I,
<br />IA
<br />PLUMBNG RXTURE SCHEDULE
<br />LABEL
<br />FIXTURE
<br />W V CW HW
<br />DESCRIPTIONS
<br />P-1
<br />WATER CLOSET
<br />3" 2" 1/2" -
<br />AMERICAN STANDARD 2377.100 WHITE ELONGATED
<br />HANDICAPPED
<br />HANDICAPPED 1.6 GALLON FLUSH WATER CLOSET
<br />OLSONITE #95 WHITE SEAT, CP STOP AND SUPPLY.
<br />P-2
<br />HANDICAPPED
<br />11i2" 2" 1/2" 1i2"
<br />AMERICAN STANDARD #0355.012 WALL HUNG
<br />LAVATORY
<br />LAV, , ZURN Z-831A4-GH FAUCET,
<br />20 GAUGE CP P-TRAP LESS CLEANOUT,
<br />CR1912-A CP STOPS AND SUPPLIES.
<br />P-3
<br />ELECTRIC
<br />11/2" 2" 1i2" -
<br />ELKAY EZSTL-8C COOLER, STANDARD COLOR,
<br />WATER COOLER
<br />1-1i4" 20 GAUGE CP P-TRAP LESS C.O., STOP AND
<br />DUAL -LEVEL
<br />SUPPLY. MOUNT LOWER NOZZLE AT H.C. HEIGHT.
<br />P-4
<br />SINK -SINGLE
<br />11/2" 2" 1/2" 1i2"
<br />ELKAY PSR-1918, 19"x18"0" DEEP, 20
<br />COMPARTMENT
<br />GAUGE -TYPE 302 SELF -RIMMING SINK WITH
<br />LK-2445 FAUCET AND LK-99 DRAIN. 18 GAUGE
<br />P-TRAP, CHROME STOPS AND SUPPLIES.
<br />P-5
<br />MOP BASIN
<br />3" 2" 1i2" 1/2"
<br />FIAT MSB-2424 MOP BASIN WITH 830-AA SERVICE
<br />FAUCET W/ BRACKET & HANGER, 1453BB STAINLESS
<br />STEEL STRAINER, VAC. BREAKER & HOSE THREADED SPOUT.
<br />FD
<br />FLOOR DRAIN
<br />3" 2" 1/2" -
<br />ZURN MODEL Z-415-P WITH 6" DIAMETER
<br />TYPE 'B' NICKEL BRONZE STRAINER. RIM TO
<br />BE FLUSH WITH FINISHED FLOOR AND
<br />LEVEL . PROVIDE TRAP PRIMER CONNECTION.
<br />EWH
<br />ELECTRIC
<br />- - 3/4" 3/4"
<br />A.O. SMITH DEL-20, 20 GALLON WATER
<br />WATER HEATER
<br />HEATER. 2.0 K.W. 0 208 VOLT, 1 PHASE.
<br />U.L. LISTED AND ASHRAE 90-A APPROVED.
<br />I 4„
<br />GCO
<br />I
<br />-2 P-2 i 1„ 1
<br />1" CW RISER WITH 1
<br />3 I EXTEND AND CONNECT TO SITE
<br />3„LA i o I SOV AT 48" A.F.F.
<br />" 2 P44 - I SANITARY SEWER CONNECTION.
<br />C AU LT I M F--, I I i COORDINATE WITH CIVIL DRAWINGS
<br />1 P-5
<br />-
<br />--- -, ---- -----, --- -----t --- -----r --- _ I I TO BID OR INSTALLATION.
<br />I i t I I I I I I I I I I I I
<br />1 I I I I I I I I I I I I I I I I r I I I I I
<br />I I I I
<br />JAN _- -
<br />--- J- ---_ l --- I ; --r--- I -, 1' CW B.G.
<br />B R 11t , CW B.G.
<br />-- --- - --- - L - - I 1
<br />- - ---- -
<br />------------------------------- .--------------- _ -
<br />PjALL VENTS THRU ROOF ---� - P-3
<br />SHALL BE A MIN. OF 10-0________________________ 1 1 CW FROM METER
<br />FROM ALL O.A. INTAKES.
