My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7320 Gall Blvd (8)
Zephyrhills
>
Building Department
>
Building Plans
>
7320 Gall Blvd (8)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:32:34 PM
Creation date
2/19/2025 2:14:41 PM
Metadata
Fields
Template:
Building Plans
Street #
7320
Location
Gall Blvd
Contractor
Hawkins Const
Building Plans - Permit #
8662B
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL ABBREVIATIONS <br />A I <br />A/C <br />AIR CONDITIONING <br />ID <br />INSIDE DIAMETER <br />AC <br />ALTERNATING CURRENT <br />IE <br />INVERT ELEVATION <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />IN <br />INCHES <br />_ <br />AD <br />AREA DRAINS <br />INFO <br />INFORMATION <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />INT <br />INTERIOR OR INTERNAL <br />ADAAG <br />AMERICANS WITH DISABILITIES ACT <br />INV <br />INVERT <br />ACCESSIBILITIES GUIDELINES <br />IP <br />IRON PIPE <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />J <br />AHU <br />AIR HANDLING UNIT <br />JAN <br />JANITOR <br />AISC <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />JT <br />JOINT <br />AL, ALUM <br />ALUMINUM <br />AL <br />ALTERNATE <br />K <br />ANSI <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />K <br />KIPS <br />AP <br />ACCESS PANEL <br />KSI <br />KIPS PER SQUARE INCH <br />APPROX <br />APPROXIMATELY <br />D <br />APVD <br />APPROVED <br />L <br />ASHRAE <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION <br />AND AIR CONDITIONING ENGINEERS <br />L <br />LAB <br />LENGTH <br />LABEL <br />ASME <br />AMERICAN SOCIETY OF MECHANICAL ENGINEERS <br />GAT <br />LATERAL <br />ASPH <br />ASPHALT <br />ASTM <br />AMERICAN SOCIETY FOR TESTING AND MATERIALS <br />LBS <br />POUNDS <br />GF <br />LINEAR FEET <br />B <br />LL <br />LIVE LOAD <br />LLH <br />LONG LEG HORIZONTAL <br />BD <br />BOARD <br />LLV <br />LONG LEG VERTICAL <br />BLDG <br />BUILDING <br />LONG <br />LONGITUDINALLG <br />BM <br />BEAM OR BENCH MARK <br />LAMINATED GLASS <br />BOC <br />BOTTOM OF CONDUIT <br />LP <br />LOW POINT <br />` <br />BOD <br />BOTTOM OF DUCT <br />LTG <br />LIGHTING <br />BOF <br />BOTTOM OF FOOTING <br />BOP <br />BOTTOM OF PIPE <br />M <br />BOS <br />BOTTOM OF STEEL <br />MAINT <br />MAINTENANCE <br />BOT <br />BOTTOM <br />MATL <br />MATERIAL <br />BP <br />BASE PLATE <br />MAX <br />MAXIMUM <br />C <br />MECH <br />MECHANICAL <br />MED <br />MEDIUM <br />C <br />DEGREES CELSIUS <br />MET <br />METAL <br />CALC <br />CALCULATE <br />MEZZ <br />MEZZANINE <br />CAT <br />CATALOG <br />MFG <br />MANUFACTURING <br />CB <br />CATCH BASIN <br />MFR <br />MANUFACTURER <br />- <br />CF <br />CUBIC FOOT OR FEET <br />MH <br />MANHOLE <br />CFH <br />CUBIC FEET PER HOUR <br />MIL <br />THOUSANDTH OF AN INCH <br />CFM <br />CUBIC FEET PER MINUTE <br />MIN <br />MINIMUM <br />Cl <br />CURB INLET OR