AR HANDLER SECT ON DETAIL <br />N.T.S. DIAGRAMATIC ONLY. REFERS TO AHU-2. <br />1. AIR HANDLER, WITH VIBRATION ISOLATION <br />PADS. REFER TO NOTE FIVE. <br />2. SUPPLY DUCT WITH 3-PIECE OR RADIUS <br />ELBOW. TRANSITION FROM UNIT DISCHARGE <br />OPENING AFTER START-COLLAR/HEATER <br />TO PLAN LISTED DUCT SIZE AND CONTINUE. <br />3. RETURN DUCT/FILTER BANK. PROVIDE 2", 30% FILTERS <br />IN UNIT UPON START UP. IF AHU IS RUN DURING <br />CONSTRUCTION, REPLACE FILTERS WEEKLY. <br />PROVIDE NEW SET OF FILTERS AT FINAL INSPECTION. <br />4. COORDINATE DUCT WITH ROOF STRUCTURE PRIOR TO INSTALL. <br />5. VECO MODEL 300N, OR EQUAL, CORK AND NEOPRENE <br />VIBRATION PAD. MINIMUM 4"x4" UNDER EACH CORNER. <br />6. CEILING AREA. <br />7. SCH. 40 PVC CONDENSATE LINE TO HUB DRAIN. <br />INSULATE ENTIRE LENGTH WITH MINIMUM 1/2" WALL <br />ARMAFLEX INSULATION. PROVIDE SAFETY SWITCH <br />ON DRAIN LINE IN LIEU OF SECONDARY PAN. <br />8. FLOOR SLAB, TYPICAL. <br />9. ROOF TRUSS SYSTEM WITH 6/12 PITCH. <br />INSTALL DUCT TIGHT TO STRUCTURE. <br />10. REFRIGERANT COPPER TO CU. COORDINATE LOCATION <br />AND ROUTING WITH GEN. CONTRACTOR PRIOR TO INSTALL. <br />N.T.S. DIAGRAMATIC ONLY. REFERS TO AHU-1. <br />1. AIR HANDLER, WITH WALL MOUNTING <br />BRACKETS OR FLOOR STAND. <br />2. SUPPLY DUCT WITH 3-PIECE ELBOW, <br />TRANSITION FROM UNIT DISCHARGE <br />OPENING AFTER START -COLLAR TO PLAN <br />DUCT SIZE AND CONTINUE. <br />3. RETURN DUCT FROM BENEATH AHU. STAND <br />SHALL BE FABRICATED TO ALLOW FULL <br />SIZE OF UNIT RETURN TO BE EXTENDED <br />FROM BENEATH AND UNRESTRICTED <br />ACCESS FROM THE SIDES, TYPICAL. TURN <br />TO HORIZONTAL WITH 3-PIECE ELBOW. <br />4. FILTER RACK WITH 1" DISP. FILTER. <br />5. DUCT TRANSITION. USE 3-PIECE ELBOW <br />FOR TURN TO HORIZONTAL, TYPICAL. <br />6. CEILING AREA. <br />7. SCHEDULE 40 PVC DRAIN LINE TO EXTERIOR <br />OR HUB DRAIN. INSULATE ENTIRE LENGTH <br />WITH MIN 3/16" WALL ARMAFLEX INSULATION. <br />PROVIDE SAFETY SWITCH ON DRAIN LINE. <br />8. FLOOR SLAB, TYPICAL. <br />9. ROOF SYSTEM WITH R-19 INSULATION. <br />COORDINATE WITH ARCHITECTURAL. <br />10. REFRIGERANT COPPER TO CU. COORDINATE LOCATION <br />WITH GEN. CONTRACTOR PRIOR TO INSTALL. <br />ca rm <br />SUPPORT <br />OELING FAN DETAIL <br />POT TO sc" <br />CONDENSING' <br />UNIT (CU). <br />16 GAUGE I <br />GALVANIZE[ <br />STRAP W/ <br />SCREWS T( <br />CONCRETE <br />No. 14 BY <br />TAPCON, W <br />WASHER, T <br />MECHANICAL GENERAL NOTES: <br />1. DUCT SIZES ARE CLEAR, INSIDE DIMENSIONS. VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO <br />FABRICATION OR INSTALLATION. ALL DUCTWORK SHALL BE TYPE 800 FIBERGLASS <br />EQUAL TO JOHNS-MANVILLE. DUCT SHALL BE 1-1/2" THICK WITH AN "R" VALUE OF 6. <br />EXHAUST DUCT SHALL BE GALVANIZED SHEET STEEL WITH ALL JOINTS SEALED WITH MASTIC. <br />ROUND EXHAUST DUCT SHALL BE ALUMINUM "THERMOFIN" OR