ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A1200A INDOOR <br />PANEL CENTER <br />#14 to lights 8 outlets <br />NEMA 1 01 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 #10 to WH <br />#e to Range <br />#6 to HVAC <br />:R <br />5o=vo <br />200=4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />4 Bare Cu Ground <br />INTERSYSTEM <br />BONDING <br />Q <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />7f WITH CODE APPROVED <br />NEC 17, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done In strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included In the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FqT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />FET-G <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />16) <br />EXHAUST FAN <br />Q <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />is <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS — <br />PER SPECS <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN <br />SCALE: Y4'=1'-0" <br />r -1 <br />�I ALT II <br />I I AC PAD I I <br />I� �I <br />t--- -- A <br />OPT. <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />------------------ <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />1.5" VTR 3" VTR III, <br />III, <br />—I I <br />I I <br />I I <br />I I <br />I I N, <br />3" VTR III— I �� <br />I \ I <br />I I I I I <br />3" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN -A <br />SCALE: Y4"=1'-0" <br />N <br />N <br />C <br />O <br />}O W <br />4t <br />u ai o <br />C A V (V <br />v m x <br />N CO C) a <br />f E W C1 <br />a; w <br />3 a)c <br />•� E � <br />W +_ 4 <br />� 3 R <br />es y w tt <br />� u w <br />mc o <br />eo <br />a <br />C E <br />�C5 <br />a� <br />d <br />N <br />O <br />N <br />O <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Resldentlal <br />7th EdItlon. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />Q <br />E <br />8 <br />y <br />O <br />Cb <br />m d C <br />to <br />Q <br />I.CT <br />(n 'T J <br />J <br />15 LU <br />CO <br />6LLL <br />Z <br />�� a <br />q <br />W <br />W <br />'o <br />coLL=�MZdJ <br />6 <br />ZN <br />O 6 <br />W <br />❑❑ <br />CD l2 N <br />� �uS <br />z o <br />J — <br />0. u7 <br />Q) <br />M <br />QD <br />uu-U C) <br />Ocl- <br />w 8 <br />N <br />IUL � <br />z <br />Q <br />Z <br />o ;= <br />Co ra <br />dQa, Z <br />� <br />w Z <br />C.0 <br />v <br />Z <br />iZ <br />Z <br />4b <br />W <br />s2 <br />zo <br />W <br />U3 <br />$ <br />�u <br />N <br />r <br />� <br />5�0 <br />�U '9 <br />L o <br />rn <br />M <br />L <br />d. <br />N <br />N <br />Cr <br />a <br />� <br />Q <br />8 <br />N <br />^^ <br />o <br />m <br />N <br />`. <br />�+ <br />0 <br />L0 <br />O <br />- M <br />O <br />(0 <br />m CD <br />a) <br />Lin <br />r <br />Q <br />co CV <br />M N <br />t'^' <br />1p <br />M <br />co <br />H r <br />Z <br />M <br />E <br />B :3 <br />v <br />c <br />a. <br />U <br />Q O <br />JOB <br />NO: <br />23-00513 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />