Laserfiche WebLink
u/ <br />/ <br />/ <br />/ <br />/ <br />/ Z <br />/ <br />/ MINIMUM c° <br />HEADROOM <br />OR (2) <br />SLOPED PLANE <br />v ADJOINING <br />o TREAD NOSING <br />/ <br />FROM FLOOR a / <br />SURFACE OF / <br />LANDING / <br />FOR 51: 1 INCH = 25.4 mm, I FOOT = 304.0 mm. <br />FOR 51. 1 INCH = 25.4 mm. <br />CONVENTIONAL 5T,41fRUJ4'' <br />EACP FLIGHT <br />REGULATED ON ITS OWN <br />GREATE5T <br />71 <br />5MALLE5T <br />DIFFERENCE BETWEEN <br />N GREATEST AND SMALLEST <br />Lu <br />TREAD DEPTH WITHIN A <br />FLIGHT OF STAIRS 15 <br />LIMITED TO 3/8". <br />DIFFERENCE BETWEEN HIGHEST AND <br />° LOWEST RISERS WITHIN A FLIGHT OF <br />STAIRS 15 LIMITED TO 3/8", <br />FOR 51: 1 INCH = 25.4 mm, <br />,5T,41f;,D TOL-EiR,4NCE5 <br />1'-6' <br />1 61 <br />9' 3'-3' <br />3/4' PLYWOOD OVER <br />2x6 FRAMING W/(2) IOd HVAC - � \ 42' HALF <br />a EA. END. I WALL W/ I x 6 <br />1 WOOD CAP <br />TOP OF A/C PLATFORM I <br />m <br />2nd F.F. r — I <br />--fl— <br />GIRDER <br />BEYOND <br />FRAMED KNEEWALL TO 5UPPORT A/C <br />PLATEFORM (5HOWN DASHED) LANDING <br />2 RISERS 41 TREAD = LANDING <br />/ � i �i <br />GREATER THAN 24' E NOT TO <br />EXCEED 25" <br />(2)1 I/2' + 9 3/4" = 24 3/4' co C�L <br />a / 2xl2 P.T. W/ 1/4' x <br />NOT TO INCLUDE I' NO51NG. 1 = 2 3/4' TAPCON5 <br />4 RISERS 9 1 I/2' EACH / AT 16" O.C. <br />PLUS I R15ER 9 1 3/4' 42' HALF <br />1 / (3) 2 x 12 SYP'2 <br />14 TREADS 9 9.15' EACH 1 WALL W/ I x 6 SPACE EVENLY W/ <br />ISf. F.F. <br />TOTAL HEIGHT = 9'-4 3/4' / WOOD CAP CON5TRUCTION <br />T-3 3/4' 3' 6' ADHESIVE PL200 E <br />2- 16d TOE NAILS <br />10'-9 3/4' AT EACH END <br />A� STAIR DETAIL - 1531 - MARTINIQUE <br />SCALE: 114" = 1'-0" REFER TO SHEET 'STAIR' FOR INFORMATION NOT SHOWN <br />5'-2' <br />I1-51. nP;:m1KIr1 2"_Q" <br />CABINETS <br />—I --- ---- ----- <br />- I II <br />I II <br />i II <br />- I II II <br />KITCHEN II <br />KITCHEN PASS-THRU - MARTINIQUE <br />SCALE : 1/4" = 1'--0" <br />14'4' <br />II'40' <br />3'-0"x6'-,a' <br />GONG. PAD <br />(2) 25 SH <br />HD. HGT. 6' 1(0° <br />* EGRESS <br />I <br />10. <br />I <br />COVER 1�AT10 <br />I <br />I I <br />I <br />SfiOR. <br />I <br />i <br />i <br />BEDROOM 2 <br />6-0x6-8 5GD H.B. <br />fy_ Q <br />= <br />N <br />1 <br />6'-4" M.O. T-9" <br />— <br />I1/2" <br />II'-B 1/2' <br />2'- <br />I <br />I <br />I <br />T P. <br />Av <br />ty 1-6X6- W.C. Q — <br />2-6X6- B 0 n' 13Lu <br />tL1 v <br />LIVING ROOM C T1 E 30 BASE o o M <br />VANITY <br />5AT�4 m-A m I <br />T5 <br />10'-10, <br />I I I I <br />II w <br />I Lu <br />DRYER VENT I I LONAT I i IT z a FLEX 5PACE I <br />(SEE NOTES) s <br />FIELD I I I x I— <br />3'-8' 10'-I0' 122'X36' 1 1 19 OL <br />4'-6 1/2' � MIN. J <br />PED. SINK I I <br />4' ARCH, WG• ,� � 4'-10 3/4' 5'-11 1/4" <br />SPRING 6'-8' 0`­=� <br />T.P. � <br />TO 1'-4' • X I �3 <br />GPT.TT LE HANSEN N �' <br />BOX HALF DO JN <br />`" WALL LANDING <br />1/2 5ATH ASHE _ <br />-0 I/2' 4'- 1/2"-3'-4" M <br />4' ARCH, -- A A/R HVAC — — — — A <br />SPRING 6'-8' I I - <br />UP I I W.H. �c - 1c <br />TO 1'-4' I = LANDING <br />Y <br />-------� 2-6x6- <br />77LJ� <br />4'-101/2' ��+ ° TP T-B- o <br />LAv 0 - tu <br />M.C. W.C. p ut <br />HALF FRE55URE DRAIN PAN, I ,�, I GPT TILE 48" BASE `_" o o m <br />WALL RELIEF DRAIN TO OUT VANITY m w m <br />51DE OF UNIT.