ABBREVIATIONS
<br />ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />A/AMP AMPERE
<br />AC ALTERNATING CURRENT
<br />ADA AMERICAN WITH DISABILITIES ACT
<br />AF AMPERE FRAME
<br />AFF ABOVE FINISHED FLOOR
<br />AHJ AUTHORITY HAVING JURISDICTION
<br />AIC AMPERE INTERRUPTING CAPACITY
<br />AL ALUMINUM
<br />AT AMPERE TRIP
<br />ATS AUTOMATIC TRANSFER SWITCH
<br />AWG AMERICAN WIRE GAUGE
<br />AV AUDIO VISUAL
<br />BFG BELOW FINISHED GRADE
<br />BOF BOTTOM OF FIXTURE
<br />C CONDUIT
<br />CA CABLE
<br />CAT CATALOG
<br />CATV CABLE TELEVISION
<br />CB CIRCUIT BREAKER
<br />CBA COLOR BY ARCHITECT
<br />CD CANDELA
<br />CKT CIRCUITS
<br />CU COPPER
<br />dB DECIBEL
<br />DC DIRECT CURRENT
<br />DN DOWN
<br />DWG DRAWING
<br />EC ELECTRICAL CONTRACTOR
<br />ETR EXISTING TO REMAIN
<br />F FAHRENHEIT
<br />FA FIRE ALARM
<br />FACP FIRE ALARM CONTROL PANEL
<br />FBA FINISH BY ARCHITECT
<br />FLA FULL LOAD AMPERES
<br />G GROUND
<br />GEC GROUNDING ELECTRODE CONDUCTOR
<br />GFCI GROUND FAULT CIRCUIT INTERRUPTER
<br />GND GROUND
<br />HP HORSEPOWER
<br />HVAC HEATING, VENTILATION, AND AIR
<br />CONDITIONING
<br />IG ISOLATED GROUND
<br />KVA KILOVOLT -AMPERE
<br />LIGHTING FIXTURE
<br />INDICATES HOMER
<br />KW
<br />KILOWATT
<br />KWH
<br />KILOWATT HOURS
<br />LTG
<br />LIGHTING
<br />LV
<br />LOW VOLTAGE
<br />MAX
<br />MAXIMUM
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />MIN
<br />MINIMUM
<br />MLO
<br />MAIN LUG ONLY
<br />MTD
<br />MOUNTED
<br />MTG
<br />MOUNTING
<br />N
<br />NEUTRAL
<br />NA
<br />NOT APPLICABLE
<br />NEC
<br />NATIONAL ELECTRICAL CODE
<br />NL
<br />NIGHT LIGHT
<br />NIC
<br />NOT IN CONTRACT
<br />NTS
<br />NOT TO SCALE
<br />OPD
<br />OVER CURRENT PROTECTION DEVICE
<br />P
<br />POLE
<br />PH
<br />PHASE
<br />PVC
<br />POLYVINYL CHLORIDE
<br />PWR
<br />POWER
<br />RGS
<br />RIGID GALVANIZED STEEL
<br />RMS
<br />ROOT MEAN SQUARE VALUE
<br />RPM
<br />REVOLUTIONS PER MINUTE
<br />SWBD
<br />SWITCHBOARD
<br />TTB
<br />TELEPHONE TERMINAL BOARD
<br />TEL
<br />TELEPHONE
<br />TML
<br />TERMINAL
<br />TVSS
<br />TRANSIENT VOLTAGE SURGE
<br />SUPPRESSER
<br />TYP
<br />TYPICAL
<br />UG
<br />UNDERGROUND
<br />UL
<br />UNDERWRITERS LABORATORIES
<br />UPS
<br />UNINTERRUPTIBLE POWER SUPPLY
<br />V
<br />VOLTS
<br />VA
<br />VOLT-AMPERE
<br />VO
<br />TELEPHONE
<br />VFD
<br />VARIABLE FREQUENCY DRIVE
<br />VSD
<br />VARIABLE SPEED DRIVE
<br />W
<br />WATTS
<br />W/
<br />WITH
<br />WP
<br />WEATHERPROOF
<br />XFMR/TTRANSFORMER
<br />CIRCUITING LEGEND
<br />LIGHTING FIXTURE TYPE, REFER
<br />TO LIGHTING FIXTURE SCHEDULE
<br />INDICATES CIRCUIT NUMBER ON
<br />FIXTURES MATCHING ASSOCIATED
<br />3b �_HOMERUN
<br />INDICATES SWITCH CONTROL
<br />LA-3
<br />INDICATES PANEL FROM WHERE
<br />BRANCH CIRCUIT ORIGINATES
<br />CIRCUIT NUMBER
<br />3
<br />ELECTRICAL DEVICE 48"] -MOUNTING HEIGHT A.F.F.
