th• Iw <br />Wall Types <br />1 a = EXISTING EXTERIOR WALL, PATCH & REPAIR AS <br />REQ'D. G.C. TO FURR OUT PER 1-5/8P FURRING <br />DETAIL TO UNDERSIDE OF DECK ABOVE. VERIFY <br />(E) CONDITIONS IN FIELD. SEE WALL TYPE <br />DETAILS ON SHEET A1.3 <br />1 b = EXISTING EXTERIOR WALL, PATCH & REPAIR AS <br />REQ'D., G.C. TO FURR OUT W/ 1-5/8' METAL <br />FURRING AND 5/8" GYP. BD., WHERE SHOWN ON <br />PLAN, UP TO 6"-9" ABOVE ADJACENT FINISH <br />CEILING., VERIFY (E) CONDITIONS IN FIELD. <br />O = COORDINATE HEIGHT WITH REFLECTED CEILING <br />PLAN A2.0 (BUILD TO 6"-9" ABOVE HIGHEST <br />ADJACENT FINISH CEILING), SEE WALL TYPE <br />DETAILS ON SHEET A1.3 <br />O = TYPICAL WALL, FULL HEIGHT TO UNDERSIDE <br />OF DECK ABOVE, BRACE AS REQ'D, SEE WALL <br />TYPE DETAILS ON SHEET A1.3 <br />4a = PARTIAL HEIGHT WALL, SEE WALL TYPE <br />DETAILS ON SHEET A1.3 <br />4b = PARTIAL HEIGHT WALL WITH SUSPENDED WALL, <br />SEE WALL TYPE DETAILS ON SHEET A1.3 <br />5a =PLUMBING WALL 0 LAVATORIES, 10'-O"± <br />(6"-9" ABOVE ADJACENT FINISH CEILING) SEE <br />WALL TYPE DETAILS ON SHEET A1.3 <br />5b = PLUMBING WALL BTWN. MEN'S & WOMEN'S <br />BATHROOM, TWO ROWS METAL STUDS (FOR 24" <br />CAVITY), SECURE TO DEMISING WALL, SEE WALL <br />TYPE DETAILS ON SHEET A1.3 <br />5c = PLUMBING WALL BTWN. MEN'S & WOMEN'S <br />SHOWER AREA, TWO ROWS METAL STUDS (FOR <br />24" CAVITY), SECURE TO DEMISING WALL, SEE <br />WALL TYPE DETAILS ON SHEET A1.3 <br />5d =PLUMBING WALL 0 SHOWER WING WALLS, <br />10'-0"t (6P-9" ABOVE ADJACENT FINISH <br />CEILING) SEE WALL TYPE DETAILS ON SHEET <br />A1.3 <br />NOTE: <br />G.C. TO PROVIDE LEVEL 4 GYPSUM <br />BOARD FINISH PER GA 214 <br />Floor Plan Reference Notes <br />O1 (E) EXTERIOR WALL <br />NOTE: <br />O (E) SEPARATE BUILDING EXTERIOR WALLS & PARAPETS, G.C. TO FINISH PLANET FITNESS SIDE PER ELEVATIONS G.C. IS RESPONSIBLE FOR REPLACING <br />ANY DAMAGED FLASHING AROUND <br />O3 NEW STOREFRONT GLAZING, G.C. TO PROTECT DURING CONSTRUCTION EXTERIOR DOORS <br />O4 STOREFRONT GLAZING WITHIN 18" OF FINISH FLOOR OR WITHIN 24" OF DOOR SWING TO BE TEMPERED; G.C. TO VERIFY AND REPLACE AS REQUIRED <br />O5 EXISTING STRUCTURAL COLUMN TO REMAIN, TYP OF ALL, G.C. TO PROTECT DURING CONST AND PREP FOR NEW PAINT FINISH P-1 NOTE: <br />ALL EXPOSED ELECTRICAL CONDUIT, <br />O6 G.C. TO ROUTE POWER TO RACEWAYS FOR TREADMILLS, TYP. CUT CONCRETE TRENCH AND RE -POUR FOR SMOOTH FLUSH FINISH, SEE ELECTRICAL PIPES AND INFRASTRUCTURE TO BE <br />PAINTED TO MATCH WALL PAINT COLOR <br />O7 ELECTRICAL RACEWAY BY STARLINE, PROVIDED BY TENANT, SEE ELECTRICAL AS OCCURS, TYP. <br />O8 G.C. TO FRAME 6" DEEP x 18" WIDE DECORATIVE PILASTER, FINISH PER ELEVATIONS <br />Og NOT USED E <br />0HEADER ABOVE, SEE INTERIOR ELEVATIONS <br />0 <br />11 GYP. BD. EYEBROW SOFFIT ABOVE, SEE REFLECTED CEILING PLAN AND INTERIOR ELEVATIONS <br />12 