Laserfiche WebLink
REQUIRED BY THE FBC <br />DEMO FLOOR PLAN <br />DEMOLITION NOTE5 <br />I. <br />THE GENERAL CONTRACTOR SHALL RIRNISH ALL LABOR AND MATERIALS REQUIRED TO <br />COMPLETE DEMOLITION, REMOVAL AND RE -USE OF ALL ITEMS SHOWN ON DRAWINGS. <br />2. <br />THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE <br />PRECAUTIONS TO PROTECT BUILDING: OCCUPANTS, MATERIALS AND EXISTING FINISHES <br />THROUGHOUT ALL PHASES OF CONSTRUCTION. OCCUPIED AREAS INCLUDING PUBLIC AREAS <br />ARE TO BE MAINTAINED BY THE GENERAL CONTRACTOR ANY DAMAGE TO <br />'EXISTING-TO-REMAN" CONSTRUCTION, MATERIALS OR EQUIPMENT MUST BE RESTORED TO <br />THERE ORIGINAL CONDITION. <br />3. <br />THE GENERAL CONTRACTOR SHALL ERECT ALL NECESSARY PLASTIC DROP CLOTH <br />PARTITIONS TO PROTECT ADJACENT BUILDING PROPERTY WHILE DEMOLITION AND <br />CONSTRUCTION IS N PROGRESS. <br />4. <br />ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES DAILY, EXCEPT ITEMS <br />TO BE RE -USED OR RETURNED TO THE OWNER OR AS DIRECTED OTHERWISE. <br />5. <br />THE GENERAL CONTRACTOR SHALL REMOVE ALL WALL CONDUITS, SWITCH PLATES, <br />TELEPHONE OR ELECTRICAL WIRING OR EQUIPMENT, ETC. TO THE SOURCE AFTER WALL <br />DEMOLITION. <br />b. <br />REFER TO THE NEW FLOOR PLANS FOR VERIFICATION OF THE EXISTING CONSTRUCTION TO <br />REMAIN AND EXTENT OF DEMOLITION. ALL EXISTING DOORS, FRAMES, HARDWARE, <br />CABINETRY, AND OTHER BUILDING STANDARD COMPONENTS REMOVED DURING <br />DEMOLITION AND NOT REUSED AS A PART OF THIS WORK ARE TO BE PROVIDED TO THE <br />OWNER - COORDINATE WITH OWNER PRIOR TO DEMOLITION. <br />1. <br />NOTIFY ARCHITECT IMMEDIATELY OF ANY PIPES, POSTS, DUCTWORK, SPRINKLER LINE OR <br />MISCELLANEOUS EQUIPMENT CONFLICTS TO NEW PARTITION AND REFLECTED CEILING PLAN <br />AFTER DEMOLITION IS COMPLETE. <br />8. <br />ALL DOORS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. <br />S. <br />ALL WINDOWS ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. <br />0 DEMOLITION KE � NOTE 5 <br />1. <br />EXISTING WALL AND/OR PORTION OF EXISTING WALL, STOREFRONT OR WINDOW TO BE <br />REMOVED- SEE NEW PLAN. PATCH FLOOR AS REQUIRED FOR NEW FINISH MATERIAL. <br />2. <br />EXISTING WALL FINISH MATERIAL AND FURRING TO BE REMOVED. REFERENCE NEW FLOOR <br />PLAN. <br />3. <br />EXISTING DOOR HARDWARE AND FRAME ASSEMBLY TO BE REMOVED. RETURN TO OWNER <br />IF REQUESTED - VERIFY WITH THE OWNERS CONSTRUCTION REPRESENTATIVE. <br />4. <br />EXISTING: FLOORING MATERIAL/FINISH TO BE REMOVED - PATCH SLAB AS REQUIRED. <br />REFERENCE NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />5. <br />EXISTING CEILING ASSEMBLY AND ALL FIXTURES TO BE REMOVED. RETAIN LIGHT FIXTURES <br />FOR RE -USE N NEW CEILING ASSEMBLY - REF. ELEC DRAWINGS <br />6. <br />ALL PLUMBING FIXTURES INCLUDING PARTITIONS TO BE REMOVED. CAP AND SEAL EXISTING <br />PLUMBING LINES AS REQUIRED - REFERENCE