My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6598 Bar S Bar Trl (4)
Zephyrhills
>
Building Department
>
Building Plans
>
6598 Bar S Bar Trl (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:35:15 PM
Creation date
2/19/2025 2:12:30 PM
Metadata
Fields
Template:
Building Plans
Street #
6598
Location
Bar S Bar Trl
Contractor
Windward Building
Building Plans - Permit #
3410
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pentair vhdw <br />a% 0 , <br />Intel I i io n4I.,,2.�'5 g <br />Underwater Pool <br />Color -Changing LED Light <br />Installation and User's Guide <br />IMPORTANT SAFETY INSTRUCTIONS <br />READ AND FOLLOW ALL INSTRUCTIONS <br />SAVE THESE INSTRUCTIONS <br />Pool Light Specifications 1 of 3_ <br />Obtained from manufacturer - Pentair <br />14 <br />8 <br />1 . Feed cord through conduit to Junction Box, leaving at least tour (4) <br />feet of cord at the light fixture to coil around the light; see Figure I . on <br />page 7. The four (4) feet of cord around the light allows the light to be <br />ser%nced after the pool is filled with water. <br />2. Cut the cord at the Junction Box, leaving at least six (6) inches of <br />cord to make connections. <br />3. Strip back six (6) inches of the outer cord jacket to expose the three <br />insulated wires (be careful not to damage the insulation on the three <br />(3) inner wires.). <br />4� Connect all three (3) wires to the corresponding circuit wires in the <br />Junction Box and secure the Junction Box cover in place. <br />Mmprw� --- it the light is not submerged in water and powered on for <br />more than 10 minutes, the light will switch off for a cooling down period of <br />10 minutes then power back on. This circuitry protects the light from being <br />potential damage. <br />5. Install the IntelliBrite light assembly into the niche <br />and tighten the special bronze pilot screw (see <br />Figure 1. on page 7. <br />1�� Use only the special pilot screw <br />provided with this underwater light. This screw mounts <br />and electrically grounds the housing securely to the <br />mounting ring and wet niche Failure to use the screw <br />provided could create an electrical hazard which could <br />result in death or serious injury to pool users, installers or <br />others due to electrical shock. <br />Pilot screw <br />(brass) <br />6. Fill the pool until the underwater light is completely submerged in <br />water before operating the light for more than ten (10) seconds. <br />T Final check for proper light operation: To check for proper <br />operation, switch on the main switch or circuit breaker. and the switch <br />that operates the IntelliBrile underwater light itself. The light should <br />illuminate when power is applied. If not recheck the installation steps <br />starting with Step 1. <br />Intelli Bi ite' 5g Pool LED Light hi�iallation and User's Guide <br />Pool Light Specifications 2 of 3. <br />Obtained from manufacturer - Penfair <br />Pool Bonding Plan <br />Scale: Not to scale <br />To GF0, QrcW <br />Breakler u4 — <br />Pmw Swrce. <br />Figure 1. <br />FVd — <br />C*rKwft <br />4'min. <br />#8 AWG Ground <br />Connector bonding <br />is located at rear <br />of niche, <br />484 <br />min. <br />8' min. Junction Box or Low <br />Voltage Transformer, to the <br />max, water level of the pool. <br />rrdn. to top of Lens. <br />Concrete must be cut <br />back around niche to <br />allow for a compacted <br />plaster seal. <br />Coil 4 ft of light <br />cable arixind fbdure. <br />Pool Light Specifications 3 of 3 <br />Obtained from manufacturer - Pentair <br />Z <br /># 8 <br />WIF <br />NOTE: ALL METAL LOCATED WITHIN <br />5 FEET OF POOL WATER SHALL BE <br />BONDED. <br />NOTE: JUNCTION BOXES TO BE LOCATED ALONG <br />THE EDGE OF DECK AND 12" ABOVE COPING <br />WEDGE <br />ANCHOR <br />HANDICAPPED LIF] W1 GROUNDING <br />(Zr-PF\A1 <br />/S LADDER <br />,ND/OR HANDRAIL <br />Pool Bondi ail <br />Scale: Not to scale <br />BONDING NOTES <br />THE BONDING GRID MUST COMPLY WITH EITHER (A) OR (B) AND BE ATTACHED TO THE <br />CONDUCTIVE POOL REINFORCING STEEL AT A MINIMUM OF FOUR POINTS UNIFORMLY SPACED <br />AROUND THE PERIMETER OF THE ALLS OF A POOL, OUTDOOR SPA OR OUTDOOR HOT TUB. <br />ALTERNATE MEANS <br />WHERE STRUCTURAL REINFORCING STEEL IS NOT AVAILABLE OR IS ENCAPSULATED IN A <br />NONCONDUCTIVE COMPOUNT, A COPPER CONDUCTOR(S) SHALL BE UTILIZED WHERE THE <br />FOLLOWING REQUIREMENTS ARE MET. <br />• AT LEAST ONE MINIMUM 8 AWG BARE SOLID COPPER CONDUCTOR SHALL BE PROVIDED. <br />• THE CONDUCTORS SHALL FOLLOW THE CONTOUR OF THE PERIMETER SURFACE. <br />• ONLY LISTED SPLICES SHALL BE PERMITTED (SPLIT -BOLTS) <br />• THE REQUIRED CONDUCTOR SHALL BE 450-600 MM (18"-24") FROM THE INSIDE WALLS OF THE <br />POOL. <br />• THE REQUIRED CONDUCTOR SHALL BE SECURED WITHIN OR UNDER THE PERIMETER SURFACE <br />100 MM TO 150 MM (4" TO 6") BELOW THE SUBGRADE. CONNECT THIS SINGLE 8 AVVG <br />COPPER WIRED WITH SPLIT BOLTS ON THE COPPER "WHIPS'' LOCATED AT FOUR EQUAL POINTS <br />OF THE POOL. <br />0 <br />N <br />0 <br />U <br />U <br />d <br />_J <br />CL <br />M <br />CZ5 <br />Q <br />0 <br />0 <br />L <br />0 <br />LL_ <br />Ld <br />W <br />r <br />0 <br />M <br />M <br />cq <br />0 <br />_J <br />_J <br />LLI <br />Lo <br />0 00 <br />T_ <br />U <br />11� <br />T <br />(y) <br />— <br />or) <br />cy) <br />< <br />00 <br />(D <br />-T <br />CN <br />Z <br />LU <br />o <br />4- <br />(y) <br />C <br />0 <br />4- <br />00 <br />N <br />0 <br />a— <br />0 <br />Z <br />0 <br />> <br />C'4 <br />0 <br />= <br />F__ <br />=) <br />< <br />U_ <br />LU <br />U <br />, <br />LU <br />F-- <br />< <br />Z <br />LU <br />I <br />_J <br />C:) <br />0(-) <br />C0 <br />Q.,� <br />< <br />0 <br />CD <br />(y) <br />LLJ <br />A <br />.J <br />0 <br />0 <br />IL <br />0 <br />Z <br />U) <br />Z <br />Ld <br />0 <br />X <br />Ld <br />N <br />Z <br />J <br />Z <br />Q <br />Z <br />0 <br />M <br />_J <br />0 <br />0 <br />a. <br />REV. � DESCRIPTION I DATE <br />PERMITSET 1 12-10-202 1 <br />DRAWN CHECKED <br />Z-10 RMT <br />DATE SCALE <br />12-17-2021 <br />1 SHEET 12 OF 121 <br />PE-12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.