ABBREVIATIONS <br />ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />A/AMP AMPERE <br />AC ALTERNATING CURRENT <br />ADA AMERICAN WITH DISABILITIES ACT <br />AF AMPERE FRAME <br />AFF ABOVE FINISHED FLOOR <br />AHJ AUTHORITY HAVING JURISDICTION <br />AIC AMPERE INTERRUPTING CAPACITY <br />AL ALUMINUM <br />AT AMPERE TRIP <br />ATS AUTOMATIC TRANSFER SWITCH <br />AWG AMERICAN WIRE GAUGE <br />AV AUDIO VISUAL <br />BFG BELOW FINISHED GRADE <br />BOF BOTTOM OF FIXTURE <br />C CONDUIT <br />CA CABLE <br />CAT CATALOG <br />CATV CABLE TELEVISION <br />CB CIRCUIT BREAKER <br />CBA COLOR BY ARCHITECT <br />CD CANDELA <br />CKT CIRCUITS <br />CU COPPER <br />dB DECIBEL <br />DC DIRECT CURRENT <br />DN DOWN <br />DWG DRAWING <br />EC ELECTRICAL CONTRACTOR <br />ETR EXISTING TO REMAIN <br />F FAHRENHEIT <br />FA FIRE ALARM <br />FACP FIRE ALARM CONTROL PANEL <br />FBA FINISH BY ARCHITECT <br />FLA FULL LOAD AMPERES <br />G GROUND <br />GEC GROUNDING ELECTRODE CONDUCTOR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GND GROUND <br />HP HORSEPOWER <br />HVAC HEATING, VENTILATION, AND AIR <br />CONDITIONING <br />IG ISOLATED GROUND <br />KVA KILOVOLT -AMPERE <br />LIGHTING FIXTURE <br />INDICATES HOMER <br />KW <br />KILOWATT <br />KWH <br />KILOWATT HOURS <br />LTG <br />LIGHTING <br />LV <br />LOW VOLTAGE <br />MAX <br />MAXIMUM <br />MCB <br />MAIN CIRCUIT BREAKER <br />MIN <br />MINIMUM <br />MLO <br />MAIN LUG ONLY <br />MTD <br />MOUNTED <br />MTG <br />MOUNTING <br />N <br />NEUTRAL <br />NA <br />NOT APPLICABLE <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NL <br />NIGHT LIGHT <br />NIC <br />NOT IN CONTRACT <br />NTS <br />NOT TO SCALE <br />OPD <br />OVER CURRENT PROTECTION DEVICE <br />P <br />POLE <br />PH <br />PHASE <br />PVC <br />POLYVINYL CHLORIDE <br />PWR <br />POWER <br />RGS <br />RIGID GALVANIZED STEEL <br />RMS <br />ROOT MEAN SQUARE VALUE <br />RPM <br />REVOLUTIONS PER MINUTE <br />SWBD <br />SWITCHBOARD <br />TTB <br />TELEPHONE TERMINAL BOARD <br />TEL <br />TELEPHONE <br />TML <br />TERMINAL <br />TVSS <br />TRANSIENT VOLTAGE SURGE <br />SUPPRESSER <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UL <br />UNDERWRITERS LABORATORIES <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />V <br />VOLTS <br />VA <br />VOLT-AMPERE <br />VO <br />TELEPHONE <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />VSD <br />VARIABLE SPEED DRIVE <br />W <br />WATTS <br />W/ <br />WITH <br />WP <br />WEATHERPROOF <br />XFMR/TTRANSFORMER <br />CIRCUITING LEGEND <br />LIGHTING FIXTURE TYPE, REFER <br />TO LIGHTING FIXTURE SCHEDULE <br />INDICATES CIRCUIT NUMBER ON <br />FIXTURES MATCHING ASSOCIATED <br />3b �_HOMERUN <br />INDICATES SWITCH CONTROL <br />LA-3 <br />INDICATES PANEL FROM WHERE <br />BRANCH CIRCUIT