I
<br />1
<br />2"V
<br />m
<br />�3"VTR
<br />� � I
<br />13"V
<br />I� '�,2"V I 'I
<br />��
<br />� � I r-2"V
<br />2„ V I r I EXPOSED
<br />n
<br />j CONNECT TO EXISTING I I I I I \V
<br />4" SANITARY SCS I I2 "
<br />V
<br />�000TG I 113"V I i
<br />" 2"V I I I 1
<br />4"
<br />FCO LAV-HC I K3"
<br />O I2"V3" I12"V
<br />2"DCSop I
<br />NOT TO 5CA1_E
<br />DISCONNECT SWITCH-��
<br />BY ELECTRICAL
<br />SUBCONTRACTOR
<br />I
<br />VACUUM BREAKER: LTJI
<br />36 WATTS OR EQUAL
<br />CHECKVALVE i
<br />GATE VALVE
<br />i
<br />COLD WATER--0Q-�-t
<br />i
<br />i
<br />i
<br />i
<br />i
<br />SERVICE DRAIN VALVE
<br />ASME T&P RELIEF
<br />VALVE: DWV COPPER
<br />FULL SIZE ROUTED
<br />TO DRAIN PAN
<br />WATER
<br />HEATER
<br />DRAIN: I
<br />COPPER DWV
<br />ROUTED TO °
<br />FLOOR DRAIN
<br />WATER HEATER D ETA I L
<br />THERMAL EXPANSION TANK:
<br />AMTROL "THERM-X-TROL" ST-12
<br />HEAT TRAP
<br />HOT WATER
<br />DIELECTRIC UNIONS
<br />SAFETY PAN: 24
<br />GAGE GALVANIZED
<br />SHEET METAL, 1-1/2"
<br />DEEP, SOLDERED
<br />LIQUIDTIGHT
<br />PLUMBING GENERAL NOTES
<br />1. ALL WORK SHALL COMPLY WITH NATIONAL, STATE AND LOCAL CODES. THIS SHALL INCLUDE THE
<br />2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA PLUMBING CODE, WITH LOCAL AMENDMENTS.
<br />2. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING. INSTALLATION TO INCLUDE ALL PLUMBING FOR
<br />COMPLETE SYSTEMS DEPICTED ON THE PLANS.
<br />3. COORDINATE WITH OTHER TRADES TO PREVENT CONFLICTS WITH HVAC DUCTS, ELECTRICAL LIGHTING
<br />AND STRUCTURAL ELEMENTS.
<br />4. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL FIXTURES SHOWN ON THE PLUMBING
<br />FIXTURE SCHEDULE. VERIFY MOUNTING HEIGHT AND CONNECTION SIZES OF ALL PLUMBING
<br />FIXTURES PRIOR TO INSTALLATION.
<br />5. ALL WORK, BOTH MATERIAL AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR
<br />FROM ACCEPTANCE BY THE OWNER.
<br />WATER PIPING
<br />1. THE WATER PIPING SHALL BE TYPE "K" COPPER BELOW GRADE, WITH VINYL SLEEVE FOR
<br />ANTI -CORROSION, AND TYPE "L" ABOVE GROUND WITH WROUGHT COPPER FITTINGS (ASTM
<br />816.22-89) AND SOLDER JOINTS.
<br />2. THE WATER SERVICE TO THE BUILDING IS EXISTING TO REMAIN.
<br />3. THE MAIN BACKFLOW PREVENTER IS EXISTING TO REMAIN.
<br />4. THE SITE WATER METER IS EXISTING TO REMAIN.
<br />5. SUPPORT ALL PIPING WITH PIPE HANGERS EQUAL TO GRINNEL.
<br />6. PROVIDE EACH FIXTURE WITH A SHUT-OFF SUPPLY STOPS. EXPOSED STOPS AND SUPPLY PIPING
<br />SHALL BE CHROME PLATED, WITH CHROME ESCUTCHEON PLATE AND SET SCREW. STOPS SHALL BE 8"
<br />AFF FOR WATER CLOSETS AND 16" AFF FOR LAVATORIES.
<br />7. PROVIDE UNIONS FOR ALL CONNECTIONS TO SERVICEABLE EQUIPMENT. UNIONS SHALL BE
<br />DIELECTRIC WHERE DISSIMILAR METALS ARE CONNECTED.
<br />8. INSULATE ALL HOT WATER PIPING WITH j" ARMAFLEX OR J" FIBERGLASS EQUAL TO MANVILLE
<br />MICRO-LOK AP-T. VAPOR SEAL ALL BUTT JOINTS.
<br />9. PROVIDE WATER HAMMER ARRESTORS, EQUAL TO JR SMITH 5000 SERIES, IN ACCORDANCE WITH PDI
<br />STANDARD WH-201. FIELD FABRICATED SHOCK ABSORBERS ARE NOT ACCEPTABLE.
<br />10. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE.
<br />11. STERILIZE ALL WATER PIPING IN ACCORDANCE WITH HEALTH DEPARTMENT REGULATIONS.