CAST IRON <br />MISC <br />MISCELLANEOUS <br />CJ <br />CONTROL JOINT <br />MK <br />MARK <br />CJNT <br />CONSTRUCTION JOINT <br />MM <br />MILLIMETERS <br />CL <br />CENTERLINE <br />MO <br />MASONRY OPENING <br />CLG <br />CEILING <br />MPH <br />MILES PER HOUR <br />CLO <br />CLOSET <br />MT <br />MOUNT <br />CLR <br />CLEAR <br />MTD <br />MOUNTED <br />CMP <br />CORRUGATED METAL PIPE <br />CMU <br />CONCRETE MASONRY UNIT <br />N <br />CO <br />CLEAN OUT <br />N <br />NORTH <br />C <br />COL <br />COLUMN <br />N/A <br />NOT APPLICABLE <br />CONIC <br />CONCRETE <br />NEC <br />NATIONAL ELECTRIC CODE <br />CONST <br />CONSTRUCTION <br />NEG <br />NEGATIVE <br />CONT <br />CONTINUOUS <br />NEMA <br />NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION <br />CONTR <br />CONTRACTOR <br />NF <br />NEAR FACE <br />CORR <br />CORRIDOR <br />NFPA <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />CPT <br />CARPET <br />NOM <br />NOMINAL <br />CT <br />CERAMIC TILE <br />NIC <br />NOT IN CONTRACT <br />CTR <br />CENTER <br />NO,# <br />NUMBER <br />CU FT <br />CUBIC FOOT OR FEET <br />NTS <br />NOT TO SCALE <br />CU YD <br />CUBIC YARD(S) <br />CW <br />COLD WATER <br />0 <br />R <br />CY <br />CUBIC YARD(S) <br />- <br />OC <br />ON CENTER <br />D <br />OD <br />OUTSIDE DIAMETER OR OVERFLOW DRAIN <br />DEG <br />DEGREE <br />OF <br />OUTSIDE FACE <br />DEMO <br />DEMOLITION <br />OPNG <br />OPENING <br />DET <br />DETAIL <br />OZ <br />OUNCE <br />DF <br />DRINKING FOUNTAIN <br />P <br />DIA <br />DIAMETER <br />DIAL <br />DIAGONAL <br />PCF <br />POUNDS PER CUBIC FOOT <br />DL <br />DEAD LOAD <br />PH <br />PHASE <br />DN <br />DOWN <br />PHYS <br />PHYSICAL <br />DWG <br />DRAWING <br />PL <br />PLATE, PLASTIC <br />DWG <br />DOWEL <br />PLAM <br />PLASTIC LAMINATE <br />PLBG <br />PLUMBING <br />E <br />PLF <br />POUNDS PER LINEAR FOOT <br />E <br />EAST <br />PLYWD <br />PLYWOOD <br />EA <br />EACH <br />PMJ <br />PRE -MOLDED JOINT <br />EF <br />EACH FACE <br />PMP <br />PUMP <br />EIFS <br />EXTERIOR INSULATION FINISH SYSTEM <br />PNL <br />PNT <br />PANEL <br />PAINT <br />EJ <br />EXPANSION JOINT <br />POS <br />POSITIVE OR POSITION <br />EL <br />REFERENCE ELEVATION <br />PR <br />PAIR <br />ELEV <br />ELEVATOR OR ELEVATION <br />PREFAB <br />PREFABRICATED <br />_ <br />EMER <br />EMERGENCY <br />PRESS <br />PRESSURE <br />ENCL <br />ENCLOSURE <br />PSF <br />POUNDS PER SQUARE FOOT <br />ENGR <br />ENGINEER, ENGINEERING <br />PSI <br />POUNDS PER SQUARE INCH <br />B <br />EOS <br />EDGE OF SLAB <br />PTD <br />PAINTED <br />EPA <br />ENVIRONMENTAL PROTECTION AGENCY <br />PTD <br />PARTITION <br />EQUIP <br />EQUIPMENT <br />PT <br />PRESSURE TREATED <br />EST <br />ESTIMATE <br />ETC <br />ET CETERA <br />Q <br />EW <br />EACH WAY <br />EWC <br />ELECTRIC WATER COOLER <br />QT <br />QUARRY TILE <br />y <br />EX, EXIST <br />EXISTING <br />QTY <br />QUANTITY <br />EXT <br />EXTERIOR <br />QUAL <br />QUALITY <br />F <br />R <br />F <br />DEGREES FAHRENHEIT <br />R <br />RADIUS, RISER OR RED <br />FACBC <br />FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION <br />RA <br />RETURN AIR <br />FD <br />FLOOR DRAIN OR FIRE DAMPER <br />RD <br />ROOF DRAIN <br />FDN <br />FOUNDATION <br />REBAR <br />REINFORCING STEEL BAR <br />FE <br />FIRE EXTINGUISHER <br />REC <br />RECESSED <br />FEC <br />FIRE EXTINGUISHER CABINET <br />REF <br />REFERENCE <br />FF <br />FAR FACE <br />REFRIG <br />REFRIGERATION <br />FIG <br />FINISHED GRADE <br />REINF <br />REINFORCED OR REINFORCEMENT <br />FH <br />FIRE HYDRANT <br />REQ'D <br />REQUIRED <br />FHC <br />FIRE HOSE CABINET <br />REQM'T <br />REQUIREMENT <br />FL <br />FLOW LINE <br />REV <br />REVISION <br />FLEX <br />FLEXIBLE <br />RH <br />RIGHT HAND <br />FM <br />FACTORY MUTUAL <br />RM <br />ROOM <br />FRP <br />FIBERGLASS REINFORCED POLYESTER PANELS <br />RMT <br />REMOTE <br />FT <br />FOOT OR FEET <br />RO <br />ROUGH OPENING <br />FTG <br />FOOTING OR FITTING <br />S <br />FV <br />FIELD VERIFY <br />FVC <br />FIRE VALVE CABINET <br />S <br />SOUTH <br />SAN <br />SANITARY <br />G <br />SBC <br />STANDARD BUILDING CODE <br />- <br />GA <br />GAUGE <br />SCHED <br />SCHEDULE OR SCHEDULED <br />GAL <br />GALLONS <br />SCHEM <br />SCHEMATIC <br />GALV <br />GALVANIZED <br />SECT <br />SECTION <br />GB <br />GRADE BEAM OR GRAB BAR <br />SFBC <br />SOUTHERN FLORIDA BUILDING CODE <br />GC <br />GENERAL CONTRACTOR <br />SHT <br />SHEET <br />GEN <br />GENERAL OR GENERATOR <br />SMACNA <br />SHEET METAL AND AIR CONDITIONING <br />A <br />GHM <br />GALVANIZED HOLLOW METAL <br />CONTRACTOR'S NATIONAL ASSOCIATION <br />GI <br />GALVANIZED IRON <br />SMC <br />STANDARD MECHANICAL CODE <br />GPM <br />GALLONS PER MINUTE <br />SPA <br />SPACE <br />GWB <br />GYPSUM WALLBOARD <br />SPC <br />STANDARD PLUMBING CODE <br />GYP <br />GYPSUM <br />SPEC <br />SPECIFICATION(S) <br />SQ <br />SQUARE <br />H <br />SO FT, SF <br />SQUARE FEET <br />SS <br />STAINLESS STEEL <br />HAZ <br />HAZARDOUS <br />SSD <br />SUBSOIL DRAIN <br />HB <br />HOSE BIBB <br />STC <br />SOUND TRANSMISSION CLASS <br />HDW <br />HARDWARE <br />STD <br />STANDARDSTL <br />HORIZ <br />HORIZONTAL <br />STEEL <br />HM <br />HOLLOW METAL <br />STOR <br />STORAGE <br />HP <br />HIGH POINT OR HORSEPOWER <br />STRUCT <br />STRUCTURE OR STRUCTURAL <br />HR <br />HOUR <br />HT <br />HEIGHT <br />HTR <br />HEATER <br />HVAC <br />HEATING VENTILATION AND AIR CONDITIONING <br />HW <br />HOT WATER <br />T <br />T&B <br />TOP AND BOTTOM <br />T&G <br />TONGUE AND GROOVE <br />TBD <br />TO BE DETERMINED <br />TECH <br />TECHNICAL <br />TEL <br />TELEPHONE <br />THK <br />THICK <br />TOBB <br />TOP OF BOND BEAM <br />TOC <br />TOP OF CONCRETE <br />TOD <br />TOP OF