My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36410 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36410 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:30:03 AM
Creation date
2/19/2025 1:52:01 PM
Metadata
Fields
Template:
Building Plans
Street #
36410
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W�lu <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16"AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699, <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FqF <br />W.P. WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />�4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />© EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />P� PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />owl ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />HE <br />I <br />B( <br />I I <br />LAV 1\ <br />I <br />TUB/ <br />W/C SHOWER <br />3" VTR <br />�L <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I <br />I <br />tj W/C <br />ILI <br />SHOWER <br />—3" ` end F FC <br />STUDOR �R <br />VENTp '' Y11 DBL SINK <br />L W/ DISP. <br />LAV I W/C z.l <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />st 10 KW at o <br />1 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA t <br />200 AMP <br />• rrr� un ui <br />1 �0-200 Aly P I IT/ —Serial Cable <br />C.O. <br />3R <br />Power Co. Feed #4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br /><�j,�`� <br />FAN/LIGHT <br />v GFI <br />\ GFI <br />r I I <br />DINING I <br />I <br />I <br />I KITCHEN <br />I� <br />FI 0 rGE1—j <br />--- GFI � --- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK C.M <br />� II <br />I <br />\ I <br />GREAT ROOM <br /><A\ /,>ROUGH -IN\ <br />FOR OPT. CH <br />FAN/LIGHT , <br />I / <br />UPSTAIRS <br />1 / <br />rVYf` <br />FOYER <br />I I <br />I <br />I DB <br />ENtRY 0— <br />LIGNTAS UO WFI& <br />PER SPECS <br />DB&GFI TO <br />BE ALIGNED <br />VERTICALLY / <br />LU <br />H <br />\ LU Z <br />LLOLU <br />CrV� <br />>0m <br />GFI <br />@ 44" <br />` <br />W.H. <br />A.F.F. <br />' <br />\ 0 <br />1 <br />I <br />I GARAG E <br />I <br />1 <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />I <br />I J <br />LU <br />bZ <br />I <br />I <br />F a <br />I <br />I <br />Oa <br />I <br />N � <br />I <br />w <br />I <br />Dw <br />I <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: Y"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />F— <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />OWNER'S <br />BEDROOM <br />��� /�>ROUGH-IN <br />f FOR OPT. <br />FAN/LIGHT <br />\ <br />S.D <br />0. BATH <br />BATH 2 <br />"'�-17 <br />WIC _ \ <br />- 1 <br />I <br />L---- ------ <br />L <br />-----------, <br />I <br />I <br />L V JW WC I <br />V�M <br />\ II II `- <br />I <br />LOFT `i <br />C.M � <br />S.D <br />I <br />I <br />I <br />^\� /^TROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />\BEDROOM 2 <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: Y4"=1'-0" <br />a+nl <br />+tJD <br />c <br />> <br />E <br />c ee W N <br />-p�sa <br />N R O ►. <br />a;g c <br />u 3 <br />o �c <br />N <br />c E� <br />m � <br />AD- Lo <br />0 <br />ch <br />0 <br />N <br />N <br />0 <br />No P 787,0";� <br />yCID <br />' S AT E <br />OF IU <br />:. <br />(� <br />" <br />?• i <br />T <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />E Cs 04 <br />p N r 04 <br />V <br />Lo <br />04 <br />� oCOOUE *1R <br />0) <br />0 <br />rnhh0 —LL W ' <br />� 0 CL LU <br />Q <br />� <br />U LL LL a c7 <br />z <br />13 <br />0 <br />t mo 0 o <br />i <br />t Fe _ <br />W 04 a. <br />W <br />2�pjJ <br />Z <br />IL <br />� F <br />N Z <br />Z <br />OU ❑0❑ <br />Z <br />W <br />V M <br />Z N C8 <br />Z � <br />Z n <br />CD <br />J — <br />Q � <br />E3 <br />V^)' <br />z oC1 <br />W <br />o <br />LU <br />_ �pp <br />O <br />W p <br />V) <br />�N <br />= .) <br />, <br />U <br />W <br />J <br />E <br />t 8 <br />I <br />i <br />z� <br />d <br />a <br />see <br />6 <br />¢ <br />M <br />y zaz <br />65 <br />Z <br />g <br />LL <br />a <br />z. <br />W <br />-0 <br />zo <br />a N <br />0 <br />(J <br />of <br />zE <br />r <br />z® <br />oa <br />(U <br />CL <br />O E <br />¢� <br />az <br />wK <br />00 <br />&Z <br />Z <br />co m <br /><° <br />w <br />QS <br />cn <br />r <br />m0 <br />o� <br />Z <br />m J <br />m <br />¢w <br />$ 3 <br />of <br />go <br />W <br />3 <br />oLLLL <br />az <br />�w <br />o <br />w� <br />w` <br />_0 <br />69 <br />o <br />ZIP <br />d <br />o <br />o T <br />> 00 <br />ui <br />m <br />CN <br />C.p <br />,-- <br />CV <br />CID <br />LM <br />r <br />T <br />T <br />�-' <br />C� <br />O <br />'^ro v, m0*4 <br />r <br />0 <br />L0 <br />M <br />11.0 <br />T <br />0 <br />CD <br />v, <br />ai <br />E <br />j <br />C`V <br />C) <br />o <br />Z <br />Z <br />E O <br />N <br />r <br />a. <br />E <br />U � <br />¢ p <br />� <br />JOB <br />NO :23-13131-13136 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />r <br />