REVISIONS
<br />8-13-08
<br />Mf� ADE M1AMI-DARE COUNTY, FLORIDA
<br />BUILDING CODE COMPLIANCE OFFICE ( BCC.0) METRO-DADE RI,AGLER BUILDING
<br />PRODUCT CONTROL DIVISION 140 WEST FI.AGLER STREET, SUITE 1603
<br />MIAMi, FLORIDA 33130-1563
<br />NOTICE OF ACCEPTANCE (NOA) (305) 375-2901 FAX (305) 375-2908
<br />GAF Materials Corporation -
<br />1361 Alps Road.
<br />Wayne, NJ 07470
<br />SCOPE:
<br />This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
<br />The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
<br />by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
<br />the Authority Having Jurisdiction (AHJ).
<br />111is NOA shall not be valid after the expiration date stated below. 1'he Miami -Dade County Product Control
<br />Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
<br />have this product or material tested for quality assurance purposes. If this product or material fails to perform in
<br />the accepted manner, the manufacturer will incur the expense of such testing and the AIN may immediately
<br />revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
<br />to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
<br />material fails to meet the requirements of the applicable building code.
<br />This product is approved as described herein, and has been designed to comply with the Florida Building Code,
<br />including the Iligh Velocity Hurricane Zone of the Florida Building Code.
<br />DESCRIPTION: Timberline® Prestique® 40
<br />LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
<br />following statement: "Miami -Dade County Product Control Approved", wiless otherwise noted herein.
<br />RENEWAL ofthis NOA shall be considered after a renewal application has been filed and there has been no
<br />change in the applicable building code negatively aiT'ecting the performance of this product.
<br />TERMINATION Of this NOA will occur after the expiration date or if there has been a revision or change in the
<br />materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
<br />product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
<br />with any section of this NOA steal l be cause for termination and removal of NOA.
<br />ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
<br />the expiration date may he displayed in advertising literature. If any portion of the NOA is displayed, then it shall
<br />be clone in its entirety.
<br />INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
<br />and shah be available for inspection at the job site at the request of the Building Official.
<br />This renews NOA #07-0507.10 and consists of pages I through 4.
<br />The submitted documentation was reviewed by Alex Tigera.
<br />APPROVED
<br />MIAMI
<br />DADE
<br />BUILDING CODE COMPLIANCE OFFICE. (BCCO)
<br />PRODUCT CONTROL. DIVISION
<br />NOTICE OF ACCEPTANCE (NOA)
<br />ROOFING SYSTEM APPROVAL
<br />Categor:
<br />Roofing
<br />Sub -Category:
<br />07310 Asphalt Shingles
<br />Materials
<br />Dimensional
<br />Deck Tvuc:
<br />Wood
<br />I. SCOPE
<br />This renews GAF Timberline Prestique 40 as manufactured
<br />by GAF Materials Corp described in
<br />Section 2
<br />of this Notice of Acceptance.
<br />2. PRODUCT DESCRIPTION
<br />Product Dimensions
<br />Test
<br />Product Description
<br />Specifications
<br />Timberline Prestique 13t/,"x 393/B-
<br />TAS 110
<br />Fiberglass reinforced heavy weight
<br />asphalt roof
<br />40
<br />shingle, with a laminate profile
<br />3. EVIDENCE SUBMITTED:
<br />Test Agency
<br />Test Identifier
<br />Test Name/Report
<br />Date
<br />Center for Applied Engineering
<br />PA 100
<br />02/23/94
<br />Underwriters Laboratories, Inc.
<br />ASTM 3462
<br />ASTM D3462
<br />09/13/06
<br />PRI Asphalt Technologies, Inc.
<br />ASTM D3462
<br />GAF-102-02-02
<br />11/02/05
<br />Underwriters Laboratories, Inc.
<br />PA 107
<br />Modifed ASTM D 3161
<br />04/13/94
<br />Center for Applied Engineering
<br />ASTM D3462
<br />03/18/97
<br />PRI Asphalt Technologies, inc.
