Laserfiche WebLink
/'�j <br />c0 <br />HEADROOM <br />Q OR (2) <br />U 5LOPED PLANE <br />w ADJOINING <br />} TREAD NOSING <br />o � <br />lU i3 <br />FROM FLOOR Q <br />SURFACE OF <br />LANDING i <br />FOR 51: 1 INCH = 25.4 mm, I FOOT = 304.0 mm. <br />1�1 I N l t-IL i—f 14E 41DfR001-1 <br />FOR SI: 1 INCH = 25.4 mm. <br />CONI/EN71 ONAL ST41 FUJ4T' <br />EACH FLIGHT <br />REGULATED ON IT5 OWN <br />GREATEST <br />MALLE5T <br />DIFFERENCE BETWEEN <br />GREATEST AND SMALLEST <br />TREAD DEPTH WITHIN A <br />FLIGHT OF STAIRS IS <br />LIMITED TO 3/5" <br />DIFFERENCE BETWEEN HIGHEST AND <br />° LOWEST RI5 <br />ER5 WITHIN A FLIGHT OF <br />STAIRS IS LIMITED TO 3/8', <br />FOR 51: 1 INCH = 25.4 mfr. <br />5fi4f T0L=EfR4NGE5 <br />2 RISERS + 1 TREAD - <br />T-4' GREATER THAN 24" 4 NOT TO EXCEED 25' <br />(2)1 1/2' + 9 3/4' - 24 3/4' <br />T-8 3/4' NOT TO INCLUDE I' NOSING. <br />14 RISERS a 1 I/2' EAGH <br />PLUS 1 R15ER a 13/4" <br />14 TREADS is 9 3/4' EACH <br />TOTAL HEIGHT = 9'-4 3/4' 2nd FF, <br />I <br />v9 cn <br />\ r <br />I (3) 2x12 5YP SPACED <br />LANDING � EVENLY W/ CONTRUCTION <br />ADHESIVE PL200 4 2-16d <br />3/ ' TOE NAILS AT EACH END <br />zO\\ v <br />C) 6' <br />`2x12 P.T. W/ T "' a 42' HALF WALL W/ Wo <br />1/4'x2 3/4' \� _ 1 WOOD CAP (SEE STAIR <br />TAPGONS PAGE FOR HANDRAIL <br />AT 16' O.G. \ INFO) <br />I5t F.E. <br />9'-4 1/4' <br />STAIR DETAIL - 1530 - SIESTA KEY <br />SCALE: I/4" = 1'-0" REFER TO SHEET 'STAIR' FOR INFORMATION NOT SHOWN <br />4'-0' <br />/I9DCAIIAI(1 Ait IMF <br />OVERHEAD <br />CABINETS <br />KITCHEN PASS-THRU - SIESTA KEY <br />SCALE : 1/4' = 1'-0" <br />14'-6' <br />Y-0' 10140' <br />3'-0"x3'-0(0 ° <br />CONC. PAD <br />------ <br />2x4 WALL <br />STOR. c COVERED PATIO <br />s x <br />-0" 3'-10, 5'-4" M. 0, <br />I <br />NB 5-Ox6-81 <br />' 00 D.W. <br />p 1 SINK <br />I W/ DISP _ <br />I n m <br />z °o KITCHEN r- <br />I 0 I <br />I <br />o REF. <br />L— — — — — — — — — _ <br />D.H.C. u, <br />�m i= <br />N }- <br />U <br />2'-6' = 4'-0" 3'-S' 4'-4' <br />1e 119 WALL a 39 1/2' W/COUNTER <br />ABOVE a 42' A.F.F. <br />16" WIDTH COUNTER ABOVE. <br />DINING ROOM <br />4'-3' <br />DRAIN PAN, <br />DRAIN TO OUT <br />SIDE OF UNIT. <br />(5EE 51.0 FOR <br />-LAYOUT) <br />1 6'-4 1/2' <br />PED. <br />/2 <br />4" ARCH <br />SPRING 6'-S' <br />TO 7-4" <br />- - - - <br />- - - - <br />I <br />UNDER T.B. <br />�' <br />I <br />STAIRS 1/2 BATH <br />TIL_yCPt. <br />S <br />l I— —I <br />r <br />W.H. <br />m <br />11 I, I Xi I O U <br />I I I T.P. <br />2'-1 1/2' g m 4" ARCH, <br />I <br />REIIEFURE <br />SPRING 6'-8" <br />_ <br />LANDING UP TO 1'-4' <br />b <br />A <br />� <br />1B <br />5'-0 3/4" <br />L <br />II WALL II <br />N <br />LIVING ROOM <br />I <br />FOYER <br />(2) 25 SHT- <br />* EGRESS <br />0 <br />ENTRY <br />ro = <br />I 25 SH <br />_`r * EGRE55 <br />N <br />1 st FLOOR PLAN - 1530 - SIESTA KEY <br />SGALE : 1/4" = I'-0` <br />L 14'-6" <br />(2) 25 SH <br />HD. HGT, 6 -10' <br />* EGRE55 <br />I i <br />I <br />m I <br />� I I <br />BEDROOM 2, <br />I . <br />I I <br />I <br />I <br />I <br />T-9' - <br />N <br />m <br />I <br />2-(Ox6-8 <br />I <br />N I <br />e STUDY 1 <br />I Ilan <br />DRYER VENT 1 1 ° <br />(SEE NOTES) IT <br />HANSEN <br />2'-9 1/2' 5'-10, BOX I' -II' 1 3'-II1/2' <br />A/C <br />CHASE = <br />DRYER ASHE'Q� > <br />5-0x6-a BF <br />Iz x I <br />g,i b IQ <br />T�zI <br />Q BATH <br />I W <br />481 BASE e�,�ECPT. <br />VANITY <br />W.c. <br />LA <br />Q T T.P. ° M.C. <br />LANDING DC IWN <br />3' 10" 3'-2 1/2, 3'-11 1/2' <br />A/R <br />LANDING I I > 'X <br />_� <br />IA <br />/WA L <br />t2-(ox(o <br />II 5,45E <br />o T. ® NITY <br />*/ M.G.-8IE3 <br />ILEM. B>4TN� <br />x <br />10'-61/2" <br />N <br />I <br />N A/C <br />CHASE I <br />I <br />N I I <br />M,45TER SUITE - I � I <br />I >n <br />I I � <br />2'- 1/2' 11'-11 1/2' 13 <br />- I � <br />I I <br />I <br />I <br />1 I <br />I <br />I <br />24/5 5H <br />e HD. HGT, <br />6'-10' <br />I <br />25 SH <br />HD, HGT. 6'-10' <br />* EGRESS <br />v I <br />2nd FLOOR PLAN - 1530 - SIESTA KEY <br />SCALE : 1/4" = 1'-O° <br />I <br />WASHER <br />TUB NJ J <br />I <br />LAV. 1/2" <br />I <br />I ' <br />11z' <br />J Ir <br />1 ` KIT. <br />TU � t �' <br />LAV. J 112" <br />LAV. � J <br />WC <br />112" <br />H.W.H. 112" �y <br />4 WC <br />TO <br />WATER <br />SERVICE <br />DOMESTIC WATER SUPPLY <br />SCALE: N.T.5, <br />PLUMBING LEGEND <br />= VENT LINE <br />= SANITARY WASTE LINE <br />= COLD LUATEER SUPPLY <br />—Hv—Hv—w = HOT WATER SUPPLY <br />NOTE: LICENSED PLUMBER TO VERIFY <br />AND H45 THE AUTHORITY TO <br />CHANGE AS NEEDED. <br />VTR i �112" VTR <br />I I <br />1 2 � I <br />2" <br />1 1/2" <br />ru5; i `I WAS <br />I I I " 2I <br />I � I :__1 <br />�11/2" <br />Tq LAV <br />11/2" 2" 1 WC <br />I I 1 112" � <br />2" LAV <br />I I <br />I I <br />I I <br />WC <br />BUILDING <br />WALL <br />TO <br />SEWER <br />SYSTEM <br />SANITARY WASTE RISER DIAGRAM <br />SCALE: N.T.5. <br />FLOOR PLAN NOTE5 <br />I. WALL DIMENSIONS ARE FROM OUTSIDE FACE OF BLOCK WALL <br />TO INSIDE FACE OF INTERIOR WALL. <br />2. DETERMINE THE LOCATION OF PARTITIONS NOT <br />DIMENSIONED BY THEIR RELATION TO COLUMN FACE OR <br />CENTER WINDOW JAMB OR OTHER SIMILAR FIXED ITEM. <br />I. EGRE55 NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES <br />WITH EGRESS CODES, IF THERE 15 NO ACCE55 TO <br />EXTERIOR THROUGH A DOOR THE WINDOW MUST HAVE A <br />MAXIMUM SILL HEIGHT OF 44' ABOVE FINISH FLOOR LINE <br />OF THAT PARTICULAR ROOM <br />2. ALL INTERIOR ANGLED WALLS ARE AT 45. U. N. 0. <br />3. 