Laserfiche WebLink
REVISIONS <br />8-13-08 <br />Mf� ADE M1AMI-DARE COUNTY, FLORIDA <br />BUILDING CODE COMPLIANCE OFFICE ( BCC.0) METRO-DADE RI,AGLER BUILDING <br />PRODUCT CONTROL DIVISION 140 WEST FI.AGLER STREET, SUITE 1603 <br />MIAMi, FLORIDA 33130-1563 <br />NOTICE OF ACCEPTANCE (NOA) (305) 375-2901 FAX (305) 375-2908 <br />GAF Materials Corporation - <br />1361 Alps Road. <br />Wayne, NJ 07470 <br />SCOPE: <br />This NOA is being issued under the applicable rules and regulations governing the use of construction materials. <br />The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted <br />by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by <br />the Authority Having Jurisdiction (AHJ). <br />111is NOA shall not be valid after the expiration date stated below. 1'he Miami -Dade County Product Control <br />Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to <br />have this product or material tested for quality assurance purposes. If this product or material fails to perform in <br />the accepted manner, the manufacturer will incur the expense of such testing and the AIN may immediately <br />revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right <br />to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or <br />material fails to meet the requirements of the applicable building code. <br />This product is approved as described herein, and has been designed to comply with the Florida Building Code, <br />including the Iligh Velocity Hurricane Zone of the Florida Building Code. <br />DESCRIPTION: Timberline® Prestique® 40 <br />LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and <br />following statement: "Miami -Dade County Product Control Approved", wiless otherwise noted herein. <br />RENEWAL ofthis NOA shall be considered after a renewal application has been filed and there has been no <br />change in the applicable building code negatively aiT'ecting the performance of this product. <br />TERMINATION Of this NOA will occur after the expiration date or if there has been a revision or change in the <br />materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any <br />product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply <br />with any section of this NOA steal l be cause for termination and removal of NOA. <br />ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by <br />the expiration date may he displayed in advertising literature. If any portion of the NOA is displayed, then it shall <br />be clone in its entirety. <br />INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors <br />and shah be available for inspection at the job site at the request of the Building Official. <br />This renews NOA #07-0507.10 and consists of pages I through 4. <br />The submitted documentation was reviewed by Alex Tigera. <br />APPROVED <br />MIAMI <br />DADE <br />BUILDING CODE COMPLIANCE OFFICE. (BCCO) <br />PRODUCT CONTROL. DIVISION <br />NOTICE OF ACCEPTANCE (NOA) <br />ROOFING SYSTEM APPROVAL <br />Categor: <br />Roofing <br />Sub -Category: <br />07310 Asphalt Shingles <br />Materials <br />Dimensional <br />Deck Tvuc: <br />Wood <br />I. SCOPE <br />This renews GAF Timberline Prestique 40 as manufactured <br />by GAF Materials Corp described in <br />Section 2 <br />of this Notice of Acceptance. <br />2. PRODUCT DESCRIPTION <br />Product Dimensions <br />Test <br />Product Description <br />Specifications <br />Timberline Prestique 13t/,"x 393/B- <br />TAS 110 <br />Fiberglass reinforced heavy weight <br />asphalt roof <br />40 <br />shingle, with a laminate profile <br />3. EVIDENCE SUBMITTED: <br />Test Agency <br />Test Identifier <br />Test Name/Report <br />Date <br />Center for Applied Engineering <br />PA 100 <br />02/23/94 <br />Underwriters Laboratories, Inc. <br />ASTM 3462 <br />ASTM D3462 <br />09/13/06 <br />PRI Asphalt Technologies, Inc. <br />ASTM D3462 <br />GAF-102-02-02 <br />11/02/05 <br />Underwriters Laboratories, Inc. <br />PA 107 <br />Modifed ASTM D 3161 <br />04/13/94 <br />Center for Applied Engineering <br />ASTM D3462 <br />03/18/97 <br />PRI Asphalt Technologies, inc. <br />TAS 100 <br />6AF-045-02-01 <br />01 /13/04 <br />PRi Asphalt Technologies, inc. <br />GAF-102-02-01 <br />11/14/05 <br />Underwriters Laboratories, Inc <br />TAS 107 <br />04NK04273 <br />02/20/04 <br />Underwriters Laboratories, Inc <br />Modified ASTM D3161 OSCA42840 <br />11/11/05 <br />4. LIMITATIONS <br />4.1 Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials <br />Directory for fire ratings of this product. <br />4.2 Shall not be installed on roof mean heights in excess of 33 ft. <br />4.3 All products listed herein shall have a quality assurance audit in accordance with the Florida <br />Building Code and Rule 9B-72 of the Florida Administrative Code. <br />5. INSTALLATION <br />5.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115. <br />5.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 <br />5.3 The manufacturer shall provide clearly written application instructions. <br />5.4 Exposure and course layout shall be in comp lianec with Deta]I'A', attached. <br />5.5 Nailing shall be in compliance with Detail'B', attached. <br />6. LABELING <br />6.1 Shingles shall be labeled with the Miami -Dade Product Control Approved Seal or the wording <br />"Miami -Dade County Product Control Approved". <br />7. BUILDING PERMIT RF,QUIREMENTS <br />7.1 Application for building permit shall be accompanied by copies of the following: <br />7.1.1 This Notice of Acceptance. <br />7.1.2 Any other documents required by the Building Official or the applicable code in order <br />to properly evaluate the installation of this system. <br />8. MANUFACTURING PLANTS <br />8.1 Tampa, Fi, <br />8.2 Michigan City, IN <br />DETAIL A <br />134 <br />1„ <br />82 r <br />f <br />1 <br />DETAIL R <br />Front Side (Maximum Slope 12:12) <br />4 F- <br />6„ <br />LL <br />_ 1 <br />5-5 <br />-- <br />6 fasteners 72„ 712 „ <br />7 - <br />L <br />1/2" <br />f ..- <br />Front Side (Maximum Slope 21:12) <br />Tab Sealant <br />21, <br />L <br />Back Side <br />END OF THIS ACCEPTANCE <br />- Release <br />Tape <br />- Release <br />Tape <br />18" <br />3/8" <br />NOA No.:07-1120.14 <br />NOA No.:07-1120.14 <br />NOA No.:07-1120.14 <br />NOA No.:07-1120.14 <br />Expiration Date: 04/22/13 <br />Expiration Date: 04/22/13 <br />Expiration Date: 04/22/13 <br />Expiration Date: 04/22/13 <br />Approval Date: 05/o8/08 <br />M 1 . �. rr Approval Date: 015/08/08 <br />MIA•D,A MIDECOUN Approval Date: 05/08/08 <br />' "'' ' <br />MIAMI•DADEC uNrY Approval Date: 05/08/09 <br />"' • ' Page 4 4 <br />Page 2 of 4 <br />Page 3 of 4 <br />of <br />Page 1 of 4 <br />MIAMI-DADS COUNTY, FLORIDA <br />METRO-DADE FLAGLER BUILDING <br />140 WEST FLAGLF.R STREET, SUITE 1603 <br />MIAMI, FLORIDA 331_M-1563 <br />(305) 375-2901 FAX (305) 375 2908 <br />GAF Material Corporation <br />1361 Alps Road <br />Wayne, NJ 07470 <br />SCOPE: <br />This NOA is being issued under the applicable rules and regulations governing the use of construction <br />materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building <br />Code and Product Review Committee to be used in Miami Dade County and other areas where allowed <br />by the Authority Having Jurisdiction (AHJ). <br />This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product <br />Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) <br />reserve the right to have this product or material tested for quality assurance purposes. If this product or <br />material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing <br />and the AHJ may immediately revoke, modify, or suspend the use of such product or material within <br />their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade <br />County Product Control Division that this product or material fails to meet the requirements of the <br />applicable building code. <br />This product