<br />(18" U.O.N.)
<br />*BRANCH CIRCUIT SOURCE PANELBOARD INDICATED IN PARENTHESIS FOR REFERENCE
<br />WHEN HOMERUN IS NOT VISIBLE ON PLAN.
<br />GENERAL NOTES:
<br />1. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL LIGHTING FIXTURES,
<br />RECEPTACLES, OUTLETS, ETC. INDICATED WITH CIRCUIT NUMBERS AND PANEL
<br />DESIGNATIONS. REFER TO SPECIFICATIONS FOR APPLICABLE MEANS AND METHODS.
<br />2. ALTHOUGH ALL BRANCH CIRCUIT WIRE AND CONDUIT IS NOT SHOWN, IT IS THE INTENT
<br />OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM BE
<br />INSTALLED.
<br />3. WIRING SHALL BE 2#12+1#12G IN 3/4"C MINIMUM.
<br />RECEPTACLE BRANCH CIRCUIT WIRING SCHEDULE
<br />CONDUCTOR
<br />MAXIMUM CONDUCTOR LENGTH AT 120V
<br />GROUND
<br />AWG.
<br />AWG.
<br />#12
<br />100'-0"
<br />#12
<br />#10
<br />165'-0"
<br />#10
<br />#8
<br />255'-0"
<br />#10
<br />#6
<br />405'-O"
<br />#10
<br />RECEPTACLE BRANCH CIRCUIT WIRING SCHEDULE NOTES:
<br />1. BASED ON 20A CIRCUIT LOADED TO 9A USING SINGLE PHASE, 2 WIRE
<br />CIRCUITS.
<br />2. THE ABOVE SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED FROM
<br />PANEL TO CENTER OF LEAD TO OVERCOME VOLTAGE DROP.
<br />3. MAKE PROVISIONS FOR JUNCTION BOX ADJACENT TO OUTLET TO TRANSITION TO
<br />#12 WIRE FOR FINAL TERMINATIONS TO DEVICE AS REQUIRED.
<br />LIGHTING BRANCH CIRCUIT WIRING SCHEDULE
<br />CONDUCTOR
<br />MAXIMUM CONDUCTOR
<br />MAXIMUM CONDUCTOR
<br />GROUND
<br />AWG.
<br />LENGTH AT 120V
<br />LENGTH AT 120V
<br />AWG.
<br />#12
<br />75'-0"
<br />175'-0"
<br />#12
<br />#10
<br />120'-0"
<br />285'-0"
<br />#10
<br />#8
<br />190'-0"
<br />445'-O"
<br />#10
<br />#6
<br />300'-0"
<br />-
<br />#10
<br />LUMINAIRE BRANCH CIRCUIT WIRING SCHEDULE NOTES:
<br />1. BASED ON 20A CIRCUIT LOADED TO 12A USING SINGLE PHASE, 2 WIRE CIRCUITS,
<br />2. THE ABOVE SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED FROM
<br />PANEL TO CENTER OF LEAD TO OVERCOME VOLTAGE DROP.
<br />3. MAKE PROVISIONS FOR JUNCTION BOX ADJACENT TO OUTLET TO TRANSITION TO #12
<br />WIRE FOR FINAL TERMINATIONS TO DEVICE AS REQUIRED.
<br />GENERAL NEW WORK NOTES
<br />1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL TRADE DOCUMENTS
<br />PRIOR TO SUBMITTING A BID IN ORDER TO GET A COMPLETE UNDERSTANDING OF
<br />THE ENTIRE SCOPE OF WORK. ALL WORK FOR OTHER TRADES THAT REQUIRE
<br />ELECTRICAL CONNECTIONS, TERMINATIONS, ETC ARE INCLUDED IN THIS SCOPE OF
<br />WORK UNLESS OTHERWISE SPECIFIED.
<br />2. WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED BETWEEN ALL LIGHT
<br />FIXTURES, SWITCHES, SENSORS, POWER PACKS, RELAYS, AND OTHER AUXILIARY
<br />DEVICES.
<br />3. PROVIDE A NYLON PULL CORD IN ALL EMPTY CONDUITS.
