<br />PENTAIR EQ SERIES PERFORMANCE CURVE
<br />EQ1000
<br />100 200 300 400 500 600
<br />FLOW RATE IN U.S. GPM
<br />RECIRCULATION PUMP CURVE
<br />__80
<br />70
<br />_-60
<br />-
<br />-20
<br />r,
<br />Z
<br />20 !!:!
<br />y Ln co
<br />z
<br />uj
<br />20
<br />10
<br />10
<br />700
<br />MARK
<br />DESCRIPTION
<br />VOLTAGE
<br />MANUFACTURER & MODEL NO.
<br />0
<br />MAIN LUG BREAKER PANEL
<br />(24 CIRCUIT)
<br />120/240V
<br />SIEMENS, PW2442L3200CU
<br />G)
<br />RECIRCULATION PUMP
<br />208-230/460V
<br />PENTAIR, EQKT1000, 10 HIP
<br />100 W SERVICE LIGHT FIXTURE
<br />115V
<br />INTERMATIC, VPXG11GCI 10OW
<br />CHLORINE FEEDER PUMP
<br />115V
<br />STENNER, 8SM5
<br />ACID FEEDER PUMP
<br />115V
<br />STENNER, 45M5
<br />SERVICE GFICI
<br />115V
<br />PASS & SEYMOUR
<br />CHEMISTRY CONTROLLER
<br />115V
<br />CES, MR3
<br />DECK JET PUMP
<br />208-230/460V
<br />SPECK, 9SX, 7.5 HP
<br />BUBBLER PUMP
<br />208-230/460V
<br />PENTAIR, MAX-E-PRO XF VS, 5 HP
<br />EXHAUSTFAN
<br />115V
<br />DAYTON 273 CFM
<br />POOL LIGHTING (11)
<br />115V
<br />AMERITLITE, 10OW LED EQUIVALENT
<br />POOL UGHTING TRANSFORMER (3)
<br />115V
<br />PENTAIR, PX300 30OW TRANSFORMER
<br />CHLORO-SALINE GENERATOR
<br />115V
<br />CES, CHLORKING SM15.0
<br />FEATURE TIMER (2)
<br />115-208/230V
<br />INTERMATIC, T-101, 24 HIR MECH TIMER
<br />ELECTRICAL SPECIFICATION PROVIDE BY
<br />AQUAWORX USA
<br />6
<br />42':
<br />3111
<br />FIELD CAST 6" THICK, 2500 PSI
<br />CONCRETE FOOTING UNDER
<br />STEEL FRAME & COVER
<br />FILTER EQUIPMENT CABINET
<br />4,000 PSI CONCRETE
<br />SAND FILTERS SET ON CONCRETE PAD
<br />#3 REBAR @ 6" O.C.E.W.
<br />6" THICK MIN.
<br />SIDEWALL VENT
<br />(TYP BOTH SIDES)
<br />1" x 1" STEEL FRAME
<br />FRAME ON BRICKS
<br />AS NEEDED
<br />(TYP OF 3)
<br />SAND FILTER EQUIPMENT SCHEMATIC LAYOUT
<br />FEEDER & CIRCUIT SCHEDULE:
<br />CONDUCTORS
<br />MARK
<br />PHASE
<br />NEUTRAL
<br />GROUND
<br />CONDUIT
<br />REMARKS
<br />PANEL FEED
<br />A2
<br />348
<br />1-#8
<br />UL SEALTITE
<br />A3
<br />3410
<br />1-#10
<br />1/2"
<br />SEALTITE TO PANEL
<br />1412
<br />1-#12
<br />1-#12
<br />1/2"
<br />SEALTITE TO LIGHT
<br />AS
<br />1412
<br />1-#12
<br />1-#12
<br />1/2"
<br />SEALTITE TO PANEL
<br />6
<br />A
<br />1412
<br />1-#12
<br />1-#12
<br />1/2"
<br />SEALTITE TO PANEL
<br />Z�
<br />CONDUCTORS AND CONDUIT INSTALLED BY OTHERS
<br />PANEL SCHEDULE:
<br />THREE PHASE, 4-WIRE -- 208Y/120 VAC OR 240 VAC INSULATED/BONDABLE NEUTRAL
<br />CURRENT WITHSTAND RATING MAX. RMS. SYM. 10,OOOA 12/240V
<br />CIRCUIT
<br />POLE
<br />TRIP
<br />LOAD