is approved as described herein, and has been designed to comply with the Florida Building <br />Code and the High Velocity Hurricane Zone of the Florida Building Code. <br />DESCRIPTION: GAF Deck -Armor Underlayment <br />LABELING: Each unit shall bear a permanent label with the manufacturer's narne or logo, city, state <br />and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted <br />herein. <br />RENEWAL of this NOA shall be considered after a renewal application has been tiled and there has <br />been no change in the applicable building code negatively affecting the performance of this product. <br />TERMINATION of this NOA will occur after the expiration date or if there has been a revision or <br />change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an <br />endorsement of any product, for sales, advertising or any other purposes shall automatically terminate <br />this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of <br />NOA. <br />ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and <br />followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is <br />displayed, then it shall be done in its entirety. <br />INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its <br />distributors and shall be available for inspection at the job site at the request of the Building Official. <br />This NOA consists of pages 1 through 4. <br />The submitted documentation was reviewed by <br />NOA No.: 06-0606.04 <br />Expiration Date: 10/12/11 <br />Approval Date. 10/12/06 <br />Page 1 of 4 <br />ROOFING ASSEMBLY APPROVAL APPROVED ASSEMBLIES: <br />Category Roofing Deck Type 1: Wood, Non -insulated <br />Sub -Category: Underlayment Deck Description: `y/32" or greater plywood or wood plank <br />Material: Polypropylene <br />System A(1): Leak Barrier is installed as per current NOA approval at vulnerable leak areas. <br />Deck -Armor Membrane is subsequently installed. Standard installation, no <br />TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: exposure to rain/snow prior to installation of the Surface Roofing Assembly <br />Product Dimensions Test Product <br />minimum slope: 4"on 12". <br />Specification Description Leak Barrier: Install Weather Watch@ or Stol mGuard@ leak barrier as per current NOA <br />Deck -Armor 54" x 222' rolls ASTM D 226 A UV -stabilized polypropylene breathable approval at all vulnerable leak areas, this incl odes but is not limited to all eaves, <br />Type H underlayment. To be used for roof deck valleys, rakes, skylights, and dormers. <br />protection as an underlayment in sloped roof Membrane: One or more plies of Deck -Armor underlayti nt membrane with a minimum 3" <br />assemblies. side lap and 6" end lap. Place th(, first course of membrane parallel to the eave. <br />Weather Watch 36" x 50' rolls ASTM D 1970 Granular Surfaced modified, Fiberglass Fasten side and end laps with approved nails and tin caps 6" o.c. and fasten middle <br />36" x 67' rolls reinforced, bituminous sheet material for as of the roll with approved nails and tin caps 1 o.c. in two staggered rows, in the <br />an underlayment in sloped roof assemblies. field of the roll. <br />Designed as an ice & rain shield Surfacing: Approved Roofing Assembly. <br />Storm Guard 36" x 66.7' rolls ASTM D 1970 Modified, fiberglass reinforced, bituminous <br />sheet material for as an underlayment in Deck Type 1: Wood, Non -insulated <br />sloped roof assemblies. Designed as an ice <br />& rain shield Deck Description: '9132" or greater plywood or wocxl plank <br />System A(2): Leak Barrier is installed as per cuurent NOA :-pproval at vulnerable leak areas. <br />Deck -Armor Membrane is subsequently instal led. Special installation, for <br />EVIDENCE SUBMITTED: exposure to rain/snow prior to installation of the Surface Roofing Assembly <br />minimum slope: 2"on 12". <br />Test Agency Test Identifier Test Name/Report Date Leak Barrier: Install Weather Watch® or StorinGuardo� leak