DUCT <br />TOF <br />TOP OF FOOTING <br />TOS <br />TOP OF STEEL <br />TOW <br />TOP OF WALL <br />TP <br />TOP OF PAVEMENT <br />TSTG <br />TESTING <br />TYP <br />TYPICAL <br />U <br />UC <br />UNDERCUT <br />UL <br />UNDERWRITER'S LABORATORIES <br />UNO <br />UNLESS NOTED OTHERWISE <br />UPS <br />UNINTERRUPTABLE POWER SUPPLY <br />UTIL <br />UTILITY <br />V <br />V <br />VOLTS <br />VCT <br />VINYL COMPOSITION TILE <br />VEL <br />VELOCITY <br />VERT <br />VERTICAL <br />VEST <br />VESTIBULE <br />VIF <br />VERIFY IN FIELD <br />VTR <br />VENT THROUGH ROOF <br />VWC <br />VINYL WALL COVERING <br />W <br />W <br />WATTS, WEST OR WIDTH <br />W/ <br />WITH <br />WC <br />WATER CLOSET <br />WD <br />WOOD <br />W/0 <br />WITHOUT <br />WP <br />WORKING POINT <br />WR <br />WATER RESISTANT <br />WS <br />WATER STOP <br />WT <br />WEIGHT <br />WWF <br />WELDED WIRE FABRIC <br />Y <br />YD YARD (S) <br />GENERAL SYMBOLS <br />BREAK LINE SYMBOL <br />AA COLUMN GRID DESIGNATION <br />10 DEMOLITION NOTE SYMBOL <br />xxx DOOR SYMBOL <br />XX WINDOW SYMBOL <br />00000 FLOOR FINISH SYMBOL <br />X-X WALL FINISH SYMBOL <br />/ ' \ REVISION SYMBOL <br />11 NOTE SYMBOL <br />N PLAN NORTH <br />NORTH ARROW <br />TRUE NORTH <br />01 PARTITION TYPE <br />ROOM NAME ROOM NAME AND NUMBER <br />101A <br />Al DETAIL, ELEVATION OR SECTION BUBBLE <br />A101 - LOCATOR/DESCRIPTOR (Al) <br />- SHEET NUMBER WHERE SHOWN (A101) <br />ZA SECTION CUT ARROW <br />Al - LOCATOR/DESCRIPTOR (Al) <br />A101 - SHEET NUMBER WHERE SHOWN (A101) <br />DETAIL BUBBLE <br />_ - LOCATOR/DESCRIPTOR (Al) <br />Al - SHEET NUMBER WHERE SHOWN (A101) <br />A101 i <br />Al ELEVATION BUBBLE <br />A101 - LOCATOR/DESCRIPTOR (Al) <br />- SHEET NUMBER WHERE SHOWN (A101) <br />Al DRAWING TITLE <br />�01%g"=1'-0" DRAWING AND DETAIL TITLE <br />- DRAWING TITLE <br />- DRAWING DESIGNATION (Al) <br />- SHEET NUMBER WHERE DRAWN (A101) <br />- DRAWING SCALE <br />+10'-0" AFF ELEVATION REFERENCE TARGET ON PLAN VIEWS <br />TOP OF COLUMN ELEVATION OR SECTIONS REFERENCE <br />12'-0" TARGET ON ELEVATIONS <br />ADDENDA BUBBLE <br />CENTER LINE SYMBOL <br />R <br />PLATE SYMBOL <br />NEW STUD WALLS WITH <br />SOUND BATT INSULATION <br />NEW STUD WALLS WITHOUT <br />SOUND BATT INSULATION <br />Hill <br />NEW CONCRETE BLOCK WALLS <br />• • • <br />UL 1 HOUR FIRE RATED WALL FROM SLAB TO <br />STRUCTURE ABOVE <br />© <br />UL 2 HOUR FIRE RATED WALL FROM SLAB TO <br />STRUCTURE ABOVE <br />— - — - — - — - — - <br />COOLER WALL ARMOR <br />ESTIMATED EGRESS <br />PATH DISTANCE <br />EXISTING EXIT DOOR #130 EXISTING EXIT DOOR #114A <br />EXIT WIDTH = 32'' EXIT WIDTH = 32" <br />EXIT CAPACITY = 160 PEOPLE Q Q — _ Q Q EXIT CAPACITY = 160 PEOPLE <br />1— - —- -— - - - - -— -- — — — — — - - - - - - - - - - - - - - -— — — <br />I <br />EXISTING EXIT DOOR # 132 <br />EXIT WIDTH = 32'' <br />EXIT CAPACITY = 160 PEOPLE <br />Il L ------------ — ----- <br />� j <br />EXISTING <br />STAIR <br />UP <br />♦ \�'--------- 134'-5�� <br />�, —L---- ----- - - - - -I <br />♦ 151-9 r ------ —I— <br />II-----I ----�------------- �---------I <br />-r fi- <br />I <br />II <br />I <br />I II I I I I I I II <br />fl— <br />I I I I I 1 1 II <br />II <br />I I I II <br />I II I' I I I I 1 1 II <br />I ' <br />11 <br />E- -- - -- - - -- - - - --- - - - - - --$ - --- �- <br />I <br />I 11 I 1 1 I I I I I <br />II 11 j I I I II <br />II i I I I I I I II <br />II I I I I 11 <br />ROJRCENT 11 <br />' <br />ET' <br />STORE <br />— — — — — — I — — — — — — — — — — <br />---------- - <br />------- _ _ ----I---- ---� <br />I <br />II I I I I I I I I I <br />� I II I I II II I II I <br />i I �I 6 I� 7 1 8 9 11 I I �� <br />0 <br />IIILI�L <br />II III I I II I � <br />-- _--14— — — orlEXIST fN1 II II II <br />SLOPE L20 <br />ROJRCENT <br />RETR <br />STORE <br />EXISTING EXIT DOOR #110C <br />EXIT WIDTH = 32'' <br />EXIT CAPACITY = 160 PEOPLE <br />— — — — — — — I MEZZ,4NIN — — <br />00 T UP <br />165'I7�� <br />_ ----- - - _150_15' _ <br />I � I <br />EXISTING EXIT _ FACBC UPMEZZANNEG FACBC EXISTING EXIT <br />A COMPLIANT I DOOR 101E <br />DOOR #101A I C�OM>SLtANT-- --------------- -- - - - -- ---------- - - - - # <br />EXIT WIDTH = 105 RAMPDN RAM DN EXIT WIDTH = 105'' <br />EXIT CAPACITY = 525 PEOPLE 0 NQ 0Q EXIT CAPACITY = 525 PEOPLE <br />(BREAKAWAY DOORS) 'g� (BREAKAWAY DOORS) <br />CODE ANALYSIS <br />GENERAL INFORMATION <br />SUMMARY: <br />EXISTING FACILITY IS A SINGLE STORY METAL FRAME STRUCTURE WITH NON-COMBUSTIBLE <br />CONCRETE BLOCK EXTERIOR WALLS, AND INSULATED ROOFING SYSTEM. <br />RENOVATION OF EXISTING STRUCTURE COMPRISED OF INTERIOR WALLS, CEILINGS AND FINISHES. <br />BUILDING GROSS FLOOR AREAS: <br />EXISTING STORE: 42,112 SQ FT <br />EXISTING MEZZANINE: 1,216 SO FT <br />TOTAL AREA: 43,328 SO FT <br />APPLICABLE BUILDING CODES: <br />STANDARD BUILDING CODE 1997 <br />NFPA 101 (1997) <br />FACBC (1997) <br />OCCUPANCY CLASSIFICATION: <br />GROUP M (MERCANTILE) <br />CONSTRUCTION TYPE: <br />TYPE IV - UNPROTECTED FULLY FIRE SPRINKLERED. <br />OCCUPANT LOAD CALCULATIONS <br />SALES AREA NOT SHADED <br />Occupant Load Per Table 1003.1 - SBC <br />Sales Area: 30 Gross SF Per Occupant (Occupant Factor O.F.) <br />AREA GROSS SF 0. F. OCCUPANTS <br />MERCANTILE: 28,903 30 964 <br />(Grade floor areas open to public) <br />BUSINESS AREA <br />Minimum Occupant Load Per Table 1003.1 - SBC <br />Business Area: 100 Gross SF Per Occupant (Occupant Factor O.F.) <br />AREA GROSS SF 0, F. OCCUPANTS <br />PRODUCE, DELI, MEAT <br />SEAFOOD, OFFICES <br />TRAINING, RESTROOMS: 5,633 100 57 <br />STORAGE AREA <br />Minimum Occupant Load Per Table 1003.1 - SBC <br />Storage Area: 300 Gross SF Per Occupant (Occupant Factor O.FJ <br />AREA GROSS SF 0. F. OCCUPANTS <br />STORAGE, STOCK, SHIPPING