<br />AMPS
<br />1-3
<br />3
<br />SOAGFI
<br />RECIRC. PUMP W/(2) INTERLOCKED CHEM. CONT
<br />29.8
<br />4-6
<br />3
<br />50AGFI
<br />DECKJETPUMP
<br />19.9
<br />7-9
<br />3
<br />30A GFI
<br />BUBBLER PUMP
<br />13.8
<br />10
<br />1
<br />20A GFI
<br />POOL LIGHT TRANSFORMER #1
<br />10.0
<br />11
<br />1
<br />20AGFI
<br />POOL LIGHT TRANSFORMER #2
<br />10.0
<br />12
<br />1
<br />20AGFI
<br />POOL LIGHT TRANSFORMER #3
<br />3.3
<br />13
<br />1
<br />20A GFI
<br />CHLORO SALINE GENERATOR
<br />7.5
<br />14
<br />1
<br />20A
<br />SERVICE LIGHT
<br />1.5
<br />15
<br />1
<br />20A
<br />SERVICE GFCI
<br />3.0
<br />16
<br />1
<br />20A
<br />EXHAUST FAN
<br />3.1
<br />17-24
<br />SPARE
<br />TOTAL MAXIMUM LOAD
<br />1 101.9
<br />FILTER EQUIPMENT CABINET
<br />FRONT ELEVATION
<br />117
<br />J4. 1====.
<br />FILTER TANK
<br />FRONT ELEVATION
<br />7
<br />132"
<br />6 0 1
<br />FILTER EQUIPMENT CABINET
<br />PLAN
<br />LABELED: LABELED:
<br />"ACID' // "CHLORINE"
<br />DECK JET PUMP
<br />Ill FROM SALIN
<br />6" FLOWMETER- 3" FROM HEATER
<br />THERMOM ER- 6" DECK JET SUCTION
<br />CHEMICAL INJECTION POINTS- - 3" TO HEATER
<br />6" RECIRC RETURN TO POOL- V FROM SALINE
<br />4" DECK JET RETURN - 6" RECIRC RETURN FROM FILTER PACK
<br />100W SERVICE LIGHT I F BUBBLER PUMP
<br />I
<br />r ALT CHLORINE GENERATOR
<br />71
<br />00
<br />ELECTRICAL PANEL--4
<br />. LJ : I IT7 N
<br />u
<br />SALT CHLORINE CONTROLLER
<br />VFD
<br />VFD
<br />CHEMISTRY CONTROLLER
<br />EXHAUSTFAN
<br />CHLORINE FE EDER
<br />6" RECIRC SUCTION
<br />....... ...
<br />PH FEEDER
<br />3" BUBBLER RETURN
<br />6" RECIRC RETURN TO FILTERS
<br />RECIRC PUMP
<br />- L 4" BUBBLER SUCTION
<br />FILTER EQUIPMENT CABINET
<br />PLAN
<br />26
<br />51)
<br />FII$tK E3KAIINU MUUNIEU
<br />ALUMINUM RAILING
<br />EQUIPMENTCOVER
<br />EQUIPMENT COVER
<br />SIDE ELEVATION
<br />SIDE ELEVATION
<br />BACKWASH SUMP DETAIL
<br />VACUUM FILTER ELEMENTS
<br />(TYP OF 5)
<br />6" DECK JET PUMP SUCTION
<br />41.
<br />NOTES:
<br />1. PLUMBING -ALL PIPE& FITTINGS SHALL BE SCHEDULE 40 PVC PER ASTM D1785 AND N.S.F. APPROVED AND STAMPED FOR
<br />POTABLE WATER APPLICATIONS. JOINTS TO BE SOLVENT WELDED PER ASTM D2855. ALL PLUMBING AND MATERIALS TO CONFORM
<br />TO FLORIDA BUILDING CODE 2020 -SEVENTH EDITION.
<br />2. ELECTRICAL -ALL ELECTRICAL EQUIPMENT WIRING, INSTALLATION AND GROUNDING OF POOL COMPONENTS SHALL CONFORM TO
<br />NATIONAL FIRE PROTECTION ASSOC. 70, NATIONAL ELECTRICAL CODE (N.E.C.) LATEST EDITION AND ALL APPLICABLE LOCAL CODES.
<br />CHEMICAL FEED PUMPS TO BE INTERLOCKED WITH THE RECIRCULATION PUMP.
