Laserfiche WebLink
1UNIT-A :1:53:2] <br />�1UNIT-C 1624 <br />1UNIT-C 1624 <br />SYMMETRICAL <br />NOTE: <br />• SEE D1 SHEET FOR TYPICAL ROOF FRAMING DETAILS <br />• SEE SHEET 10 FOR BUILDING ROOF LAYOUT <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />p <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 (1) PLY <br />1450 (2) PLY <br />7 -10d x 1 1/2" <br />6-16d x 31/2" <br />HTA20 <br />1870 <br />1730 <br />9 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PL <br />10 -10d x 1 1/2" <br />14-16d x 31/2" <br />(2)HTA20 <br />2430 <br />9 -10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1730 <br />9 - 10d x 1 1/2" <br />C <br />H2.5A <br />700 <br />615 <br />10 - 8d x 2 1/2" <br />RT7A <br />630 <br />510 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />365 <br />8 - 8d x 2 1/2" <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />8 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1495 <br />9 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 -10d x 1 1/2" <br />RT16A <br />1025 <br />900 <br />9 -1Od x 1 1/2"& 8-1Od <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18)1/4" x 3"SDS WOOD SCREWS AND <br />2 10 x 5" TITEN HD ANCHOR BOLTS <br />RFUS <br />7100 <br />(12) W 3 WOOD SCREWS & <br />(4) 3/4" x 6" WEDGE -BOLTS <br />J <br />HT75 <br />4350 <br />3740 <br />5/8" ANCH. / (26)10dx1-1/2" <br />HTT45 <br />5795 <br />5/8" ANCH. /(26)10d x2-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" ANCH./ (2) 5/8" STUD BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />5/8" ANCH./ (2) 5/8" STUD BOLT <br />L <br />VGT R/L <br />2225 <br />1600 <br />(16) 1/4"xYSDS WOOD SCREWS & <br />HDU4-SDS2.5 w/ (10)1/4"x2.112" SDS <br />WOOD SCREWS & (1) 5/8" ATR <br />--- <br />M <br />VGT - F <br />4940 <br />3555 <br />-- <br />--- <br />N <br />LUS26 <br />1165/1150 `* <br />865/785 ** <br />8 - 10d x 3" <br />JUS26 <br />1050/1080** <br />840/950** <br />(8) -10d x 3" <br />P <br />HUS26 <br />1320/3280 ** <br />1150/2780 ** <br />20 -16d x 3 1/2" <br />HUS26 <br />2045/3400 <br />1640/2990** <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1480/3520 ** <br />30 -16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />— <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />850 <br />14 -1Od x 1 1/2" <br />MTW12 <br />965 <br />810 <br />14-10d x 1-1/2" <br />S <br />VGT - M* <br />4940 <br />3555 <br />(16)114"x3"SDS <br />1) 5/8" ATR EPDXIED w/ SIMPSON <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />& (8) 3/8N5" TITEN HD (2 PLY) or <br />52 16d SINKERS FRAME <br />U <br />MGT -M* <br />3965 <br />3330 <br />(22)10d x 3" w/ (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" EPDXY <br />MUGT15 <br />4240 <br />3730 <br />(28)10d x 3" (1) 5/8" ATR wl 12" <br />EMBED w/ USP CIA-7000C EPDXY <br />W <br />MGT -F^ <br />V <br />(2) LGT2 <br />4060-M 4080 F <br />3500 M 3510 F <br />�22PLY) or 60)"10d x 3-14&SINKERS @ FRAM TITEN TURBO <br />LUGT2 <br />3310-M 4040 F <br />2920 M 3560 F <br />SCRIEW BO T (10) 1/4"x3"DEWALT <br />or (64)10d x 3' @ FRAME <br />"X" <br />HTS 20 <br />1415 <br />1215 <br />(16)-1Od x 1 1/2" <br />HTW20 <br />1355 <br />1140 <br />24-1Od x 1 1/2" <br />SP1 <br />555 <br />535 <br />10 -10d x 3" <br />SPT22 <br />735 <br />8 -10d x 3" <br />SP2 <br />1 1010 <br />605 <br />12 -10d x 3" <br />SPT24 <br />1090 <br />12 -10d x 3" <br />HCP2 <br />1 590 <br />1 510 <br />1 12-1Od x 1 1/2" <br />HHCP2 <br />680 <br />595 <br />(20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 03-14-22 <br />LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+1- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING POINT <br />SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) TRUSS TO THE <br />TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). INTERSECTING POINT <br />TO BE FASTENED w/ (2) -16d