My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38444 5th Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38444 5th Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:52:12 PM
Creation date
2/19/2025 1:58:38 PM
Metadata
Fields
Template:
Building Plans
Street #
38444
Location
5th Ave
Contractor
Cross Construction
Building Plans - Permit #
15890
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC GENERAL NOTES <br />1. ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES. THIS INCLUDES <br />THE 2010 FLORIDA BUILDING CODE AND THE 2010 FLORIDA MECHANICAL CODE, WITH LOCAL <br />AMENDMENTS, THE APPLICABLE NFPA CODES AND THE FLORIDA ENERGY CODE. <br />2. ALL ELECTRICAL EQUIPMENT SHALL BE UL CLASSIFIED OR LISTED. <br />3. DEFINITIONS: "FURNISH" SHALL MEAN TO PURCHASE AND LOCATE AN ITEM ON THE JOBSITE. <br />"INSTALL" SHALL MEAN TO PHYSICALLY INSTALL AN ITEM AND CONNECT IT TO ALL REQUIRED <br />SERVICES TO MAKE THE ITEM FULLY FUNCTIONAL. "PROVIDE" SHALL MEAN TO BOTH FURNISH AND <br />INSTALL THE ITEM. <br />4. TEST AND BALANCE SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR ON APPROVED FORMS <br />USED BY AABC OR NEBB. THE MECHANICAL CONTRACTOR SHALL HAVE ALL SYSTEMS FULLY <br />INSTALLED AND OPERATIONAL WITH CLEAN FILTERS INSTALLED PRIOR TO TEST AND BALANCE. <br />AIR CONDITIONING EQUIPMENT <br />1. THE AIR CONDITIONING EQUIPMENT SHALL BE STRAIGHT COOL, WITH ELECTRIC HEAT. <br />2. ALL EQUIPMENT SHALL MEET THE MINIMUM EER REQUIREMENTS OF THE FLORIDA ENERGY CODE. <br />3. TRANE IS THE BASIS OF DESIGN WITH AMERICAN STANDARD, CARRIER AND YORK AS APPROVED <br />ALTERNATES. IF AN ALTERNATE IS SUBMITTED, THE CONTRACTOR SHALL MAKE ALL NECESSARY <br />CHANGES TO THE ELECTRICAL, STRUCTURAL AND DUCTWORK TO ACCOMMODATE THE SUBSTITUTION. <br />4. SUBMITTALS SHALL BE REVIEWED BY THE ELECTRICAL SUBCONTRACTOR FOR IMPACT TO THE <br />ELECTRICAL SYSTEMS, PRIOR TO ORDERING THE EQUIPMENT. <br />5. ALL AIR CONDITIONING EQUIPMENT SHALL INCLUDE A MINIMUM 1 YEAR UNIT WARRANTY AND AN <br />EXTENDED 4 YEAR COMPRESSOR WARRANTY. <br />6. PROVIDE 1" CONDENSATE PIPING AS SHOWN ON THE PLAN AND DETAIL. THE CONTRACTOR SHALL <br />EXTEND THE CONDENSATE PIPING TO THE EXTERIOR TO SPILL TO SITE STORM RETENTION. <br />7. THE AIR CONDITIONING UNITS SHALL BE OPERATED DURING CONSTRUCTION WITH THROW AWAY <br />FILTERS. FILTERS SHALL BE CHANGED DURING CONSTRUCTION IF THEY BECOME RESTRICTIVE OF <br />AIR FLOW FOR NORMAL OPERATION. PROVIDE NEW FILTERS JUST PRIOR TO TEST AND BALANCE. <br />8. UNITS SHALL BE CLEANED AND ALL SCRATCHES PAINTED OVER WITH FACTORY PAINT TO MATCH <br />UNIT. ALL CONDENSER COILS SHALL BE COMBED OUT AND ALL PANELS AND SCREWS