ORIGINATES <br />CIRCUIT NUMBER <br />3 <br />ELECTRICAL DEVICE 48"] -MOUNTING HEIGHT A.F.F. <br />(18" U.O.N.) <br />*BRANCH CIRCUIT SOURCE PANELBOARD INDICATED IN PARENTHESIS FOR REFERENCE <br />WHEN HOMERUN IS NOT VISIBLE ON PLAN. <br />GENERAL NOTES: <br />1. WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL LIGHTING FIXTURES, <br />RECEPTACLES, OUTLETS, ETC. INDICATED WITH CIRCUIT NUMBERS AND PANEL <br />DESIGNATIONS. REFER TO SPECIFICATIONS FOR APPLICABLE MEANS AND METHODS. <br />2. ALTHOUGH ALL BRANCH CIRCUIT WIRE AND CONDUIT IS NOT SHOWN, IT IS THE INTENT <br />OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM BE <br />INSTALLED. <br />3. WIRING SHALL BE 2#12+1#12G IN 3/4"C MINIMUM. <br />RECEPTACLE BRANCH CIRCUIT WIRING SCHEDULE <br />CONDUCTOR <br />MAXIMUM CONDUCTOR LENGTH AT 120V <br />GROUND <br />AWG. <br />AWG. <br />#12 <br />100'-0" <br />#12 <br />#10 <br />165'-0" <br />#10 <br />#8 <br />255'-0" <br />#10 <br />#6 <br />405'-O" <br />#10 <br />RECEPTACLE BRANCH CIRCUIT WIRING SCHEDULE NOTES: <br />1. BASED ON 20A CIRCUIT LOADED TO 9A USING SINGLE PHASE, 2 WIRE <br />CIRCUITS. <br />2. THE ABOVE SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED FROM <br />PANEL TO CENTER OF LEAD TO OVERCOME VOLTAGE DROP. <br />3. MAKE PROVISIONS FOR JUNCTION BOX ADJACENT TO OUTLET TO TRANSITION TO <br />#12 WIRE FOR FINAL TERMINATIONS TO DEVICE AS REQUIRED. <br />LIGHTING BRANCH CIRCUIT WIRING SCHEDULE <br />CONDUCTOR <br />MAXIMUM CONDUCTOR <br />MAXIMUM CONDUCTOR <br />GROUND <br />AWG. <br />LENGTH AT 120V <br />LENGTH AT 120V <br />AWG. <br />#12 <br />75'-0" <br />175'-0" <br />#12 <br />#10 <br />120'-0" <br />285'-0" <br />#10 <br />#8 <br />190'-0" <br />445'-O" <br />#10 <br />#6 <br />300'-0" <br />- <br />#10 <br />LUMINAIRE BRANCH CIRCUIT WIRING SCHEDULE NOTES: <br />1. BASED ON 20A CIRCUIT LOADED TO 12A USING SINGLE PHASE, 2 WIRE CIRCUITS, <br />2. THE ABOVE SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED FROM <br />PANEL TO CENTER OF LEAD TO OVERCOME VOLTAGE DROP. <br />3. MAKE PROVISIONS FOR JUNCTION BOX ADJACENT TO OUTLET TO TRANSITION TO #12 <br />WIRE FOR FINAL TERMINATIONS TO DEVICE AS REQUIRED. <br />GENERAL NEW WORK NOTES <br />1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL TRADE DOCUMENTS <br />PRIOR TO SUBMITTING A BID IN ORDER TO GET A COMPLETE UNDERSTANDING OF <br />THE ENTIRE SCOPE OF WORK. ALL WORK FOR OTHER TRADES THAT REQUIRE <br />ELECTRICAL CONNECTIONS, TERMINATIONS, ETC ARE INCLUDED IN THIS SCOPE OF <br />WORK UNLESS OTHERWISE SPECIFIED. <br />2. WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED BETWEEN ALL LIGHT <br />FIXTURES, SWITCHES, SENSORS, POWER PACKS, RELAYS, AND OTHER AUXILIARY <br />DEVICES. <br />3. PROVIDE A NYLON PULL CORD IN ALL EMPTY CONDUITS. <br />4. COORDINATE WITH SECURITY VENDOR PLANS FOR EXACT ELECTRICAL <br />REQUIREMENTS FOR SECURITY SYSTEM. PROVIDE ALL ASSOCIATED POWER <br />CONNECTIONS AND EMPTY RACEWAY SYSTEM AND BOXES. PROVIDE PLASTIC END <br />BUSHINGS AND PULL STRINGS IN ALL CONDUITS. <br />5. COORDINATE WITH A/V VENDOR PLANS FOR EXACT ELECTRICAL REQUIREMENTS <br />FOR A/V SYSTEM. PROVIDE ALL ASSOCIATED POWER CONNECTIONS AND EMPTY <br />RACEWAY SYSTEM AND BOXES. PROVIDE PLASTIC END BUSHINGS AND PULL <br />STRINGS IN ALL CONDUITS. <br />6. FURNISH LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE <br />PROPER AND COMPLETE INSTALLATION OF ALL ELECTRIC WORK SHOWN ON THE <br />DRAWINGS AND HEREIN SPECIFIED. <br />7. ALL ITEMS NOT SHOWN ON THE DRAWINGS OR CALLED FOR IN THE <br />SPECIFICATIONS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE ELECTRICAL <br />INSTALLATION, SHALL BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. <br />8. ALL ELECTRICAL INSTALLATIONS AND GROUNDING SHALL BE IN STRICT <br />ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE LOCAL, STATE AND <br />NATIONAL CODES. <br />9. MATERIALS AND WORKMANSHIP SHALL BE THE BEST OF THEIR RESPECTIVE KIND <br />AND IN FULL ACCORDANCE WITH THE MOST MODERN ELECTRICAL CONSTRUCTION <br />STANDARDS. ALL MATERIAL SHALL BE NEW, UNLESS OTHERWISE NOTED AND FREE <br />OF ANY DEFECTS. <br />10. ALL WORK SEQUENCES SHALL BE COORDINATED WITH THE OWNER, ARCHITECT <br />AND OTHER BUILDING TRADES PRIOR TO THE INITIATION OF ANY WORK. <br />11. ALL BRANCH CIRCUITS RATED AT 120 VOLTS, 20 AMPERES EXCEEDING 75 FEET <br />SHALL BE MINIMUM #10 AWG. <br />12. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF <br />SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH INDIVIDUAL <br />ELECTRICAL SYSTEM REPRESENTATIVES IN ORDER TO INCLUDE ALL REQUIRED <br />AUXILIARY EQUIPMENT AND MATERIALS FOR A COMPLETE INSTALLATION. <br />13. INFORMATION AND COMPONENTS SHOWN ON RISER DIAGRAMS BUT NOT ON <br />PLANS, AND VICE VERSA, SHALL APPLY OR SHALL BE PROVIDED AS THOUGH <br />EXPRESSLY REQUIRED ON BOTH. IT IS NOT INTENDED THAT EVERY JUNCTION BOX, <br />OFFSET, FITTING OR COMPONENT BE SPECIFIED OR SHOWN ON THESE DRAWINGS; <br />HOWEVER, CONTRACT DOCUMENTS REQUIRE PROVISION OF ALL COMPONENTS <br />AND MATERIALS NECESSARY FOR COMPLETE AND OPERATIONAL ELECTRICAL <br />INSTALLATION, WHETHER OR NOT INDICATED OR SPECIFIED. <br />14. BRANCH CIRCUIT WIRING MAY NOT BE GRAPHICALLY SHOWN ON DRAWINGS AND <br />MAY BE SHOWN BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND EQUIPMENT. <br />PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT SHOWN GRAPHICALLY. <br />WIRING IS SHOWN BY CONDUIT RUNS ON DRAWINGS WHERE SPECIFIC ROUTING IS <br />REQUIRED OR FOR OTHER SPECIAL REASONS. ONLY ROOMS WITH MULTIPLE <br />SWITCHING HAVE "SWITCH