+� N <br />DINING ROOM (SEE 51,0 LAYOOR I I M. 5AD4 <br />N <br />/2 WALL 0 39 I/2" W/COUNTER R/5— <br />ABOVE a 42" AF.F. B O 16" WIDTH COUNTER ABOVE. 18 - 6-Ox6-a BF cl <br />6-21/2' /-I 1/2" <br />10'-10, <br />_ _ I A/C <br />CHAGE <br />N REF.— --------- i = N <br />KITCHEN <br />CPT. I I TILE I <br />V�RKFST � <br />CID�'I OPENING z on 6, @ MASTER SUITE <br />t FLAT HEADER a C) <br />\ 2'-1' V-5' = <br />-6X6 SINK W/ DI5P <br />BF u <br />r 5/SH I D.W.— 00 <br />o <br />LO) <br />%33 SH 24/5 5H <br />coHD. HGT. <br />ENTRY6xR ] m 25 514 <br />_ HD. HST. 6 -10" <br />*EGRESS <br />25 5H 1(o X16'X24' <br />HIGH SQUARE <br />2'-1" 3'4 4' S' 4'-2' COLUMN BASE 2'-T 3'-1' 2'-11' <br />W/ 12" ROUND <br />Ir PILASTER <br />ABOVE. <br />1 st FLOOR PLAN - 1531 - MARTINIQUE <br />SCALE : 1/4" = 1'-0" <br />2nd FLOOR PLAN - 1531 - MARTINIQUE <br />SCALE : 1/4" = 1'-0" <br />LAV. <br />TUB <br />1, h4' \ � <br />I <br />wC � ML <br />I <br />I <br />LAV. <br />I <br />1/2" <br />TUB 1/2" /��, ' LAV. <br />I I <br />we <br />wc� <br />WASHER 11 I I <br />wT I <br />� I <br />KIT. H.W.H. 1/2" �+ 1/2" <br />4WC '> <br />112"� <br />I �- <br />�/ 1 <br />TO , <br />WATER <br />SERVICE <br />DOMESTIC WATER SUPPLY <br />SCALE: N.T.5. <br />PLUMBING LEGEND <br />= VENT LINE <br />= SANITARY U),ASTE LINE <br />= COLD U)ATER SUPPLY <br />—�— —Rv = NOT WATER SUPPLY <br />NOTE: LICENSED PLUMBER TO VERIFY <br />AND HA5 THE AUTHORITY TO <br />CHANGE A5 NEEDED. <br />VTR <br />I <br />I <br />V i VTR \�C 2" <br />n` 2" <br />1� 2" I I 3" I I <br />LAV I I t �\ I I <br />I � I W I I <br />2" " <br />I I TU <br />3" I I LAV I " <br />1 <br />W � � I•� 2„ 2VTR <br />.\ I <br />3" 4" <br />JI TUB 2" I l <br />I I <br />2' I CO <br />l w 3" <br />KIT. I `` 3" <br />4• <br />CO WASH <br />BUILDING 2" 4 " <br />WALL <br />TO 4" <br />ry SEWER I <br />SYSTEM <br />SANITARY WASTE RISER DIAGRAM <br />SCALE: N.T.5. <br />FLOOR PLAN NOTES <br />I. WALL DIMENSIONS ARE FROM OUTSIDE FACE OF BLOCK WALL <br />TO IN511DE FACE OF INTERIOR WALL. <br />2. DETERMINE THE LOCATION OF PARTITIONS NOT <br />DIMENSIONED BY THEIR RELATION TO COLUMN FACE OR <br />CENTER WINDOW JAMB OR OTHER SIMILAR FIXED ITEM. <br />I. EGRE55 NOTE: <br />EACH BEDROOM MIJ5T HAVE ONE WINDOW THAT COMPLIES <br />WITH EGRESS CODES, IF THERE 15 NO ACCE551 <br />EXTERIOR THROUGH A DOOR THE WINDOW MU5T HAVE A <br />MAXIMUM SILL HEIGHT OF 44' ABOVE FINI5H FLOOR LINE <br />OF THAT PARTICULAR ROOM <br />2. ALL INTERIOR ANGLED WALL5 ARE AT 45• U. N. 0. <br />3. 