SHALL BE <br />INSTALLED AT THE COMPLETION OF THE PROJECT. <br />DUCTWORK <br />1. SUPPLY AND RETURN DUCT SHALL BE 1-1/2" DUCT BOARD, INSTALLED IN ACCORDANCE WITH <br />SMACNA. SEE DETAIL FOR INSTALLATION AND HANGING INSTRUCTIONS. <br />2. OUTSIDE AIR AND EXHAUST DUCT WORK SHALL BE GALVANIZED SHEET METAL WITH ALL JOINTS <br />SEALED WITH MASTIC. ROUND DUCT WORK SHALL BE "THERMOFIN" OR SINGLE WALL SHEET METAL. <br />DUCTS DO NOT NEED TO BE INSULATED UNLESS REQUIRED BY LOCAL JURISDICTION. ALL DUCT <br />SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA. <br />3. ALL DUCT SIZES DEPICTED ARE CLEAR INSIDE DIMENSIONS. <br />4. SUPPLY AIR DUCT SHALL BE SIZED AT 0.10"/100 FT. EQUAL FRICTION AND RETURN DUCT SHALL <br />BE SIZED AT 0.06"/100 FT. EQUAL FRICTION. <br />5. HOLD THE BOTTOM OF THE SUPPLY AIR DUCT A MAXIMUM OF 24" ABOVE LAY -IN CEILINGS TO ALLOW <br />FOR ACCESS TO BALANCING DEVICES. <br />6. PROVIDE A FLEXIBLE CONNECTION FROM EACH AIR HANDLER AND FAN TO THE DUCT SYSTEM. <br />7. FLEXIBLE RUNOUTS TO THE DIFFUSERS ARE LIMITED TO A MAXIMUM OF 25 FEET. <br />8. PROVIDE ACCESS PANELS IN DUCTS FOR ACCESS TO VOLUME DAMPERS, FIRE DAMPERS, FIRE/SMOKE <br />DAMPERS, DUCT MOUNTED SMOKE DETECTORS AND WHERE REQUIRED TO MAINTAIN EQUIPMENT. <br />9. ALL FLEXIBLE BRANCH CONNECTIONS SHALL HAVE A MANUAL VOLUME DAMPER INSTALLED AT THE <br />MAIN TRUNK FOR BALANCING PURPOSES. <br />CONTROLS <br />1. ALL TEMPERATURE CONTROLS SHALL BE 24 VOLT, AS PROVIDED BY THE MECHANICAL CONTRACTOR. <br />2. THERMOSTATS SHALL BE PROGRAMMABLE EQUAL TO HONEYWELL T8000 SERIES, OR BY UNIT <br />MANUFACTURER, WITH STAGES OF COOLING AND HEATING TO MATCH THE UNITS SELECTED. MOUNT <br />THERMOSTATS AT 5'0" AFF OR AS DIRECTED BY ARCHITECT/OWNER. <br />3. LOW VOLTAGE CONTROL WIRING SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR.THE <br />ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT FOR ALL CONTROL WIRING AS COORDINATED WITH <br />THE MECHANICAL CONTRACTOR. <br />4. LINE VOLTAGE (110 VOLT OR HIGHER) POWER AND CONDUIT SHALL BE PROVIDED BY THE <br />ELECTRICAL CONTRACTOR. <br />5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL DISCONNECT SWITCHES. DO NOT MOUNT <br />DISCONNECT SWITCHES OVER NAMEPLATES OR SERVICE PANELS. <br />6. TEST AND BALANCE SHALL VERIFY THE OPERATION OF ALL CONTROLS AT THE COMPLETION OF THE <br />PROJECT. <br />7. WHERE SMOKE DETECTORS ARE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR (NO FIRE <br />ALARM SYSTEM), EACH SMOKE DETECTOR SHALL BE EQUIPPED WITH A REMOTE TEST STATION <br />EQUIPPED WITH A VISUAL AND AUDIBLE ALARM TO BE LOCATED ADJACENT TO THE UNIT THERMOSTAT <br />IN ACCORDANCE WITH NFPA 90. <br />AIR