Laserfiche WebLink
A/C <br />DIS( <br />0 <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /411 = 1'-0„ <br />LEC <br />ITER <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED !N NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />OCT 28 ZDZt <br />Virtual Review Assist. Inc. <br />Plans Review completed and approved <br />4 <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne i(lahr P912300 <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH <br />■ <br />Uj <br />4 1 /2" <br />DOORJAMB <br />DUPLEX <br />OUTLET ih <br />TRIM--- <br />BASE— <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />kS <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT 1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />-69- SWITCH AT 36" <br />� 3 WAY SWITCH AT 36" <br />44-2 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />-{] PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />{�- CLG MNT PREWIRE - FIXTURE BY OWNER <br />- SURFACE MNT FIXTURE <br />-�- WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />�4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />06 50W MR16 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />CS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />— U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />5724:;? 24" VANITY LIGHTING <br />9;;-m 36 -;;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 A/C REGISTER <br />(D THERMOSTAT <br />iD SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />a)'n E <br />o <br />} <br />0 <br />0 <br />2) m <br />N <br />t ' P <br />V m co <br />Er- =2 <br />g 2 8 <br />°"0 �� <br />�^N, <br />S U <br />w Q� o <br />W <br />L cO E ri O) <br />70 <br />a <br />(� W <br />w <br />W� W _j W 2 O <br />�02JQ0QMQ�V00_j0 <br />Q Q <br />F- <br />U <br />0 ZLLLLOopF- 0WHOZO000zz <br />zQLLLL <br />QQZ) <br />c, <br />v)o V5wwW�oo¢OZJ <br />W55KWQaa. <br />�_;<WO�U) <br />OW o Z§ <br />Q <br />O <br />O <br />Z CN <br />OF_ <br />O <br />F_: co O <br />Q U) M LO <br />� U) LL <br />F- W c`7 <br />Z00 <br />V� <br />W <br />W <br />JQ <br />O <br />N <br />I <br />I <br />I <br />I <br />I <br />I <br />O <br />N <br />N <br />N <br />N <br />N <br />o <br />0 <br />0 <br />0 <br />0 <br />ti <br />co <br />M <br />M <br />O <br />M <br />N <br />� <br />N <br />' <br />' <br />O <br />Z <br />O <br />O <br />— <br />O <br />O <br />i <br />i <br />' <br />O <br />N <br />LO <br />LoW <br />> <br />o <br />— <br />0 <br />0 <br />0 <br />0 <br />I <br />I <br />It <br />' <br />CO <br />Cr <br />U <br />zZ <br />v^ <br />J <br />Q z <br />w <br />O <br />W <br />o zz <br />0) <br />�--� <br />O <br />U <br />woo <br />U0�5 <br />Lo <br />F_ <br />O <br />7-)Zj <br />OF-0 <br />Z <br />awa <br />Q <br />r <br />W=Q <br />Ln <br />(9 <br />F-~� <br />(V <br />W <br />zoo <br />■ ■ <br />W <br />i' <br />n- <br />QF-0 <br />2-2 <br />CIO <br />O <br />zw0 <br />O <br />z <br />v <br />�Zu- <br />a <br />F-z <br />Z <br />X2 <br />OU <br />0 <br />W <br />z <br />z <br />w <br />W <br />J <br />rl- <br />N <br />0 <br />LAST PLOT DATE <br />■ . <br />July 21, 2022 <br />z <br />O <br />1ST FLOOR <br />ELECTRICAL PLAN <br />