CONTROL LETTERS" ASSIGNED. ALL WIRING SHALL BE <br />RUN IN A NEAT AND ORDERLY MANNER. <br />15. PROVIDE THHN CONDUCTORS IN AREAS WITH HIGH AMBIENT TEMPERATURES <br />SUCH AS BOILER ROOMS, INCINERATOR ROOMS, MECHANICAL EQUIPMENT <br />ROOMS ETC., FOR SIZES LARGER THAN NO. 10 AWG. <br />16. ALL WIRING, BUSSING, WINDINGS, AND ALL OTHER CONDUCTORS ARE BASED ON <br />THE USE OF COPPER UNLESS OTHERWISE SPECIFIED. <br />17. ALL WIRING SHALL BE COLOR CODED. WIRING SHALL BE CONCEALED UNLESS <br />OTHERWISE NOTED. <br />18. PROVIDE CONDUIT SLEEVES AS REQUIRED. THROUGH FIRE RATED SEPARATIONS, <br />FIRE SEAL AFTER WIRING IS COMPLETE. <br />19. WIRING SHALL NOT BE LAID ON, OR ATTACHED TO THE SUSPENDED CEILING OR ITS <br />SUPPORT WIRES. ALL CABLES SHALL BE RUN PARALLEL OR PERPENDICULAR TO <br />WALLS. DO NOT RUN CABLES DIAGONALLY THROUGH ANY SPACE. <br />20. WHERE THE NUMBER OF CURRENT CARRYING CONDUCTORS IN A RACEWAY OR <br />CABLE EXCEEDS THREE, THE ALLOWABLE AMPACITY SHALL BE REDUCED PER <br />NATIONAL ELECTRIC CODE TABLE BASED ON NO DIVERSITY. CONSIDER NEUTRALS <br />TO BE CURRENT CARRYING CONDUCTORS. <br />21. DO NOT COMBINE CIRCUITS OR USE COMMON NEUTRALS. <br />22. LABEL ("BROTHER P-TOUCH LABELING SYSTEM" OR APPROVED EQUAL) OR ENGRAVE <br />EACH RECEPTACLE PLATE WITH PANEL DESIGNATION AND CIRCUIT NUMBER. <br />23. CONTRACTOR SHALL VISITTHE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING <br />CONDITIONS. NO CLAIM FOR EXTRA COMPENSATION SHALL BE ENTERTAINED FOR <br />WORK WHICH A PRELIMINARY EXAMINATION WOULD HAVE REVEALED. THE <br />SUBMISSION OF A BID WILL BE CONSIDERED AS ACKNOWLEDGMENT ON THE PART <br />OF THE BIDDER OF HIS VISITATION TO THE SITE. <br />24. OBTAIN ALL NECESSARY PERMITS AND CERTIFICATES. PRESENT SATISFACTORY <br />PROOF OF FINAL INSPECTION AND APPROVAL BY AUTHORITIES HAVING <br />JURISDICTION. <br />25. MAINTAIN CORRECT PHASE SEQUENCE OF ALL FEEDERS AND CIRCUITS BY <br />ESTABLISHING PHASE IDENTIFICATION AND MAINTAINING CORRECT RELATIONSHIP <br />THROUGHOUT THE SYSTEM. PROVIDE LINE BALANCE WITHIN 10% OF NORMAL <br />LOADS. <br />26. PROVIDE FLUSH, LOCKING, WEATHERPROOF "WHILE IN USE" TYPE RECEPTACLE <br />ENCLOSURE; C.W. COLE # TL310-WCS-SH-GFCI-CC (FINISH SELECTED BY THE <br />ARCHITECT); TYPICAL FOR ALL EXTERIOR RECEPTACLES. <br />27. PROVIDE TAMPER RESISTANT RECEPTACLES PER NEC ARTICLE 406.12. <br />FIRE ALARM LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />FIRE ALARM DEVICES: <br />ALL FIRE ALARM NOTIFICATION DEVICES SHALL BE MOUNTED AT 80" A.F.F. <br />TO BOTTOM OF STROBE LENS, UNLESS OTHERWISE NOTED. ALL FIRE ALARM <br />PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO CENTER OF DEVICE. <br />REMOTE TEST SWITCHES SHALL BE MOUNTED AT 7'-0" A.F.F. IN CORRIDOR <br />BELOW DUCT SMOKE DETECTOR. THE