155UANCE OFF PLAN5 FROM THIS DE5IGNER5 OFFICE 5HALL <br />NOT RELIEVE THE BUILDER OF RE5PON51BILITY TO REVIEW <br />AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO <br />APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT <br />OF ANY CONSTRUCTION. <br />ANY D15CREPANCY OF ERROR IN NOTES, DIMENSIONS, OR <br />ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE <br />BROUGHT TO THE ATTENTION OF THE DE5IGNER6 OFFICE <br />FOR CORRECTION BEFORE COMMENCEMENT OF ANY <br />CON5TRUCTION. <br />ANY REV1510N5 OR CHANGES, NOT RELATED TO THE <br />CORRECTION OF ERRORS THAT ARE MADE AFTER THE <br />FINAL PLAN5 HAVE BEEN COMPLETED SHALL BE SUBJECT <br />TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLAN5 BY <br />ANY OTHER PARTY OTHER THAN THE DESIGNERS OFFICE, <br />THE DESIGNER SHALL NOT BE HELD RE5PON515LE. <br />4. EACH DWELLING UNIT 8 GARAGE UNIT TO BE EQUIPTED W/ <br />PORTABLE FIRE EXTINGUISHER IN ACCORDANCE W/ NFPAIO <br />5. DRYER VENT NOTE: <br />INSTALL BOOSTER FAN IN THE ATTIC TO ACCOMMODATE <br />THE EXCE55 LENGTH OF THE DRYER VENT TO COMPLY <br />WITH SECTION MI5013 F.R.G. LOCATE 50 A5 TO BE <br />ACCE55115LE. <br />DIMENSION CONVENTION <br />OVERALL 3 EXTERIOR OPENING DIMENSION <br />FROM OUTSIDE OF BLOCK <br />OUTSIDE FACE OF 8' <br />NOMINAL BLOCK <br />31/2" FRAME WALL UXO. <br />AREA T45UL4TION <br />UNIT MARTINIQUE <br />15t FLOOR LIVING 754 5.F. <br />2nd FLOOR LIVING 771 S.F. <br />TOTAL LIVING 631 5.F. <br />ENTRY 45 S.F. <br />COVERED PATIO 69 S.F. <br />STORAGE 18 5� <br />TOTAL 50. FT, 1663 5F. <br />� 1 <br />i I <br />i <br />I <br />I <br />I <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645,9698 1 <br />www.donscoengineering.com <br />i <br />o <br />Ln <br />w <br />OTC <br />ci <br />Z Qmt� <br />M 00 <br />J <br />YS, Z <br />`o <br />Z E <br />EE <br />_j wto <br />W z <br />0 <br />J CD <br />�o <br />I <br />W u <br />` V <br />O <br />�U <br />I <br />Z V) <br />OZ� <br />I � <br />1 <br />O <br />EL <br />0 U <br />Z v� <br />Q U <br />V) <br />W 1 <br />I <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />2007 FLORIDA RESIDENTIAL BUILDING CODEJ� <br />(INCLUDING 2009 SUPPLEMENT) SECTION <br />R301 FOR 120 MPH, 3 SEC. GUST, EXPOSURE <br />"C" ENCLOSED (INTERNAL PRESSURE <br />COEFFICIENT=±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />2009 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />2009-THESE DRAWINGS AND DESIGNS ARE THE JOINT <br />PROPERTY OF DANSCO ENGINEERING, LLC AND THE <br />CLIENT ON THIS PROJECT. ANY REPRODUCTION OR <br />UNAUTHORIZED USE IS PROHIBITED. <br />_REVISION:Ii <br />DATE DESCRIPTION <br />09-29-09 1.00 --- FB --- <br />2007 FBC UPDTATES <br />- <br />I <br />VERSION NO. 1.00 / 09.29.09 <br />CA 25948 --- - _ - <br />SAMUEL A. GREENBERG, <br />P.E. #34245 <br />I <br />THUY H. HUYNH, <br />P.E. #60122 <br />I <br />1RWIN J. BENSON, <br />P.E. #49758 <br />ANDREW D. HAROLD, <br />P.E. #66715 <br />ENGINEER SEAL: <br />I <br />I <br />SHEET TITLE: <br />INDIVIDUAL UNIT <br />1531 -MARTINIQUE <br />SHEET INFORMATION: <br />JOB NO.: 291041 <br />DATE ISSUED: 09.28.09 <br />DRAWN BY: DZ <br />REVIEWED BY: TH <br />1 C <br />•—+ <br />.-4 <br />Z <br />H <br />m <br />a-� <br />N <br />1 <br />Ln <br />I <br />O <br />a_4 <br />V-4 <br />