<br />4. COORDINATE WITH SECURITY VENDOR PLANS FOR EXACT ELECTRICAL
<br />REQUIREMENTS FOR SECURITY SYSTEM. PROVIDE ALL ASSOCIATED POWER
<br />CONNECTIONS AND EMPTY RACEWAY SYSTEM AND BOXES. PROVIDE PLASTIC END
<br />BUSHINGS AND PULL STRINGS IN ALL CONDUITS.
<br />5. COORDINATE WITH A/V VENDOR PLANS FOR EXACT ELECTRICAL REQUIREMENTS
<br />FOR A/V SYSTEM. PROVIDE ALL ASSOCIATED POWER CONNECTIONS AND EMPTY
<br />RACEWAY SYSTEM AND BOXES. PROVIDE PLASTIC END BUSHINGS AND PULL
<br />STRINGS IN ALL CONDUITS.
<br />6. FURNISH LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE
<br />PROPER AND COMPLETE INSTALLATION OF ALL ELECTRIC WORK SHOWN ON THE
<br />DRAWINGS AND HEREIN SPECIFIED.
<br />7. ALL ITEMS NOT SHOWN ON THE DRAWINGS OR CALLED FOR IN THE
<br />SPECIFICATIONS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE ELECTRICAL
<br />INSTALLATION, SHALL BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT.
<br />8. ALL ELECTRICAL INSTALLATIONS AND GROUNDING SHALL BE IN STRICT
<br />ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE LOCAL, STATE AND
<br />NATIONAL CODES.
<br />9. MATERIALS AND WORKMANSHIP SHALL BE THE BEST OF THEIR RESPECTIVE KIND
<br />AND IN FULL ACCORDANCE WITH THE MOST MODERN ELECTRICAL CONSTRUCTION
<br />STANDARDS. ALL MATERIAL SHALL BE NEW, UNLESS OTHERWISE NOTED AND FREE
<br />OF ANY DEFECTS.
<br />10. ALL WORK SEQUENCES SHALL BE COORDINATED WITH THE OWNER, ARCHITECT
<br />AND OTHER BUILDING TRADES PRIOR TO THE INITIATION OF ANY WORK.
<br />11. ALL BRANCH CIRCUITS RATED AT 120 VOLTS, 20 AMPERES EXCEEDING 75 FEET
<br />SHALL BE MINIMUM #10 AWG.
<br />12. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF
<br />SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH INDIVIDUAL
<br />ELECTRICAL SYSTEM REPRESENTATIVES IN ORDER TO INCLUDE ALL REQUIRED
<br />AUXILIARY EQUIPMENT AND MATERIALS FOR A COMPLETE INSTALLATION.
<br />13. INFORMATION AND COMPONENTS SHOWN ON RISER DIAGRAMS BUT NOT ON
<br />PLANS, AND VICE VERSA, SHALL APPLY OR SHALL BE PROVIDED AS THOUGH
<br />EXPRESSLY REQUIRED ON BOTH. IT IS NOT INTENDED THAT EVERY JUNCTION BOX,
<br />OFFSET, FITTING OR COMPONENT BE SPECIFIED OR SHOWN ON THESE DRAWINGS;
<br />HOWEVER, CONTRACT DOCUMENTS REQUIRE PROVISION OF ALL COMPONENTS
<br />AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL ELECTRICAL
<br />INSTALLATION, WHETHER OR NOT INDICATED OR SPECIFIED.
<br />14. BRANCH CIRCUIT WIRING MAY NOT BE GRAPHICALLY SHOWN ON DRAWINGS AND
<br />MAY BE SHOWN BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND EQUIPMENT.
<br />PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT SHOWN GRAPHICALLY.
<br />WIRING IS SHOWN BY CONDUIT RUNS ON DRAWINGS WHERE SPECIFIC ROUTING IS
<br />REQUIRED OR FOR OTHER SPECIAL REASONS. ONLY ROOMS WITH MULTIPLE
<br />SWITCHING HAVE "SWITCH CONTROL LETTERS" ASSIGNED. ALL WIRING SHALL BE
<br />RUN IN A NEAT AND ORDERLY MANNER.
<br />15. PROVIDE THHN CONDUCTORS IN AREAS WITH HIGH AMBIENT TEMPERATURES
<br />SUCH AS BOILER ROOMS, INCINERATOR ROOMS, MECHANICAL EQUIPMENT
<br />ROOMS ETC., FOR SIZES LARGER THAN NO. 10 AWG.
