My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6404 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6404 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 8:14:04 PM
Creation date
2/19/2025 2:05:58 PM
Metadata
Fields
Template:
Building Plans
Street #
6404
Location
Cobble Bliss St
Contractor
Lennar Homes
Building Plans - Permit #
21539
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLASHING REQUIREMENTS <br />R609.1 General. This section prescribes performance and construction requirements for exterior <br />windows and doors installed in walls. Windows and doors shall be installed and flashed in accordance <br />with the fenestration manufacturer's written instructions. Window and door openings shall be flashed <br />in accordance with Section R703.4. Written installation instructions shall be provided by the <br />fenestration manufacturer for each window or door. <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved water -resistive barrier shall be applied <br />over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, with the <br />upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall <br />be lapped not less than 6 inches (152 mm). The felt or other approved material shall be continuous to <br />the top of walls and terminated at penetrations and building appendages in a manner to meet <br />the requirements of the exterior wall envelope as described in Section R703.1. The water -resistive <br />barrier is not required for detached accessory buildings. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner <br />to prevent entry of water into the wall cavity or penetration of water to the building structural framing <br />components. Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior <br />fenestration products shall be sealed at the juncture with the building wall with a sealant complying <br />with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the type of <br />sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion resistant flashings <br />shall be installed at the following locations: <br />CUT HOUSEWRAP AT <br />450 ANGLE <br />MODIFIED "I" CUT IN <br />HOUSEWRAP <br />LINE OF WINDOW <br />OPENING <br />APPROVED HOUSEW1 <br />SHEATHING OVER WI <br />INSTALL 4" WIDE <br />SELF -ADHERING <br />STRAIGHT FLASHIf <br />OVER NAILING FLA <br />AT JAM BS <br />EXTEND FLASHING <br />BELOW SILL FLEXI. <br />FLASHING & MIN 2 <br />THE HEAD <br />PORARILY <br />)-UP & SE( <br />ISEWRAP (I <br />K FLAP UN <br />i EAD <br />LD HOUSE <br />AT JAMBS <br />OPE SILL R <br />1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to <br />the surface of the exterior wall finish or to the water -resistive barrier complying with Section 703.2 for <br />subsequent drainage. Mechanically attached flexible flashings shall comply with AAMA 712. Flashing at <br />exterior window and door openings shall be installed in accordance with one or more of the following: <br />1. 1.1.The fenestration manufacturer's installation and flashing instructions, or for applications not <br />addressed in the fenestration manufacturer's instructions, in accordance with the flashing <br />manufacturer's instructions. Where flashing instructions or details are not provided, pan flashing shall <br />be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in <br />such a manner as to direct water to the surface of the exterior wall finish or to the water resistive <br />barrier for subsequent drainage. Openings using pan flashing shall incorporate flashing or protection <br />at the head and sides. <br />2. 1.2.In accordance with the flashing design or method of a registered design professional. <br />3. 1.3.In accordance with other approved methods. <br />4. 1.4.In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA <br />300 or FMA/AAMA/WDMA 400. <br />2. 2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />projecting lips on both sides under stucco copings. <br />3. 3.Under and at the ends of masonry, wood or metal copings and sills. <br />4. 4.Continuously above all projecting wood trim. <br />5. 5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />construction. <br />6. 6.At wall and roof intersections. <br />T 7.At built-in gutters. <br />INSTALL 4" <br />SELF-ADHER <br />FLASHING 0' <br />WINDOW FII <br />EXTEND SELI <br />FLASHING V <br />JAMB FLASH: <br />TYPICAL WINDOW FLASHING INSTALLATION DETAILS <br />4LIGN FLASHIN( <br />NI INT. EDGE 0 <br />SILL R.O. <br />MECHANICALLY <br />=ASTEN FANNEC <br />EDGES. (CAP NA <br />STAPLES) PER M <br />INSTRUCTIONS <br />INSTALL 6" WID <br />SELF -ADHERING <br />=LASHING AT SI <br />EXTEND FLEX FL <br />)OWN THE SILL <br />FOLD HOUSEWRAP <br />DOWN.CONSTRUCTI <br />TAPE ACROSS HEAD <br />WINDOW & THEN <br />DIAGONAL CUT <br />4. CONTINUOUS <br />I BACK OF WIND <br />E IN LINE W/ <br />TOLES OR SLOT <br />INSTALL WINE <br />PLUMB, LEVEL <br />SQUARE PER P <br />WRITTEN INS <br />NOTE: <br />1. WINDOW INSTALLATION AND FLASHING DETAILS ARE CONSISTENT <br />WITH ASTM E 2112 METHOD A-1 EXCEPT SELF -ADHERING <br />FLASHINGS ARE USED <br />2. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY THE <br />COMPATIBILITY OF ALL PRODUCTS INCLUDING HOUSEWRAP, <br />SEALANTS & SELF -ADHERING FLASHING MATERIALS USED DURING <br />CONSTRUCTION. <br />3. INSTALL ALL MATERIALS PER MANUFACTURER'S WRITTEN <br />SPECIFICATIONS <br />WARNING: SEALANTS/FLASHINGS MAY REACT ADVERSELY IF NOT <br />COMPATIBLE. <br />NOTE: <br />TYPICAL WINDOW & DOOR FLASHING <br />INSTALLATION DETAILS PREPARED IN <br />ACCORDANCE WITH FBC APPROVED <br />SPECIFICATIONS. <br />SEAL WINDOW FRAME TO <br />INSIDE OF R.O. W/ SEALANT AT <br />SILL AND A MIN 6" UP BOTH <br />JAMBS TO FORM A BACK DAM. <br />SEAL BALANCE OF FRAME WITH <br />SEALANT OR NON -EXPANDING <br />FOAM (PROVIDE BACKER ROD <br />WHERE REQUIRED) <br />•- SELF -ADHERING FLEXIBLE <br />FLASHING AT SILL, FLUSH <br />TO INTERIOR FRAMING. <br />INTERIOR VIEW <br />STEP 9 <br />NTS <br />r <br />DAVIS BEWS <br />DESIGN GROUP <br />150 STATE STREET EAST <br />OLDShiAR, FLURIDA 39677 <br />813.925.130o TEL <br />813 . 925.1800 FAX <br />W W W.DAVLSBEWS.COM <br />TAMI'A • DENVER <br />w-� EST. 1994 � <br />O <br />00 <br />'—' O <br />9.0 <br />cn M O <br />un n3 L^ <br />N O Ln <br />i LL <br />SZ <br />ZqC U Q CO <br />Z � � <br />W w0 <br />J O <br />d' <br />J <br />110 <br />0, <br />�U) <br />�s <br />�� <br />za <br />z� <br /><¢ <br />r F. <br />w ¢ °a a <br />0 <br />JLU <br />I�l -0zz <br />J <br />Ow�o <br />W C0z0 <br />oU) <br />Q zz <br />O <br />�z <br />w <br />z z a <br />0Lo <br />o U aJ <br />Q <br />Z <br />J LJJ <br />L LL f� <br />z � LLI <br />z <br />z U z Z O <br />0 <br />H <br />E LU z Z <br />O <br />Z Q LULL.I 0 <br />Z > = F--i <br />LU <br />O g LU � m <br />SCALE : AS NOTED <br />DATE : 10-19-2018 <br />VERSION NO. <br />i M 0 <br />SHEET NO. <br />DT5ml <br />