harrier as per current NOA <br />approval at all vulnerable leak aj eas, this includes but is not limited to all eaves, <br />PRI Asphalt Technologies, Inc. GAF-025-02-01 ASTM D 1970 03/26/2002 valleys, rakes, skylights, and dot viers. <br />PRI Asphalt Technologies, Inc. GAF-026-02-01 ASTM D 1970 03/26/2002 Membrane: One or more plies of Deck -Armor underlayment membrane with a minimum 3" <br />side lap and 6" end lap. Place tho first course of membrane parallel to the cave. <br />PRI Asphalt Technologies, Inc. GAF-112-02-01 ASTM D 226 Type II 03/15/20!)6 Fasten side and end laps with approved nails :-nd tin caps 6" o.c. and fasten middle <br />of the roll with approved nails altd tin caps 121" o.c. in two staggered rows, in the <br />field of the roll. If roof is exposed to rain/snow, tape all end and side laps with <br />approved butyl adhesive based s,•am/cover tale or an approved waterproof cloth <br />duct tape (fallow the tape manulacturer's installation instructions). Always apply <br />tape over all fasteners at the censer of the roll or the laps to help prevent rain or <br />snow from entering at the fasten •rs. <br />Surfacing: Approved Roofing Assembly. <br />CRA NOA No.: 06-0606.04AV%NOA No.: 06-0606.04 <br />Y Expiration Date: 10/12/11 ry Expiration Date: 10/12/11 <br />Approval Date: 10/12/06 Eta Approval Date: 10/12/06 <br />Page 2 of 4qW Page 3 of 4 <br />LIMITATIONS: <br />1. Fire classification is not part of this acceptance. <br />2. Deck-Arnior shall not he used as roof tile underlayment. <br />3 This acceptance is for prepared roofing applications. Minimum deck requirements shall be in <br />eotnpliane a with applicable building code. Deck -Armor shall be installed in strict compliance with <br />applicable Building Codes and Manufacturers' specifications and guidelines. <br />4. Deck-Arnlor shall he applied to a smooth, clean and dry surface with deck free of irregularities. <br />5. Deck -Armor shall not be applied over an existing roof membrane. <br />6 Deck Armor Mate shell not be left exposed as a temporary roof for longer than 14 days of <br />application. <br />7. All nails in the deck shall be carefully checked for protruding heads. Re -faster, any loose decking <br />panels. Sweep the deck thoroughly to remove any dust and debris prior to application. <br />8. Deck Armor may he used with any approved roof covering; Notice of Acceptance listing Deck -Armor <br />as a component part of an assembly in the Notice of Acceptance. if Deck -Armor is not li,ted, a <br />request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product <br />Control Department for approval provided that appropriate documentation is provided to detail <br />compatibility of the products. wind uplift resistance, and fire testing results. <br />9. When applying the membrane in the valley, start at the low point and work to the high point, rolling <br />the membrane from the center outward in both directions. <br />10. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current <br />Product Control Notice of Acceptance and applicable Building Code. <br />11. All memhranes shall bear the imprint or identifiable marking of the manufacturer's name or logo, or <br />following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade logo. <br />END OF THIS ACCEPTANCE <br />NOA No.: 06-0606.04 <br />Expiration Date: 10/12/11 <br />Approval Date: 10/12/06 <br />Page 4 of 4 <br />ALL RIMS RESERVE <br />CORDA & ASSOCIATES ARCHffECrS®2008 COPYRIOH <br />o <br />� <br />t o <br />�a¢ <br />8 <br />M� <br />� <br />W <br />�T, <br />H <br />W <br />o <br />N <br />h+i <br />CD <br />o <br />I <br />►--i <br />00 <br />I <br />00 <br />00 <br />u7 <br />wrn <br />w <br />J <br />o. <br />CIDz <br />to <br />z <br />U <br />Cw <br />z <br />w <br />� <br />a <br />�- <br />rN <br />O <br />DATE. 5/30/08 <br />SCALE: AS N OTE I , <br />JOB NO.: 27013 <br />SHEET: <br />A2111 <br />i <br />01 22 _SHEET <br />0 <br />