<br />16. ALL WIRING, BUSSING, WINDINGS, AND ALL OTHER CONDUCTORS ARE BASED ON
<br />THE USE OF COPPER UNLESS OTHERWISE SPECIFIED.
<br />17. ALL WIRING SHALL BE COLOR CODED. WIRING SHALL BE CONCEALED UNLESS
<br />OTHERWISE NOTED.
<br />18. PROVIDE CONDUIT SLEEVES AS REQUIRED. THROUGH FIRE RATED SEPARATIONS,
<br />FIRE SEAL AFTER WIRING IS COMPLETE.
<br />19. WIRING SHALL NOT BE LAID ON, OR ATTACHED TO THE SUSPENDED CEILING OR ITS
<br />SUPPORT WIRES. ALL CABLES SHALL BE RUN PARALLEL OR PERPENDICULAR TO
<br />WALLS. DO NOT RUN CABLES DIAGONALLY THROUGH ANY SPACE.
<br />20. WHERE THE NUMBER OF CURRENT CARRYING CONDUCTORS IN A RACEWAY OR
<br />CABLE EXCEEDS THREE, THE ALLOWABLE AMPACITY SHALL BE REDUCED PER
<br />NATIONAL ELECTRIC CODE TABLE BASED ON NO DIVERSITY. CONSIDER NEUTRALS
<br />TO BE CURRENT CARRYING CONDUCTORS.
<br />21. DO NOT COMBINE CIRCUITS OR USE COMMON NEUTRALS.
<br />22. LABEL ("BROTHER P-TOUCH LABELING SYSTEM" OR APPROVED EQUAL) OR ENGRAVE
<br />EACH RECEPTACLE PLATE WITH PANEL DESIGNATION AND CIRCUIT NUMBER.
<br />23. CONTRACTOR SHALL VISITTHE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING
<br />CONDITIONS. NO CLAIM FOR EXTRA COMPENSATION SHALL BE ENTERTAINED FOR
<br />WORK WHICH A PRELIMINARY EXAMINATION WOULD HAVE REVEALED. THE
<br />SUBMISSION OF A BID WILL BE CONSIDERED AS ACKNOWLEDGMENT ON THE PART
<br />OF THE BIDDER OF HIS VISITATION TO THE SITE.
<br />24. OBTAIN ALL NECESSARY PERMITS AND CERTIFICATES. PRESENT SATISFACTORY
<br />PROOF OF FINAL INSPECTION AND APPROVAL BY AUTHORITIES HAVING
<br />JURISDICTION.
<br />25. MAINTAIN CORRECT PHASE SEQUENCE OF ALL FEEDERS AND CIRCUITS BY
<br />ESTABLISHING PHASE IDENTIFICATION AND MAINTAINING CORRECT RELATIONSHIP
<br />THROUGHOUT THE SYSTEM. PROVIDE LINE BALANCE WITHIN 10% OF NORMAL
<br />LOADS.
<br />26. PROVIDE FLUSH, LOCKING, WEATHERPROOF "WHILE IN USE" TYPE RECEPTACLE
<br />ENCLOSURE; C.W. COLE # TL310-WCS-SH-GFCI-CC (FINISH SELECTED BY THE
<br />ARCHITECT); TYPICAL FOR ALL EXTERIOR RECEPTACLES.
<br />27. PROVIDE TAMPER RESISTANT RECEPTACLES PER NEC ARTICLE 406.12.
<br />FIRE ALARM LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />FIRE ALARM DEVICES:
<br />ALL FIRE ALARM NOTIFICATION DEVICES SHALL BE MOUNTED AT 80" A.F.F.
<br />TO BOTTOM OF STROBE LENS, UNLESS OTHERWISE NOTED. ALL FIRE ALARM
<br />PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO CENTER OF DEVICE.
<br />REMOTE TEST SWITCHES SHALL BE MOUNTED AT 7'-0" A.F.F. IN CORRIDOR
<br />BELOW DUCT SMOKE DETECTOR. THE FOLLOWING DESIGNATIONS SHALL
<br />APPLY TO ALL FIRE ALARM DEVICES; UNLESS OTHERWISE NOTED:
<br />WP = WEATHERPROOF.
<br />CLG = CEILING MOUNTED.
<br />K = KEY OPERATED TEST SWITCH.
<br />WG = WIRE GUARD.
<br />SC = STOPPER COVER.
<br />OAS FIRE ALARM SMOKE DETECTOR.
