GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE <br />RESIDENTIAL AND 200E SUPPLEMENTS <br />ARKAY ENGINEERING INC, A REGISTERED LICENSED, PLO RIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY, HAS APPLIED " RATIONAL ANALY 616' FOR THE: STRUCTURAL DESIGN <br />OF THIS STRUCTURE <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADD IN" &HALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS <br />FLOORS, <br />LIVE LOAD6 - 40 P,6,F. <br />DEAD LOAD6 - 10 P,6,F, <br />GARAGE SLAB, <br />LIVE LOADS - 50 P.6,F, <br />DEAD LOADS - 10 P.&.F, <br />ROOF, <br />LIVE LOADS (TRU66 TOP CORD) - 20 P.6, F. <br />DEAD LOADS (TRUSS TOP CORP) - 10 P.S.F. 18 P.6,F. WHEN TILE ROOF INSTALLED <br />DEAD LOAD (TRU66 BOTTOM CORD) - 10 P.6 F. <br />ASSUMED TRU66 SELF WEIGHT ( DEAD LOAD) - 1 P,6,F, <br />WIND DE61GN A6SUMPTIONS, <br />BUILDING EXPOSURE - D <br />BUILDING IMPORTANCE FACTOR - 1.0 <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 4 EXPOSURE ADJUSTMENTS COE'FICIE NT • 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRE66ME COEFFICIENT - . / - 0 .I8 <br />SEE WIND SPEED AT BOTTOM RIGHT OF ALL SW EET6 <br />STUCCO THICKNES: <br />OVER FRAME GABLE 1/8' STUCCO OVER FELT BACKED GALV <br />LATH <br />OVER MA60NARY WALL 1/2" 2 COAT STUCCO <br />GABLE ENDS WITH SIDING BACK WITH 015 FELT <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN DA6ED UPON AN ALLOWABLE 6 OIL BEARING CAPACITY OF <br />2000 P.6.P.( MINIMUM ) THE CONTRACTOR/PROPERTY OW NOR IS RE6110ON61SLE FOR VERIFYING <br />THAT THE 601L ON THE 617E 16 PROPERLY PREPARED AN D COMPACTED 6UC14 THAT IT CAN <br />SUPPORT A 2000 P.B.F. FOUNDATION LOADING <br />ARKAY ENGINEERING INC, A REGISTERED LICENSED PLOR IDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY, DESIGNED THESE FOUNDATION6 W ITHOUT VISITING THE CONSTRUCTION <br />SITE NOR PERFORMING ANY &OIL TESTING <br />ARKAY ENGINEERING INC SHALL NOT BE RESPONSIBLE FO R THE 61TE 601L ABILITY TO SUPPORT <br />THE BUILDING LOADS <br />FOUNDATION 4 SLAB - ON- GRADE NOTES <br />BUILDING 61TE SHALL BE SCRAPED TO REMOVE ALL ORGA NIC MATERIALS,. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AR EA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P.6.F. FOUNDATION LOADING. SLAB <br />SHALL BE PLACE OVER A b MIL VAPOR BARRIER ON CLEA N ADEQUATELY COMPACTED <br />AND TERMITE POISONED 601L <br />CONCRETE UTILIZED IN THE FOUNDATION AND SLABS 614A LL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 3000 P,&,I, <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND 1 DENTIFIED IN ACCORDANCE <br />WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED 614A LL BE A MINIMUM OF 25" FOR <br />05 REBAR , 30' FOR @6 REBAR 4 35" FOR 01 REBAR <br />PLANS ARE ENGINEERED FOR A MAXIMUM 6TEMWALL HE" T OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) THE CONTRACTOR OR 15UILDING OW NER 614ALL DETERMINE TWO <br />EXACT 6TEMWALL HEIGHT BASE UPON SITE CONDITIONS P RIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 CO UR6E ARE REQUIRED <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE'"VEY SHALL BE ON 61TE <br />FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS 614ALL BE EXPOSED AND A <br />STRING 6TRECTED FROM MARKER TO MARKER TO VERIFY R EQUIRED SET BACKS <br />MASONRY WALLS, <br />CONCRETE MA60NRY UNIT SHALL BE HOLLOW UNIT MAb0NR Y IN ACCORDANCE WITH A6TM C-W <br />AND 614ALL HAVE MINIMUM F'M OF ISOO P.6,1. <br />MORTAR SHALL CONFORM TO A67MC -210 AND SHALL BE E ITHER TYPE M OR 6 <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND I DENTIFIED IN ACCORDANCE <br />WITH ASTMA-615. LAP SPLICES WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR 65 REBAR <br />30" FOR 06 RESAR AND 35" FOR 01 RESAR. <br />GROUT FOR THE POURED CELLS AND LINTEL6 SHALL HAVE A MAXIMUM COURSE AGGREGATE 61ZE <br />OF 3/8' PLACED AT 8 TO II INCH SLUMP AND HAVE A M INIMUM 28 DAY COMPRESSIVE STRENGTH OF <br />2000 P.S.I. ( WHEN TESTED PER A6TM C-1019 ) <br />PROVIDE CLEAN OUT OPENINGS ( 12 60, IN, ) IN CELL 6 CONTAINING SPLICED REINFORCEMENT. WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT <br />SOIL TERMITE TREATMENTS <br />TERMITE PROTECTION SHALL BE PROVIDED BY RECS16TNRE D TERMITICIDO6, INCLUDING PE6TICIDE6 <br />APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, OR OT14E R APPROVED PROTECTION LABELED FOR <br />USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, <br />A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO T HE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OC CUPANCY WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE, (PER FBC R320.1) <br />THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FO R THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT 16 INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT <br />OF AGRICULTURE AND CONSUMERS SERVICES <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM 16 TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION <br />SECTION R320.1 THROUGH R320.I,6 DO NOT APPLY, A 6 IGNED FIVER EYAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING IN6TALLA TION. MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE? BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVA L ( PER FBC R320.1.1) <br />INITIAL 601L POISONING TREATMENT SHALL BE DONE AP TER ALL EXCAVATION <br />BACKFILLING 4 COMPACTION ARE COMPLETE ( PER FBC 3 20.1.2.) <br />ANY 601L DISTURBED AFTER THE INITIAL TREATMENT 614 ALL BE RE- TREATED <br />INCLUDING ANY BOX OR FORMED AREAS ( PER FBC R320. 1,2) <br />BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAP& SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MOT BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DI&TURBANC E OF THE 601L AFTER TWO <br />INITIAL TREATMENT ( PER FBC R32013) <br />I <br />O I O I © O <br />in - <br />- Oyu �;-- <br />---—-—- — - — <br />- -- ' <br />P 0 I (D <br />0 I <br />T y <br />IL <br />510. <br />O— - — - — - — - <br />01 --�- <br />© RIDGE I <br />8 <br />o <br />5o" p I o <br />® ® Q © <br />GABLE END <br />5' 0" <br />PARTIAL ROOF PLAN <br />PANEL EDGE SUPPORT FOR NARROW WIDTH ROOF EDGE <br />PER APA TECHNICAL NOTE RMA, 16" - 24' INCH PANE LS <br />DOUBLE PLY CLIP THE SIDE ADJACENT TO THE PULL WID TH <br />PANE- NONE REQUIRED AT RIDGE OR HIP, 12" - 16" L UMBER <br />ONLY BLOCKING (2X4) FLAT WISE OR EDGEWISE ON THE SIDE <br />ADJACENT TO THE FULL WIDTH PANEL NONE REQUIRED AT <br />RIDGE OR HIP. 12" OR LESS USE LUMBER ONLY BLOCKING <br />(2X4) FLAT WISE OR EDGEWISE ON BOTH PANEL EDGE& <br />A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT SHALL <br />BE REQUIRED (PER FBC R320.1.4) <br />ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIAL 6 ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, ( PER FBC R320.1.5) <br />EXTERIOR 601L TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12" OF THE STRUCTURE SIDE WALLS (PER FBC R 320.1.6) <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE IN STALLED AFTER CONSTRUCTION 16 <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY 601L DISTURBED AFTER THE <br />VERTICAL BARRIER 16 APPLIED, SHALL BE RETREATED (PER FBC R320.1.6) <br />CONDENSATE AND ROOF DOWN SPOUTS D16CI4ARGE AT LEA6 T 12" AWAY PROM THE BUILDING <br />SIDE WALLS (PER FBC R320.1) <br />AFTER ALL WORK IS COMPLETE ANY L006E WOOD AND FIL L MUST BE REMOVED PROM <br />BELOW AND WITH IN 12" OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES TUB <br />TRAP BOXES, FORMS, SHORING AND ANY OTHER Cm 11ILOS E CONTAINING MATERIALS <br />PER (FBC R320.8.3.) <br />THE D16TANCE FROM THE EXTERIOR WALL COVERING ( EX CEPTIONS, PAINT AND DECORATIVE <br />CEMENTITIOU6 FIN16H LE66 THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6' T O ALLOW FOR INSPECTION FOR FUTURE <br />TERMITE INFESTATIONS (PER RIC R104) <br />EXTERIOR WINDOWS 4 DOORS: <br />ALL EXTERIOR WINDOWS 4 GLAS6 DOORS OR ENTRANCE DO OR 614ALL BE TESTED IN ACCORDANCE WITH <br />AN61/AMMA/NUJWDA 101/162 STANDARD AND BEAR AN AMMA OR WOMA LABEL IDENTIFYING THE MANUFACTURE <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY <br />ALL MULLIONS AND ADJACENT DOOR/IOINDOW ASSEMBLIES SHALL BE TEST OR ENGINEERED TO TRANSFER <br />1.5 TIMES THE DE61GN LOADS TO THE ROUGH OPENING 6 U56TRATE <br />INSTALL ALL WINDOWS AND DOOR ASSEMBLIES PER THE M ANUFACTURE ANCHORING RECOMMENDATIONS <br />TO ACHIEVE THE DESIGN PRE66URF0 SPECIFIED <br />ELECTRICAL, PLUMBING, 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411,003 (2) (U OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS 614ALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMB ING AND MECHANICAL SYSTEMS DRAWN HERON <br />ARE BASE UPON A DESIGN PROVIDED BY THE OWNER TO A DDRE66 MI6/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WI THIN b- FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHAD- BE WIRED INTO A GROUND F AULT INTERRUPTER "CFI" CIRCUIT <br />"AFI" CIRCUIT <br />ALL ELECTRICAL OUTLETS IN BEDROOMS 4 FIXTURES 614 ALL BE WIRED INTO AN ARC-PAULT INTERRUPTER <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AN D IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />GROUN'J WIRE FORM REBAR TO ELECTRICAL PANEL PER N. E.C. <br />DUCTS IN GARAGE AND DUCT6 PENETRATING THE WALL6 O R CEILINGS SEPARATING THE DWELLING FROM THE <br />GARAGE SMALL BE CONSTRUCTED OF MINIMUM NO,26 GAUD E SHEET STEEL OR OTHER APPROVED MATERIALS <br />AND &HALL HAVE NO OPENINGS INTO THE GARAGE ( FBC 2004 R305.1.1.) <br />SAFETY GLAZINGs <br />TWO FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARD OUS LOCATION FOR THE PURPOSE OF <br />GLAZING <br />(I) GLAZING IN SWING DOOR&, FIXED AND SLIDING PAN EL OF SLIDING DOORS <br />ASSEMBLIES <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUB6, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY P ORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING 16 LE66 <br />THAN 60" ABOVE THE DRAIN INLET <br />(3) GLAZING IN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24" RAP IU6 OF THE DOOR IN A CLOSED <br />POSITION AND WW06E BOTTOM EDGE 16 LESS THAN 6 0" ABOVE THE FINISH FLOOR OR <br />WALKING SURFACE <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PA NEL OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE . THAT M EET6 ALL OF THE FOLLOWING <br />(A) EXPOSED AREA OF AN INDIVIDUAL PANE GREAT OR THAN 9 60, FT, <br />(B) BOTTOM EDGE LE66 THAN 18" ABOVE THE FLOOR <br />(C) TOP EDGE GREATER THAN 36" ABOVE THE FLOOR <br />(D) ONE OR MORE WALKING SURFACES WITHIN 36" HORIZONTALLY <br />OF THE PLANE OF THE GLAZING <br />REFER TO THE 2001 FLORIDA BUILDING CODE RE61DENTI AL - SECTION R306 FOR <br />ADDITIONAL AREAS THAT MAY BE CONSIDERED A HAZARDO US LOCATION FOR THE <br />PURP06E OF GLAZING <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />DRAFfSTOPPINGs <br />PRIOR TO REQUESTING TWO FRAMING INSPECTION. <br />IN SINGLE FAMILY DWELLINGS, DRAFTOTOPPING6 SHALL BE PROVIDED ( PARALLEL TO THE MAIN <br />FRAMING MEMBERS) IN FLOOR / CEILING ASSEMBLIES SE PARATING USEABLE SPACES. DRAFT6TOPPING <br />SHALL BE CONSTRUCTED SUCH THAT THE FLOOR / COLIN G ASSEMBLEY 16 BROKEN UP INTO TWO OR MORE <br />APPROXIMATED AREAS WITH NO AREA GREATER THAN 1000 60.FT. <br />ATTIC ACCESSs <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXC EEDING 30 60. FT, AND HAVING <br />MINIMUM 30 INCHES OF VERTICAL HEIGHT. ROUGH FRAME D OPENING NOT BE LESS THAN 22"X30" <br />INCHES, WHEN MECHANICAL EQUIPMENT IS LOCATED IN T HE ATTIC IT &HALL BE INSTALLED IN <br />ACCORDANCE WITH 2O04 FLORIDA BUILDING CODE RE61DE NTIAL - SECTION M1305.1.3 <br />TIMBER MATERIALS, <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSU RE TREATED <br />MATERIALS <br />TRUSSES, <br />IF THE CONTRACTOR , TRU86 MANUFACTURE OR ANY OT14E R DE61GN IDROPE66IONAL REV16E THE <br />TRU66 SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PL AN6 ARKAY ENGINEERING, INC 16 <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMEN T6 FOR COMPLIANCE WITH THE <br />DE61ON INTENT PRIOR TO COMMENCEMENT OF THE PROJECT <br />ZONE Q 8D RING SHANK NAILS AT 6' OC AT ALL EDGES <br />SD RING SHANK NAILS AT 12' OC INTERMEDIATE <br />80 RING SHANK NAILS AT 6" OC, 4 OC AT <br />ZONE ©© ROOF EDGES, RIDGE LINES, OR GABLE END WALL <br />NOTE, END JOINT& FOR SHEATHING SHALL BE <br />STAGGERED AND OCCUR OVER A FRAMING <br />MEMBER <br />ROOF SHEATHING NAILING DETAIL <br />NOT TO SCALE <br />THE CLIENT UNDER6TAND6 THAT T14E DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLES6, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT, THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />ELECTRICAL LEGEND <br />G.F.I. IIv <br />SWITCH GROUND FAULT <br />RECEPTACLE <br />IIO V <br />WP <br />110 v <br />WATERPROOF <br />OUTLET FLUORESCENT <br />IIOY LIGHT <br />CAN BE CEILING <br />FIXTURE <br />OR WALL (tYP) <br />D <br />ELECTRICAL FLAN 1/411 = 11 Oil <br />THE CONTRACTOR/OWNER WILL BE RESPONSIBLE FOR <br />DETERMINING IF EXISTING ELECTRICAL SERVICE CAN <br />HANDLE ADDITIONAL LOAD <br />IN ACCORDANCE WITH CHAPTER 411.003 (2) lU OF THE FLORIDA ADMINISTRATIVE CODE, <br />ELECTRICAL SYSTEMS SHALL BE DESIGNED BY THE REOPE GTIVE CONTRACTOR TO MEET <br />ALL APPLICABLE CODES. THE ELECTRICAL SYSTEMS DRAW N HERON ARE BASE UPON A <br />DESIGN PROVIDED BY THE OWNER TO ADDRE66 HI6/HER R EQUIREMENTS, <br />ALL ELECTRICAL OUTLETS IN GARAGE AND AT EXTERIOR LOCATIONS 6HALL BE WIRED <br />INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />CARBON MONOXIDE ALARM MUST BE INSTALL WITHIN 10'0 " OF EACH ROOM USED FOR <br />SLEEPING PURPOSE& WHEN BUILDING HAG A FOSSIL FUEL BURNING HEATER OR APPLIANCE, <br />A FIREPLACE OR AN ATTACHED GARAGE. <br />2x4 CROSS -BRACING 6 RIDGE <br />I 20'-0" MAX7 <br />I <br />W!, <br />Ulm <br />Avi <br />0 <br />INFEmy <br />Iffis <br />NEW <br />-no <br />m <br />pal, <br />IN <br />pm <br />Him <br />2 X 4 NAILERB TYP <br />TOP/BOTTOM CHORD GABLE <br />1END BRACING * 48" O.C. MAX <br />FOR THE FIRST 4 ROWS OF <br />TRUSSES (MIN 2X4 ) <br />SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADOTIONAL <br />BRACING OR CROSS BRACING REQUIREMENTS <br />REQ. MINIMUM TRUSS BRACING <br />J <br />cn <br />-4 <br />lei <br />CONT. BOTTOM CHORD <br />BRACING (1"x4" MIN.) <br />10'-0" MAX. <br />2 X 8 •2 YELLOW PINE <br />RIDGE BEAM TYP. <br />VERT SCAB <br />CONT, 2 X 4 NAILER TYP _ <br />2- I&D NAILS PER TRUSS <br />BEVEL CUT <br />TYP <br />-)n' All <br />-1- '---- ' --- --- --- --- ---- --- --- ---------------------------1 <br />ROOF TRUSS PLAN 1/4 _ 11 OII <br />USSES BELOW SHEATHED <br />.IOR TO VALLEY FRAMING <br />ITALLATION <br />6 02 YELLOW PINE <br />LEY FRAMING TYP. <br />COMMON TRUSS <br />2 X 8 02 YELLOW PINE <br />RIDGE BEAM TYP. <br />2 X 4 CONT <br />UPS RT3 OR 61MPWN <br />H3 HURR STRAP * 48" <br />OC TYP. <br />SIMPSON 43 FRAMING <br />ANCHOR TYP, <br />r- ROOF SHEATHING <br />UPS RT3 OR SIMPSON <br />N3 HURR STRAP 48" OC <br />TYP. <br />SECTION "A" - "A" <br />TYPICAL CONY FRAME VALLEY DETAIL <br />ALL CONNECTORS ON VALLEY FRAMING DETAIL <br />HAVE BEEN REVIEWED AND SIZED FOR COMBINE <br />UPLIFT, SHEAR AND LATERAL LOADS <br />2 X 4 VERTICAL SCAB * 48" Or - <br />MAX CONN. W/ 4 I&D NAILS <br />TOP 4 USP RT3 OR 6IMP60N H3 <br />HURR CLIP AT BOTTOM <br />ROOF VALLEY DETAIL <br />4- I&D TOE NAILS <br />RIDGE BOARD END <br />2 X 6 02 YELLOW PINE <br />�— RAFTER 0 24" Or - <br />UPS RT3 OR 6IMP60N <br />H3 14URR STRAP EACH <br />END <br />ARKAY ENGINEERING INC. <br />STIR RAL ENGINEERS <br />R9: BARD L. IDDE'1' .E. <br />FLORIDA LICENSE NUMBER 3T296 <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIO NS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER I6, SECTION 160E O F THE <br />FLORIDA BUILDING CODE 2001 FOR 120 MPH (3 SECOND GUST) <br />WIND ZONE - 100 MPH FASTEST SPEED AND THE ENTIRE 2001 <br />FLORIDA BUILDING CODE RESIDENTIAL AND 2009 SUPPLEMENTS <br />�y <br />o� <br />ZaMNQ <br />��,I� <br />C'3 a• M G QO <br />tAl <br />-CAAc <br />� Zi N- <br />N- <br />IK <br />�H�vW <br />O <br />r� <br />WCA <br />CA 0 <br />Z L � <br />�LL <br />ZZ Q� <br />:z <br />Lu <br />jp <br />LL-1 <br />Ld <br />11.3 <br />21 <br />h- <br />Q <br />_0 <br />}N <br />IJJ <br />I- <br />w <br />g <br />ID <br />O <br />u- <br />_ u <br />V <br />O <br />GARAGE <br />560 SQ. FT, <br />FIG <br />3of: 3 <br />ARKAY f 29 <br />