Laserfiche WebLink
FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />FIBEREGLASS SHINLGE INSTALLED <br />AS PER MANUFACTURER <br />SPECIFICATIONS <br />12 <br />5.01— <br />7 <br />---- --— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ---- <br />EXTERIOR <br />CJ PLASTER ON <br />FRAME <br />25-SH 25-SH 12 FLASHING <br />14.0 <br />- — — — — — — — — — — — — — — — — — — — — — — _ - — <br />---- -------------C--- <br />J/WEEP — — — — — — — — <br />35-SH <br />t----1-------------------------- L-J- <br />6068 SGD <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />REAR ELEVATION — A <br />SCALE: 1/4" = 1'-0" <br />9'-0" RIDGE VENT <br />FLASHING <br />12 12 <br />- — — — — q-�� CJ CJ —14.0 2i <br />- - <br />---------------------------------------------------------------- 1�1 ------------------------------------------------- <br />`t <br />1 H3-SH <br />----1--1 ---- J-1---------------------------------------------------- <br />t.......................................... I... F <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON <br />CMU (TYP) <br />LEFT ELEVATION — A <br />SCALE: 1 /4" = 1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.xl-1/2" long (3/4"A" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations, <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />e•1 <br />C%J <br />0 <br />u� o <br />N J y ;o <br />a- <br />'y <br />N Oi Q -N <br />Q a N Y <br />_d <br />>r_ <br />3 ev <br />4 <br />{o y ai 17 <br />� T <br />c <br />G E <br />en o <br />d u <br />0 <br />��N�>>>\\N11111 <br />1N N <br />:.�°` �?,O <br />E -lip <br />'_ <br />�l w <br />J <br />U \N1 <br />'r^ <br />' •• <br />FLO �` <br />V�-/Z QR 0 F E S S\ C) ``NN\'��� <br />��''Urll►I I I 11tt'�011 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />W <br />Wo <br />RCN <br />CD o <br />r • 0 <br />� M 0 <br />4 <br />LL ILL d <br />=" <br />Z m <br />gao� <br />W <br />W ��7 0 <br />07°' m <br />Z CD <br />1 C) Z ¢ J <br />— N <br />ILW O <br />Q <br />Z �� 5 8 <br />1313 <br />Z N <br />z <br />Q <br />c_- <br />U) tn z <br />•U a <br />0 <br />i_J <br />c � <br />Q <br />�0 <br />s�o <br />E <br />Qo <br />Ka <br />Wl= <br />o <br />o <br />0 <br />Z <br />Z <br />t� fd <br />L <br />az <br />KZ <br />'v <br />an <br />wo <br />Z <br />J <br />3 <br />Q ro <br />s <br />Z <br />Z 2 <br />0 <br />W <br />n <br />aZ <br />m <br />Mill!Z <br />M <br />�w <br />0 <br />0 <br />> Lo <br />CO Lr) <br />CO <br />.-. <br />:3 N o <br />0 <br />Cr . J <br />N <br />a, <br />m <br />N <br />I'— <br />O <br />Ln <br />_ <br />LL <br />O <br />r**.. <br />Y <br />CU <br />~ <br />m NO <br />Lb <br />N <br />N <br />T <br />a� <br />Z <br />k CD = <br />r <br />e <br />Z <br />M <br />Eo ` <br />JOB <br />NO: 23-00513 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.2 <br />