Laserfiche WebLink
I, <br />IA <br />PLUMBNG RXTURE SCHEDULE <br />LABEL <br />FIXTURE <br />W V CW HW <br />DESCRIPTIONS <br />P-1 <br />WATER CLOSET <br />3" 2" 1/2" - <br />AMERICAN STANDARD 2377.100 WHITE ELONGATED <br />HANDICAPPED <br />HANDICAPPED 1.6 GALLON FLUSH WATER CLOSET <br />OLSONITE #95 WHITE SEAT, CP STOP AND SUPPLY. <br />P-2 <br />HANDICAPPED <br />11i2" 2" 1/2" 1i2" <br />AMERICAN STANDARD #0355.012 WALL HUNG <br />LAVATORY <br />LAV, , ZURN Z-831A4-GH FAUCET, <br />20 GAUGE CP P-TRAP LESS CLEANOUT, <br />CR1912-A CP STOPS AND SUPPLIES. <br />P-3 <br />ELECTRIC <br />11/2" 2" 1i2" - <br />ELKAY EZSTL-8C COOLER, STANDARD COLOR, <br />WATER COOLER <br />1-1i4" 20 GAUGE CP P-TRAP LESS C.O., STOP AND <br />DUAL -LEVEL <br />SUPPLY. MOUNT LOWER NOZZLE AT H.C. HEIGHT. <br />P-4 <br />SINK -SINGLE <br />11/2" 2" 1/2" 1i2" <br />ELKAY PSR-1918, 19"x18"0" DEEP, 20 <br />COMPARTMENT <br />GAUGE -TYPE 302 SELF -RIMMING SINK WITH <br />LK-2445 FAUCET AND LK-99 DRAIN. 18 GAUGE <br />P-TRAP, CHROME STOPS AND SUPPLIES. <br />P-5 <br />MOP BASIN <br />3" 2" 1i2" 1/2" <br />FIAT MSB-2424 MOP BASIN WITH 830-AA SERVICE <br />FAUCET W/ BRACKET & HANGER, 1453BB STAINLESS <br />STEEL STRAINER, VAC. BREAKER & HOSE THREADED SPOUT. <br />FD <br />FLOOR DRAIN <br />3" 2" 1/2" - <br />ZURN MODEL Z-415-P WITH 6" DIAMETER <br />TYPE 'B' NICKEL BRONZE STRAINER. RIM TO <br />BE FLUSH WITH FINISHED FLOOR AND <br />LEVEL . PROVIDE TRAP PRIMER CONNECTION. <br />EWH <br />ELECTRIC <br />- - 3/4" 3/4" <br />A.O. SMITH DEL-20, 20 GALLON WATER <br />WATER HEATER <br />HEATER. 2.0 K.W. 0 208 VOLT, 1 PHASE. <br />U.L. LISTED AND ASHRAE 90-A APPROVED. <br />I 4„ <br />GCO <br />I <br />-2 P-2 i 1„ 1 <br />1" CW RISER WITH 1 <br />3 I EXTEND AND CONNECT TO SITE <br />3„LA i o I SOV AT 48" A.F.F. <br />" 2 P44 - I SANITARY SEWER CONNECTION. <br />C AU LT I M F--, I I i COORDINATE WITH CIVIL DRAWINGS <br />1 P-5 <br />- <br />--- -, ---- -----, --- -----t --- -----r --- _ I I TO BID OR INSTALLATION. <br />I i t I I I I I I I I I I I I <br />1 I I I I I I I I I I I I I I I I r I I I I I <br />I I I I <br />JAN _- - <br />--- J- ---_ l --- I ; --r--- I -, 1' CW B.G. <br />B R 11t , CW B.G. <br />-- --- - --- - L - - I 1 <br />- - ---- - <br />------------------------------- .--------------- _ - <br />PjALL VENTS THRU ROOF ---� - P-3 <br />SHALL BE A MIN. OF 10-0________________________ 1 1 CW FROM METER <br />FROM ALL O.A. INTAKES. <br />TURN FLASHING DOWN AND BACKFLOW <br />INTO PIPE (MINIMUM 2") <br />VENT STACK (V.T.R.) 1 <br />4 LB. LEAD FLASHING I O <br />RISER CLAMP. ATTACH j <br />TO BUILDING STRUCTURE. I <br />ROOFING SYSTEM. REFER <br />TO ARCHITECTURAL DRAWINGS t <br />AND/OR FIELD COORDINATE. t <br />t <br />�- ---- -�- PROVIDE 3" HUB DRAIN FOR AHU <br />CONDENSATE. EXTEND TO EXTERIOR <br />AND TERMINATE AT DRYWELL, <br />MINIMUM 12" FROM BUILDING, IN <br />LANDSCAPE AREA. COORDINATE WITH HVAC <br />CONTRACTOR PRIOR TO INSTALATION. <br />----------------------------------- - - - -- <br />- - ------------------- <br />----- - ----- - - - - - <br />- - <br />1 - - -- - �- - - - - - <br />,Y,�II L .__..._� <br />P-1� 4D P-1 r>!