Laserfiche WebLink
120- <br />100- <br />80 <br />60 <br />40- <br />20-- <br />0] <br />a <br />PENTAIR EQ SERIES PERFORMANCE CURVE <br />EQ1000 <br />100 200 300 400 500 600 <br />FLOW RATE IN U.S. GPM <br />RECIRCULATION PUMP CURVE <br />__80 <br />70 <br />_-60 <br />- <br />-20 <br />r, <br />Z <br />­20 !!:! <br />y Ln co <br />z <br />uj <br />20 <br />10 <br />10 <br />700 <br />MARK <br />DESCRIPTION <br />VOLTAGE <br />MANUFACTURER & MODEL NO. <br />0 <br />MAIN LUG BREAKER PANEL <br />(24 CIRCUIT) <br />120/240V <br />SIEMENS, PW2442L3200CU <br />G) <br />RECIRCULATION PUMP <br />208-230/460V <br />PENTAIR, EQKT1000, 10 HIP <br />100 W SERVICE LIGHT FIXTURE <br />115V <br />INTERMATIC, VPXG11GCI 10OW <br />CHLORINE FEEDER PUMP <br />115V <br />STENNER, 8SM5 <br />ACID FEEDER PUMP <br />115V <br />STENNER, 45M5 <br />SERVICE GFICI <br />115V <br />PASS & SEYMOUR <br />CHEMISTRY CONTROLLER <br />115V <br />CES, MR3 <br />DECK JET PUMP <br />208-230/460V <br />SPECK, 9SX, 7.5 HP <br />BUBBLER PUMP <br />208-230/460V <br />PENTAIR, MAX-E-PRO XF VS, 5 HP <br />EXHAUSTFAN <br />115V <br />DAYTON 273 CFM <br />POOL LIGHTING (11) <br />115V <br />AMERITLITE, 10OW LED EQUIVALENT <br />POOL UGHTING TRANSFORMER (3) <br />115V <br />PENTAIR, PX300 30OW TRANSFORMER <br />CHLORO-SALINE GENERATOR <br />115V <br />CES, CHLORKING SM15.0 <br />FEATURE TIMER (2) <br />115-208/230V <br />INTERMATIC, T-101, 24 HIR MECH TIMER <br />ELECTRICAL SPECIFICATION PROVIDE BY <br />AQUAWORX USA <br />6 <br />42': <br />3111 <br />FIELD CAST 6" THICK, 2500 PSI <br />CONCRETE FOOTING UNDER <br />STEEL FRAME & COVER <br />FILTER EQUIPMENT CABINET <br />4,000 PSI CONCRETE <br />SAND FILTERS SET ON CONCRETE PAD <br />#3 REBAR @ 6" O.C.E.W. <br />6" THICK MIN. <br />SIDEWALL VENT <br />(TYP BOTH SIDES) <br />1" x 1" STEEL FRAME <br />FRAME ON BRICKS <br />AS NEEDED <br />(TYP OF 3) <br />SAND FILTER EQUIPMENT SCHEMATIC LAYOUT <br />FEEDER & CIRCUIT SCHEDULE: <br />CONDUCTORS <br />MARK <br />PHASE <br />NEUTRAL <br />GROUND <br />CONDUIT <br />REMARKS <br />PANEL FEED <br />A2 <br />348 <br />1-#8 <br />UL SEALTITE <br />A3 <br />3410 <br />1-#10 <br />1/2" <br />SEALTITE TO PANEL <br />1412 <br />1-#12 <br />1-#12 <br />1/2" <br />SEALTITE TO LIGHT <br />AS <br />1412 <br />1-#12 <br />1-#12 <br />1/2" <br />SEALTITE TO PANEL <br />6 <br />A <br />1412 <br />1-#12 <br />1-#12 <br />1/2" <br />SEALTITE TO PANEL <br />Z� <br />CONDUCTORS AND CONDUIT INSTALLED BY OTHERS <br />PANEL SCHEDULE: <br />THREE PHASE, 4-WIRE -- 208Y/120 VAC OR 240 VAC INSULATED/BONDABLE NEUTRAL <br />CURRENT WITHSTAND RATING