<br />FIRE ALARM HEAT DETECTOR, COMBINATION RATE -OF -RISE AND ONE
<br />OR/F HUNDRED THIRTY-FIVE DEGREES (135°) F FIXED TEMPERATURE.
<br />FIRE ALARM DUCT MOUNTED SMOKE DETECTOR, INSTALLED BY MECHANICAL
<br />S CONTRACTOR, WIRED AND FURNISHED BY ELECTRICAL CONTRACTOR.
<br />15cd � HORN/STROBE COMBINATION. CANDELA RATING SHALL BE 15, UNLESS
<br />OTHERWISE NOTED.
<br />15cd FIRE ALARM STROBE ONLY. CANDELA RATING SHALL BE 15, UNLESS OTHERWISE
<br />NOTED.
<br />15cd� HORN/STROBE COMBINATION; CEILING MOUNTED. CANDELA RATING SHALL BE
<br />15, UNLESS OTHERWISE NOTED.
<br />15cd FIRE ALARM STROBE ONLY; CEILING MOUNTED. CANDELA RATING SHALL BE 15,
<br />C UNLESS OTHERWISE NOTED.
<br />SELF CONTAINED CARBON MONOXIDE DETECTOR, 120 VOLT WITH BATTERY
<br />OCO BACKUP. INTERCONNECTABLE.
<br />SELF CONTAINED SMOKE DETECTOR, 120 VOLT, PHOTOELECTRIC TYPE, WITH
<br />OP BATTERY BACKUP. INTERCONNECTABLE.
<br />0AS
<br />SELF CONTAINED COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR,
<br />CO 120 VOLT, WITH BATTERY BACKUP, INTERCONNECTABLE.
<br />FRCP I FIRE ALARM CONTROL PANEL.
<br />FF-A-R-Al FIRE ALARM REMOTE ANNUNCIATOR.
<br />FAGM FIRE ALARM GRAPHIC MAP.
<br />FAWC FIRE ALARM WIRELESS COMMUNICATOR.
<br />FAAC FIRE ALARM AS -BUILT CABINET.
<br />FA-7 FIRE ALARM TERMINAL CABINET.
<br />F-RT-51 FIRE ALARM KEYED DUCT SMOKE REMOTE TEST STATION.
<br />�F FIRE ALARM PULL STATION.
<br />IM FIRE ALARM ISOLATION MODULE.
<br />AIM FIRE ALARM MONITOR MODULE.
<br />oM FIRE ALARM CONTROL MODULE. PROVIDE AN INTERMEDIATE RELAY TO SUIT
<br />LOAD.
<br />INTERMEDIATE RELAY, PROVIDE AS NEEDED.
<br />�K KEY ACCESS BOX.
<br />® FIRE ALARM RADIO MASTER BOX ANTENNA, MOUNT AT HIGHEST POINT ON
<br />BUILDING EXTERIOR,
<br />FIRE ALARM SPRINKLER FLOW SWITCH, BY OTHERS. FURNISHED AND
<br />WF INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND WIRED BY THE
<br />ELECTRICAL CONTRACTOR.
<br />FIRE ALARM SPRINKLER PRESSURE SWITCH, BY OTHERS. FURNISHED AND
<br />PS INSTALLED BYTHE FIRE PROTECTION CONTRACTOR AND WIRED BY THE
<br />ELECTRICAL CONTRACTOR.
<br />FIRE ALARM SPRINKLER TAMPER SWITCH, BY OTHERS. FURNISHED AND
<br />TS INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND WIRED BY THE
<br />ELECTRICAL CONTRACTOR.
<br />i FIRE ALARM SYSTEM MASTERBOX.
<br />FIRE BELL, FURNISHED BY FIRE PROTECTION CONTRACTOR, WIRED AND
<br />FB INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE WIRING PER THE
<br />MANUFACTURER'S RECOMMENDATIONS (120V OR 24V).
<br />FIRE ALARM BEACON.
<br />DK FIRE ALARM DRILL KEY.
<br />POWER OUTLETS & DEVICES LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />POWER RECEPTACLES:
<br />ALL RECEPTACLES SHALL BE MOUNTED AT 18" A.F.F. TO CENTER, UNLESS
<br />OTHERWISE NOTED. THE FOLLOWING DESIGNATIONS SHALL APPLY TO ALL
<br />RECEPTACLES TYPES:
<br />C = MOUNTED AT 6" ABOVE BACK SPLASH TO BOTTOM, REFER TO
<br />ARCHITECTURAL ELEVATIONS FOR COORDINATION.