<br />12. TEST ALL WATER PIPING AT 100 PSIG FOR SIX HOURS OR AS REQUIRED BY THE JURISDICTION.
<br />13. PROVIDE SHUT OFF VALVES FOR ALL EXTERIOR HOSE BIBS AND WALL HYDRANTS.
<br />14. PROVIDE SERVICE VALVES AT EACH BRANCH SUPPLY LINE, AS DEPICTED ON THE PLAN. ALL
<br />VALVES, CHECK STOPS, ETC. SHALL BE RATED FOR 125 LB SERVICE. VALVES SHALL BE BALL OR
<br />GATE TYPE, GLOBE VALVES ARE NOT ACCEPTABLE. VALVES SHALL BE INSTALLED IN AN
<br />ACCESSIBLE LOCATION FOR SERVICING AND OPERATION.
<br />SANITARY, WASTE AND VENT PIPING
<br />1. SANITARY WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC DWV (ASTM-2665) WITH SOLVENT
<br />WELDED JOINTS.
<br />2. SLOPE OF SANITARY AND WASTE PIPING SHALL BE UNIFORM, WITH A MINIMUM OF j" PER FOOT FOR
<br />2" AND A MINIMUM OF J" PER FOOT FOR LARGER PIPING.
<br />3. EXPOSED WASTE DRAINS IN RESTROOMS SHALL BE CHROME PLATED BRASS TUBING WITH MATCHING
<br />CHROME ESCUTCHEON PLATE.
<br />4. PROVIDE INTERIOR AND EXTERIOR CLEANOUTS AS REQUIRED BY CODE.
<br />5. FURNISH 4 LB LEAD OR 8 OZ COPPER VENT FLASHING FOR INSTALLATION BY THE GENERAL
<br />CONTRACTOR FOR ALL VENTS THROUGH ROOF. VERIFY TYPE OF ROOFING PRIOR TO INSTALLATION.
<br />6. TEST SANITARY, WASTE AND VENT PIPING USING A 10 FOOT WATER COLUMN FOR 2 HOURS OR AS
<br />REQUIRED BY THE JURISDICTION.
<br />BATHROOM FLOOR DRAIN TRAP PRIMER DETAIL
<br />PLUMBING FIXTURE SCHEDULE
<br />ROUGH -IN
<br />MARK
<br />FIXTURE, MODEL #, DESCRIPTION
<br />WASTE
<br />VENT
<br />CW
<br />HW
<br />WC-HC
<br />WATER CLOSET, HANDICAPPED
<br />3"
<br />2"
<br />1/2"
<br />-
<br />KOHLER K-3519
<br />WHITE ELONGATED, PRESSURE ASSISTED 1.0 GALLON FLUSH, TANK TYPE
<br />WATER CLOSET, OLSONITE #95 WHITE SEAT, CP STOP AND SUPPLY.
<br />LAV-HC
<br />LAVATORY, WALL HUNG, HANDICAPPED
<br />1-1/2"
<br />2„
<br />1/2"
<br />1/2„
<br />KOHLER K-2032
<br />WITH K-11075-4 GOOSENECK FAUCET AND ADA COMPLIANT LEVER HANDLES,
<br />1-1/4" CP P-TRAP, CP STOPS, SUPPLIES. WITH TRU-BRO INSULATION KIT.
<br />IMB
<br />ICE MAKER BOX
<br />1/2"
<br />-
<br />RECESSED ICE MAKER BOX EQUIVALENT TO WATER TITE MODEL W9000 WITH
<br />WALL BOX FRAME AND COVER AND 1/2" SWEAT CONNECTION VALVE.
<br />EWC-SL
<br />ELECTRIC WATER COOLER, DUAL LEVEL, HANDICAPPED
<br />1-1/2-
<br />2-
<br />1/2"
<br />-
<br />ELKAY EZSTL8C COOLER, STANDARD COLOR, 1-1/2" 20 GAUGE CP P-TRAP,
<br />LESS CO, STOP AND SUPPLIES. MOUNT LOWER BOWL NOZZLE AT 30" A.F.F
<br />FOR ADA.
<br />EWH-40
<br />ELECTRIC WATER HEATER
<br />3/4"
<br />3/4"
<br />A.O. SMITH DEN-40
<br />R-16 FOAM INSULATED, GLASS -LINED 40 GALLON TANK, THREE (3) YEAR
<br />WARRANTY WATER HEATER. 45" HIGH x 20" DIAMETER, 3.0 kW ® 208 VOLT,
<br />1 PHASE ELECTRIC HEATER. U.L. LISTED AND ASHRAE 90.1-1999
<br />APPROVED. WITH GRUNDFOS RECIRC PUMP AND AQUA-STAT/TIMER.
<br />LS
<br />LAB SINK
<br />1-1/2„
<br />2„
<br />1/2„
<br />1/2„
<br />ELKAY PSR1918-3
<br />19"08 % 7" DEEP, 20 GAUGE TYPE 304 SELF -RIMMING SINK WITH LK2445
<br />FAUCET AND LK99 DRAIN. 18 GAUGE P-TRAP, CP STOPS AND SUPPLIES.