FOLLOWING DESIGNATIONS SHALL <br />APPLY TO ALL FIRE ALARM DEVICES; UNLESS OTHERWISE NOTED: <br />WP = WEATHERPROOF. <br />CLG = CEILING MOUNTED. <br />K = KEY OPERATED TEST SWITCH. <br />WG = WIRE GUARD. <br />SC = STOPPER COVER. <br />OAS FIRE ALARM SMOKE DETECTOR. <br />FIRE ALARM HEAT DETECTOR, COMBINATION RATE -OF -RISE AND ONE <br />OR/F HUNDRED THIRTY-FIVE DEGREES (135°) F FIXED TEMPERATURE. <br />FIRE ALARM DUCT MOUNTED SMOKE DETECTOR, INSTALLED BY MECHANICAL <br />S CONTRACTOR, WIRED AND FURNISHED BY ELECTRICAL CONTRACTOR. <br />15cd � HORN/STROBE COMBINATION. CANDELA RATING SHALL BE 15, UNLESS <br />OTHERWISE NOTED. <br />15cd FIRE ALARM STROBE ONLY. CANDELA RATING SHALL BE 15, UNLESS OTHERWISE <br />NOTED. <br />15cd� HORN/STROBE COMBINATION; CEILING MOUNTED. CANDELA RATING SHALL BE <br />15, UNLESS OTHERWISE NOTED. <br />15cd FIRE ALARM STROBE ONLY; CEILING MOUNTED. CANDELA RATING SHALL BE 15, <br />C UNLESS OTHERWISE NOTED. <br />SELF CONTAINED CARBON MONOXIDE DETECTOR, 120 VOLT WITH BATTERY <br />OCO BACKUP. INTERCONNECTABLE. <br />SELF CONTAINED SMOKE DETECTOR, 120 VOLT, PHOTOELECTRIC TYPE, WITH <br />OP BATTERY BACKUP. INTERCONNECTABLE. <br />0AS <br />SELF CONTAINED COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR, <br />CO 120 VOLT, WITH BATTERY BACKUP, INTERCONNECTABLE. <br />FRCP I FIRE ALARM CONTROL PANEL. <br />FF-A-R-Al FIRE ALARM REMOTE ANNUNCIATOR. <br />FAGM FIRE ALARM GRAPHIC MAP. <br />FAWC FIRE ALARM WIRELESS COMMUNICATOR. <br />FAAC FIRE ALARM AS -BUILT CABINET. <br />FA-7 FIRE ALARM TERMINAL CABINET. <br />F-RT-51 FIRE ALARM KEYED DUCT SMOKE REMOTE TEST STATION. <br />�F FIRE ALARM PULL STATION. <br />IM FIRE ALARM ISOLATION MODULE. <br />AIM FIRE ALARM MONITOR MODULE. <br />oM FIRE ALARM CONTROL MODULE. PROVIDE AN INTERMEDIATE RELAY TO SUIT <br />LOAD. <br />INTERMEDIATE RELAY, PROVIDE AS NEEDED. <br />�K KEY ACCESS BOX. <br />® FIRE ALARM RADIO MASTER BOX ANTENNA, MOUNT AT HIGHEST POINT ON <br />BUILDING EXTERIOR, <br />FIRE ALARM SPRINKLER FLOW SWITCH, BY OTHERS. FURNISHED AND <br />WF INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND WIRED BY THE <br />ELECTRICAL CONTRACTOR. <br />FIRE ALARM SPRINKLER PRESSURE SWITCH, BY OTHERS. FURNISHED AND <br />PS INSTALLED BYTHE FIRE PROTECTION CONTRACTOR AND WIRED BY THE <br />ELECTRICAL CONTRACTOR. <br />FIRE ALARM SPRINKLER TAMPER SWITCH, BY OTHERS. FURNISHED AND <br />TS INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND WIRED BY THE <br />ELECTRICAL CONTRACTOR. <br />i FIRE ALARM SYSTEM MASTERBOX. <br />FIRE BELL, FURNISHED BY FIRE PROTECTION CONTRACTOR, WIRED AND <br />FB INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE WIRING PER THE <br />MANUFACTURER'S RECOMMENDATIONS (120V OR 24V). <br />FIRE ALARM BEACON. <br />DK FIRE ALARM