<br />CLG = CEILING MOUNTED.
<br />DW = DISHWASHER.
<br />EWC = ELECTRIC WATER COOLER.
<br />GD = GARBAGE DISPOSAL.
<br />HD = HAND DRYER.
<br />IG - ISOLATED GROUND.
<br />M = MICROWAVE.
<br />T = TAMPER RESISTANT.
<br />TL = TWIST LOCK.
<br />WP = WEATHERPROOF.
<br />Cp SINGLE RECEPTACLE ON NORMAL CIRCUIT.
<br />DUPLEX RECEPTACLE ON NORMAL CIRCUIT.
<br />CEILING MOUNTED DUPLEX RECEPTACLE ON NORMAL CIRCUIT.
<br />DOUBLE DUPLEX RECEPTACLE ON NORMAL CIRCUIT.
<br />`It' DUPLEX GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE ON NORMAL
<br />CIRCUIT.
<br />fXX-XXR SPECIAL PURPOSE RECEPTACLE WITH NEMA CONFIGURATION TO MATCH
<br />EQUIPMENT.
<br />JOY JUNCTION BOX.
<br />U2 DUPLEX RECEPTACLE (TAMPER RESISTANT) W/ (1) USB TYPE A PORT AND (1)
<br />USB TYPE C PORT.
<br />U4 DUPLEX RECEPTACLE (TAMPER RESISTANT) W/ (2) USB TYPE A PORTS AND (2)
<br />USB TYPE C PORTS.
<br />F-B1 # FLOOR BOX; REFER TO FLOOR BOX DEVICE SCHEDULE FOR ADDITIONAL
<br />INFORMATION.
<br />FF # FURNITURE FEED DEVICE; REFER TO FURNITURE FEED DEVICE SCHEDULE FOR
<br />ADDITIONAL INFORMATION.
<br />SURFACE METAL RACEWAY, EQUAL TO WIREMOLD SERIES 3000. PROVIDE
<br />WITH RECEPTACLES AS INDICATED ON PLANS WITH ACCESSORIES (ELBOWS,
<br />COVERS, COUPLINGS, ETC.) FOR A CONTINUOUS, COMPLETE INSTALLATION.
<br />COLOR BY ARCHITECT, IVORY OR GRAY.
<br />SURFACE METAL RACEWAY, EQUALTO WIREMOLD SERIES 4000. PROVIDE
<br />WITH RECEPTACLES AND TECHNOLOGY OUTLETS AS INDICATED ON PLANS
<br />WITH ACCESSORIES (ELBOWS, COVERS, COUPLINGS, DIVIDERS, ETC.) FOR A
<br />CONTINUOUS, COMPLETE INSTALLATION. COLOR BY ARCHITECT, IVORY OR
<br />GRAY.
<br />PLUGMOLD.
<br />El ❑P -I POWER FURNITURE FEED.
<br />EMGB ELECTRICAL MAIN GROUNDING BUSBAR.
<br />SPD SURGE PROTECTIVE DEVICE.
<br />LIGHTING FIXTURE LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />A LIGHT FIXTURE (LUMINAIRE) ON NORMAL CIRCUIT. LETTER INDICATES TYPE.
<br />®a SUBSCRIPT INDICATES CONTROL AND CIRCUIT NUMBER.
<br />AE LIGHT FIXTURE (LUMINAIRE) TO BE PROVIDED WITH INTEGRAL BATTERY
<br />®a BACKUP. LETTER INDICATES TYPE. SUBSCRIPT INDICATES CONTROL AND CIRCUIT
<br />NUMBER.
<br />o-p SITE LIGHT FIXTURE (LUMINAIRE). REFER TO POLE BASE DETAIL.
<br />®� EXIT SIGN, ONE OR TWO FACED. ARROWS DENOTE DIRECTION. SHADING
<br />DENOTES NUMBER AND ORIENTATION OF SIGN FACE(S).
<br />EXIT SIGN WITH EMERGENCY LIGHTS. ARROWS DENOTE DIRECTION. SHADING
<br />DENOTES NUMBER AND ORIENTATION OF SIGN FACE(S).
<br />EMERGENCY LIGHTING BATTERY UNIT WITH EMERGENCY LIGHTS
<br />EMERGENCY LIGHTING BATTERY UNIT WITH EMERGENCY LIGHTS AND REMOTE
<br />CAPACITY
<br />Ak REMOTE EMERGENCY HEAD
<br />_INV_j INVERTER.
