My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38444 5th Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38444 5th Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 1:52:12 PM
Creation date
2/19/2025 1:58:38 PM
Metadata
Fields
Template:
Building Plans
Street #
38444
Location
5th Ave
Contractor
Cross Construction
Building Plans - Permit #
15890
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S <br />R-" <br />Existing <br />Landscape <br />Area <br />CONDENSER PAD <br />BY CONTRACTOR <br />ACOUSTIC CEILING <br />CONTINUOUS METAL RUNNER <br />CONTINUOUS METAL R-INNER. <br />ATTACH WITH P RAMSET 300 DIAM <br />NAILS 0320OC. MIN <br />SEALANT BOTH SIDES <br />BRACE TO STRUCTURE ABOVE <br />WITH KICKER STUDS 645 <br />DEGREES IN ALTERNATING <br />DIRECTIONS AS REQUIRED <br />OPT ION B <br />5/8" GWB EACH SIDE LPROVIDE J-MOLD <br />USE MR GM AT ALL TERMINATION FOR <br />WET AREAS OPTION B-BOTH <br />6" or 3 V 20 GA METAL SIDES <br />STUDS * 16" OC. <br />BASE AS SCHEDULED <br />SEALANT BOTH SIDES <br />FINISH FLOOR <br />GENERAL CONFRUCTION NCTE5 <br />1. REFER TO THIS SHEET FOR PARTITION TYPES AND SECTIONS. <br />2. PROVIDE lU FIRE EXTINGUISHER PER 30M SQUARE FEET OF USABLE OCCUPIED SPACE OR 15 <br />FEET OF TRAVEL. <br />3. VERIFY ALL STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS AND COORDINATE <br />REQUIRED CHANGES WITH OWNER PRIOR TO CONSTRUCTION. <br />4. VERIFY ALL DIMENSIONS SHOWN ON PLAN, DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT WITH <br />ANY DISCREPANCIES PRIOR TO CONSTRUCTION. <br />5. PROVIDE SUFFICIENT NUMBER OF 4°-0" X V-0" X 3/4" THICK FIRE RATED SHEETS OF PLYWOOD <br />TO HOUSE PHONE/ DATA EOJIPMENT. PAINT TO MATCH WALLS. <br />6. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE <br />MAINTAINED AT A CONSTANT LEVEL RELATIVE TO THE CEILING PLANE. <br />1. WET LOCATIONS (INCLUDING TOILET AREAS, MOP AND SINK AREAS, LAUNDRY, ETC) ARE TO <br />HAVE WALLS CONSTRUCTED WITH MOISTURE RESISTANT GWB. <br />8. ALL EXPANSION JOINTS IN FIRE -RATED WALLS ARE TO MAINTAIN THE ASSEMBLY FIRE RATING. <br />3 ALL EXISTING LOCKS AND LATCHES USED TO PREVENT THE OPERATION OF AN EXIT MUST <br />COMPLY WITH THE 2010 FBC SECTION I008 - SPECIFICALLY SECTION 1008.IB3,1008.18.4 AND <br />1008.15 <br />10. REPAIR ALL EXISTING WALLS AS REQUIRED TO RECEIVE PANT COORDINATE FINAL FINISH <br />SELECTION WITH OWNER, <br />IL CASEWORK IS WM FOR REFERENCE ONLY- CASEWORK IS NOT INCLUDED IN THIS SCOPE OF <br />WORK, AND WILL BE PROVIDED UNDER A SEPARATE FUTURE CONTRACT WITH THE OWNER <br />NEW LEGEND <br />000 DOOR NUMBER- REF. SHEET A600 <br />000 I ROOM NAME/NUMBER <br />F.E. WALL MOUNTED 10 LB. 4A605C FIRE <br />EXTINGUISHER <br />NEW FULL HEIGHT WALL - REFERENCE PARTITION TYPES FOR <br />ADDITIONAL INFORMATION <br />EXISTING WALL ASSEMBLY TO REMAIN - V.I.F. <br />EXISTRING AND NEW FIRE RATED WALL ASSEMBLY - REFERENCE <br />THE LIFE SAFETY SHEET FOR ADDITIONAL INFORMATION. <br />........................ <br />........................ <br />........................ <br />........................ <br />........................ <br />........................ <br />........................ <br />ADJACENT OCCUPIED TENANT SPACE - MERCANTILE. <br />NO WORK IN THIS AREA <br />00 WINDOW SYMBOL - REF. A ---- <br />SEE SECTIONS <br />UJAL L /PART I T I ON T�� 5 FOR EXTERIOR F�SHLEVATIONS <br />1-14R FIRE RATING: 5/6" TYPE "X" GYPSUM BOARD <br />(EACH SIDE) ON 6" 20 GA METAL STUDS AT 16" OC., <br />❑1 EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL <br />ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. <br />PROVIDE MOISTURE -RESISTANT GYP BD IN WET AREAS <br />(SEE GENERAL CONSTRUCTION NOTE 01 ABOVE). <br />PROVIDE UL419 ASSEMBLY FOR I-HR FIRE RATING. <br />la NON -FIRE RATED WALL ASSEMBLY - REF. DETAIL 2/A102 <br />-- . ........... ----- - - ------ --..... ---- -.....--- - - ------------------ ----------- ---------- - --...... ......... ....- -............................................ ........... <br />I-HR FIRE RATNG: 5/8" TYPE "X" GYPSUM BOARD (EACH <br />SIDE) ON 3-5/8" 20 GA METAL STUDS AT 16" OC., <br />❑2 EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, FILL <br />ENTIRE CAVITY WITH SOUND ATTENUATION BATTS. <br />PROVIDE UL U41S ASSEMBLY FOR 1-14R FIRE RATING. <br />-------............. . ........ _.......... ........................... ....................................__............... ........................ .............. _..._ ............ <br />EXISTING WAIL ASSEMBLY v.IF. ❑3 EXISTING WALL ASSEMBLY TO REMAIN - V.IF. <br />5/8" GYPSUM BOARD (EACH SIDE) OVER 3-5/8" <br />20 GA MTL STUDS AT 16" O.C., -REF. DETAIL 2/AI02 FILL <br />CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE <br />RESISTANT GWB IN ALL BATHROOMS AND OTHER WET <br />LOCATIONS. <br />EXISTING WALL ASSEMBLY V.IF. PROVIDE 5/8" GYP. BD. OVER 1-1/2" HAT CHANNELS AT <br />16" OC. EXTEND INTERIOR MATERIALS (ON EXTERIOR <br />❑5 WALLS) TO EXISTING ROOF DECK ABOVE. PROVIDE 5/8" <br />MOISTURE RESISTANT GYP BD N WET AREAS (SEE <br />GENERAL CONSTRUCTION NOTE'1 ABOVE). PROVIDE <br />LINE ITEM FOR RIGID INSULATION BOARD - VERIFY WITH <br />TENANTS CONSTRUCTION REPRESENTATIVE. <br />------ ----------- ------ -------- - ---- - -- - ----....._._.......... _....... .......................... - ...... - - - --- --------------------- --------------- <br />5/8" GYPSUM BOARD (INTERIOR SIDE) OVER 3-5/8" <br />EXISTING WALL ASSEMBLY V.IF. 20 GA MTL STUDS AT 16" O.G., -REF. DETAIL 2/AI02 FILL <br />CAVITY WITH SOUND ATTENUATION BATTS. USE MOISTURE <br />RESISTANT GWB IN ALL BATHROOMS AND OTHER WET <br />LOCATIONS. <br />Wiedrick <br />................ Architecture, Inc. <br />WIEDRICK ARCHITECTURE INC. <br />AA26001799 <br />2020 HEIDELBERG AVE. <br />DUNEDIN, FLORIDA, 34698 <br />727.736.8627 <br />STATE OF FLORIDA <br />REGISTERED ARCHITECT: <br />MATTHEW WIEDRICK <br />AR94577 <br />z <br />O <br />LLI <br />ICT <br />N M <br />M <br />LL <br />�--+ (n <br />U-) J <br />� 2 <br />00 >- <br />M � <br />W <br />J w <br />0 N <br />Q <br />0 <br />U <br />H <br />w <br />W <br />a <br />Z <br />PROJECT ADDRESS: <br />z 38444 5TH AVE. <br />ZEPHYRHILLS, FL 33542 <br />W <br />of <br />W <br />m <br />J <br />Q <br />_ <br />CLIENT: <br />FLORIDA PHARMACY <br />SOLUTIONS, INC. <br />13933 17TH ST. SUITE 300 <br />DADE CITY, FL 33525 <br />DATE I DESCRIPTION I <br />ALTERED FLOOR PLAN <br />MJW <br />PROJECT #: 14022 <br />Al <br />02 <br />10/15/14 <br />ALTERED FL <br />OCR PLAN <br />INTERIOR FAR <br />I-1/2" = 1'-0" <br />TITION <br />oPtioNs <br />a <br />
The URL can be used to link to this page
Your browser does not support the video tag.