DRILL KEY. <br />POWER OUTLETS & DEVICES LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />POWER RECEPTACLES: <br />ALL RECEPTACLES SHALL BE MOUNTED AT 18" A.F.F. TO CENTER, UNLESS <br />OTHERWISE NOTED. THE FOLLOWING DESIGNATIONS SHALL APPLY TO ALL <br />RECEPTACLES TYPES: <br />C = MOUNTED AT 6" ABOVE BACK SPLASH TO BOTTOM, REFER TO <br />ARCHITECTURAL ELEVATIONS FOR COORDINATION. <br />CLG = CEILING MOUNTED. <br />DW = DISHWASHER. <br />EWC = ELECTRIC WATER COOLER. <br />GD = GARBAGE DISPOSAL. <br />HD = HAND DRYER. <br />IG - ISOLATED GROUND. <br />M = MICROWAVE. <br />T = TAMPER RESISTANT. <br />TL = TWIST LOCK. <br />WP = WEATHERPROOF. <br />Cp SINGLE RECEPTACLE ON NORMAL CIRCUIT. <br />DUPLEX RECEPTACLE ON NORMAL CIRCUIT. <br />CEILING MOUNTED DUPLEX RECEPTACLE ON NORMAL CIRCUIT. <br />DOUBLE DUPLEX RECEPTACLE ON NORMAL CIRCUIT. <br />`It' DUPLEX GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE ON NORMAL <br />CIRCUIT. <br />fXX-XXR SPECIAL PURPOSE RECEPTACLE WITH NEMA CONFIGURATION TO MATCH <br />EQUIPMENT. <br />JOY JUNCTION BOX. <br />U2 DUPLEX RECEPTACLE (TAMPER RESISTANT) W/ (1) USB TYPE A PORT AND (1) <br />USB TYPE C PORT. <br />U4 DUPLEX RECEPTACLE (TAMPER RESISTANT) W/ (2) USB TYPE A PORTS AND (2) <br />USB TYPE C PORTS. <br />F-B1 # FLOOR BOX; REFER TO FLOOR BOX DEVICE SCHEDULE FOR ADDITIONAL <br />INFORMATION. <br />FF # FURNITURE FEED DEVICE; REFER TO FURNITURE FEED DEVICE SCHEDULE FOR <br />ADDITIONAL INFORMATION. <br />SURFACE METAL RACEWAY, EQUAL TO WIREMOLD SERIES 3000. PROVIDE <br />WITH RECEPTACLES AS INDICATED ON PLANS WITH ACCESSORIES (ELBOWS, <br />COVERS, COUPLINGS, ETC.) FOR A CONTINUOUS, COMPLETE INSTALLATION. <br />COLOR BY ARCHITECT, IVORY OR GRAY. <br />SURFACE METAL RACEWAY, EQUALTO WIREMOLD SERIES 4000. PROVIDE <br />WITH RECEPTACLES AND TECHNOLOGY OUTLETS AS INDICATED ON PLANS <br />WITH ACCESSORIES (ELBOWS, COVERS, COUPLINGS, DIVIDERS, ETC.) FOR A <br />CONTINUOUS, COMPLETE INSTALLATION. COLOR BY ARCHITECT, IVORY OR <br />GRAY. <br />PLUGMOLD. <br />El ❑P -I POWER FURNITURE FEED. <br />EMGB ELECTRICAL MAIN GROUNDING BUSBAR. <br />SPD SURGE PROTECTIVE DEVICE. <br />LIGHTING FIXTURE LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />A LIGHT FIXTURE (LUMINAIRE) ON NORMAL CIRCUIT. LETTER INDICATES TYPE. <br />®a SUBSCRIPT INDICATES CONTROL AND CIRCUIT NUMBER. <br />AE LIGHT FIXTURE (LUMINAIRE) TO BE PROVIDED WITH INTEGRAL BATTERY <br />®a BACKUP. LETTER INDICATES TYPE. SUBSCRIPT INDICATES CONTROL AND CIRCUIT <br />NUMBER. <br />o-p SITE LIGHT FIXTURE (LUMINAIRE). REFER TO POLE BASE DETAIL. <br />®� EXIT SIGN, ONE OR TWO FACED. ARROWS DENOTE DIRECTION. SHADING <br />DENOTES NUMBER AND ORIENTATION OF SIGN FACE(S). <br />EXIT SIGN WITH EMERGENCY LIGHTS. ARROWS DENOTE DIRECTION. SHADING <br />DENOTES NUMBER AND ORIENTATION OF SIGN FACE(S). <br />EMERGENCY LIGHTING BATTERY UNIT WITH EMERGENCY LIGHTS <br />EMERGENCY LIGHTING BATTERY UNIT WITH EMERGENCY LIGHTS AND REMOTE <br />CAPACITY <br />Ak REMOTE EMERGENCY HEAD <br />_INV_j INVERTER. <br />POWER DISTRIBUTION LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />® 480Y/277 VOLT PANELBOARD, SURFACE MOUNTED, REFER TO SCHEDULE OF <br />PANELBOARDS. <br />480Y/277 VOLT PANELBOARD, FLUSH MOUNTED, REFER TO SCHEDULE OF <br />PANELBOARDS. <br />208Y/120 VOLT PANELBOARD, SURFACE MOUNTED, REFER TO SCHEDULE OF <br />PANELBOARDS. <br />= 208Y/120 VOLT PANELBOARD, FLUSH MOUNTED, REFER TO SCHEDULE OF <br />PANELBOARDS, <br />METER SOCKET AND UTILITY COMPANY ELECTRIC METER, OR AS NOTED. <br />0 ENCLOSED CIRCUIT BREAKER. <br />LIGHTING CONTROL LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />Sa SINGLE POLE SWITCH. SUBSCRIPT INDICATES LIGHT FIXTURE CONTROL. <br />120V ASTRONOMICAL TIME SWITCH WITH OILED DISPLAY, EQUALTO <br />STCa WATTSTOPPER #RT-200,MOUNTED AT 48" A.F.F TO CENTER. SUBSCRIPT <br />INDICATES LIGHT FIXTURE CONTROL. <br />SWSa WATTSTOPPER #DSW-301 OCCUPANCY SENSOR, WALL MOUNTED AT 48" A.F.F. <br />CEILING MOUNTED PHOTOSENSOR FOR DAY LIGHT HARVESTING. EQUAL TO <br />WATTSTOPPER #LMLS-500. PHOTOSENSOR PLACEMENT PER MANUFACTURER'S <br />RECOMMENDED LOCATIONS. PLACEMENT ON FLOOR PLANS IS <br />DIAGRAMMATICAL. <br />CEILING MOUNTED DIGITAL DUALTECHNOLOGY OCCUPANCY SENSOR, PASSIVE <br />INFRARED AND ULTRASONIC TECHNOLOGY, EQUAL TO WATTSTOPPER <br />#LMDC-100, PROVIDE WITH POWER PACK. MOUNT AT LEAST 6-0" FROM A <br />SUPPLY REGISTER. LOWER CASE LETTER INDICATES SWITCH CONTROL. TIME <br />OS a DELAY SHALL BE 15 MINUTES. POWER PACK SHALL BE LOCATED ABOVE <br />CEILING, ABOVE SENSOR. MOUNT OCCUPANCY SENSOR AT SAME HEIGHT OR <br />BELOW ANY PENDANT MOUNTED LIGHTING FIXTURES SO AS TO NOT <br />OBSTRUCT OCCUPANCY SENSOR. <br />WALL/CORNER MOUNTED DIGITAL DUAL TECHNOLOGY OCCUPANCY SENSOR, <br />PASSIVE INFRARED AND ULTRASONIC TECHNOLOGY, EQUAL TO WATTSTOPPER <br />#LMDX-100, PROVIDE WITH POWER PACK. MOUNT AT LEAST 6'-0" FROM A <br />SUPPLY REGISTER. LOWER CASE LETTER INDICATES SWITCH CONTROL. TIME <br />Ha DELAY SHALL BE 15 MINUTES. POWER PACK SHALL BE LOCATED ABOVE <br />CEILING, ABOVE SENSOR. MOUNT OCCUPANCY SENSOR AT SAME HEIGHT OR <br />BELOW ANY PENDANT MOUNTED LIGHTING FIXTURES SO AS TO NOT <br />OBSTRUCT OCCUPANCY SENSOR. <br />TC TIMECLOCK <br />TELECOMMUNICATION LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />TELECOMMUNICATION OUTLETS: <br />COORDINATE ALL LOCATIONS AND MOUNTING HEIGHTS WITH OWNERS AND <br />TELECOMMUNICATIONS VENDOR PRIOR TO ROUGH -IN; MOUNT VERTICAL <br />OUTLETS AT 18"A.F.F. TO CENTER UNLESS OTHERWISE DIRECTED. THE <br />DESIGNATIONS SHALL APPLY TO