GYP. BD. GEAR SOFFIT ABOVE, SEE REFLECTED CEILING PLAN AND INTERIOR ELEVATIONS <br />13 NOT USED <br />14 PARTIAL HEIGHT WALL TO BE WRAPPED WITH METAL WAINSCOT AND CAPPED; SEE WALL TYPE DETAILS ON A1.3 <br />15 WALL(S) TO HAVE WAINSCOT AS SCHEDULED, SEE INTERIOR ELEVATIONS N <br />16 WALL -MOUNTED PF PLUNK ALARM" W/ WALL GRAPHIC BY TENANT, G.C. TO PROVIDE POWER, SEE INT. ELEV. FOR MOUNTING HEIGHT _ <br />17 NOT USED <br />18 30 MINUTE CLOCK, VERIFY EXACT LOCATION W/ TENANT, G.C. TO PROVIDE POWER <br />19 MISSION STATEMENT WALL GRAPHIC BY TENANT, SEE INTERIOR ELEVATIONS, VERIFY FINAL LOCATION WITH TENANT <br />20 TELEVISIONS MOUNTED FROM TRUSSES ABOVE ® 10' TO 11' A.F.F., TYP. <br />21 CONTINUOUS WALL MOUNTED MIRRORS 0 24" A.F.F., SEE INTERIOR ELEVATIONS <br />22 BEVERAGE COOLERS, VERIFY ROUGH OPENING HEIGHT AND WIDTH W/MANUF. PRIOR TO FRAMING OPENING D <br />23 TRANSFORMER, SEE ELECTRICAL <br />24 ELECTRICAL PANEL, SEE ELECTRICAL C14 <br />I <br />25 RATED 2A-10B:C FIRE EXTINGUISHER PROVIDED AND INSTALLED BY G.C., FOR EACH 3,000 SQUARE FEET OF SPACE AND TRAVEL DISTANCE NOT N <br />EXCEEDING 75'-0", MOUNT TO WALL W/ TOP NO GREATER THAN 5'-0" A.F.F., CLEARLY TAGGED/DATED, SEE 2014 FFPC TABLE 13.6.8.2.1.1 <br />26 EMERGENCY LIGHTING INVERTER, SEE 'EMU' NOTATION ON PLANS & AND LIGHTING SCHEDULE ON SHEET A2.0 <br />27 NEW FIRE ALARM CONTROL PANEL, PROVIDED BY TENANT, G.C. TO COORD. INSTALLATION WITH FIRE ALARM SUB -CONTRACTOR <br />28 GYP BD. COVERED WALL TO CONTINUE TO DECK ABOVE, FINISH PER ELEVATIONS <br />29 ALIGN NEW WALL WITH EXISTING WALL <br />NOTE: <br />G.C. TO VERIFY LOCATION(S) OF ALL <br />EXISTING STRUCTURAL COLUMNS PRIOR <br />TO CONSTRUCTION AND NOTIFY <br />ARCHITECT OF PLAN DISCREPANCIES <br />NOTE: <br />ALL CONSTRUCTION TO BE FIRE <br />RESISTANT OR OF FIRE RETARDANT <br />MATERIALS. ALL INTERIOR FINISHES TO <br />COMPLY WITH FLAME SPREAD <br />REQUIREMENTS OF FBC. - <br />C L`•— — <br />0 <br />A — <br />NOTE: <br />G.C. TO CONFIRM RACEWAYS WITH <br />EQUIPMENT MANUFACTURER PRIOR TO <br />MANUFACTURING <br />NOTE: <br />SEE SHEETS A3.0 & A3.1 FOR DOOR, <br />WINDOW, AND HARDWARE SCHEDULE <br />nil <br />FLOOR PLAN <br />1 <br />39'-9 1/2" <br />CIRCUIT TRAINING <br />102 <br />1,2 <br />22'-7 1/2" <br />LECTRICAL PF 361 <br />112E 7103B <br />�' j UI III I <br />nc U U <br />123'-4"t <br />V.I.F. <br />60'-11 1/2" <br />ABS & STRETCHING <br />1 33A <br />TYP. <br />4,5 <br />A4.2 <br />11 <br />NOTE: <br />G.C. TO PROVIDE PANIC HARDWARE <br />— ALL EXISTING EXIT DOORS PER FBC. <br />O <br />J <br />NOTE: <br />G.C. TO VERIFY EXACT WALL COVERING <br />SQUARE FOOTAGES NEEDED IN FIELD. <br />WASTE % TO BE DETERMINED BY G.C. <br />AND WALL COVERING/PAINT VENDOR <br />A4.2 <br />3 <br />A4.2 <br />E EGRESS CORRIDOR <br />119 <br />---------- <br />00 <br />4b TV. TYP ' TYP' <br />18 12 10 14 11 4b 