<br />TURN FLASHING DOWN AND BACKFLOW
<br />INTO PIPE (MINIMUM 2")
<br />VENT STACK (V.T.R.) 1
<br />4 LB. LEAD FLASHING I O
<br />RISER CLAMP. ATTACH j
<br />TO BUILDING STRUCTURE. I
<br />ROOFING SYSTEM. REFER
<br />TO ARCHITECTURAL DRAWINGS t
<br />AND/OR FIELD COORDINATE. t
<br />t
<br />�- ---- -�- PROVIDE 3" HUB DRAIN FOR AHU
<br />CONDENSATE. EXTEND TO EXTERIOR
<br />AND TERMINATE AT DRYWELL,
<br />MINIMUM 12" FROM BUILDING, IN
<br />LANDSCAPE AREA. COORDINATE WITH HVAC
<br />CONTRACTOR PRIOR TO INSTALATION.
<br />----------------------------------- - - - --
<br />- - -------------------
<br />----- - ----- - - - - -
<br />- -
<br />1 - - -- - �- - - - - -
<br />,Y,�II L .__..._�
<br />P-1� 4D P-1 r>!\�
<br />\\/V CASH I I 3" 3"
<br />TELLERS FD 4" FD 4" CONFERENCE 4"
<br />-=-=--=--=-----=- =- =-=-=-=-=--=-- - --=-- - -------- -- -1417
<br />2„ �- - - - --
<br />T R F_
<br />1
<br />t r2 EACH,
<br />3" HW & CW.
<br />t
<br />I I I
<br />I I I I I
<br />r--
<br />I
<br />I
<br />I
<br />r --
<br />I
<br />I
<br />I I
<br />WAIT
<br />REFER TO WATER
<br />PART -PLAN FOR
<br />DOMESTIC WATER
<br />I
<br />I
<br />LAYOUT, THIS AREA.
<br />I
<br />I
<br />I
<br />PLYWOOD DECKING
<br />WOOD TRUSS OR OTHER BUILDINGI
<br />STRUCTURAL SYSTEM. REFER TO1
<br />STRUCTURAL DRAWINGS FOR
<br />FURTHER INFORMATION.
<br />I L
<br />-�I I
<br />I I
<br />VENT THRU ROOF DETAIL
<br />� I I
<br />N.T.S.
<br />WENEF�ALWO 960T�S'�
<br />I '
<br />LOBBY
<br />I
<br />F CUSTOMER SERVICE
<br />1 I I
<br />1. PLUMBING CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMISSION OF A BID t
<br />TO VERIFY THAT ALL UTILITIES ARE AS SHOWN. REPORT ALL DISCREPANCIES
<br />TO THE ARCHITECT PRIOR TO BID. I - --
<br />2. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 P.V.C. WITH DRAINAGE t
<br />PATTERN FITTINGS. I O JJJ J
<br />3. ALL WATER PIPING SHALL BE TYPE L COPPER WITH SOLDERED JOINTS. PROVIDE 1 __._______ ____ _ _..
<br />WATER HAMMER ARRESTORS EQUAL TO JAY R. SMITH AT EACH FIXTURE GROUP. L - -,
<br />4. SLOPE WASTE LINES 3" AND OVER, 1/8" PER FOOT. LINES SMALLER THAN 3" SHALL 1
<br />SLOPED AT 1/4" PER FOOT.
<br />5. INSULATE ALL DOMESTIC HOT WATER PIPING WITH 1/2" WALL "ARMAFLEX", OR EQUAL.
<br />6. PROVIDE ISOLATION VALVES AT ALL FIXTURES. VALVES SHALL BE CHROME FINISH.
<br />7. PROVIDE BLOCKING SUPPORT OR WALL CARRIERS AT ALL WALL -HUNG FIXTURES. 1
<br />8. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES, LAWS AND 1
<br />ORDINANCES, BE THEY LOCAL, STATE OR NATIONAL. j - -
<br />9. PLUMBING CONTRACTOR SHALL COORDINATE ALL VENTS THRU ROOF WITH 1
<br />ROOFING CONTRACTOR PRIOR TO COMMENCEMENT OF WORK.