<br />DCS
<br />DOUBLE COMPARTMENT SINK,
<br />1-1/2„
<br />2„
<br />1/2„
<br />1/2„
<br />ELKAY LRAD3322-60-3
<br />33"x22"x6" DEEP, 18 GAUGE TYPE 304 SELF RIMMING DOUBLE COMPARTMENT
<br />SINK WITH LK4100 FAUCET, LK35 STRAINERS, CP P-TRAPS WITH CLEANOUTS,
<br />STOPS AND SUPPLIES.
<br />FD
<br />FLOOR DRAIN
<br />3"
<br />2"
<br />1/2"
<br />-
<br />ZURN Z415-6B-P
<br />6" FLOOR DRAIN WITH TRAP -PRIMER CONNECTION AND TYPE "B" STRAINER.
<br />TP
<br />TRAP PRIMER
<br />1/2"
<br />-
<br />J.R. SMITH 2698
<br />WATER SAVER TYPE, CP BRONZE PIPING AND ESCUTCHEON PLATES. ROUTE
<br />PRIMER PIPING IN WALL TO FLOOR DRAIN.
<br />WCO
<br />WALL CLEANOUT
<br />SEE
<br />-
<br />-
<br />ZURN Z1441
<br />PLAN
<br />D.C.C.I. BODY WITH STAINLESS STEEL ACCESS COVER AND SECURING SCREW.
<br />FCO
<br />FLOOR CLEANOUT
<br />SEE
<br />-
<br />-
<br />ZURN Z1400
<br />PLAN
<br />D.C.C.I. BODY ADJUSTABLE TO FINISHED FLOOR.
<br />COTG
<br />CLEANOUT TO GRADE
<br />SEE
<br />-
<br />ZURN Z1400-HD
<br />PLAN
<br />D.C.C.I. BODY ADJUSTABLE TO FINISHED GRADE WITH HEAVY DUTY TOP.
<br />SET IN 24"x24"x6" CONCRETE PAD.
<br />NOTES:
<br />1. APROVED MANUFACTURERS OF FIXTURES ARE AMERICAN STANDARD, ELJER AND KOHLER.
<br />2. APPROVED MANUFACTURERS OF DRAINS AND CLEANOUTS ARE J.R. SMITH, ANCON, WADE AND ZURN.
<br />3. ALL SUPPLIES SHALL BE PROVIDED WITH CP BRASS ANGLE STOPS, EASTMAN, BRASSCRAFT
<br />OR EQUAL, PROVIDED AT ALL FIXTURES.
<br />4. ALL EXPOSED TRAPS AND WASTE ARMS SHALL BE CP BRASS, MCGUIRE OR EQUAL.
<br />PLUMBING
<br />LEGEND
<br />SANITARY SEWER (SAN)
<br />VENT (V)-------5
<br />COLD WATER (CW)
<br />-
<br />HOT WATER (HW)
<br />SHUT-OFF VALVE
<br />SITE POINT OF CONNECTION
<br />0
<br />W
<br />0
<br />U)
<br />Q
<br />0
<br />co
<br />Uj
<br />co
<br />0
<br />w
<br />Z
<br />0
<br />a
<br />0
<br />Z
<br />w
<br />a
<br />w
<br />m
<br />J
<br />J
<br />Q
<br />WiedFiCk
<br />Architecture, I nc.
<br />WIEDRICK ARCHITECTURE INC.
<br />AA26001799
<br />2020 HEIDELBERG AVE.
<br />DUNEDIN, FLORIDA, 34698
<br />727.736.8627
<br />STATE OF FLORIDA
<br />REGISTERED ARCHITECT:
<br />MATTHEW WIEDRICK
<br />AR94577
<br />``X\111111/!
<br />\AN M A A-
<br />v
<br />No.54827
<br />�:� p'•:c<ORIOP•
<br />STATE OF
<br />0 a�
<br />®d NALeN�'\ ®®�
<br />O
<br />N
<br />d'
<br />Q)
<br />co
<br />Q
<br />J
<br />-i
<br />ILL
<br />4-a
<br />U)
<br />_l
<br />�-
<br />J
<br />LU
<br />�-
<br />�--�
<br />co
<br />=
<br /><Z
<br />LIJ
<br />PROJECT ADDRESS:
<br />38444 5TH AVE.
<br />ZEPHYRHILLS, FL 33542
<br />C:I IFNT-
<br />FLORIDA PHARMACY
<br />SOLUTIONS, INC.
<br />13933 17TH ST. SUITE 300
<br />DADE CITY, FL 33525
<br />DATE I DESCRIPTION I
<br />PLUMBING NOTES AND DETAILS
<br />SEEDS Engineering, Inc.
<br />27730 Santa Anita Blvd. p: ( 813) 902-2515
<br />Wesley Chapel, FL 33544 f: ( 813) 902-2516
<br />jmakar@seedseng.com
<br />Florida Certificate of Authorization No. 28278
<br />MJW
<br />PROJECT #: 14022
<br />P201