<br />TAS 100
<br />6AF-045-02-01
<br />01 /13/04
<br />PRi Asphalt Technologies, inc.
<br />GAF-102-02-01
<br />11/14/05
<br />Underwriters Laboratories, Inc
<br />TAS 107
<br />04NK04273
<br />02/20/04
<br />Underwriters Laboratories, Inc
<br />Modified ASTM D3161 OSCA42840
<br />11/11/05
<br />4. LIMITATIONS
<br />4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
<br />Directory for fire ratings of this product.
<br />4.2 Shall not be installed on roof mean heights in excess of 33 ft.
<br />4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida
<br />Building Code and Rule 9B-72 of the Florida Administrative Code.
<br />5. INSTALLATION
<br />5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
<br />5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115
<br />5.3 The manufacturer shall provide clearly written application instructions.
<br />5.4 Exposure and course layout shall be in comp lianec with Deta]I'A', attached.
<br />5.5 Nailing shall be in compliance with Detail'B', attached.
<br />6. LABELING
<br />6.1 Shingles shall be labeled with the Miami -Dade Product Control Approved Seal or the wording
<br />"Miami -Dade County Product Control Approved".
<br />7. BUILDING PERMIT RF,QUIREMENTS
<br />7.1 Application for building permit shall be accompanied by copies of the following:
<br />7.1.1 This Notice of Acceptance.
<br />7.1.2 Any other documents required by the Building Official or the applicable code in order
<br />to properly evaluate the installation of this system.
<br />8. MANUFACTURING PLANTS
<br />8.1 Tampa, Fi,
<br />8.2 Michigan City, IN
<br />DETAIL A
<br />134
<br />1„
<br />82 r
<br />f
<br />1
<br />DETAIL R
<br />Front Side (Maximum Slope 12:12)
<br />4 F-
<br />6„
<br />LL
<br />_ 1
<br />5-5
<br />--
<br />6 fasteners 72„ 712 „
<br />7 -
<br />L
<br />1/2"
<br />f ..-
<br />Front Side (Maximum Slope 21:12)
<br />Tab Sealant
<br />21,
<br />L
<br />Back Side
<br />END OF THIS ACCEPTANCE
<br />- Release
<br />Tape
<br />- Release
<br />Tape
<br />18"
<br />3/8"
<br />NOA No.:07-1120.14
<br />NOA No.:07-1120.14
<br />NOA No.:07-1120.14
<br />NOA No.:07-1120.14
<br />Expiration Date: 04/22/13
<br />Expiration Date: 04/22/13
<br />Expiration Date: 04/22/13
<br />Expiration Date: 04/22/13
<br />Approval Date: 05/o8/08
<br />M 1 . �. rr Approval Date: 015/08/08
<br />MIA•D,A MIDECOUN Approval Date: 05/08/08
<br />' "'' '
<br />MIAMI•DADEC uNrY Approval Date: 05/08/09
<br />"' • ' Page 4 4
<br />Page 2 of 4
<br />Page 3 of 4
<br />of
<br />Page 1 of 4
<br />MIAMI-DADS COUNTY, FLORIDA
<br />METRO-DADE FLAGLER BUILDING
<br />140 WEST FLAGLF.R STREET, SUITE 1603
<br />MIAMI, FLORIDA 331_M-1563
<br />(305) 375-2901 FAX (305) 375 2908
<br />GAF Material Corporation
<br />1361 Alps Road
<br />Wayne, NJ 07470
<br />SCOPE:
<br />This NOA is being issued under the applicable rules and regulations governing the use of construction
<br />materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building
<br />Code and Product Review Committee to be used in Miami Dade County and other areas where allowed
<br />by the Authority Having Jurisdiction (AHJ).
<br />This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
<br />Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
<br />reserve the right to have this product or material tested for quality assurance purposes. If this product or
<br />material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
<br />and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
<br />their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
<br />County Product Control Division that this product or material fails to meet the requirements of the
<br />applicable building code.