ALL OUTLET TYPES: <br />C = INDICATES MOUNTED AT 6" ABOVE BACK SPLASH TO BOTTOM, <br />REFER TO ARCHITECTURAL ELEVATIONS. <br />F = INDICATES FLOOR MOUNTED. <br />P = INDICATES MOUNTED AT 47" A.F.F. <br />W = INDICATES MOUNTED AT 54" A.F.F. <br />H - INDICATES MOUNTED AT 82" A.F.F. <br />TELECOMMUNICATIONS OUTLET, REFER TO TELECOMMUNICATIONS <br />FACEPLATE DETAIL FOR ADDITIONAL INFORMATION. <br />WIRELESS ACCESS POINT. CEILING OR WALL MOUNTED. REFER TO <br />TELECOMMUNICATIONS FACEPLATE DETAIL FOR ADDITIONAL INFORMATION. <br />❑D ❑D -I TELECOMMUNICATIONS FURNITURE FEED. <br />MGB MAIN TELECOMMUNICATIONS GROUND BAR, <br />TGB TELECOMMUNICATIONS GROUND BAR. <br />TELECOMMUNICATION TERMINAL BOARD, PROVIDE GRADE "A", 3/4" <br />PLYWOOD COMPLETELY PAINTED WITH FIREPROOF PAINT AS REQUIRED PER <br />CODE. <br />BUILDING GROUNDING GRID LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />GROUND ROD. <br />a <br />G BUILDING GROUND CABLE. <br />EXOTHERMIC BONDING CONNECTION. <br />f� BOLTED BONDING CONNECTION. <br />MOTOR AND CONTROLS LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />SEM BOILER EMERGENCY SWITCH. AROW-HART#CS120 WITH MULLBERRY#41020 <br />PLATE. <br />SINGLE POLE MOTOR RATED SWITCH WITH OVERLOAD HEATER (MANUAL <br />ST MOTOR STARTER). <br />EIJ UN -FUSED DISCONNECT SWITCH WITH RATINGS. <br />30/3/1 <br />�NEMA RATING. "WP" INDICATES RAINTIGHT <br />NUMBER OF POLES <br />SWITCH SIZE <br />01 FUSED DISCONNECT SWITCH WITH RATINGS. <br />30/20/3/DE/1 <br />LNEMA RATING. "WP" INDICATES RAINTIGHT <br />INDICATES DUAL ELEMENT FUSES <br />NUMBER OF POLES <br />FUSE SIZE. %F" INDICATES NON FUSED <br />SWITCH SIZE <br />MOTOR; "3" INDICATES HORSEPOWER RATING. <br />XXX EQUIPMENT TAG, REFER TO MECHANICAL EQUIPMENT SCHEDULE FOR MORE <br />XX INFORMATION. <br />PROJECT: <br />PINCHASERS EAST PASCO <br />ANTHONY PERRONE <br />6816 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />PROJECT NUMBER: 21 161 <br />m <br />MO <br />o <br />C",U <br />oU <br />L1J Q <br />�uj <br />U�u <br />Ov <br />�o <br />W°� <br />O� <br />10 <br />� <br />o <br />C`7 `0 <br />ov <br />� N � <br />w Lri <br />Ln <br />v J = V)00 <br />0 <br />Lo <br />W LL <br />z w. <br />� <br />N <br />Q cV <br />z J <br />ce <br />W Z N <br />w <br />U CO <br />Q o <br />N � <br />O � � <br />`p cct <br />0 0 r,_ 00 <br />M M <br />M <br />♦� O a-, <br />M M <br />Z 0 qO <br />O O <br />U 0 ooc <br />O <br />�Z <br />a <br />M <br />00 <br />STAMP: <br />}�Rfiilfll9wAAlf0f'f �f <br />s <br />FLCR' ` <br />• �Y <br />_1 <br />"'+.��sr+�+•�� <br />ISSUE: <br />DATE: <br />ISSUED FOR PERMIT <br />Ol /25/2023 <br />DRAWING SCALE: NOTED <br />DRAWN BY: SB <br />CHECKED BY: MD <br />DRAWING TITLE: <br />ELECTRICAL - LEGENDS & SYMBOLS <br />DRAWING NUMBER: <br />0,0 <br />