AND 8,792 300 30 <br />MEZZANINE AREAS: <br />(Not open to public mercantile areas) <br />MEANS OF EGRESS CAPACITY CALCULATIONS <br />GENERAL REQUIREMENTS: <br />MAXIMUM <br />TRAVEL DISTANCE (FULLY SPRINKLERED): <br />250 <br />FT (SBC) <br />200 <br />FT (NFPA) <br />MAXIMUM <br />DEAD END CORRIDOR LENGTH: <br />20 <br />FT <br />EGRESS <br />WIDTH PER PERSON SERVED (LEVEL) <br />.2 <br />INCHES PER OCCUPANT <br />MINIMUM <br />CORRIDOR/AISLE WIDTH: <br />44 <br />INCHES <br />MINIMUM <br />CLEAR OPENING OF EXIT DOORS: <br />32 <br />INCHES <br />TOTAL OCCUPANT LOAD: <br />PUBLIX BUILDING: <br />SALES AREA: 964 OCCUPANTS <br />BUSINESS AREA: 57 OCCUPANTS <br />STORAGE AREA: 30 OCCUPANTS <br />TOTAL OCCUPANT LOAD: 1051 OCCUPANTS <br />MINIMUM MEANS OF EGRESS CAPACITY REQUIRED: <br />(TOTAL OCCUPANT LOAD X EGRESS WIDTH PER PERSON SERVED) <br />1ID51 OCCUPANTS X 0.2 IN/PERSON = 211 IN <br />TOTAL MEANS OF EGRESS CAPACITY PROVIDED: <br />ENTRANCE VESTIBULE DOORS: <br />#101A <br />= 105 <br />INCHES <br />#101B <br />= 105 <br />INCHES <br />EXISTING <br />EAST DOOR: <br />#110C <br />= 32 <br />INCHES <br />EXISTING <br />NORTH DOOR: <br />#114A <br />= 32 <br />INCHES <br />EXISTING <br />NORTH DOOR: <br />#130A <br />= 32 <br />INCHES <br />EXISTING <br />WEST DOOR: <br /># 132 <br />= 32 <br />INCHES <br />TOTAL <br />= 338 <br />INCHES <br />EXIT REQUIREMENTS: <br />MINIMUM NUMBER OF ACCESSIBLE EXITS REQUIRED: 4 (1000 - 1499 OCCUPANTS) <br />TOTAL NUMBER OF ACCESSIBLE EXITS PROVIDED: 4 <br />TOTAL NUMBER OF EXITS PROVIDED: 6 <br />SVERDR UP FACILITIES, INC. <br />Florida Corporate License #AA C001291 <br />5750 Major Boulevard, Suite 500, Orlando, Florida 32819-7946 <br />(407) 903-5001 Fax (407) 903-5150 <br />ARCHITECT OF RECORD <br />NAME: FLOYD WILSON McCOLLUM, JR., AIA <br />REGISTRATION., FLORIDA REG #AR0016162 <br />Revision: <br />Date: By: Description: <br />• <br />V <br />X <br />C <br />�D <br />a <br />r <br />�r <br />N <br />o <br />= <br />�0 L <br />co <br />0 <br />ZCn <br />M <br />w <br />C 0 <br />� <br />w <br />TC1 <br />-r-- <br />woo <br />w <br />�-� <br /><C — <br />•� <br />r <br />� Lu <br />J <br />U— — <br />Owwrn <br />d�ri <br />�w�O <br />g <br />w <br />_� <br />M 3: <br />> t� <br />O <br />w <br />Ex <br />U <br />= <br />n- <br />LU <br />1 _ <br />O� NC <br />U LL <br />M <br />I_ <br />Cn fir— " <br />Key Plan: PLAN NORTH <br />N <br />TRUE NORTH <br />Scales: <br />0 8' 16' 32' 48' <br />�i6 = 1`0" <br />Sverdrup Project No.: 22196390 <br />Drawing Title: <br />CODE ANALYSIS, <br />ABBREVIATIONS AND <br />GENERAL SYMBOLS <br />Date: 03/19/99 <br />Designed By: JTR Drawing No.: <br />Drawn By: J T R <br />Checked By: FWM A001 <br />22-MAR-1999 17.04 hewittme po\22196390\700cddd\701dreh\390a001w.dgn <br />
The URL can be used to link to this page
Your browser does not support the video tag.