\� <br />\\/V CASH I I 3" 3" <br />TELLERS FD 4" FD 4" CONFERENCE 4" <br />-=-=--=--=-----=- =- =-=-=-=-=--=-- - --=-- - -------- -- -1417 <br />2„ �- - - - -- <br />T R F_ <br />1 <br />t r2 EACH, <br />3" HW & CW. <br />t <br />I I I <br />I I I I I <br />r-- <br />I <br />I <br />I <br />r -- <br />I <br />I <br />I I <br />WAIT <br />REFER TO WATER <br />PART -PLAN FOR <br />DOMESTIC WATER <br />I <br />I <br />LAYOUT, THIS AREA. <br />I <br />I <br />I <br />PLYWOOD DECKING <br />WOOD TRUSS OR OTHER BUILDINGI <br />STRUCTURAL SYSTEM. REFER TO1 <br />STRUCTURAL DRAWINGS FOR <br />FURTHER INFORMATION. <br />I L <br />-�I I <br />I I <br />VENT THRU ROOF DETAIL <br />� I I <br />N.T.S. <br />WENEF�ALWO 960T�S'� <br />I ' <br />LOBBY <br />I <br />F CUSTOMER SERVICE <br />1 I I <br />1. PLUMBING CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMISSION OF A BID t <br />TO VERIFY THAT ALL UTILITIES ARE AS SHOWN. REPORT ALL DISCREPANCIES <br />TO THE ARCHITECT PRIOR TO BID. I - -- <br />2. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 P.V.C. WITH DRAINAGE t <br />PATTERN FITTINGS. I O JJJ J <br />3. ALL WATER PIPING SHALL BE TYPE L COPPER WITH SOLDERED JOINTS. PROVIDE 1 __._______ ____ _ _.. <br />WATER HAMMER ARRESTORS EQUAL TO JAY R. SMITH AT EACH FIXTURE GROUP. L - -, <br />4. SLOPE WASTE LINES 3" AND OVER, 1/8" PER FOOT. LINES SMALLER THAN 3" SHALL 1 <br />SLOPED AT 1/4" PER FOOT. <br />5. INSULATE ALL DOMESTIC HOT WATER PIPING WITH 1/2" WALL "ARMAFLEX", OR EQUAL. <br />6. PROVIDE ISOLATION VALVES AT ALL FIXTURES. VALVES SHALL BE CHROME FINISH. <br />7. PROVIDE BLOCKING SUPPORT OR WALL CARRIERS AT ALL WALL -HUNG FIXTURES. 1 <br />8. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES, LAWS AND 1 <br />ORDINANCES, BE THEY LOCAL, STATE OR NATIONAL. j - - <br />9. PLUMBING CONTRACTOR SHALL COORDINATE ALL VENTS THRU ROOF WITH 1 <br />ROOFING CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. <br />10. DEVIATION FROM MATERIALS, METHODS, OR PROCEDURES SET FORTH HEREIN <br />MUST BE APPROVED, IN WRITING, BY ENGINEER PRIOR TO BID SUBMISSION. 1 <br />11. PIPE HANGERS SHAL BE SPLIT RING TYPE, GALVANIZED, WITH THREADED 1 <br />ROD SUPPORT FROM STRUCTURE ABOVE, EQUAL TO GRINNELL. DISTANCE _ - <br />BETWEEN SUPPORTS SHALL BE SUFFICIENT TO PREVENT PIPE SAGGING. 1 <br />12. ROOF FLASHINGS SHALL BE FURNISHED FOR ALL VENTS THROUGH ROOF. WORK R M _ <br />FLASHING SHALL BE 4 LB./SQ. FT. LEAD OR 16 OZ./SQ. FT. COPPER, AND SHALL _ <br />EXTEND UP THE VENT AND TURN DOWN INSIDE THE VENT A MINIMUM OF 2" BELOW 1 FUTURE O F F <br />THE TOP OF THE PIPE. FLASHINGS SHALL BE FURNISHED BY PLUMBING /j <br />- <br />SUBCONTRACTOR AND INSTALLED BY THE ROOFING SUBCONTRACTOR. -- r - <br />13. TESTING OF THE PLUMBING SYSTEM SHALL BE PERFORMED BY THE PLUMBING l ILI - <br />SUBCONTRACTOR AND WITNESSED BY THE BUILDING DEPARTMENT INSPECTOR. 1 <br />POTABLE HOT AND COLD WATER SUPPLY PIPING SHALL BEHYDROSTATICALLY 1 <br />TESTED AT 125 PSIG FOR 24 HOURS. SOIL, WASTE AND VENT PIPING SHALL BE <br />FILLED WITH WATER TO THE TOP OF THE SYSTEM FOR A PERIOD OF 24 HOURS. 