<br />This product is approved as described herein, and has been designed to comply with the Florida Building
<br />Code and the High Velocity Hurricane Zone of the Florida Building Code.
<br />DESCRIPTION: GAF Deck -Armor Underlayment
<br />LABELING: Each unit shall bear a permanent label with the manufacturer's narne or logo, city, state
<br />and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
<br />herein.
<br />RENEWAL of this NOA shall be considered after a renewal application has been tiled and there has
<br />been no change in the applicable building code negatively affecting the performance of this product.
<br />TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
<br />change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
<br />endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
<br />this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
<br />NOA.
<br />ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
<br />followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
<br />displayed, then it shall be done in its entirety.
<br />INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
<br />distributors and shall be available for inspection at the job site at the request of the Building Official.
<br />This NOA consists of pages 1 through 4.
<br />The submitted documentation was reviewed by
<br />NOA No.: 06-0606.04
<br />Expiration Date: 10/12/11
<br />Approval Date. 10/12/06
<br />Page 1 of 4
<br />ROOFING ASSEMBLY APPROVAL APPROVED ASSEMBLIES:
<br />Category Roofing Deck Type 1: Wood, Non -insulated
<br />Sub -Category: Underlayment Deck Description: `y/32" or greater plywood or wood plank
<br />Material: Polypropylene
<br />System A(1): Leak Barrier is installed as per current NOA approval at vulnerable leak areas.
<br />Deck -Armor Membrane is subsequently installed. Standard installation, no
<br />TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: exposure to rain/snow prior to installation of the Surface Roofing Assembly
<br />Product Dimensions Test Product
<br />minimum slope: 4"on 12".
<br />Specification Description Leak Barrier: Install Weather Watch@ or Stol mGuard@ leak barrier as per current NOA
<br />Deck -Armor 54" x 222' rolls ASTM D 226 A UV -stabilized polypropylene breathable approval at all vulnerable leak areas, this incl odes but is not limited to all eaves,
<br />Type H underlayment. To be used for roof deck valleys, rakes, skylights, and dormers.
<br />protection as an underlayment in sloped roof Membrane: One or more plies of Deck -Armor underlayti nt membrane with a minimum 3"
<br />assemblies. side lap and 6" end lap. Place th(, first course of membrane parallel to the eave.
<br />Weather Watch 36" x 50' rolls ASTM D 1970 Granular Surfaced modified, Fiberglass Fasten side and end laps with approved nails and tin caps 6" o.c. and fasten middle
<br />36" x 67' rolls reinforced, bituminous sheet material for as of the roll with approved nails and tin caps 1 o.c. in two staggered rows, in the
<br />an underlayment in sloped roof assemblies. field of the roll.
<br />Designed as an ice & rain shield Surfacing: Approved Roofing Assembly.
<br />Storm Guard 36" x 66.7' rolls ASTM D 1970 Modified, fiberglass reinforced, bituminous
<br />sheet material for as an underlayment in Deck Type 1: Wood, Non -insulated
<br />sloped roof assemblies. Designed as an ice
<br />& rain shield Deck Description: '9132" or greater plywood or wocxl plank
<br />System A(2): Leak Barrier is installed as per cuurent NOA :-pproval at vulnerable leak areas.
<br />Deck -Armor Membrane is subsequently instal led. Special installation, for
<br />EVIDENCE SUBMITTED: exposure to rain/snow prior to installation of the Surface Roofing Assembly
<br />minimum slope: 2"on 12".
<br />Test Agency Test Identifier Test Name/Report Date Leak Barrier: Install Weather Watch® or StorinGuardo� leak harrier as per current NOA
<br />approval at all vulnerable leak aj eas, this includes but is not limited to all eaves,
<br />PRI Asphalt Technologies, Inc. GAF-025-02-01 ASTM D 1970 03/26/2002 valleys, rakes, skylights, and dot viers.