<br />POWER DISTRIBUTION LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />® 480Y/277 VOLT PANELBOARD, SURFACE MOUNTED, REFER TO SCHEDULE OF
<br />PANELBOARDS.
<br />480Y/277 VOLT PANELBOARD, FLUSH MOUNTED, REFER TO SCHEDULE OF
<br />PANELBOARDS.
<br />208Y/120 VOLT PANELBOARD, SURFACE MOUNTED, REFER TO SCHEDULE OF
<br />PANELBOARDS.
<br />= 208Y/120 VOLT PANELBOARD, FLUSH MOUNTED, REFER TO SCHEDULE OF
<br />PANELBOARDS,
<br />METER SOCKET AND UTILITY COMPANY ELECTRIC METER, OR AS NOTED.
<br />0 ENCLOSED CIRCUIT BREAKER.
<br />LIGHTING CONTROL LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />Sa SINGLE POLE SWITCH. SUBSCRIPT INDICATES LIGHT FIXTURE CONTROL.
<br />120V ASTRONOMICAL TIME SWITCH WITH OILED DISPLAY, EQUALTO
<br />STCa WATTSTOPPER #RT-200,MOUNTED AT 48" A.F.F TO CENTER. SUBSCRIPT
<br />INDICATES LIGHT FIXTURE CONTROL.
<br />SWSa WATTSTOPPER #DSW-301 OCCUPANCY SENSOR, WALL MOUNTED AT 48" A.F.F.
<br />CEILING MOUNTED PHOTOSENSOR FOR DAY LIGHT HARVESTING. EQUAL TO
<br />WATTSTOPPER #LMLS-500. PHOTOSENSOR PLACEMENT PER MANUFACTURER'S
<br />RECOMMENDED LOCATIONS. PLACEMENT ON FLOOR PLANS IS
<br />DIAGRAMMATICAL.
<br />CEILING MOUNTED DIGITAL DUALTECHNOLOGY OCCUPANCY SENSOR, PASSIVE
<br />INFRARED AND ULTRASONIC TECHNOLOGY, EQUAL TO WATTSTOPPER
<br />#LMDC-100, PROVIDE WITH POWER PACK. MOUNT AT LEAST 6-0" FROM A
<br />SUPPLY REGISTER. LOWER CASE LETTER INDICATES SWITCH CONTROL. TIME
<br />OS a DELAY SHALL BE 15 MINUTES. POWER PACK SHALL BE LOCATED ABOVE
<br />CEILING, ABOVE SENSOR. MOUNT OCCUPANCY SENSOR AT SAME HEIGHT OR
<br />BELOW ANY PENDANT MOUNTED LIGHTING FIXTURES SO AS TO NOT
<br />OBSTRUCT OCCUPANCY SENSOR.
<br />WALL/CORNER MOUNTED DIGITAL DUAL TECHNOLOGY OCCUPANCY SENSOR,
<br />PASSIVE INFRARED AND ULTRASONIC TECHNOLOGY, EQUAL TO WATTSTOPPER
<br />#LMDX-100, PROVIDE WITH POWER PACK. MOUNT AT LEAST 6'-0" FROM A
<br />SUPPLY REGISTER. LOWER CASE LETTER INDICATES SWITCH CONTROL. TIME
<br />Ha DELAY SHALL BE 15 MINUTES. POWER PACK SHALL BE LOCATED ABOVE
<br />CEILING, ABOVE SENSOR. MOUNT OCCUPANCY SENSOR AT SAME HEIGHT OR
<br />BELOW ANY PENDANT MOUNTED LIGHTING FIXTURES SO AS TO NOT
<br />OBSTRUCT OCCUPANCY SENSOR.
<br />TC TIMECLOCK
<br />TELECOMMUNICATION LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />TELECOMMUNICATION OUTLETS:
<br />COORDINATE ALL LOCATIONS AND MOUNTING HEIGHTS WITH OWNERS AND
<br />TELECOMMUNICATIONS VENDOR PRIOR TO ROUGH -IN; MOUNT VERTICAL
<br />OUTLETS AT 18"A.F.F. TO CENTER UNLESS OTHERWISE DIRECTED. THE
<br />DESIGNATIONS SHALL APPLY TO ALL OUTLET TYPES:
<br />C = INDICATES MOUNTED AT 6" ABOVE BACK SPLASH TO BOTTOM,
<br />REFER TO ARCHITECTURAL ELEVATIONS.