<br />3. EQUIPMENT - ALL PUMPS, FILTERS AND DISINFECTION EQUIPMENT SHALL BE TESTED AND APPROVED BY THE PERTINENT
<br />MANUFACTURER USING THE NSF/ANSI STANDARD 50 AND LISTED AS APPROVED BY THE NSF.
<br />4. THE FILTER ROOM FLOOR IS SLIP RESISTANT AND SLOPED TO FLOOR DRAINS
<br />5. ALL PLASTIC PIPING SUBJECT TO PROLONGED SUNLIGHT EXPOSURE MUST BE COATED TO PROTECT IT FROM ULTRAVIOLET
<br />LIGHT DEGRADATION.
<br />6. EACH WASTE LINE SHALL HAVE A UNIQUE AIR GAP. WASTE LINES FROM DIFFERENT SOURCES (E.G. POOL, SPA, OVERFLOW,
<br />SUMP PUMP) SHALL NOT BE TIED TOGETHER BUT MAY DISCHARGE INTO A COMMON SUMP OR RECEPTACLE.
<br />7. THE WASTE LINE MUST BE CONNECTED TO AN APPROVED WASTE DISPOSAL SYSTEM ACCORDING TO LOCAL OR STATE CODES.
<br />8. ALL COLLECTOR TANKS SHALL HAVE COVED INTERSECTIONS AND SLOPE TO THE TANK DRAIN.
<br />9. ANAUTOMATICAND MANUALWATER MAKEUP CONTROLMUSTBE PROVIDEDTO MAINTAINTHE WATER LEVELATTHE LIP OFTHE
<br />OVERFLOW GUTTER OR AT THE MOUTH OFTHE RECESSED AUTOMATIC SKIMMERS AND MUST DISCHARGE THROUGH AN AIRGAP
<br />INTOA FILL PIPEOR COLLECTORTANK. OVERTHE RIM FILLSPOUTSARE PROHIBITED.
<br />10. A RATE OF FLOW INDICATOR, READING IN GPM, SHALL BE INSTALLED ON THE FILTER RETURN LINE. THE RATE OF FLOW
<br />INDICATOR SHALL BE PROPERLY SIZED FOR THE DESIGN FLOW RATE AND SHALL BE CAPABLE OF MEASURING FROM ONE HALF TO
<br />AT LEAST ONE -AND -ONE-HALF TIMES THE DESIGN FLOW RATE. THE CLEARANCES UPSTREAM AND DOWNSTREAM FROM THE
<br />RATE OF FLOW INDICATOR SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION SPECIFICATIONS.
<br />11. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE - SEVENTH EDITION
<br />FILTER EQUIPMENT LIST
<br />RECIRCULATION PUMP
<br />PENTAIR EQKT1000, 10 HP WITH BASKET STRAINER, SELF -PRIMING,
<br />515 GPM @ 60'TDH, 208-23OV, 30,26.4A
<br />VFD (RECIRC)
<br />CES, PFDX 10 HP VARIABLE FREQUENCY DRIVE
<br />DECK JET PUMP
<br />SPECK, 9SX, 7.5 HP WITH BASKET STRAINER, SELF -PRIMING,
<br />250 GPM @ 60'TDH, 208-23OV, 30,19.9A
<br />VFD (DECK JET)
<br />CES, PFDX 7.5 HP VARIABLE FREQUENCY DRIVE
<br />FILTER ELEMENTS (DECK JET)
<br />UNICEL, ST155, 155 SQ FT EACH, 775 SQ FT TOTAL (290 GPM MAX)
<br />BUBBLER PUMP
<br />PENTAIR MAX-E-PRO XF VS, 5 HP WITH BASKET STRAINER,
<br />SELF -PRIMING, 150 GPM @ 60- TDH, 208-23OV, 30,13.9A
<br />FILTER TANK
<br />AT1100, 1100 GALLON CAPACITY
<br />SAND FILTER (3)
<br />43" VERTICAL SAND FILTER, 12.15 SQ. FT., 3b.45 SQ. FT. T07A17—
<br />547 GPM FILTRATION CAPACITY
<br />WATER LEVEL CONTROL
<br />AQUATEK HYDRAULIC VALVE W/ MANUAL FILLVALVE & RESERVOIR
<br />CHLORINE FEEDER