SINGLE WALL ROUND SHEET METAL. <br />EXHAUST DUCTS DO NOT NEED TO BE INSULATED UNLESS REQUIRED BY LOCAL ORDINANCE. <br />ALL DUCT SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA REQUIREMENTS. <br />2. ALL BRANCH CONNECTIONS SHALL BE CLASS ONE FLEXIBLE DUCT WITH A MANUAL VOLUME <br />DAMPER INSTALLED IN THE COLLAR AT THE MAIN TRUNK FOR BALANCING PURPOSES. <br />I ALL SYSTEMS 2000 CFM AND OVER SHALL HAVE A SMOKE DETECTOR INSTALLED IN THE SUPPLY <br />DUCTWORK. DETECTOR SHALL BE 24 VOLT POWERED FROM THE UNIT'S LOW VOLTAGE PANEL UNLESS <br />THERE IS A FIRE ALARM SYSTEM. THEN THE DETECTOR SHALL BE 120 VOLTS, SUPPLIED BY THE FIRE <br />ALARM CONTRACTOR, INSTALLED BY THE HVAC CONTRACTOR AND WIRED BY FIRE ALARM. PROVIDE <br />L.E.D. AND HORN ALARM STATIONS IN AREA MONITORED DURING BUSINESS HOURS, PER CODE. <br />4. ALL ROOF AND WALL PENETRATIONS SHALL BE SEALED BY THEIR RESPECTIVE TRADES. <br />5. CONTRACTOR SHALL PROVIDE SIX (6) COPIES OF ALL SUBMITTAL DATA FOR APPROVAL. <br />6. DEVIATION FROM MATERIALS, METHODS, OR PROCEDURES SET FORTH HERIN MUST BE APPROVED, <br />IN WRITING, BY ENGINEER PRIOR TO SUBMISSION OF BID, ORDER, FABRICATION OR INSTALLATION. <br />7. ANY AND ALL QUESTIONS AS TO THE INTENT OF, OR PROCEDURES SET FORTH IN THESE DRAWINGS <br />MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO SUBMISSION OF A BID. LACK OF <br />KNOWLEDGE OR UNDERSTANDING OF PLANS SHALL NOT JUSTIFY ANY CLAIMS OR EXTRA COMPENSATION. <br />8. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE LAWS, CODES, AND ORDINANCES. <br />9. THE HVAC CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCT, & DIFFUSER LOCATIONS AND <br />CLEARANCES WITH ALL OTHER TRADES ON PROJECT, IN PRECONSTRUCTION MEETING, PRIOR TO ANY <br />ORDER, FABRICATION, OR INSTALLATION. <br />10. THERMOSTATS SHALL BE MANUFACTURER 7-DAY PROGRAMMABLE MODEL WITH SUB -BASE. ALL DUAL - <br />COMPRESSOR OR UNLOADING SYSTEMS SHALL HAVE TWO STAGE HEAT/COOL THERMOSTATS. <br />MOUNT THERMOSTATS AT 5-6" ABOVE FINISHED FLOOR, TYPICAL. <br />11. SUPPLY DUCTWORK SHALL BE CONSTRUCTED, FABRICATED, AND INSTALLED IN ACCORDANCE <br />WITH SMACNA REQUIREMENTS FOR A 1" POSITIVE STATIC PRESSURE CLASSIFICATION. <br />12. RETURN AND EXHAUST DUCTWORK SHALL BE CONSTRUCTED, FABRICATED, AND INSTALLED <br />IN ACCORDANCE WITH SMACNA REQUIREMENTS FOR A 1" NEGATIVE STATIC PRESSURE. <br />13. ALL EXHAUST FAN DISCHARGES AND PLUMBING VENTS SHALL BE A MINIMUM OF 10'-0" FROM <br />FRESH -AIR INTAKES. COORDINATE WITH PLUMBING PLANS PRIOR TO INSTALLATION. <br />14. THE MECHANICAL CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT TEST AND BALANCE <br />AGENCY TO TEST AND BALANCE ALL HVAC SYSTEMS ON THIS PROJECT. THE TEST AND BALANCE REPORT <br />SHALL BE SUBMITTED TO THE MECHANICAL ENGINEER FOR REVIEW AND ACCEPTANCE. <br />THE TEST AND BALANCE TEST REPORT SHALL BE SUBMITTED SEVEN (7) WORKING