GENERAL DEMOLITION NOTES <br />1. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND <br />DIFFICULTIES THAT WILL AFFECT WORK OF THIS SECTION. RENOVATION WORK WILL <br />REQUIRE CAREFUL SITE EXAMINATION PRIOR TO BIDDING, NO COMPENSATION <br />WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE <br />CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY AN EXPERIENCED <br />OBSERVER. FIELD VERIFY MEASUREMENTS AND CIRCUITING ARRANGEMENTS THAT <br />ARE AS SHOWN ON DRAWINGS. <br />2. FIELD VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY <br />ABANDONED FACILITIES. <br />3. DEMOLITION DRAWINGS ARE BASED ON CASUAL FIELD OBSERVATION AND EXISTING <br />RECORD DOCUMENTS. REPORT DISCREPANCIES TO ARCHITECT/ENGINEER BEFORE <br />DISTURBING EXISTING INSTALLATIONS. THESE DRAWINGS HAVE BEEN COMPILED <br />FROM THE BEST AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE <br />SCOPE OF THE WORK. THE ELECTRICAL CONTRACTOR MAY ENCOUNTER HIDDEN OR <br />COVERED CONDITIONS, NOT INDICATED IN THESE DOCUMENTS, REQUIRING THE <br />ELECTRICAL CONTRACTOR TO PROVIDE ADDITIONAL WORK FOR THE COMPLETION <br />OF HIS OR HER CONTRACT. IT WILL BE ASSUMED THAT THE CONTRACTOR HAS <br />INSPECTED THE SITE PRIOR TO BIDDING AND VERIFIED THE INFORMATION SUPPLIED <br />HEREIN AND ADDITIONAL WORK REQUIRED. BEGINNING OF DEMOLITION MEANS <br />THE CONTRACTOR ACCEPTS EXISTING CONDITIONS. REFER TO ALL CONSTRUCTION <br />DOCUMENTS TO GAIN A COMPLETE UNDERSTANDING OF THE DEMOLITION WORK <br />REQUIRED. <br />4. CUT, REMOVE AND LEGALLY DISPOSE OF SELECTED ELECTRICAL EQUIPMENT, <br />COMPONENTS AND MATERIALS AS INDICATED, INCLUDING, BUT NOT LIMITED TO, <br />REMOVAL OF ELECTRICAL ITEMS INDICATED TO BE REMOVED AND ITEMS MADE <br />OBSOLETE BY THE WORK. DISCONNECT AND REMOVE ALL FIXTURES, WIRING <br />DEVICES, CONDUIT AND FITTINGS, WIRING AND CABLE, FIRE ALARM <br />DEVICES/COMPONENTS, HANGERS, SUPPORTS, WIREWAYS, AND ALL OTHER <br />ELECTRICAL COMPONENTS MADE OBSOLETE BY THIS PROJECT. THE OWNER <br />RESERVES THE OPTION OF SALVAGE RIGHTS TO DEMOLISHED MATERIAL AND <br />REMOVED EQUIPMENT. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER'S <br />REPRESENTATIVE TO OBTAIN A LIST OF MATERIALS AND REMOVED EQUIPMENT TO <br />BE TURNED OVER TO THE OWNER. ALL OTHER MATERIAL AND REMOVED <br />EQUIPMENT NOT BEING SALVAGED BY THE OWNER SHALL BE DISPOSED OF BY THE <br />CONTRACTOR. PLACE ALL DEMOLISHED ELECTRICAL MATERIALS EXCEPT <br />HAZARDOUS MATERIALS (PCB LIGHTING BALLASTS, FLUORESCENT LAMPS, ETC.) AS <br />DETERMINED BY THE AUTHORITY HAVING JURISDICTION IN GENERAL <br />CONTRACTOR'S DUMPSTER. ALL HAZARDOUS ELECTRICAL MATERIALS SHALL BE <br />LEGALLY DISPOSED OF BY THE ELECTRICAL SUBCONTRACTOR. <br />S. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED <br />FOR REMOVAL. <br />6. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN <br />ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS PANELS AS APPROPRIATE. <br />TEMPORARY WALL OPENINGS AND/OR MODIFICATIONS REQUIRED FOR <br />REMOVAL/INSTALLATION OF EQUIPMENT SHALL BE PROVIDED AS NEEDED AND <br />COORDINATED WITH THE GENERAL CONTRACTOR. ALL HVAC, PLUMBING AND FIRE <br />PROTECTION EQUIPMENT SCHEDULED TO BE REMOVED OR RELOCATED SHALL BE <br />DONE SO BY THE HVAC AND PLUMBING CONTRACTOR RESPECTIVELY. THE <br />ELECTRICAL CONTRACTOR SHALL REMOVE STARTERS, DISCONNECT SWITCHES, <br />WIRING, AND CONDUIT FOR SAID EQUIPMENT. REFER TO HVAC AND PLUMBING <br />DRAWINGS FOR SCOPE OF WORK. <br />7. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING <br />SYSTEMS IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED <br />ON ENERGIZED EQUIPMENT OR CIRCUITS USE PERSONNEL EXPERIENCED IN SUCH <br />OPERATIONS. <br />8. EXISTING FIRE ALARM SYSTEM: MAINTAIN THE EXISTING SYSTEM IN SERVICE UNTIL <br />THE MODIFIED/EXPANDED SYSTEM IS TESTED AND ACCEPTED BY THE FIRE <br />DEPARTMENT. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. <br />NOTIFY OWNER, ARCHITECT/ENGINEER AND LOCAL FIRE DEPARTMENT AT LEAST <br />TEN DAYS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE <br />OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN <br />AREAS ADJACENT TO WORK AREA AS REQUIRED OR PROVIDE A "FIRE -WATCH" <br />SYSTEM COORDINATED WITH THE LOCAL FIRE DEPARTMENT. <br />9. EXTEND EXISTING ELECTRICAL INSTALLATIONS AS CALLED FOR ON THE DRAWINGS. <br />10. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE <br />NEW CONSTRUCTION. <br />11. REMOVE ABANDONED WIRING TO SOURCE OF SUPPLY. <br />12. REMOVE EXPOSED ABANDONED CONDUIT, INCLUDING ABANDONED CONDUIT <br />ABOVE ACCESSIBLE CEILING FINISHES. CUT CONDUIT FLUSH WITH WALLS AND <br />FLOORS, AND PATCH SURFACES. <br />13. DISCONNECT ABANDONED OUTLETS AND REMOVE DEVICES. REMOVE ABANDONED <br />OUTLETS IF CONDUIT SERVICING THEM IS ABANDONED AND REMOVED. PROVIDE <br />BLANK COVER FOR ABANDONED OUTLETS WHICH ARE NOT REMOVED. <br />14. DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT SERVING <br />UTILIZATION EQUIPMENT THAT HAS BEEN REMOVED. <br />15. DISCONNECT AND REMOVE ABANDONED LIGHTING FIXTURES. REMOVE BRACKETS, <br />STEMS, HANGERS, AND OTHER ACCESSORIES. <br />16. DISCONNECT AND REMOVE OTHER SYSTEMS AND EQUIPMENT WITHIN THE WORK <br />AREA MADE OBSOLETE BY THIS WORK. <br />17. PROTECT ALL EXISTING WALLS, FLOORS, CEILINGS, LIGHT FIXTURES, ETC, WHICH ARE <br />TO REMAIN AND TO PREVENT DAMAGE DURING ALL CONSTRUCTION PHASES. <br />REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION <br />AND EXTENSION WORK. PROVIDE AND MAINTAIN TEMPORARY PARTITIONS OR <br />DUST BARRIERS ADEQUATE TO PREVENT THE SPREAD OF DUST AND DIRT TO <br />ADJACENTAREAS. PROTECTTHE STRUCTURE, FURNISHINGS, FINISHES, AND <br />ADJACENT MATERIALS NOT INDICATED OR SCHEDULED TO BE REMOVED. PROTECT <br />THE ELECTRICAL WORK AND THE WORK OF OTHERS IN A MANNER BEST SUITED TO <br />THE PARTICULAR CASE. CORRECT ANY DAMAGE DONE TO ANY WORK AT NO <br />ADDITIONAL COST. <br />18. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE <br />WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. <br />19. CLEAN AND REPAIR EXISTING MATERIALS AND EQUIPMENT WHICH REMAIN OR ARE <br />TO BE REUSED. <br />20, PANELBOARDS: CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL <br />CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE <br />PLATES FOR VACANT POSITIONS. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING <br />REVISED CIRCUITING ARRANGEMENT. <br />21. LIGHTING FIXTURES: EXISTING LIGHTING FIXTURES SCHEDULED FOR REUSE SHALL BE <br />REMOVED FOR CLEANING. USE MILD DETERGENT TO CLEAN ALL EXTERIOR AND <br />INTERIOR SURFACES; RINSE WITH CLEAN WATER AND WIPE DRY. REPLACE LAMPS, <br />BALLASTS AND BROKEN ELECTRICAL PARTS. <br />22. EXISTING ELECTRICAL EQUIPMENT AND WIRING NOT SHOWN ON DOCUMENTS OR <br />ADDRESSED BY NOTES ABOVE SHALL BE CONSIDERED EXISTING TO REMAIN. <br />EXISTING ELECTRICAL EQUIPMENT LEGEND <br />ALL ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT <br />�F 0 <br />EXISTING ELECTRICAL EQUIPMENT WITHOUTA DESIGNATION IS TO REMAIN. <br />XE XE XE XE <br />"XE" INDICATES EXISTING ELECTRICAL EQUIPMENT WHICH IS TO BE REMOVED. <br />LFJ 2 0 P <br />PULL BACK WIRING AND CONDUIT BACK TO NEXT ACTIVE OUTLET OR POWER <br />SOURCE. <br />XR XR XR <br />"XR" INDICATES EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED AND <br />M 2 XR I1TI <br />RELOCATED. EXISTING CIRCUIT SHALL BE EXTENDED TO NEW LOCATION OF <br />tY <br />RELOCATED EXISTING ELECTRICAL EQUIPMENT. <br />XNXNXNXN XN <br />2 7 [P <br />"XN" INDICATES NEW LOCATION OF RELOCATED EXISTING ELECTRICAL <br />EQUIPMENT. <br />"ETR" INDICATES EXISTING EQUIPMENT/DEVICE TO REMAIN. EXISTING CIRCUIT/ <br />ETR ETR ETR ETR <br />WIRING SHALL BE REMOVED. PULL BACK WIRING AND CONDUIT BACK TO NEXT <br />I F 27 IP <br />ACTIVE OUTLET OR POWER SOURCE. ALL HVAC/PLUMBING INTERLOCKING <br />WIRING SHALL REMAIN, REFER TO RENOVATION PLANS FOR NEW CIRCUIT <br />INFORMATION. <br />�XW, XW XW XW <br />"XW" INDICATES EXISTING EQUIPMENT/DEVICE TO BE REMOVED. EXISTING <br />M 2 01P <br />CIRCUIT/WIRING AND BACK BOX SHALL REMAIN. NEW DEVICE SHALL BE <br />XW XW XW XW <br />LOCATED IN PLACE. EXTEND CIRCUIT/WIRING TO NEW ELECTRICAL <br />nQ 0 qp <br />EQUIPMENT/DEVICE. <br />GENERAL NOTES: <br />1. DOTTED SYMBOLS <br />INDICATE EXISTING ELECTRICAL EQUIPMENT. <br />2. REFER TO <br />SPECIFICATIONS FOR ADDITIONAL INFORMATION. <br />3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THE CONTINUITY OF ALL <br />EXISTING CIRCUITS WHICH ARE REMAINING. <br />CLG <br />ETR <br />fr 1 <br />r TIfT -1- <br />f- T►fr 1 <br />r -nfr 1 <br />U_J <br />-1 <br />L1JLLJ - R/F <br />-nrr <br />L1JU-J <br />­1fr <br />L_LILJ <br />fr <br />r 1 <br />r 1 <br />f--nfr 1 <br />LL J <br />L _UU_ J <br />L _UH J <br />L 1JLL J <br />CIRCUIT TRACING NOTE <br />ELECTRICAL CONTRACTOR SHALL UPDATE ALL EXISTING PANELBOARD DIRECTORIES TO <br />REFLECT ALL CIRCUITS MADE SPARE FROM DEMOLITION. ALL EXISTING CIRCUIT BREAKERS IN <br />ALL EXISTING PANELBOARDS SHOWN ON THE DRAWINGS SHALL BE TRACED OUT AND LABELED <br />IN PANELBOARD OF ORIGIN. ALL CIRCUITS THAT ARE NO LONGER IN USE SHALL BE PULLED <br />BACK TO PANEL OF ORIGIN. ALL CIRCUIT BREAKERS NOT BEING UTILIZED SHALL BE LABELED AS <br />SPARE AND PUT IN THE OPEN (OFF) POSITION. <br />KEYED NOTES <br />r1 DISCONNECT AND THEN RECONNECT EXISTING CEILING MOUNTED