<br />PRI Asphalt Technologies, Inc. GAF-026-02-01 ASTM D 1970 03/26/2002 Membrane: One or more plies of Deck -Armor underlayment membrane with a minimum 3"
<br />side lap and 6" end lap. Place tho first course of membrane parallel to the cave.
<br />PRI Asphalt Technologies, Inc. GAF-112-02-01 ASTM D 226 Type II 03/15/20!)6 Fasten side and end laps with approved nails :-nd tin caps 6" o.c. and fasten middle
<br />of the roll with approved nails altd tin caps 121" o.c. in two staggered rows, in the
<br />field of the roll. If roof is exposed to rain/snow, tape all end and side laps with
<br />approved butyl adhesive based s,•am/cover tale or an approved waterproof cloth
<br />duct tape (fallow the tape manulacturer's installation instructions). Always apply
<br />tape over all fasteners at the censer of the roll or the laps to help prevent rain or
<br />snow from entering at the fasten •rs.
<br />Surfacing: Approved Roofing Assembly.
<br />CRA NOA No.: 06-0606.04AV%NOA No.: 06-0606.04
<br />Y Expiration Date: 10/12/11 ry Expiration Date: 10/12/11
<br />Approval Date: 10/12/06 Eta Approval Date: 10/12/06
<br />Page 2 of 4qW Page 3 of 4
<br />LIMITATIONS:
<br />1. Fire classification is not part of this acceptance.
<br />2. Deck-Arnior shall not he used as roof tile underlayment.
<br />3 This acceptance is for prepared roofing applications. Minimum deck requirements shall be in
<br />eotnpliane a with applicable building code. Deck -Armor shall be installed in strict compliance with
<br />applicable Building Codes and Manufacturers' specifications and guidelines.
<br />4. Deck-Arnlor shall he applied to a smooth, clean and dry surface with deck free of irregularities.
<br />5. Deck -Armor shall not be applied over an existing roof membrane.
<br />6 Deck Armor Mate shell not be left exposed as a temporary roof for longer than 14 days of
<br />application.
<br />7. All nails in the deck shall be carefully checked for protruding heads. Re -faster, any loose decking
<br />panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
<br />8. Deck Armor may he used with any approved roof covering; Notice of Acceptance listing Deck -Armor
<br />as a component part of an assembly in the Notice of Acceptance. if Deck -Armor is not li,ted, a
<br />request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product
<br />Control Department for approval provided that appropriate documentation is provided to detail
<br />compatibility of the products. wind uplift resistance, and fire testing results.
<br />9. When applying the membrane in the valley, start at the low point and work to the high point, rolling
<br />the membrane from the center outward in both directions.
<br />10. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
<br />Product Control Notice of Acceptance and applicable Building Code.
<br />11. All memhranes shall bear the imprint or identifiable marking of the manufacturer's name or logo, or
<br />following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade logo.
<br />END OF THIS ACCEPTANCE
<br />NOA No.: 06-0606.04
<br />Expiration Date: 10/12/11
<br />Approval Date: 10/12/06
<br />Page 4 of 4
<br />ALL RIMS RESERVE
<br />CORDA & ASSOCIATES ARCHffECrS®2008 COPYRIOH
<br />o
<br />�
<br />t o
<br />�a¢
<br />8
<br />M�
<br />�
<br />W
<br />�T,
<br />H
<br />W
<br />o
<br />N
<br />h+i
<br />CD
<br />o
<br />I
<br />►--i
<br />00
<br />I
<br />00
<br />00
<br />u7
<br />wrn
<br />w
<br />J
<br />o.
<br />CIDz
<br />to
<br />z
<br />U
<br />Cw
<br />z
<br />w
<br />�
<br />a
<br />�-
<br />rN
<br />O
<br />DATE. 5/30/08
<br />SCALE: AS N OTE I ,
<br />JOB NO.: 27013
<br />SHEET:
<br />A2111
<br />i
<br />01 22 _SHEET
<br />0
<br />
|