NEW FLOOR PLAN AND PLUMBING PLANS FOR <br />ADDITIONAL INFOR ATION. <br />1. <br />EXISTING HOOD ASSEMBLY TO BE REMOVED. RETURN TO OWNER IF REQUESTED - VERIFY <br />WITH THE OWNERS CONSTRUCTION REPRESENTATIVE. <br />8. <br />EXISTING STAIR AND MEZZANINE STORAGE AREA TO BE REMOVED. <br />9. <br />EXISTING FIRE RATED WALL ASSEMBLY TO REMAIN- REPAIR/PATCH AS REQUIRED. ALL <br />WORK TO COMPLY WITH UL REQUIREMENTS - REFERENCE LIFE SAFETY PLAN FOR <br />ADDITIONAL INFORMATION. PREP WALL AS REQUIRED FOR NEW TENANT FINISHES. <br />10. <br />REMOVE PORTION OF EXISTING SLAB AS REQUIRED FOR NEW PLUMBING - REF. PLUMBNG <br />PLANS FOR ADDITIONAL INFORMATIOK <br />11. <br />EXISTING MECHANICAL EQUIPMENT TO BE REMOVED - REF. MECHANICAL DRAWINGS <br />12. <br />EXISTING WALL ASSEMBLY TO REMAIN - PATCH AND REPAIR AS REQUIRED. <br />13. <br />THE SEVEN (1) EXISTING WINDOW ASSEMBLIES IN THE EXISTING EAST WALL ARE TO BE <br />REMOVED - REF. NEW FLOOR PLAN FOR INFILL INFORMATION. <br />14. <br />EXISTING PLASTIC WALL SHEATHING AT THE TOP OF THE EXISTING EXTERIOR WALL TO BE <br />REMOVED - REFERENCE NEW FLOOR PLAN FOR NEW INFILL INFORMATION. <br />DEMOLITION LEGEND <br />EXISTING WALLS TO REMAIN <br />— — — — — — — — — EXISTING WALL AND/OR PORTION OF EXISTING WALL, <br />— — — — — — — — — STOREFRONT OR WINDOW TO BE REMOVED. <br />EXISTING DOOR AND FRAME ASSEMBLY TO BE <br />REMOVED. <br />EXISTING TWO (2) HOUR FIRE RATED WALL ASSEMBLY. <br />REFERENCE DETAIL 3/A100 FOR UL INFORMATION. <br />NEW 3000 PSI CONC. WPBER''IGLASS <br />RE NFORCEMENT POUR BACK INCLUDE 03 BARS <br />18"LONG GTIVO.C. (STAGGERED) EACH SIDE. DRILL <br />AND ADHERE INTO EXISTING SLAB WITH 3-1/2" <br />EMBEDMENT WITH HILTI HIT RE-500-SD ADHESIVE <br />SYSTEM OR APPROVED EQUAL <br />POUR TOP OF TRENCH FLUSH TO MATCH <br />SURROUNDING AREA. <br />IO.ML. VAPOR BARRIER OVER ENTIRE AREA <br />EARTH FILL COMPACTED TO S% <br />W/TERMITE-INSECT TREATMENT. <br />SLAB INFILL DETAIL <br />3/4" =1'-0" <br />0 <br />W <br />0 <br />a <br />r <br />a <br />0 <br />0 <br />H <br />w <br />W <br />a <br />W <br />Of <br />Z <br />0 <br />0 <br />Z <br />Ld <br />W <br />W <br />Co <br />J <br />Q <br />_ <br />F_ <br />H <br />Wiedrick <br />------------- Architecture, Inc. <br />WIEDRICK ARCHITECTURE INC <br />AA26001799 <br />2020 HEIDELBERG AVE. <br />DUNEDIN, FLORIDA, 34698 <br />727.736.8627 <br />STATE OF FLORIDA <br />REGISTERED ARCHITECT: <br />MATTHEW WIEDRICK <br />AR94577 <br />z� a <br />N of) <br />Q M <br />LL <br />Lid J <br />� J <br />� <br />L <br />LI <br />Df <br />�-�_ <br />PROJECT ADDRESS: <br />38444 5TH AVE. <br />ZEPHYRHILLS, FL 33542 <br />CLIENT: <br />FLORIDA PHARMACY <br />SOLUTIONS, INC. <br />13933 17TH ST. SUITE 300 <br />DADE CITY, FL 33525 <br />DATE I DESCRIPTION I <br />DEMOLITION PLAN <br />MJW <br />PROJECT #: 14022 <br />Al <br />01 <br />10/15/14 <br />