RECEPTACLES TO <br />�� ACCOMMODATE NEW CEILING. <br />ETR <br />_,I -nrr 1 <br />rir�r —Ji <br />L 1JLL J <br />CLG <br />ETR , y; <br />r� —1 <br />Uk <br />r-11T 1 <br />TR <br />r -nrr - <br />r -nrr —1 <br />L SJLL J <br />r-nfT1 <br />L JL -i > <br />rTfT1-._: R/F <br />L _LILL. J <br />rilfr1 <br />L11LL.J <br />LIILLJ <br />L1IlLJ <br /><�� �> <br /><�� �J,> <br /><�� �J,> <br />CLG CLG <br />ETR .._') ETR <br />uR <br />F-"f11T-1 <br />TR <br />r- -nff-4 , <br />F -nfT-1 <br />L11LL.J <br />r -1fr 1 <br />L HLL. jal <br />r -nfr - R/F <br />LJLLJ <br />r ilfr-1 <br />LIJLLJ <br />L_ULJ <br />L HU_J <br />ET <br />r ilff -1 <br />� -nrr -1 <br />L _LI L J <br />L I IU_ J <br />i -11 <br />i- i <br />P <br />�a <br />U <br />U <br />I <br />r-n(T1 <br />r�1fr-1ETR <br />rT1fT1 <br />rTI <br />L 1JLL J <br />L 1JL J <br />L 1JLL J <br />L 11 <br />r Tif -1 <br />r -nfr 1_ ___ R/F <br />r TIIT 1 <br />r it <br />L _LILI_n <br />n_ULI_n <br />n_UULn <br />/L_LI ETR <br />ETR CLG <br />CLG <br />CLG <br />CLG CLG <br />CLG <br />ETR ETR , <br />ETR l,: <br />ETR _ <br />0 ETR ETR .: <br />ETR , <br />ETR <br />ETR <br />ETR <br />ETR <br />ETR <br />CLG <br />ETR ETR <br />ETR' <br />EXISTING MAIN ELECTRIC ROOM EQUIPMENT <br />IS EXISTING TO REMAIN. <br />ETR <br />ETR <br />ETR <br />ETR <br />ETR <br />ETR <br />R/F <br />ETR <br />;ETR ETR ETR ETR <br />f, - - - - - ------ - - - --------- <br />-_ --_- ______ -- - - - - - - - - <br />�I <br />XE XE <br />j XE I 1 <br />------------------------ <br />El°R� L---------------------------.li I IU <br />ETR <br />R/F i <br />ETR - <br />I � T <br />-------`i �-------= — <br />�;.__� ETR - - - -I r <br />i r <br />II <br />I <br />ETR I I XE XE IL - - - - - - - - - <br />- - - - - - - - - ETR <br />I II <br />R/F R <br />I <br />I XEI ETR <br />-JETR XE._ L_--------J ETR E <br />------ <br />ETR - R/F - ETR - R/F <br />ETR ETR ETR ETR" - -- R/F <br />T <br />` �i <br />ELECTRICAL DEMOLITION <br />SCALE:1/8" =1'-0" <br />0 8' 0' 16'-0" 24'-0" <br />ETR <br />ETR <br />ETR <br />'R/F <br />ETR <br />ETR <br />ETR <br />ETR <br />ETR <br />ETR_` <br />ETR- <br />ETR' <br />ETR <br />PROJECT: <br />PINCHASERS EAST PASCO <br />ANTHONY PERRONE <br />6816 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33542 <br />PROJECT NUMBER: 21161 <br />(jr) <br />00 <br />NU <br />. <br />o LU <br />WqU <br />LU <br />U�� <br />� <t <br />J O U <br />ce o <br />W°� <br />O�' <br />w <br />I _ o <br />(y) `o <br />ov <br />w in <br />I— u0 <br />r <br />�/ V) v <br />V)"T <br />0 <br />F_ Lo <br />w u- <br />w U w <br />N <br />N N <br />Z qN <br />y w r <br />I. <br />LJ_J Z N <br />w <br />U 00 <br />Q o <br />N L7 <br />cy) <br />F <br />V _s4 o <br />0 <br />^, H M M <br />M <br />V/ <br />40, <br />a C) ccn <br />Q 0 00 00 O <br />U <br />1� 4� <br />N <br />O 0PLO <br />m 00 <br />STAMP: <br />.- <br />ISSUE: <br />DATE: <br />ISSUED FOR PERMIT <br />01 /25/2023 <br />DRAWING SCALE: NOTED <br />DRAWN BY: SB <br />CHECKED BY: MD <br />DRAWING TITLE: <br />ELECTRICAL - DEMOLITION <br />DRAWING NUMBER: <br />ED 1,90 <br />