1 <br />14. CLEANOUTS SHALL BE PROVIDED PER PLAN OR AS REQUIRED TO PROVIDE _ <br />A COMPLETE SERVICEABLE SYSTEM. CLEANOUTS SHALL BE SAME SIZE AS PIPE. _ <br />FLOOR CLEANOUTS SHALL BE EQUAL TO ZURN Z-1400-KC WITH BRONZE TOP. <br />WALL WALL -HUNG <br />SHALL BE EQUAL TO ZURN Z-1411 WITH STAINLESS STEEL COVER. OFFICE M G R LENDER BRANCH M G R <br />15. ALL WALL -HUNG HANDICAPPED FIXTURES SHALL BE CAPABLE OF 1 <br />SUPPORTING A 254LB. VERTICAL LOAD. 1 <br />16. INSULATE TRAY, TRAP AND APPLICABLE HOT WATER PIPING BELOW ALL VESTIBULE <br />HANDICAPPED LAVATORIES WITH TRUEBRO "LAVGUARD", OR OTHER <br />APPROVED INSULATION SYSTEM. - - - -- - <br />17. WATER PIPING BELOW GRADE SHALL BE TYPE 'Y' COPPER IN VINYL SLEEVE. <br />- <br />----- - - - - - - - - - - - - - --- __--- - - - -- ---- ----------------------------------------------- ---- <br />TR. ------------------------------, <br />1--------------------------------------- <br />v. 1 1 <br />101 I <br />3 <br />I <br />2' �' v <br />3%kb I <br />2 <br />,,V I ,, k <br />I <br />IFS <br />I <br />I <br />I <br />I C5010 <br />I 3>> <br />P.5 <br />P' <br />2 I <br />P' <br />11h <br />SANFARY ROGER <br />SCALE: NONE <br />CATER DL.))EMAND S"U`rL1EDULE_ <br />FIXTURE <br />CW FIXTURE <br />UNITS EACH <br />HW FIXTURE <br />UNITS EACH <br />FIXTURE UNIT <br />TOTAL EACH <br />QUANTITY <br />EACH <br />FIXTURE UNIT <br />TOTAL - ALL <br />WATER CLOSET - TANK <br />5.0 <br />-0- <br />5.0 <br />2 <br />10 <br />LAVATORY <br />1.4 <br />1.4 <br />2.0 <br />2 <br />4 <br />WATER COOLER <br />.25 <br />-0- <br />.25 <br />1 <br />.25 <br />SINK - DOUBLE COMPARTMENT <br />1.0 1 <br />1.0 1 <br />1.4 <br />1 <br />1.4 <br />MOP BASIN <br />2.25 <br />2.25 <br />3.0 <br />1 <br />3 <br />TOTAL FIXTURE UNITS <br />18.65 <br />TOTAL GPM <br />19.1 <br />REQUIRED WATER LINE SIZE: <br />1" <br />I I <br />1 P-1 o O P_1 I <br />3i4" DROP. <br />I i SPLIT 1/2 <br />I <br />( l " I <br />1 . 0 I�l *I <br />I TO EACH - 3�4_' 1„ I <br />L-_____________------------------------________________J <br />SCALE: 1/4" = 1'-O" <br />i <br />1/2" EACH. <br />TO P-5. <br />P-2EE, _ P-2 I '2 <br />EWH, ABOVE <br />CEILING. <br />3/ „ I <br />3i4" W TO EWH, 11/2, <br />HW TO SYSTEM. _ <br />UUP-3 <br />L- - - - - - - - - - - - - - - - - - - - - - - - - - - -J <br />WATER PART -PLAN <br />SCALE: 1/4" = 1'-O" <br />1/2" EACH. <br />I <br />PREVENTER, BY OTHERS. <br />I <br />L - - - - - <br />�� I <br />I <br />I <br />I <br />I <br />I <br />I <br />' I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />LECUENDD <br />COLD WATER <br />HOT WATER <br />SANITARY <br />VENT <br />FLOOR CLEANOUT <br />GRADE CLEANOUT <br />WALL CLEANOUT <br />FCO <br />GCO <br />WCO <br />I <br />ALL MGM RESERVED I <br />do CORDA ASSOCIATES ARCHITECTS D 2008 COPYRIGHT <br />REVISIONS <br />L] <br />U' ? <br />N <br />9 n <br />W E9 <br />N N' <br />5 M N co <br />p2�$z~S59 <br />o <br />J <br />� ``00 <br />Q :3 <br />V Nt.mN <br />�aa z <br />ZZ= <br />Iv <br />d <br />g'N� o <br />NOCL <br />Wo <br />oorn+� <br />�.Q_r� <br />04 <br />Lr�Jp� <br />�Q <br />N <br />Q 00 <br />N <br />W <br />� CV 00 <br />0 <br />w z � <br />Lq 00 <br />Q <br />E <br />W <br />MH <br />~ <br />H w <br />W <br />o <br />N <br />� o <br />E� o <br />ran) <br />I <br />00 <br />cn <br />I <br />00 <br />04 <br />N <br />co <br />r7 <br />w a <br />E-4 <br />O w <br />U� W <br />�Q <br />o� m <br />w <br />z <br />�J <br />�Uj <br />w <br />3 <br />00 <br />DATE: <br />8-19-08 <br />SCALE: 1 /4"=1'-0" <br />JOB NO.. <br />08016 <br />SHEET: <br />P 1 <br />OF 1 <br />SHEETS <br />