My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6548 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6548 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:32:57 PM
Creation date
2/19/2025 2:10:59 PM
Metadata
Fields
Template:
Building Plans
Street #
6548
Location
Gall Blvd
Contractor
3 D Construction Service
Building Plans - Permit #
7915
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br />P <br />r <br />1. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO SUBMITTING HIS <br />BID TO INVESTIGATE ACTUAL EXISTING CONDITIONS, AND CIRCUIT AVAILABILITY IN <br />EXISTING PANEL BOARD. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, <br />2, ALL KITCHEN 15 AND 20 AMP RECEPTACLES SHALL BE GFI TYPE. <br />3. ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE N.E.C. <br />AND LOCAL CODES. <br />SHEET GENERAL NOTES N.T.S. 1 3 1 <br />1O PROVIDE A 4" OCTAGONAL BOX FOR ANSUL FIRE SUPPRESSION SYSTEM PULL <br />STATION. VERIFY EXACT LOCATION OF JUNCTION BOX WITH EQUIPMENT <br />SUPPLIER PRIOR TO ROUGH -IN INSTALLATION, EXTEND A 1/2" EMPTY CONDUIT <br />UP TO ACCESSIBLE CEILING. SEE SHEET M2.0, CONNECT TO EXISTING FIRE <br />SUPPRESSION SYSTEM CIRCUIT. <br />O PROVIDE A 2"x4" J-BOX W/DOUBLE RJ-45 DATA JACKS. PROVIDE A SINGLE GANG <br />MUD RING AND COVER PLATE AS REQUIRED. PROVIDE 1" CONDUIT, WITH PULL <br />STRING TO ABOVE ACCESSIBLE CEILING. <br />O NOT USED, <br />O PROVIDE 120V, 1 P/20 AMP GFI RECEPTACLE FOR FRYER 18" A.F.F. PROVIDE <br />120V, 1 P/20 AMP CIRCUIT BREAKER WITH SHUNT TRIP IN EXISTING PANEL "B". <br />O PROVIDE 120V, 1 P/20 AMP DUPLEX RECEPTACLE. SEE DETAIL #2 SHEET E1.0. <br />O PROVIDE 120V, 1 P/20 AMP ISOLATED GROUND TYPE RECEPTACLE @ 36" A.F.F. <br />FOR PRINTER AND 84" FOR MONITOR. CONNECT TO EXISTING MONITOR CIRCUIT. <br />O NOT USED. <br />O PROVIDE 120V, 1 P/30 AMP NEMA-3R DISCONNECT ON ROOF FOR EXHAUST FAN. <br />SEE DETAIL #2 SHEET E1.0, PROVIDE 2P/20 AMP CIRCUIT BREAKER WITH SHUNT <br />TRIP IN EXISTING PANEL "B". VERIFY EXACT LOCATION OF FAN. <br />O PROVIDE (3)#12 AND (1)#12 GROUND IN 1/2" CONDUIT. <br />10 PROVIDE (2)#12 AND (1)#12 GROUND IN 1/2" CONDUIT, <br />11 SEE DETAIL #2 ON SHEET E1.0 FOR EXHAUST FAN/FRYER CONTROL DIAGRAM. <br />(�D MAKE CONNECTION TO LIGHTS IN HOOD FURNISHED WITH HOOD. <br />13 HOOD FIRE SUPPRESSION CONTROL PANEL (ELECTRICAL SWITCHES) PROVIDED <br />BY OTHERS, SEE ELEVATION ON SHEET M2.0 FOR EXACT LOCATION, <br />(�D PROVIDE 120V, 1 P/20 AMP RECEPTACLE, CONNECT TO EXISTING PANEL "B". <br />15 ELECTRICAL CONTRACTOR SHALL RECIRCUIT EXISTING COOLER AND FREEZER <br />LIGHTS FROM CIRCUIT B-38 TO B-36. <br />16 PROVIDE FLUSH MOUNTED CEILING RECEPTACLE AND J-BOX OUTLET FOR <br />NEW TV'S (3 - LOCATIONS). CONNECT TO 120V CIRCUIT IN PANEL "B". J-BOX IS FOR <br />CABLE T.V. IF REQUIRED BY LOCAL CODE. <br />17 E.C. TO EXTEND & REUSE EXISTING DEMOED ICE CONDENSER CIRCUIT TO <br />LOCATION OF NEW ROOF -TOP ICE MACHINE CONDENSER. VERIFY AND MAKE <br />FINAL CONNECTIONS. <br />(2D E.C. TO REUSE EXISTING DRINK DISPENSER CIRCUIT & OUTLET FOR NEW DRINK <br />DISPENSER/ICE MAKER. <br />SHEET KEYED NOTES N.T.S. 1 2 1 <br />CEILING LINE <br />EXISTING 300 AMP <br />SERVICE FEEDER. <br />BUILDING WALL, <br />LEASE LINE. <br />I <br />I <br />t fEXISTING (4)#350KC MIL AND <br />(1)#3 GROUND IN 3" CNDT. <br />CEILING LINE <br />EXISTING =, <br />t - <br />EXISTING <br />E EXISTING <br />EXISTING <br />CT/METER = <br />PANEL "B" <br />;PANEL 'A" <br />_ PANEL "C" <br />120/208V <br />120/208V <br />120/208V <br />30,4W E <br />30,4W ? <br />I 30AW <br />120/208V <br />300 AMP <br />E 200 AMP <br />I 200 AMP <br />30,4W <br />I M.C.B. <br />I <br />€ <br />400 AMP <br />E <br />N0 WORK i <br />NO WORK <br />t I ---A-EXISTING (4)#1/0 AND (1)#6 <br />t GROUND IN 2" CNDT. <br />EXISTING GROUND. <br />FINISH GRADE LINE EXTERIOR INTERIOR FINISH FLOOR LINE <br />ONE LINE DIAGRAM 1/4"=1'-0" 1 5 1 <br />04.24.08 HAND SINK ADDITION <br />CONTRACT DATE: <br />03.21.08 <br />BUILDING TYPE: <br />?????? <br />STORE NUMBER: <br />95343 <br />ARCV NUMBER: <br />080406 <br />6548 GALL BLVD. <br />ZEPHYRHILLS, FL 33542 <br />ELECTRICAL <br />FLOOR PLAN <br />E2,0 <br />ELECTRICAL FLOOR PLAN 1/4"=1'-0" '� PLOT DATE: <br />02.19.08 <br />�y <br />
The URL can be used to link to this page
Your browser does not support the video tag.