<br />10. DEVIATION FROM MATERIALS, METHODS, OR PROCEDURES SET FORTH HEREIN
<br />MUST BE APPROVED, IN WRITING, BY ENGINEER PRIOR TO BID SUBMISSION. 1
<br />11. PIPE HANGERS SHAL BE SPLIT RING TYPE, GALVANIZED, WITH THREADED 1
<br />ROD SUPPORT FROM STRUCTURE ABOVE, EQUAL TO GRINNELL. DISTANCE _ -
<br />BETWEEN SUPPORTS SHALL BE SUFFICIENT TO PREVENT PIPE SAGGING. 1
<br />12. ROOF FLASHINGS SHALL BE FURNISHED FOR ALL VENTS THROUGH ROOF. WORK R M _
<br />FLASHING SHALL BE 4 LB./SQ. FT. LEAD OR 16 OZ./SQ. FT. COPPER, AND SHALL _
<br />EXTEND UP THE VENT AND TURN DOWN INSIDE THE VENT A MINIMUM OF 2" BELOW 1 FUTURE O F F
<br />THE TOP OF THE PIPE. FLASHINGS SHALL BE FURNISHED BY PLUMBING /j
<br />-
<br />SUBCONTRACTOR AND INSTALLED BY THE ROOFING SUBCONTRACTOR. -- r -
<br />13. TESTING OF THE PLUMBING SYSTEM SHALL BE PERFORMED BY THE PLUMBING l ILI -
<br />SUBCONTRACTOR AND WITNESSED BY THE BUILDING DEPARTMENT INSPECTOR. 1
<br />POTABLE HOT AND COLD WATER SUPPLY PIPING SHALL BEHYDROSTATICALLY 1
<br />TESTED AT 125 PSIG FOR 24 HOURS. SOIL, WASTE AND VENT PIPING SHALL BE
<br />FILLED WITH WATER TO THE TOP OF THE SYSTEM FOR A PERIOD OF 24 HOURS. 1
<br />14. CLEANOUTS SHALL BE PROVIDED PER PLAN OR AS REQUIRED TO PROVIDE _
<br />A COMPLETE SERVICEABLE SYSTEM. CLEANOUTS SHALL BE SAME SIZE AS PIPE. _
<br />FLOOR CLEANOUTS SHALL BE EQUAL TO ZURN Z-1400-KC WITH BRONZE TOP.
<br />WALL WALL -HUNG
<br />SHALL BE EQUAL TO ZURN Z-1411 WITH STAINLESS STEEL COVER. OFFICE M G R LENDER BRANCH M G R
<br />15. ALL WALL -HUNG HANDICAPPED FIXTURES SHALL BE CAPABLE OF 1
<br />SUPPORTING A 254LB. VERTICAL LOAD. 1
<br />16. INSULATE TRAY, TRAP AND APPLICABLE HOT WATER PIPING BELOW ALL VESTIBULE
<br />HANDICAPPED LAVATORIES WITH TRUEBRO "LAVGUARD", OR OTHER
<br />APPROVED INSULATION SYSTEM. - - - -- -
<br />17. WATER PIPING BELOW GRADE SHALL BE TYPE 'Y' COPPER IN VINYL SLEEVE.