DAYS <br />PRIOR TO SUBSTANTIAL COMPLETION. THE TEST AND BALANCE CONTRACTOR SHALL INCLUDE THE <br />PROVISION FOR ADJUSTMENTS REQUESTED BY THE MECHANICAL ENGINEER -OF -RECORD AND RESUBMITTAL <br />OF THE CORRECTED TEST AND BALANCE REPORT. THE AIR DEVICES IN EACH SPACE SHALL BE BALANCED <br />TO WITHIN 10% OF THE AIRFLOW QUANTITIES INDICATED ON THE MECHANICAL DRAWINGS. <br />TESTING AGENCY SHALL BE AABC OR NEBB CERTIFIED. <br />15, REFRIGERANT COPPER LIQUID AND SUCTION LINES SHALL BE TYPE 'L' SOFT DRAWN AND SIZED PER <br />MANUFACTURER'S RECOMMENDATIONS. INSULATE SUCTION LINE WITH 3/4" THICK "ARMAFLEX" INSULATION. <br />TAPE ALL JOINTS TIGHT TOGETHER. SYSTEMS OVER 5 TONS SHALL HAVE TYPE "L" HARD DRAWN <br />REFRIGERANT LIQUID AND SUCTION LINES. REFRIGERANT PIPING CONFIGURATION SHALL ASSURE <br />THAT THE REFRIGERANT OIL SATISFACTORILY RETURNS TO THE COMPRESSOR. REFRIGERANT PIPING RUN <br />BELOW GRADE SHALL BE RUN IN 6" PVC PIPIE WITH LONG RADIUS SWEEPS AT ALL TURNS. PROVIDE SIGHT <br />GLASS WITH REMOVABLE CORE FOR EACH LIQUID LINE. <br />16. EXTEND CONDENSATE DRAIN LINES FROM AIR HANDLER4S) TO PLUMBER PROVIDED HUB DRAIN EXTENDED TO <br />EXTERIOR AND GRASS/LANDSCAPE AREA. PROVIDE 24' x24%24" DEEP DRYWELL IF NO APPROVED <br />SURFACES EXIST ON WHICH TO DRAIN. INSULATE ENTIRE LENGTH FROM AHU'S TO HUB DRAIN WITH 3/16" <br />WALL ARMAFLEX OR OTHER TYPE INSULATION. PROVIDE FLOAT SWITCH/SAFETY SWITCH AT AHU. <br />SUPPLY AIR <br />'PANDUIT' OR 'ZIP' <br />STRAP OVER INNER <br />CORE OF FLEX. FLEXIBLE DUCT <br />THERMAL INSULATION <br />OVER THE TOP SUSPENDED <br />EXHAUST DUCT OF THE DIFFUSER. CEILING <br />SIZE PER PLAN. (AS APPLICABLE <br />SCREENED <br />WALL CAP OR CEILING DIFFUSER <br />LOUVER. <br />EXTERIOR WALL CEUNG DFFUE:3ER0_' DETAL <br />J. NO SCALE. FOR DIAGRAMATIC PURPOSES ONLY. <br />NOTES: <br />�N161i a` <br />NOT TO SCALE <br />- DETAIL IS PROVIDED FOR FLORIDA 135 MPH WIND <br />TIE -DOWN COMPLIANCE. <br />- STRAP SHALL BE SCREWED INTO FRAME OF EQUIPMENT <br />AND SECURED E WITH No. 14 X 3" TAPCON <br />INTO CONRETE PAD OR OTHER STRUCTURALLY <br />SECURED BASE. <br />- TAPE INNER COIL OF FLEX TO THE DIFFUSER <br />COLLAR. TAPE COMPLETELY AROUND TO ASSURE <br />AN AIR TIGHT SEAL OR USE 'ZIP' STRAP <br />AROUND INNER CORE OF FLEX. USE METAL BAND <br />CLAMP WHERE REQUIRED BY LOCAL AUTHORITY. <br />- PULL FLEX INSULATION AND OUTER COVER DOWN <br />OVER GRILLE COLLAR AND SECURE TO GRILLE <br />WITH WITH TAPE ONLY. DO NOT USE STRAP OR <br />OTHER METHOD WHICH WILL COMPRESS INSULATION. <br />- STRETCH FLEX TIGHT BETWEEN DUCT AND DIFFUSER <br />TO AVOID KINKS. SUPPORT EVERY FOUR FEET <br />WITH 2" STEEL STRAP OR OTHER APPROVED HANGER. <br />HANGER SUPPORTS: INSULATED ROUND FLEXIBLE <br />8'O.C. = 0-35" DUCTS DUCT (MAX. 15'-0" LONG) <br />6'O.C. = 36-59" DUCTS SUPPORT BOTH ROUND METAL & <br />FLEX DUCT EVERY FOUR