155UANCE OF PLANS FROM T45 DESIGNERS OFFICE SHALL <br />NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW <br />AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO <br />APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT <br />OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR <br />ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE <br />BROUGHT TO THE ATTENTION OF THE DESIGNERS OFFICE <br />FOR CORRECTION BEFORE COMMENCEMENT OF ANY <br />CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE <br />CORRECTION OF ERRORS THAT ARE MADE AFTER THE <br />FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT <br />TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY <br />ANY OTHER PARTY OTHER THAN THE DESIGNERS OFFICE, <br />THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. <br />4. EACH DWELLING UNIT 4 GARAGE UNIT TO BE EOUIPTED W/ <br />PORTABLE FIRE EXTINGUISHER IN ACCORDANCE W/ NFPAIO <br />5. DRYER VENT NOTE: <br />INSTALL BOOSTER FAN IN THE ATTIC TO ACCOMMODATE <br />THE EXCE55 LENGTH OF THE DRYER VENT TO COMPLY <br />WITH SECTION M15013 F.RG. LOCATE SO AS TO BE <br />ACCESSIBLE. <br />DIMENSION CONVENTION <br />OVERALL 4 EXTERIOR OPENING DIMEN51ON <br />FROM CJT5IDE OF BLOCK <br />OUTSIDE FACE OF 6' <br />NOMINAL BLOCK <br />31/2' FRAME WALL U.N.O. <br />,4RE,4 T,45UL,4TION <br />UNIT SIESTA KEY <br />15t FLOOR LIVING 154 SF. <br />2nd FLOOR LIVING 117 5F. <br />TOTAL LIVING 1531 5F. <br />ENTRY 45 5F. <br />COVERED PATIO 69 SF. <br />STORAGE IS SF. <br />TOT4L 60. ET, 1603 5F. <br />F <br />I <br />I � <br />I I I <br />I� <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f.813.645.9698 <br />www.donscoenginee(ing.com <br />I <br />Lin <br />w <br />zi~o <br />o Ln <br />�og� 1 <br />CL Lu <br />0 r 00 <br />J <br />00 <br />zZc~i1 moow <br />I W <br />z <br />0 <br />�o <br />w U <br />N <br />I i <br />! 0 U <br />I <br />Z <br />C; <br />� C <br />1 05 <br />Z <br />1 <br />0 <br />I <br />Q L <br />0 U <br />Z J) <br />I <br />U <br />J <br />V) <br />1 L1J <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />2007 FLORIDA RESIDENTIAL BUILDING CODE <br />(INCLUDING 2009 SUPPLEMENT) SECTION <br />R301 FOR 120 MPH. 3 SEC. GUST, EXPOSURE <br />"C- ENCLOSED (INTERNAL PRESSURE <br />COEFFICIENT = ±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VAUD FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />2009 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />- - <br />2009-THESE DRAWINGS AND DESIGNS ARE THE JOINT <br />PROPERTY OF DANSCO ENGINEERING, LLC AND THE <br />CLIENT ON THIS PROJECT. ANY REPRODUCTION OR <br />UNAUTHORIZED USE IS PROHIBITED. <br />1 <br />— <br />REVISION: <br />} DESCRIPTION I <br />DATE <br />09-29-09 <br />1.00 2007 FBC UPDTATES <br />L - <br />i VERSION_ NO. 1.00 / 09.29.09 <br />� -- - -- - ---- - <br />CA 25948 <br />❑ SAMUEL A. GREENBERG, <br />P.E. #34245 <br />THUY H. HUYNH, <br />P.E. #60122 <br />IRWIN J. BENSON, <br />P.E. #49758 <br />I <br />ANDREW D. HAROLD, <br />P.E. #66715 <br />ENGINEER SEAL: <br />I <br />II <br />1 <br />I <br />ti <br />SHEET TITLE: <br />INDIVIDUAL UNIT ! <br />1530 - SIESTA KEY <br />SHEET INFORMATION: <br />JOB NO.: 291041 <br />DATE ISSUED: 09.28.09 <br />DRAWN BY: DZ <br />REVIEWED BY: TH j <br />I <br />I B <br />W- 4 <br />V- 4 <br />4t <br />H <br />D <br />m <br />.--1 <br />arl <br />N <br />1 <br />to <br />I <br />O <br />e_-1 <br />