<br />F = INDICATES FLOOR MOUNTED.
<br />P = INDICATES MOUNTED AT 47" A.F.F.
<br />W = INDICATES MOUNTED AT 54" A.F.F.
<br />H - INDICATES MOUNTED AT 82" A.F.F.
<br />TELECOMMUNICATIONS OUTLET, REFER TO TELECOMMUNICATIONS
<br />FACEPLATE DETAIL FOR ADDITIONAL INFORMATION.
<br />WIRELESS ACCESS POINT. CEILING OR WALL MOUNTED. REFER TO
<br />TELECOMMUNICATIONS FACEPLATE DETAIL FOR ADDITIONAL INFORMATION.
<br />❑D ❑D -I TELECOMMUNICATIONS FURNITURE FEED.
<br />MGB MAIN TELECOMMUNICATIONS GROUND BAR,
<br />TGB TELECOMMUNICATIONS GROUND BAR.
<br />TELECOMMUNICATION TERMINAL BOARD, PROVIDE GRADE "A", 3/4"
<br />PLYWOOD COMPLETELY PAINTED WITH FIREPROOF PAINT AS REQUIRED PER
<br />CODE.
<br />BUILDING GROUNDING GRID LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />GROUND ROD.
<br />a
<br />G BUILDING GROUND CABLE.
<br />EXOTHERMIC BONDING CONNECTION.
<br />f� BOLTED BONDING CONNECTION.
<br />MOTOR AND CONTROLS LEGEND
<br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT
<br />SEM BOILER EMERGENCY SWITCH. AROW-HART#CS120 WITH MULLBERRY#41020
<br />PLATE.
<br />SINGLE POLE MOTOR RATED SWITCH WITH OVERLOAD HEATER (MANUAL
<br />ST MOTOR STARTER).
<br />EIJ UN -FUSED DISCONNECT SWITCH WITH RATINGS.
<br />30/3/1
<br />�NEMA RATING. "WP" INDICATES RAINTIGHT
<br />NUMBER OF POLES
<br />SWITCH SIZE
<br />01 FUSED DISCONNECT SWITCH WITH RATINGS.
<br />30/20/3/DE/1
<br />LNEMA RATING. "WP" INDICATES RAINTIGHT
<br />INDICATES DUAL ELEMENT FUSES
<br />NUMBER OF POLES
<br />FUSE SIZE. %F" INDICATES NON FUSED
<br />SWITCH SIZE
<br />MOTOR; "3" INDICATES HORSEPOWER RATING.
<br />XXX EQUIPMENT TAG, REFER TO MECHANICAL EQUIPMENT SCHEDULE FOR MORE
<br />XX INFORMATION.
<br />PROJECT:
<br />PINCHASERS EAST PASCO
<br />ANTHONY PERRONE
<br />6816 GALL BOULEVARD
<br />ZEPHYRHILLS, FL 33542
<br />PROJECT NUMBER: 21 161
<br />m
<br />MO
<br />o
<br />C",U
<br />oU
<br />L1J Q
<br />�uj
<br />U�u
<br />Ov
<br />�o
<br />W°�
<br />O�
<br />10
<br />�
<br />o
<br />C`7 `0
<br />ov
<br />� N �
<br />w Lri
<br />Ln
<br />v J = V)00
<br />0
<br />Lo
<br />W LL
<br />z w.
<br />�
<br />N
<br />Q cV
<br />z J
<br />ce
<br />W Z N
<br />w
<br />U CO
<br />Q o
<br />N �
<br />O � �
<br />`p cct
<br />0 0 r,_ 00
<br />M M
<br />M
<br />♦� O a-,
<br />M M
<br />Z 0 qO
<br />O O
<br />U 0 ooc
<br />O
<br />�Z
<br />a
<br />M
<br />00
<br />STAMP:
<br />}�Rfiilfll9wAAlf0f'f �f
<br />s
<br />FLCR' `
<br />• �Y
<br />_1
<br />"'+.��sr+�+•��
<br />ISSUE:
<br />DATE:
<br />ISSUED FOR PERMIT
<br />Ol /25/2023
<br />DRAWING SCALE: NOTED
<br />DRAWN BY: SB
<br />CHECKED BY: MD
<br />DRAWING TITLE:
<br />ELECTRICAL - LEGENDS & SYMBOLS
<br />DRAWING NUMBER:
<br />0,0