<br />STENNER 85MS, 85 GPD CAPACITY, 11OV, IJA
<br />CHLORINE RESERVOIR TANK
<br />65 GALLON WITH LOCKABLE LID
<br />PH FEEDER
<br />STENNER 4SMS, 50 GPD CAPACITY, 11OV, 1.7A
<br />PH RESERVOIR TANK
<br />30 GALLON WITH LOCKABLE LID
<br />RECIRC FLOWMETER
<br />6" BLUE/WHITE F-30600P, 170 TO 1100 GPM RANGE
<br />THERMOMETER
<br />PRECISION INSTRUMENT CO B2B1-K WITH 1/2" NPT THERMOWELL
<br />30* TO 2407 RANGE
<br />VACUUM GAUGE
<br />WIKA, 0-30 IN HG, LIQUID FILLED, 1/4" NPT, 2" FACE DIAMET R
<br />CHEMISTRY CONTROLLER
<br />CES, MR3, CHEMISTRY CONTROLLER WITH SALINE COMPATIBILITY
<br />CHLORO-SALINE GENERATORI
<br />CES, CHLORKING SM15.0, 15 LBS PER DAY 115V
<br />6" RECIRC SUCTION
<br />8" FEATURE DRAIN J
<br />10" GUTTER DRAIN
<br />PIPE AND VALVES CHART
<br />LINE FUNCTION
<br />SIZE
<br />MAIN DRAIN
<br />101,
<br />GUTTER DRAIN
<br />10.1
<br />FEATURE DRAIN
<br />81,
<br />STATIC LINE
<br />2"
<br />FRESH WATER FILL
<br />1.1
<br />OVERFLOW
<br />3"
<br />RECIRCULATION PUMP SUCTION
<br />6"
<br />RECIRCULATION RETURN TO FILTERS
<br />6"
<br />RECIRCULATION RETURN
<br />6"
<br />DECK JET PUMP SUCTION
<br />6"
<br />DECK JET RETURN
<br />4"
<br />BUBBLER PUMP SUCTION
<br />4"
<br />BUBBLER RETURN
<br />3"
<br />TO SALINE
<br />11.
<br />FROM SALINE
<br />V.
<br />BACKWASH LINE (3)
<br />T'
<br />DIA. POOL MAINTENANCE LINE
<br />RAVEL FLOOR
<br />MAINTENANCE DRAIN LINE TO STORM
<br />DRAINAGE SYSTEM- VIA AIR GAP (REFER TO
<br />PLUMBING DRAWINGS FOR CONTINUATION
<br />OF PIPE)
<br />4" BUBBLER PUMP SUCTION
<br />MAIN DRAIN
<br />1" AUTOFILL
<br />2" LEVEL CONTROL
<br />2" OVERFLOW WITH
<br />CHECK VALVE
<br />b
<br />J
<br />cd
<br />0
<br />LL.
<br />uj
<br />0
<br />2 Lo
<br />0 OD
<br />Q
<br />u
<br />(>1
<br />r__1
<br /><
<br />uj
<br />co
<br />*_0
<br />-q-
<br />(y)
<br /><
<br />0
<br />ob
<br />I
<br />0
<br /><
<br />r,4
<br />I-
<br />w
<br />0
<br />Z
<br />0
<br />1
<br />LL_
<br />>
<br />@)
<br />0
<br />o"
<br /><
<br />LL.
<br />LU
<br /><
<br />uj
<br /><
<br />Z
<br />F--
<br />I
<br /><
<br />C)
<br /><
<br />_j
<br /><
<br />u
<br />0
<br />cy)
<br />Lij
<br />J
<br />0
<br />0
<br />IL
<br />2
<br />Ld
<br />Lo
<br />z
<br />w
<br />0 6
<br />M X
<br />uj
<br />N
<br />U)
<br />J
<br />uj
<br />z
<br />w
<br />J
<br />0
<br />0
<br />IL
<br />REV. DESCRIPTION DATE
<br />PERMIT SET 12-10-2021
<br />DRAWN ICHECKED
<br />zio IRM
<br />DATE SCALE
<br />12-17-2021
<br />SHEET OF 121
<br />FILTER TANK
<br />SIDE ELEVATION
<br />FILTER TANK
<br />COMPONENTS ID - PLAN
<br />FILTER TANK
<br />COMPONENTS ID - PLAN
<br />PE-1 I
<br />
|