Search
4630 Wisteria Dr
Zephyrhills
>
Building Department
>
Building Plans
>
4630 Wisteria Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:37:25 PM
Creation date
2/19/2025 1:59:53 PM
Metadata
Fields
Template:
Building Plans
Street #
4630
Location
Wisteria Dr
Contractor
Ronald and Fannie Barnett
Building Plans - Permit #
9713
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P <br />LINTEL$ ON THIS PROJECT ARE AS SPECIFIED ON THIS <br />CHART UNLESS NOTED ON FLOOR PLAN BY OPENING <br />LINTEL LOAD CHART l 16" DEEP SECTION � <br />CLEAR SPAN <br />CONCRETE U LINTEL <br />"POWER" STEEL <br />"POWER" STEEL <br />BOX LINTEL <br />4981 PLF f UNFILLED) <br />1010 PLF L-2 <br />9865 PLF <br />2' - 2" <br />3435 PLF( UNFILLED) <br />6626 PLF L-2 <br />6830 PLF <br />2'- 8" <br />2 M PLF f UNFILLED) <br />5296 PLF L-2 <br />5549 PLF <br />3' - 2" <br />2332 PLF ( UNFILLED) <br />4508 PLF L-2 <br />4613 PLF <br />4' - 0" <br />1835 PLF f UNFILLED) <br />3535 PLF L-2 <br />3699 PLF <br />4'- 6" <br />1624 PLF l UNFILLED) <br />3154 PLF L-2 <br />3288 PLF <br />5' - 2" <br />213S PLF - <br />2146 PLF L-2 - <br />2864 PLF - <br />6' - 2" <br />2211 PLF - <br />22SO PLF L-2 - <br />2400 PLF » <br />1- 0" <br />1981 PLF - <br />2025 PLF L-2 - <br />2114 PLF - <br />8' - O" <br />1123 PLF « <br />1-168 PLF L-2 - <br />2213 PLF « <br />9' - 2" <br />1489 PLF » <br />1545 PLF L-2 - <br />1984 PLF » <br />10' - ON <br />13" PLF « <br />1414 PLF L-2 - <br />ISIS PLF - <br />10' - 8" <br />1211 PLF « <br />1325 PLF L-2 - <br />1110 PLF - <br />11' - 2" <br />1200 PLR « <br />1230 PLF L-2 » <br />1629 PLF - <br />12' - On <br />1109 PLF » <br />1118 PLF L-2 - <br />1515 PLF » <br />12' - 8" <br />V44 PLF » <br />1116 PLF L-2 - <br />1436 PLF « <br />13' - 4" <br />13SS PLF « P <br />1381 PLF L-2 » SL - 1 <br />1364 PLF » <br />14' - ON <br />1371 PLF » P <br />1321 PLF L-2 « SL - 1 <br />1299 PLF - <br />16'-O" <br />1152PLF -P <br />1048PLF L-2-SL-1 <br />1131PLF- <br />18' - on <br />1016 PLF « P <br />828 PLF L-2 - SL - I <br />S60 PLF » <br />18' - 8" <br />9T1 PLF - P <br />T10 PLF L-2 - SL - I <br />893 PLF » <br />20' - ON <br />816 PLF - P <br />629 PLF L-2 « SL - 1 <br />184 PLF « <br />22' - 8" <br />189 PLF - P <br />523 PLF L-2 » SL - 1 <br />606 PLF" <br />« - DENOTES 45 RESAR X CONT, PLACED IN BOTTOM COURSE AND <br />I6" DEEP BEAM POURED SOLID WITH 2500 PSI C ONCRETE <br />« P - DENOTES PRE STRESSED U LINTEL WITH 05 REBA R X CONT, <br />PLACED IN BOTTOM COURSE 4 16" DEEP BEAM POURED SOLID <br />WITH 2500 PSI CONCRETE <br />8' X 8" X 16" KNOCK OUT BLOCK <br />TOP COARSE WITH I 43 HORIZONTAL <br />REBAR TIED TO ALL VERTICAL RODS <br />BOx STEEL LINTEL& OVER ALL WINDOW <br />AND DOOR OPENINGS, NO "8 REBAR <br />RM URED ON BEAM& UP TO 24'0" <br />' WITH NO MORE THAN 606LB8 PLF <br />POWER BOX LINTEL DETAIL <br />8" X 8' X 16" KNOCK OUT BLOCK <br />TOP COARSE WITH 1 15 HORIZONTAL <br />REBAR TIED TO ALL VERTICAL RODS <br />8" PRECAST LINTEL BLOCK <br />OVER ALL OPENINGS, 1 EACH <br />• • 05 REBAR IN THIS COARSE WHEN <br />SPAN OF LINTEL OVER W2" <br />STANDARD PRECAST DETAIL <br />GARAGE DOOR TO BE REINFORCED <br />TO MEET WIND LOAD AND COMPRESSION <br />RATINGS FOR YOUR JOB LOCATION. <br />8" X 6" X 16" KNOCK OUT BLOCK <br />TOP COARSE WITH 1 "5 HORIZONTAL <br />REBAR TIED TO ALL VERTICAL RODS <br />8 X 8 X 16' KNOCK OUT BLOCK <br />OVER POWER STEEL LINTELS, WITH <br />1 EACH "5 RE15AR IN THIS COARSE <br />WHEN SPAN OF LINTEL IS OVER 12'4" <br />POWER STEEL LINTEL DETAIL <br />HORIZONTAL LINTEL 85 REBAR <br />HOOK LAPS MINIMUM <br />10" WI 2 TIE& <br />FOOTER 'S REBAR <br />ROD CHAIRS <br />I SAR�P����ILS <br />CEILING RAFTER <br />L ALL TRACK AND HARDWARE SECURED <br />PER MANUFACTURE SPECIFICATIONS TO <br />MEET WIND LOAD AND COMPRESSION <br />RATINGS FOR YOUR JOB LOCATION <br />MINIMUM 2Xb P.T. SIDE PLATE ATTACHED <br />TO BLOCK WALL USING I/2"X8" ANCHOR <br />BOLTS OR 13/8"57" EXPANSION BOLTS <br />4 EACH SIDE. ATTACH TOP 2X6 WITH <br />2 3/8" T NAILS I6" Or, <br />GARAGE DOOR ATTACHMENT DETAIL <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOOSES AND <br />EXPENSED (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR REOULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />1/2" CDX OR l/Ib" OSB ROOF SHEATHING <br />NAILED PER ROF SHEATHING DETAIL WITH <br />WITH 8D R,S NAILS, USE STEEL PLYCLIPS <br />AND 015 FELT AND METAL ROOFING <br />e <br />SEE ROOF TRUSS PLAN <br />2X4 WOOD SUB WITH <br />ALUMINUM SOFFIT AND <br />FASCIA TRIM <br />SEE LINTEL CHART <br />ALUMN S.N. WINDOWS <br />MASONRY SILLS <br />20" X 1211 FOOTINGS WITH <br />(2) 03 REBAR ON CHAIRS <br />0 <br />12�—I 411 <br />ENGINEERED ROOF <br />TRUSSES 24" OC <br />1/2" CEILING TYPE <br />GYPSUM BOARD <br />SINGLE BOND BEAM WITH (1) IS <br />REBAR CONTINUOUS TIED TO ALL <br />VERTICAL RODS <br />TYPICAL 4" CONCRETE SLAB WITH WIRE MESH <br />OR FIBER MESH AND 6 MILL VISOUEEN OVER <br />CLEAN COMPACT TERMITE TREATED SOIL <br />05 VERTICAL RODS FROM <br />FOOTINGS TO BOND BEAM <br />WITH 25" LAP MINIMUM <br />S' 0" 5LOCK WALL DETAIL <br />NOT TO SCALE <br />DRILL I" X 6" HOLE INTO EXISTING BOND BEAM <br />AND EPDXY 4S REBAR FROM NEW BOND BEAM <br />INTO EXISTING BOND BEAM, <br />DRILL I"X6" HOLE INTO EXISTING WALLS <br />AND EPDXY 05 REBAR FROM NEW BLO( <br />INTO EXISTING BLOCK WALL. REEIAR TC <br />LONG WITH b" INTO EXISTING WALL b" IN <br />BLOCK WALL <br />DRILL I" X 6" HOLE INTO EXISTIt, <br />AND EPDXY 05 REBAR FROM NEW FOOTINGS <br />INTO EXISTING FOOTINGS <br />TOP AN <br />ID IN BETWEEN <br />NEW BLOCK WALL TO EXISTING WALL DETAIL <br />ATTACH MINIMUM 3/4" P.T, BUCK <br />STRIP THAT IS THE MINIMUM WIDTH <br />OF DOOR FRAME USING ,OSIXI 3/8" <br />T- NAILS MAXIMUM 10" 00, <br />LIN <br />CAULK DOOR FRAME PER YOUR <br />MANUFACTURES RECOMMENDATIONS <br />NOT TO SCALE <br />SECURING PREHUNG TO BUCK STRIPS <br />PER YOUR MANUFACTURES INSTRUCTIONS <br />TO MEET WIND LOADS AND COMPRESSIONS <br />RATINGS FOR YOUR JOB LOCATION, ALL <br />ANCHOR SCREWS MUST PENETRATE BLOCK <br />WALL A MINIMUM OF 1 1/4" AND THERE SHALL <br />BE A MAXIMUM 1/4" SPACE BETWEEN BUCK <br />AND DOOR JAMB <br />BLOCK DOOR ATTACHMENT DETAIL <br />O <br />�Q <br />O <br />cv <br />O <br />O <br />201811 <br />41011 <br />•------------------------------------------------------- <br />I� it <br />1 I L9 <br />1 <br />1 <br />I , s <br />I 1 irl <br />I� <br />II <br />li �1 <br />1 <br />I� it <br />I� it <br />I� it <br />li ,I <br />1 , <br />II 11 <br />I� it <br />I� ilk <br />1 , <br />II 11 <br />1 <br />II it <br />1 <br />I� .I <br />I� .I <br />I� it <br />— — — — — — — — — — — — — — — — <br />� 1 1 <br />ICI <br />1 1 <br />I11 <br />1 1 1 <br />1 <br />1 , <br />I I I <br />' CUT AWAY EXISTING SLAB TO ALLOW <br />OR NEW FOOTING. POUR NEW SLAB <br />I 1 I OVER TOP OF EXISTING SLAB TO <br />1 i RAISE SLAB ELEVATION SAME AS <br />I EXISTING GARAGE <br />II1 <br />I <br />I <br />1 <br />III <br />I <br />1 1 <br />I 1 1 <br />I I SEE NEW TO EXISTING <br />BLOCK WALL DETAIL <br />REMOVE EXISTING BLOCK WALL \_ <br />\\\\\\CaRACxE <br />ADD POURED CELL AT THIS E <br />BELOW NEW LINTEL WITH (1) 05 <br />RE15AR <br />\ THIS END NO CHANG <br />12'0"XI'O" GARAGE DOOR <br />CUT AWAY WALL AT THIS END <br />TO ALLOW FOR LARGER DOOR. <br />ADD NEW LINTEL, <br />21' 111 <br />FOUNDATION FLAN 1/4II = 11 oil <br />PRODCUT CATEGORY <br />APPROVED PRODCUT LIST <br />SUB CATEGORY MANUFACTURER <br />STATE OF FL <br />APPROVAL " <br />STRUCTURAL COMPONET <br />HETA20 <br />SIMPSON <br />FL 11413 <br />STRUCTURAL COMPONET <br />MT6MI6 <br />SIMPSON <br />FL 11413 <br />STRUCTURAL COMPONET <br />LINTEL BOX <br />POWERS STEEL INC <br />FL 11383.1 <br />STRUCTURAL COMPONET <br />DOOR HEADER <br />WEKIWA CONCRETE <br />FL 1418 R-2 <br />ROOFING <br />METAL <br />UNION CORRIGATED IND <br />FL 6895 <br />ROOFING <br />015 OR 030 FELT <br />ATLAS ROOFING <br />FL 4064,1 <br />ROOFING <br />METAL <br />UNION CORRIGATED IND <br />FI6895.1 <br />EXTERIOR DOOR <br />SINGLE SWINGING <br />PLA&T PRO <br />FL 4164.1 <br />EXTERIOR DOOR <br />GARAGE <br />OVERHEAD DOOR <br />FL 10499.2 <br />80FFIT 1 FASCIA TRIM <br />SOFFIT AMERICAN CONSTRUCTION METALS <br />FL 12019,1 <br />05 VERTICAL RODS FROM FOOTINGS <br />BELOW TO TOP OF WALL. PLACED AT <br />ALL CORNERS, EACH SIDE OF ALL <br />OPENINGS AND SPACED MAXIMUM <br />8' O" Oc. <br />SEE NEW TO EXISTING <br />BLOCK WALL DETAIL <br />EXISTING <br />ARKAY ENGINEERING INC. <br />STRIpTURAL ENGINEERS <br />/leiHARD L, KIDD ' P.E. <br />FLORIDA LICENSE NUMBER 31296 <br />I HERBY CERTIFY Ti-IAT THESE PLANS AND SPECIFICATIO NO <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 O F THE <br />FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) <br />WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 <br />FLORIDA BUILDING CODE RESIDENTIAL AND 2009 SUPPLEMENTS <br />4y <br />v �W <br />�yHyO <br />^4 " <br />QN Q <br />� �h- <br />DO <br />t� <br />M <br />V� <br />3,tsN� <br />W <br />pReNZ <br />w' <br />O <br />�e71i <br />W� <br />s <br />QQ <br />v M*� <br />Z�==4-J <br />z�_� <br />�&L <br />,f , j ( 0 <br />=L.J <br />F- <br />0 <br />Z <br />O <br />N <br />rQ <br />Q <br />0 <br />fu Z <br />'^4 al <br />I-- <br />z u- <br />Q <br />E <br />lU <br />z <br />O <br />GARAGE <br />560 <br />SQ. FT, <br />FIG <br />20r-3 <br />ARKAY <br />