DISTRIBUTION <br />SCHEDULE <br />DESIGNATION <br />DESCRIPTION <br />LEGEND <br />SPECIFICATIONS <br />EXAMPLE <br />CD1-10-270 <br />CEILING DIFFUSER <br />CD1 <br />PRICE ASCD SERIES, ALUMINUM, <br />NECK SIZE NOTED <br />10" <br />MODULAR CORE, LAY -IN MOUNTED, <br />CFM NOTED <br />270 <br />OFF-WHITE COLOR. <br />RG1-24x24-300 <br />RETURN GRILLE <br />RG1 <br />PRICE 610, ALUMINUM <br />FACE SIZE NOTED <br />24x24" <br />LOUVERED CORE, LAY -IN MOUNTED, <br />CFM NOTED <br />300 <br />OFF WHITE COLOR. <br />RG2-16x16-200 <br />RETURN GRILLE <br />RG2 <br />PRICE 610, ALUMINUM <br />FACE SIZE NOTED <br />16x16" <br />LOUVERED CORE, SURFACE MOUNTED, <br />CFM NOTED <br />200 <br />OFF WHITE COLOR. <br />NOTES: <br />1. SIZES AND CFM SHOWN ON THE LEGEND ABOVE ARE FOR EXAMPLE ONLY. SEE PLAN <br />FOR ACTUAL SIZES AND CFM VALUES USED ON THIS PROJECT. <br />2. LOCATE ALL AIR DISTRIBUTION PER THE ARCHITECTURAL REFLECTED CEILING PLAN <br />3. APPROVED MANUFACTURERS: PRICE, METALAIRE, KRUEGER, TITUS <br />BUILDING <br />AIR BALANCE <br />OUTSIDE <br />AIR INTO BUILDING <br />EXHAUST AIR OUT OF BUILDING <br />SOURCE <br />CFM <br />SOURCE <br />CFM <br />AHU-1 <br />AHU-2 <br />AHU-3 <br />AHU-4 <br />200 <br />120 <br />120 <br />160 <br />TEF-1 <br />TEF-2 <br />EXFILTRATION <br />50 <br />50 <br />400 <br />TOTAL OUTSIDE AIR IN = 600 <br />TOTAL EXHAUST AIR OUT = 500 <br />BUILDING <br />PRESSURIZATION = <br />+100 <br />OUTSIDE AIR CALCULATION SCHEDULE <br />SPACE <br />PEOPLE/SQUARE FEET <br />REQUIRED OA <br />PROVIDED CIA <br />OFFICE <br />22 / 3018 SF <br />313 <br />325 <br />PHARMACY <br />2 / 399 SF <br />82 <br />90 <br />SALES <br />6 / 733 SF <br />133 <br />140 <br />STORAGE <br />0 / 613 SF <br />37 <br />45 <br />NOTE: 1. OUTSIDE AIR VOLUMES ARE BASED UPON ASHRAE STANDARD 62.1 <br />SEEDS Engineering, Inc. <br />27730 Santa Anita Blvd. p: ( 813) 902-2515 <br />Wesley Chapel, FL 33544 f: ( 813) 902-2516 <br />jmakar@seedseng.com <br />Wiedrick <br />Architecture, Inc. <br />WIEDRICK ARCHITECTURE INC. <br />AA26001799 <br />2020 HEIDELBERG AVE. <br />DUNEDIN, FLORIDA, 34698 <br />STATE OF FLORIDA <br />REGISTERED ARCHITECT: <br />MATTHEW WIEDRICK <br />AR94577 <br />�4N14 M A EN.Q <br />SF., i <br />No.54827 <br />STATE OF <br />0 <br />. R10 • <br />� •NAI.EN�'� <br />PRn.IF(-T AnnRF.q.q- <br />Jb444 b I H AVI=. <br />ZEPHYRHILLS, FL 33542 <br />FLORIDA PHARMACY <br />SOLUTIONS, INC. <br />13933 17TH ST. SUITE 300 <br />DADE CITY, FL 33525 <br />MECHANICAL FLOOR PLAN <br />FLOOR FLAN <br />3/1G It =1'-011 <br />N(2) <br />Florida Certificate of Authorization No. 28278 <br />NI J VV <br />PROJECT #: 14022 <br />