MAX. RMS. SYM. 10,OOOA 12/240V <br />CIRCUIT <br />POLE <br />TRIP <br />LOAD <br />AMPS <br />1-3 <br />3 <br />SOAGFI <br />RECIRC. PUMP W/(2) INTERLOCKED CHEM. CONT <br />29.8 <br />4-6 <br />3 <br />50AGFI <br />DECKJETPUMP <br />19.9 <br />7-9 <br />3 <br />30A GFI <br />BUBBLER PUMP <br />13.8 <br />10 <br />1 <br />20A GFI <br />POOL LIGHT TRANSFORMER #1 <br />10.0 <br />11 <br />1 <br />20AGFI <br />POOL LIGHT TRANSFORMER #2 <br />10.0 <br />12 <br />1 <br />20AGFI <br />POOL LIGHT TRANSFORMER #3 <br />3.3 <br />13 <br />1 <br />20A GFI <br />CHLORO SALINE GENERATOR <br />7.5 <br />14 <br />1 <br />20A <br />SERVICE LIGHT <br />1.5 <br />15 <br />1 <br />20A <br />SERVICE GFCI <br />3.0 <br />16 <br />1 <br />20A <br />EXHAUST FAN <br />3.1 <br />17-24 <br />SPARE <br />TOTAL MAXIMUM LOAD <br />1 101.9 <br />FILTER EQUIPMENT CABINET <br />FRONT ELEVATION <br />117 <br />J4. 1====. <br />FILTER TANK <br />FRONT ELEVATION <br />7 <br />132" <br />6 0 1 <br />FILTER EQUIPMENT CABINET <br />PLAN <br />LABELED: LABELED: <br />"ACID' // "CHLORINE" <br />DECK JET PUMP <br />Ill FROM SALIN <br />6" FLOWMETER- 3" FROM HEATER <br />THERMOM ER- 6" DECK JET SUCTION <br />CHEMICAL INJECTION POINTS- - 3" TO HEATER <br />6" RECIRC RETURN TO POOL- V FROM SALINE <br />4" DECK JET RETURN - 6" RECIRC RETURN FROM FILTER PACK <br />100W SERVICE LIGHT I F BUBBLER PUMP <br />I <br />r ALT CHLORINE GENERATOR <br />71 <br />00 <br />ELECTRICAL PANEL--4 <br />. LJ : I IT7 N <br />u <br />SALT CHLORINE CONTROLLER <br />VFD <br />VFD <br />CHEMISTRY CONTROLLER <br />EXHAUSTFAN <br />CHLORINE FE EDER <br />6" RECIRC SUCTION <br />....... ... <br />PH FEEDER <br />3" BUBBLER RETURN <br />6" RECIRC RETURN TO FILTERS <br />RECIRC PUMP <br />- L 4" BUBBLER SUCTION <br />FILTER EQUIPMENT CABINET <br />PLAN <br />26 <br />51) <br />FII$tK E3KAIINU MUUNIEU <br />ALUMINUM RAILING <br />EQUIPMENTCOVER <br />EQUIPMENT COVER <br />SIDE ELEVATION <br />SIDE ELEVATION <br />BACKWASH SUMP DETAIL <br />VACUUM FILTER ELEMENTS <br />(TYP OF 5) <br />6" DECK JET PUMP SUCTION <br />41. <br />NOTES: <br />1. PLUMBING -ALL PIPE& FITTINGS SHALL BE SCHEDULE 40 PVC PER ASTM D1785 AND N.S.F. APPROVED AND STAMPED FOR <br />POTABLE WATER APPLICATIONS. JOINTS TO BE SOLVENT WELDED PER ASTM D2855. ALL PLUMBING AND MATERIALS TO CONFORM <br />TO FLORIDA BUILDING CODE 2020 -SEVENTH EDITION. <br />2. ELECTRICAL -ALL ELECTRICAL EQUIPMENT WIRING, INSTALLATION AND GROUNDING OF POOL COMPONENTS SHALL CONFORM TO <br />NATIONAL FIRE PROTECTION ASSOC. 