FEET <br />. WITH 2" 24 GA. STEEL STRAP. - <br />SUPPLY DUCT A <br />SADDLE: 22 GAGE <br />CEILING <br />TAB COLLAR WITH <br />MANUAL DAMPER. <br />INSULATION <br />RIGID ROUND METAL <br />BRANCH DUCT <br />AS APPLICABLE. <br />CEILING DIFFUSER <br />CEUNG D FUSEG� RMNOMT DETAL <br />NOT TO SCALE <br />- HANGER SUPPORTS SHALL BE AS NOTED ABOVE FOR DUCT WIDTHS UP <br />TO 24" AND WITH TRAPEZE HANGERS FOR DUCTS 25" AND ABOVE. <br />ME�=,mANCAL SCHEDULEE"I'), DETALE-3" � NOTES <br />SCALE: NONE <br />AR HANDLER SCHEDULE <br />MARK <br />AHU-1 <br />AHU-2 <br />MANUFACTURER <br />CARRIER <br />CARRIER <br />MODEL NUMBER <br />FV4BNF006 <br />40RMOO8-B501 <br />TOTAL COOLING <br />58,000 <br />92,500 <br />SENSIBLE COOLING <br />39,125 <br />69,000 <br />SUPPLY CFM <br />2000 <br />3000 <br />OUTSIDE AIR CFM <br />100 <br />175 <br />EXTERNAL S.P. IN W.G. <br />.6" <br />.75" <br />TOTAL S.P. IN W.G. <br />1.15" <br />1.25" <br />FAN R.P.M. <br />VARIABLE SPEED <br />1725 <br />MOTOR HORSEPOWER <br />3/4 <br />2.4 <br />FAN MOTOR F.L.A. <br />5.6 <br />5.2 <br />ENTERING AIR TEMPERATURE <br />76 67 <br />76 67 <br />LEAVING AIR TEMPERATURE <br />55.E 54.8 <br />55.4 54.6 <br />ELECTRIC HEAT KW STEPS <br />11.25 - 1 - 208V. F. <br />10 - 1 - 208V. 1P. <br />FILTER TYPE <br />30% PLEATED <br />30% PLEATED <br />FILTER THICKNESS <br />1" <br />2" <br />ELECTRICAL VOLTS PHASE <br />208 230 V., 1 PH. <br />208 230 V., 3 PH. <br />WEIGHT <br />207 <br />385 <br />LOCATION <br />MECH. ROOM <br />MECH. ROOM <br />NOTES <br />1,2,3,5,6 <br />1,2,3,5,E <br />L';ONDENSANG UNTSCHEDULE- <br />MARK <br />CU-1 <br />CU-2 <br />MANUFACTURER <br />CARRIER <br />CARRIER <br />MODEL NUMBER <br />24ABR360A0030 <br />38ARZ008 <br />CAPACITY IN TONS <br />5.0 <br />7.5 <br />E.E.R. S.E.E.R. <br />13.0 <br />12.7 <br />COIL FINS PER INCH <br />25 <br />17 <br />COIL AREA <br />30.18 <br />29.2 <br />COMPRESSORS R.L.A. <br />1 - 17.3 <br />1 - 25.6 <br />CIRCUITS <br />8 <br />1 <br />CONDENSER FAN - N0. H.P. F.L.A. <br />1 - 1 4 - 1.2 <br />2 - 1 4 - 1.5 3.1 <br />ELECRICAL VOLTS PHASE <br />208 230V. 3 PH. <br />208 230V. 3 PH. <br />MIN. CIRCUIT AMPS. <br />22.8 <br />39.8 <br />MAX FUSE M.O.C.P. <br />35 <br />60 <br />WEIGHT <br />206 <br />383 <br />LOCATION <br />WEST EQUIP. PAD <br />WEST EQUIP. PAD <br />NOTES <br />1,2,4 <br />1,2,4,7 <br />NOTES: 1. HVAC CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL ELECTRICAL <br />COSTS WHICH MAY RESULT FROM SUBSTITUTED EQUIPMENT. <br />2. UNIT SHALL HAVE A SINGLE POINT ELECTRICAL CONNECTION. <br />3. PROVIDE TXV'S AND LOW AND HIGH PRESSURE SWITCHES. <br />4. PROVIDE LIQUID LINE FILTER -DRYERS. <br />5. PROVIDE FACTORY 7-DAY PROGRAMMABLE THERMOSTAT. <br />6. INSTALL FILTERS IN AIR HANDLER PRIOR TO START UP AND PROVIDE <br />NEW SET OF FILTERS AT COMPLETION OF CONSTRUCTION. <br />FAN SC HEDULE <br />MARK <br />MANUFACTURER <br />MODEL NUMBER <br />AREA <br />TYPE <br />C.F.M. <br />R.P.M. <br />SONES <br />S.P. <br />WATTSH.P. <br />VOLTS <br />PHASE <br />NOTES <br />EF-1 <br />COOK-GEMINI <br />GC-120 <br />JANITOR <br />CELNG EXHAUST <br />50 <br />1200 <br />2.2 <br />.25 <br />35 <br />-- <br />120V. <br />1P. <br />1-3,5 <br />EF-2,3 <br />COOK-GEMINI <br />GC-120 <br />RESTROOM <br />CELNG EXHAUST <br />75 <br />1200 <br />1.7 <br />.125 <br />35 <br />-- <br />120V, <br />1P. <br />1-4 <br />NOTE: ALTERNATE EQUIVALENT MANUFACTURERS ARE ACCEPTABLE. <br />NOTES: <br />1. PROVIDE BACKDRAFT DAMPER. <br />2. FACTORY PLUG DISCONNECT. <br />3. GALVANIZED STEEL SCREENED WALL CAP. <br />4. FAN SHALL BE CONTROLLED BY ROOM LIGHT SWITCH. <br />5. FAN SHALL RUN CONTINUOUSLY. <br />A �� DOISTG�OoUIT 00N "SC H E D U LE <br />MARK <br />MANUFACTURER <br />MODEL NUMBER <br />SIZE <br />CFM <br />NECK <br />LOCATION <br />MATERIAL <br />NOTES: <br />A <br />TITUS <br />TMS <br />24 X 24 <br />SEE PLAN <br />SEE PLAN <br />CEILING <br />STEEL <br />1,2 <br />B <br />TITUS <br />350FL <br />24 X 24 <br />SEE PLAN <br />24 X 24 <br />CEILING <br />STEEL <br />1,2,3 <br />C <br />TITUS <br />250 <br />10 X 6 <br />SEE PLAN <br />10 X 6 <br />CEILING <br />STEEL <br />1,2,4,5 <br />D <br />TITUS <br />250 <br />IS X 4 <br />1 SEE PLAN <br />18 X 4 <br />1 CEILING <br />1 STEEL <br />1,2,4,5 <br />A /400/10"RND <br />SIZE THROW CFM 1 NECK/FLEX CONNECTION SIZE <br />NOTES: <br />1. PROVIDE MANUAL VOLUME DAMPER AT MAIN TRUNK FOR BALANCING. <br />2. DIFFUSER FINISH SHALL BE OFF-WHITE. <br />3. PATTERN SHALL BE 35 DEGREE FIXED BLADE, 3/4" SPACING. <br />4. PROVIDE PRE-FAB R-6 INSULATED GRILLE BOX WITH TAB COLLAR. <br />5. GRILLE FACE SHALL BE ADJUSTABLE CURVED BLADE. NO STAMPED GRILLES ACCEPTED. <br />L E � E N FD--) <br />CEILING SUPPLY DIFFUSER <br />CEILING RETURN <br />CEILING EXHAUST FAN <br />THERMOSTAT <br />SMOKE DETECTOR <br />VOLUME DAMPER <br />RIGID DUCT <br />FLEXIBLE DUCT <br />FLOW DIRECTION-® <br />ALL RIGHTS RESERVED <br />CM k ASSOCIATES ARCHITECTS 0 20M COPYRIGHT <br />REVISIONS <br />Zv <br />OZ <br />04 <br />Joao <br />a, <br />N w t L4 Cn Fi <br />QJ <br />> �o <br />Z <br />]> <br />�53r3mN <br />Z Z <br />a }k� a•• <br />i g+ ` Lo) o <br />QOrT'�^o <br />0 <br />U E <br />co N <br />w o <br />�' <br />IQ <br />CV _ <br />a 00 <br />N <br />LLJ <br />� cV CO <br />0 <br />I <br />w Z <br />Lei 00 <br />_j <br />M� <br />O <br />M--1 <br />Q <br />E-I <br />O <br />N <br />w <br />� o <br />o <br />rn <br />I <br />ca <br />rn <br />I <br />00 <br />N <br />r� <br />�� <br />W� <br />g <br />Q <br />O w <br />w <br />Qi = <br />m <br />w <br />z <br />J <br />w <br />3 <br />O 0 <br />DATE: <br />8-19-08 <br />SCALE: 1 /4"=1 ' -0" <br />JOB NO.: <br />08016 <br />SHEET: <br />M 2 <br />1 OF 2 <br />SHEETS <br />