COMMON NAILS OR 0.128" x 3" GUN NAILS. FASTEN BOTTOM CHORD <br />OF (B) TRUSS TO TOP CHORD (A) CARRIER TRUSS 2x CONT. SCAB SO. PINE w/ THE SAME SPECIFIED <br />COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK LUMBER <br />(LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED FOR HIP PLANING <br />TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS INTERSECTIONS. <br />SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK FRAMING <br />SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ENGINEERED <br />CLADDING WIND PRESSURES AND SUUCTIIONIS GN FORM AN ROOFOMPONENTS HEIGHT 15 5 ftND <br />ALLOWABLE <br />RSH <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE <br />WIND PRESSURE AND SUCTION (PSF) <br />HIP ROOF >20 TO 45 DEG. <br />WIND AREA <br />(+) VALUE DENOTES PRESSURE <br />(SQ FEET) <br />(-) VALUE DENOTES SUCTION <br />[4:12]-[12:12] <br />a=oft <br />AREA <br />ROOF <br />1 <br />2e <br />2n <br />2r <br />3 <br />3e <br />3r <br />• <br />HIP <br />-35.94 <br />-49.57 <br />-49.57 <br />-49.57 <br />. <br />10 <br />GABLE <br />-38.22 <br />-38.22 <br />-60.99 <br />-60.99 <br />-60.99 <br />-78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />r <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />r <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />0 <br />Q <br />SHINGLE: %fi' EXP. 1 (24/6) or 1%2' EXP. 1 (32/16) <br />TILE: 15/32" EXP. 1 H/16) <br />r <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y8" x 0.113") NAILS <br />" <br />3r <br />r <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1 Y32", SHEATHING SHALL BE FASTENED <br />" <br />WITH ASTM F1667 RSRS-03 10d (2cY2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />a=4ft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />[4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />ROOF FRAMING PLAN — STANDARD (STD <br />SCALE: )/4'"=11-0" <br />CCA 09/24/2020 <br />era <br />N <br />.r• <br />� o <br />;a <br />'! W <br />ZC3 <br />L ." <br />u ati o <br />V N <br />m iC <br />.. _ LA_o <br />N 10 O L <br />N -p N t <br />Q w tV <br />3 ca <br />E � c <br />0 <br />m <br />L <br />iv y o rx <br />= a+ <br />1= �= a <br />N d <br />= E <br />o <br />� v <br />>ti <br />w <br />C*7 <br />N <br />0 <br />N <br />CV <br />O <br />0 f, <br />♦ .• <br />No PE7 750 <br />•� <br />ST OF �•+U: <br />,� 0 R 1 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />v) <br />E P cq <br />Q � P_ <br />1 0 <br />Q <br />LL LL z <br />0 <br />Z t v O <br />�• j (p N <br />M <br />LL "j � N Z < = <br />�n N U rA i- <br />"= O U ❑�❑ <br />W <br />o <br />z <br />Z o <br />� <br />v <br />a � <br />A <br />M <br />Vi Z o <br />C1 <br />fy U_ o <br />ro � <br />ro w W <br />C <br />U <br />$ <br />0 wLn <br />Ln C m <br />I1('/11 <br />U jam <br />w <br />= <br />m$ <br />® <br />I z <br />U <br />C .0 Y <br />Q <br />C <br />N <br />I� <br />o <br />Jz <br />M0 <br />o <br />z <br />� <br />co E <br />zo <br />o <br />a p <br />U <br />wz <br />F� <br />_ <br />E <br />�0 <br />�r <br />00 <br />O U <br />o¢ <br />z <br />d <br />w p <br />w w <br />C13c <br /><o <br />W� <br />z <br />m j <br />maw <br />z <br />W <br />oLL <br />m w <br />00 <br />N <br />3 <br />o <br />¢ <br />w14, <br />iI° <br />A <br />a� <br />03 <br />c <br />o T <br />7n <br />W M�/� <br />TT <br />rn <br />N <br />� <br />� <br />CD <br />CV <br />cN <br />M t\ <br />LO <br />T <br />T <br />s <br />r <br />� <br />CO <br />VJ m <br />T <br />I— <br />0 <br />LO <br />CIO <br />LO <br />04 CVo <br />CD <br />C� <br />� <br />Q N <br />L.0 ) <br />CD <br />r <br />Z N <br />C:) <br />o <br />Z <br />m <br />Z <br />7 N <br />E Co r <br />ct! <br />0- <br />E Co <br />o m <br />U _j Q a <br />c <br />c <br />4) <br />JOB <br />NO :23-13131-13136 <br />SCALE : AS NOTED <br />SHEET NO. <br />10.1 <br />