOINING <br />TREAD NOSING— <br />::3 <br />FROM FLOOR Q <br />SURFACE OF <br />LANDING <br />FOR 51: 1 INCH = 25.4 mm, 1 FOOT = 304.8 mm, <br />IN I�'u-1 HEAFT )F00t-1 <br />w <br />FOR 51: 1 INCH = 25.4 mm. <br />CONVENTIONAL_ 5T,41 FUJ,4T' <br />EAC+4 FLIGHT <br />REGULATED ON ITS OUN <br />DIFFERENCE BETWEEN <br />GREATEST AND SMALLEST <br />TREAD DEPTH WITHIN A <br />FLIGHT OF STAIRS 15 <br />LIMITED TO 3/0". <br />DIFFERENCE BETWEEN HIGHEST AND <br />° LOWEST RISERS WITHIN A FLIGHT OF <br />STAIRS IS LIMITED TO 3/0'. <br />FOR 61: 1 INCH = 25.4 mm. <br />STT41f TOLEF�,)ANCES <br />6-0x6-8 SGD <br />3'-O'x 3'-0' PATIO <br />CON. PAD <br />#REAR UNIT ONLY, <br />REAR UNIT CONFIG. - ST. CROIX <br />SCALE: 1/4" = 1'-0" <br />6'-1 1/2' 1 L 9'-4 1/4' <br />4'-II' L I 1 04 3/4" <br />12nd !=.F <br />I <br />M � <br />Ti <br />2x6 P.T. LEDGER <br />o <br />2x6 CONY. FRAMING e I6' <br />O/C W/ U5P HU526 <br />W/ I/4' x 2 3/4' <br />HANGER AT EACH END <br />TAPCON5 � 16' O/C <br />_ <br />g 3/4' <br />14 RISERS 1 1/2" EACH PLUS <br />- <br />zt <br />I R15ER g 1 3/4" M <br />'HALF W/ Ix6 <br />14 TREADS 9 9.15" EACH <br />WALL <br />WOOD CAP (SEE I <br />I , <br />TOTAL HEIGHT = 9'-4 3/4' <br />STAIR PAGE FOR I <br />2 RISERS + 1 TREAD <br />= <br />HANDRAIL INFO.) <br />GREATER THAN 24' d NOT TO EXCEED 25' <br />(2)1 1/2' + 9 3/4' <br />= 24 3/4" <br />LANDING <br />NOT TO INCLUDE <br />I' NOSING. <br />STAIR DETAIL - 1370/1371 - ST. CROIX <br />SCALP: 1/4" = 1'-0" REFER TO SHEET 'STAIR' FOR INFORMATION NOT 5HOWN <br />11'-10 1/2' <br />3'-II 1/2' <br />B <br />1A <br />LANDING <br />I <br />LIVING ROOM <br />� <br />uP <br />_ <br />U) <br />N <br />KNEE II <br />WALL <br />n <br />m <br />14'-2' <br />1 3'-5 1/2' <br />r <br />DRAIN PAN, <br />r <br />N <br />DRAIN TO <br />OUT SIDE OF <br />UNIT. (5EE LU.H. <br />61.0 FOR <br />e <br />1'-4- I'-V T-10' '-0' <br />10'-4"-f1RE5eURE <br />LAYOUT) <br />�J TP <br />1/2 BATN <br />I RELIEF <br />O <br />= <br />A CIA <br />TILE C <br />-_--- <br />T. - <br />Ll <br />8'-4 1/2' l <br />e <br />m <br />T.B. jl <br />IL <br />ICO�n <br />I� w <br />IAOT D+ <br />I 4'-8 1/2' 2'-II <br />12"x12' <br />O.H.C. I' -II 1/2 <br />1/2" <br />it <br />m <br />1/2 WALL 39 1/2" <br />W/COUNTER <br />ABOVE a 42" A.F.F. <br />16" WIDTH <br />COUNTER ABOVE. <br />1A <br />42" KNEE WALL <br />g W/ 1" x (0" <br />= WOOD CAP <br />J' <br />- <br />= <br />�cl <br />`n <br />- <br />j <br />0 <br />L _ _ <br />O <br />3-0x6-8 <br />I OPEN'G u <br />? <br />FLAT HDR. o <br />N <br />0 <br />DINING ROOM <br />Lj <br />KITCHEN <br />2" x 12° <br />IT-2 1/2' <br />N <br />2 <br />1'-5 1/2' <br />SEE DETAIL "A" <br />FOR REAR UNIT <br />CONFIG. <br />- <br />1 <br />X RE " <br />1/2 34 SH <br />r <br />(2) 25 514 <br />GONG, PAD <br />10'-4' 4'-10' <br />3'-0. <br />21'-10' <br />1 st FLOOR PLAN - 1370/1371 - ST. CROIX <br />SCALE : 1/4" = 1'-0" <br />nPFU 11J� <br />s <br />N <br />M <br />tl i l 1, /A In. <br />KITCHEN PASS-THRU - ST. CROIX <br />SCALE : 1/4" = I'-0" <br />TO WATER <br />SERVICE <br />S <br />`'+s M, BATN o w <br />GPT. TILE o o <br />I m <br />30" <br />LuBASEVANITY <br />2T" <br />0 <br />MA5TER 537E M.C. / <br />-0 A <br />:%UE3:/SIH:0WER <br />;_ <br />---- <br />T.P. <br />5'-10 1/2' 3'-2' 3'-6 1/4' j 5'-3 3/4' <br />BATN <br />5 1/2' WALL �6+ 30' BA50 m <br />6 VANITY <br />2-4x6-8 <br />I I cnLuQ° <br />I HAN5EN <br />cx I BOX ---- <br />DRYER I tv v M.C.e <br />VENT w .n m F-LOGA- INS <br />(SEE NOTE51 (FIELD 22"X3�" KNEE WALL <br />IITILE G T I MIN. I <br />R/S <br />- — — — — — — — — <br />Xx2 <br />— <br />V <br />5-0x6-8 <br />BF 71/2', <br />-6x6-8 3-Ox6-8E3F-0"'-5. 3'-3 1/2' 3'-li' I, <br />5EDROOM3 5EDRO0M2 <br />I <br />25 5H HD. 25 SH HD. <br />HGT. 6'-10' HGT- 6'-10" <br />6'-31, *EGRESS 9'-8' *EGRE55 5'-II' <br />21'-10' <br />2 2nd FLOOR PLAN - 1370/1371 - ST. CROIX <br />SCALE : 1/4" = 1'-0' <br />WASHER <br />.HIV 112" <br />DOMESTIC WATER SUPPLY <br />SCALE: N7.5. <br />PLUMBING LEGEND <br />------------- -- VENT LINE <br />= SANITARY WASTE LINE <br />= GOLD WATER SUPPLY <br />—�--� = HOT WATER SUPPLY <br />NOTE: LICENSED PLUMBER TO VERIFY <br />AND HAS THE AUTHORITY TO <br />CHANGE AS NEEDED. <br />Ji �4" VTR <br />I <br />I <br />2" <br />2" <br />I i WASH <br />211 <br />I <br />I V I <br />, <br />LAV <br />BUILDING <br />WALL <br />TO <br />SEWER <br />SYSTEM <br />SANITARY WASTE RISER DIAGRAM <br />SCALE: N.T.5. <br />FLOOR PL,4N NOTES <br />I. WALL DIMENSIONS ARE FROM OUTSIDE FACE <br />OF BLOCK WALL TO INSIDE FACE OF <br />INTERIOR WALL. <br />2. DETERMINE THE LOCATION OF PARTITIONS <br />NOT DIMENSIONED BY THEIR RELATION TO <br />COLUMN FACE OR CENTER WINDOW JAMB <br />OR OTHER SIMILAR FIXED ITEM. <br />1, EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW <br />THAT COMPLIES WITH EGRE65 CODES, IF <br />THERE 15 NO ACCESS TO EXTERIOR <br />THROUGH A DOOR, THE WINDOW MUST HAVE <br />A MAXIMUM SILL HEIGHT OF 44' ABOVE <br />FINISH FLOOR LINE OF THAT PARTICULAR <br />ROOM <br />2. ALL INTERIOR ANGLED WALLS ARE AT 45. <br />U.N.O. <br />3- ISSUANCE OF PLANS FROM THIS DESIGNERS <br />OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY <br />ALL NOTES, DIMEN51ON5, AND ADHERENCE <br />TO APPLICABLE BUILDING CODES PRIOR TO <br />COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY DI5GREPANCY OF ERROR IN NOTES, <br />DIMENSIONS, OR ADHERENCE TO <br />APPLICABLE BUILDING CODES SHALL BE <br />BROUGHT TO THE ATTENTION OF THE <br />DESIGNERS OFFICE FOR CORRECTION <br />BEFORE COMMENCEMENT OF ANY <br />CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT <br />RELATED TO THE CORRECTION OF ERRORS <br />THAT ARE MADE AFTER THE FINAL PLANS <br />HAVE BEEN COMPLETED SHALL BE 5U5JECT <br />TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO <br />THESE PLANS BY ANY OTHER PARTY OTHER <br />THAN THE DESIGNERS OFFICE, THE DESIGNER <br />SHALL NOT BE HELD RESPONSIBLE. <br />4. EACH DWELLING UNIT 8 GARAGE UNIT TO BE <br />EQUIPTED W/ PORTABLE FIRE EXTINGUISHER <br />IN ACCORDANCE W/ NFPA10 <br />5. DRYER VENT NOTE: <br />INSTALL BOOSTER FAN IN THE ATTIC TO <br />ACCOMMODATE THE EXCESS LENGTH OF <br />THE DRYER VENT TO COMPLY WITH <br />SECTION M1501.3 F.R.C. LOCATE 50 AS TO <br />BE ACCESSIBLE. <br />DIMEN510N CONVENTION <br />OVERALL s EXTERIOR OPENING DIMENSION <br />FROM OUTSIDE OF BLOCK <br />OUTSIDE FACE OF <br />a" <br />NOMINAL BLOCK <br />3 1/2" FRAME WALL <br />U.N.O. <br />AREA TABULATION <br />UNIT 5T. CROIX <br />let FLOOR LIVING (091 5F, <br />2nd FLOOR LIVING 680 5F, <br />TOTAL LIVING 1311 S.F. <br />ENTRY 21 5F. <br />GARAGE 0 5F, <br />TOTAL 50, FT. 1392 &F. <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.donscoengineering.com <br />o <br />O <br />Ln <br />zt.-0 <br />>rn <br />Z� M <br />�O=L-1i <br />Z Ce <br />z�E <br />W <br />W <br />W 3~ <br />z <br />o <br />0 <br />Lo <br />Lu U j <br />v) <br />O U <br />1 = V) <br />Z � <br />I �= 1 <br />1 <br />1 szO <br />w 1 <br />Q <br />U <br />Z v� <br />Q01) <br />U <br />LJJ <br />I <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />2007 FLORIDA RESIDENTIAL BUILDING CODE <br />(INCLUDING 2009 SUPPLEMENT) SECTION <br />R301 FOR 120 MPH, 3 SEC. GUST, EXPOSURE <br />"C" ENCLOSED (INTERNAL PRESSURE <br />COEFFICIENT=±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />2W9 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. — - <br />2009-THESE DRAWINGS AND DESIGNS ARE THE JOINT <br />PROPERTY OF DANSCO ENGINEERING, LLC AND THE <br />CLIENT ON THIS PROJECT. ANY REPRODUCTION OR <br />UNAUTHORIZED USE IS PROHIBITED. <br />I <br />REVISION: <br />DAT0DE_SCRIPTION <br />09-29-09 1.00 2007 FBC UPDTATES <br />I I� <br />I <br />II <br />j VERSION NO. 1.00 / 09.29.09 <br />CA 25948 <br />SAMUEL A. GREENBERG, <br />P.E. #34245 <br />THUY H. HUYNH, <br />P.E. #60122 <br />IRWIN J. BENSON, <br />P.E. #49758 <br />ANDREW D. HAROLD, <br />P.E. #66715 <br />ENGINEER SEAL: <br />SHEET TITLE: <br />INDIVIDUAL UNIT <br />1370/1371 - ST. CROIX <br />I <br />SHEET INFORMATION: <br />JOB NO.: 291041 <br />1 <br />DATE ISSUED: 09.28.09 <br />I <br />DRAWN BY: DZ <br />REVIEWED BY: TH <br />I 1 <br />I <br />