<br />-
<br />----- - - - - - - - - - - - - - --- __--- - - - -- ---- ----------------------------------------------- ----
<br />TR. ------------------------------,
<br />1---------------------------------------
<br />v. 1 1
<br />101 I
<br />3
<br />I
<br />2' �' v
<br />3%kb I
<br />2
<br />,,V I ,, k
<br />I
<br />IFS
<br />I
<br />I
<br />I
<br />I C5010
<br />I 3>>
<br />P.5
<br />P'
<br />2 I
<br />P'
<br />11h
<br />SANFARY ROGER
<br />SCALE: NONE
<br />CATER DL.))EMAND S"U`rL1EDULE_
<br />FIXTURE
<br />CW FIXTURE
<br />UNITS EACH
<br />HW FIXTURE
<br />UNITS EACH
<br />FIXTURE UNIT
<br />TOTAL EACH
<br />QUANTITY
<br />EACH
<br />FIXTURE UNIT
<br />TOTAL - ALL
<br />WATER CLOSET - TANK
<br />5.0
<br />-0-
<br />5.0
<br />2
<br />10
<br />LAVATORY
<br />1.4
<br />1.4
<br />2.0
<br />2
<br />4
<br />WATER COOLER
<br />.25
<br />-0-
<br />.25
<br />1
<br />.25
<br />SINK - DOUBLE COMPARTMENT
<br />1.0 1
<br />1.0 1
<br />1.4
<br />1
<br />1.4
<br />MOP BASIN
<br />2.25
<br />2.25
<br />3.0
<br />1
<br />3
<br />TOTAL FIXTURE UNITS
<br />18.65
<br />TOTAL GPM
<br />19.1
<br />REQUIRED WATER LINE SIZE:
<br />1"
<br />I I
<br />1 P-1 o O P_1 I
<br />3i4" DROP.
<br />I i SPLIT 1/2
<br />I
<br />( l " I
<br />1 . 0 I�l *I
<br />I TO EACH - 3�4_' 1„ I
<br />L-_____________------------------------________________J
<br />SCALE: 1/4" = 1'-O"
<br />i
<br />1/2" EACH.
<br />TO P-5.
<br />P-2EE, _ P-2 I '2
<br />EWH, ABOVE
<br />CEILING.
<br />3/ „ I
<br />3i4" W TO EWH, 11/2,
<br />HW TO SYSTEM. _
<br />UUP-3
<br />L- - - - - - - - - - - - - - - - - - - - - - - - - - - -J
<br />WATER PART -PLAN
<br />SCALE: 1/4" = 1'-O"
<br />1/2" EACH.
<br />I
<br />PREVENTER, BY OTHERS.
<br />I
<br />L - - - - -
<br />�� I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />' I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />-------
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />1
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />i
<br />LECUENDD
<br />COLD WATER
<br />HOT WATER
<br />SANITARY
<br />VENT
<br />FLOOR CLEANOUT
<br />GRADE CLEANOUT
<br />WALL CLEANOUT
<br />FCO
<br />GCO
<br />WCO
<br />I
<br />ALL MGM RESERVED I
<br />do CORDA ASSOCIATES ARCHITECTS D 2008 COPYRIGHT
<br />REVISIONS
<br />L]
<br />U' ?
<br />N
<br />9 n
<br />W E9
<br />N N'
<br />5 M N co
<br />p2�$z~S59
<br />o
<br />J
<br />� ``00
<br />Q :3
<br />V Nt.mN
<br />�aa z
<br />ZZ=
<br />Iv
<br />d
<br />g'N� o
<br />NOCL
<br />Wo
<br />oorn+�
<br />�.Q_r�
<br />04
<br />Lr�Jp�
<br />�Q
<br />N
<br />Q 00
<br />N
<br />W
<br />� CV 00
<br />0
<br />w z �
<br />Lq 00
<br />Q
<br />E
<br />W
<br />MH
<br />~
<br />H w
<br />W
<br />o
<br />N
<br />� o
<br />E� o
<br />ran)
<br />I
<br />00
<br />cn
<br />I
<br />00
<br />04
<br />N
<br />co
<br />r7
<br />w a
<br />E-4
<br />O w
<br />U� W
<br />�Q
<br />o� m
<br />w
<br />z
<br />�J
<br />�Uj
<br />w
<br />3
<br />00
<br />DATE:
<br />8-19-08
<br />SCALE: 1 /4"=1'-0"
<br />JOB NO..
<br />08016
<br />SHEET:
<br />P 1
<br />OF 1
<br />SHEETS
<br />
|