70, NATIONAL ELECTRICAL CODE (N.E.C.) LATEST EDITION AND ALL APPLICABLE LOCAL CODES. <br />CHEMICAL FEED PUMPS TO BE INTERLOCKED WITH THE RECIRCULATION PUMP. <br />3. EQUIPMENT - ALL PUMPS, FILTERS AND DISINFECTION EQUIPMENT SHALL BE TESTED AND APPROVED BY THE PERTINENT <br />MANUFACTURER USING THE NSF/ANSI STANDARD 50 AND LISTED AS APPROVED BY THE NSF. <br />4. THE FILTER ROOM FLOOR IS SLIP RESISTANT AND SLOPED TO FLOOR DRAINS <br />5. ALL PLASTIC PIPING SUBJECT TO PROLONGED SUNLIGHT EXPOSURE MUST BE COATED TO PROTECT IT FROM ULTRAVIOLET <br />LIGHT DEGRADATION. <br />6. EACH WASTE LINE SHALL HAVE A UNIQUE AIR GAP. WASTE LINES FROM DIFFERENT SOURCES (E.G. POOL, SPA, OVERFLOW, <br />SUMP PUMP) SHALL NOT BE TIED TOGETHER BUT MAY DISCHARGE INTO A COMMON SUMP OR RECEPTACLE. <br />7. THE WASTE LINE MUST BE CONNECTED TO AN APPROVED WASTE DISPOSAL SYSTEM ACCORDING TO LOCAL OR STATE CODES. <br />8. ALL COLLECTOR TANKS SHALL HAVE COVED INTERSECTIONS AND SLOPE TO THE TANK DRAIN. <br />9. ANAUTOMATICAND MANUALWATER MAKEUP CONTROLMUSTBE PROVIDEDTO MAINTAINTHE WATER LEVELATTHE LIP OFTHE <br />OVERFLOW GUTTER OR AT THE MOUTH OFTHE RECESSED AUTOMATIC SKIMMERS AND MUST DISCHARGE THROUGH AN AIRGAP <br />INTOA FILL PIPEOR COLLECTORTANK. OVERTHE RIM FILLSPOUTSARE PROHIBITED. <br />10. A RATE OF FLOW INDICATOR, READING IN GPM, SHALL BE INSTALLED ON THE FILTER RETURN LINE. THE RATE OF FLOW <br />INDICATOR SHALL BE PROPERLY SIZED FOR THE DESIGN FLOW RATE AND SHALL BE CAPABLE OF MEASURING FROM ONE HALF TO <br />AT LEAST ONE -AND -ONE-HALF TIMES THE DESIGN FLOW RATE. THE CLEARANCES UPSTREAM AND DOWNSTREAM FROM THE <br />RATE OF FLOW INDICATOR SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION SPECIFICATIONS. <br />11. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE - SEVENTH EDITION <br />FILTER EQUIPMENT LIST <br />RECIRCULATION PUMP <br />PENTAIR EQKT1000, 10 HP WITH BASKET STRAINER, SELF -PRIMING, <br />515 GPM @ 60'TDH, 208-23OV, 30,26.4A <br />VFD (RECIRC) <br />CES, PFDX 10 HP VARIABLE FREQUENCY DRIVE <br />DECK JET PUMP <br />SPECK, 9SX, 7.5 HP WITH BASKET STRAINER, SELF -PRIMING, <br />250 GPM @ 60'TDH, 208-23OV, 30,19.9A <br />VFD (DECK JET) <br />CES, PFDX 7.5 HP VARIABLE FREQUENCY DRIVE <br />FILTER ELEMENTS (DECK JET) <br />UNICEL, ST155, 155 SQ FT EACH, 775 SQ FT TOTAL (290 GPM MAX) <br />BUBBLER PUMP <br />PENTAIR MAX-E-PRO XF VS, 5 HP WITH BASKET STRAINER, <br />SELF -PRIMING, 150 GPM @ 60- TDH, 208-23OV, 30,13.9A <br />FILTER TANK <br />AT1100, 1100 GALLON CAPACITY <br />SAND FILTER (3) <br />43" VERTICAL SAND FILTER, 12.15 SQ. FT., 3b.45 SQ. FT. T07A17— <br />547 GPM FILTRATION CAPACITY <br />WATER LEVEL CONTROL <br />AQUATEK HYDRAULIC VALVE W/ MANUAL FILLVALVE & RESERVOIR <br />CHLORINE FEEDER <br />STENNER 85MS, 85 GPD CAPACITY, 11OV, IJA <br />CHLORINE RESERVOIR TANK <br />65 GALLON WITH LOCKABLE LID <br />PH FEEDER <br />STENNER 4SMS, 50 GPD CAPACITY, 11OV, 1.7A <br />PH RESERVOIR TANK <br />30 GALLON WITH LOCKABLE LID <br />RECIRC FLOWMETER <br />6" BLUE/WHITE F-30600P, 170 TO 1100 GPM RANGE <br />THERMOMETER <br />PRECISION INSTRUMENT CO B2B1-K WITH 1/2" NPT THERMOWELL <br />30* TO 2407 RANGE <br />VACUUM GAUGE <br />WIKA, 0-30 IN HG, LIQUID FILLED, 1/4" NPT, 2" FACE DIAMET R <br />CHEMISTRY CONTROLLER <br />CES, MR3, CHEMISTRY CONTROLLER WITH SALINE COMPATIBILITY <br />CHLORO-SALINE GENERATORI <br />CES, CHLORKING SM15.0, 15 LBS PER DAY 115V <br />6" RECIRC SUCTION <br />8" FEATURE DRAIN J <br />10" GUTTER DRAIN <br />PIPE AND VALVES CHART <br />LINE FUNCTION <br />SIZE <br />MAIN DRAIN <br />101, <br />GUTTER DRAIN <br />10.1 <br />FEATURE DRAIN <br />81, <br />STATIC LINE <br />2" <br />FRESH WATER FILL <br />1.1 <br />OVERFLOW <br />3" <br />RECIRCULATION PUMP SUCTION <br />6" <br />RECIRCULATION RETURN TO FILTERS <br />6" <br />RECIRCULATION RETURN <br />6" <br />DECK JET PUMP SUCTION <br />6" <br />DECK JET RETURN <br />4" <br />BUBBLER PUMP SUCTION <br />4" <br />BUBBLER RETURN <br />3" <br />TO SALINE <br />11. <br />FROM SALINE <br />V. <br />BACKWASH LINE (3) <br />T' <br />DIA. POOL MAINTENANCE LINE <br />RAVEL FLOOR <br />MAINTENANCE DRAIN LINE TO STORM <br />DRAINAGE SYSTEM- VIA AIR GAP (REFER TO <br />PLUMBING DRAWINGS FOR CONTINUATION <br />OF PIPE) <br />4" BUBBLER PUMP SUCTION <br />MAIN DRAIN <br />1" AUTOFILL <br />2" LEVEL CONTROL <br />2" OVERFLOW WITH <br />CHECK VALVE <br />b <br />J <br />cd <br />0 <br />LL. <br />uj <br />0 <br />2 Lo <br />0 OD <br />Q <br />u <br />(>1 <br />r__1 <br />< <br />uj <br />co <br />*_0 <br />-q- <br />(y) <br />< <br />0 <br />ob <br />I <br />0 <br />< <br />r,4 <br />I- <br />w <br />0 <br />Z <br />0 <br />1 <br />LL_ <br />> <br />@) <br />0 <br />o" <br />< <br />LL. <br />LU <br />< <br />uj <br />< <br />Z <br />F-- <br />I <br />< <br />C) <br />< <br />_j <br />< <br />u <br />0 <br />cy) <br />Lij <br />J <br />0 <br />0 <br />IL <br />2 <br />Ld <br />Lo <br />z <br />w <br />0 6 <br />M X <br />uj <br />N <br />U) <br />J <br />uj <br />z <br />w <br />J <br />0 <br />0 <br />IL <br />REV. DESCRIPTION DATE <br />PERMIT SET 12-10-2021 <br />DRAWN ICHECKED <br />zio IRM <br />DATE SCALE <br />12-17-2021 <br />SHEET OF 121 <br />FILTER TANK <br />SIDE ELEVATION <br />FILTER TANK <br />COMPONENTS ID - PLAN <br />FILTER TANK <br />COMPONENTS ID - PLAN <br />PE-1 I <br />