14 10 4b 14 10 12 � III P. <br />--- — — — 25 3 <br />I 1 MEN'S LOCKER <br />-------------- - ------------- <br />15'-0 1 /2" 10'-0" 15'-2 1 /2" 6'-1 P 10'-0" 6'-8 1 /2" 5'-5" 10'-0" 5' I 109 <br />CLEAR CLEAR I — — — — — _ =CLEAR= _ — = rr <br />I 2 91 <br />DIP.II 3 6 I I 2 r 1 11 ( Q. 1 <br />91 <br />21 \ TYP.20 A4.1 I I I I I / II 1 <br />20 I =__ -- 5a-- -- 1 <br />IJ <br />I I I II <br />7 MEN'S SHOWER! � I <br />i <br />II 107 I t 2 1 <br />I 3'i 3 <br />.I 1 2 1 <br />JANITOR <br />110B I 5b s 5c 5d 5d n 5b <br />II �1 i <br />i " <br />JANITOR 1 <br />I I � 5d 5d <br />11OA <br />II 19 <br />2 <br />III �l b <br />II 5 — _ <br />—_ WOMEN'S SHOWER 11 2--- - - - - -- <br />z 106 <br />A1.1 ___--------- <br />45 <br />1\\� ' II �/I � II 5a 1 � 2 i <br />() III 2 II i <br />A4.1 ( I I A4.1 <br />2 <br />STORAGE i 25 3 <br />113A <br />II <br />11 ii II I �J3, <br />11 I I PEOPF III 1 b <br />I <br />—II 5 I I I7­11/ 1 <br />I � <br />7 I 2 <br />I II I <br />II I I I I I I <br />BLACK CARD LOBBY <br />10-10" 114 2 I I -------I <br />----- ����- 28 111E <br />l I• I I I <br />Nil I <br />' <br />' © i <br />i <br />i <br />MEN'S BATH <br />108 <br />WOMEN'S BATH <br />105 <br />WOMEN'S LOCKER <br />104 <br />TANNING <br />111B <br />TANNING <br />111A <br />TANNING <br />111C <br />TANNING <br />111D <br />MASSAGE <br />A <br />WORKOUT SPACE' i 1 A RECEPTION I V IT HYDROMASSAGE ALL DIMENSIONS ARE TO FACE OF FINISH <br />101 #116 112A 1158 (F.O.F.) UNLESS OTHERWISE NOTED. <br />i I A4.o I I <br />49'-6" 34'-1 1/2" 39'-8 1/2" <br />123'-4't <br />2 ) ( 3 ) ( 4 <br />Planet Fitness <br />4 Liberty Lane West <br />Hampton, New Hampshire 03842 <br />Issue Sets <br />No. Issue Set I By I Date fAppr. <br />ARCHITECT <br />J <br />Daniel K. Mullin, Architect, NCARB <br />517 S Main St. <br />Moscow, ID 83843 <br />P.(208) 892-8433 <br />F. (208) 892-8533 <br />MEP ENGINEERS <br />Dave M. Saarem, P.E. <br />CIO <br />2188 Alfred Way <br />Carson City, NV 89703 <br />P.(775)772-9846 <br />STRUCTURAL ENGINEERS <br />Richard M. Welcher, P.E. <br />Tatum Smith Welcher Engineers, Inc. <br />3100 S Market St, Suite 202 <br />Rogers, AR 72758 <br />P. (479) 621-6128 <br />COPYRIGHT <br />These plans are an instrument of service and are <br />the property of DKMullin Architects, and may not be <br />duplicated, disclosed, or reproduced without the <br />written consent of DKMullin Architects. Copyright <br />and infringement will be enforced and prosecuted. <br />Project Manager Approval <br />Architect/Engineer of Record <br />V <br />ZO <br />xt. <br />Location <br />7910 GALL BLVD <br />ZEPHYRHILLS, FL 33541 <br />Project/Space No. <br />Planet Fitness Tenant Improvement <br />Sheet Title <br />FLOOR PLAN <br />NORTH <br />1 /8" = 1'-0" <br />Scale: As Shown <br />Drawn By: C.W. <br />Chk'd By: T.G. <br />Issue Date: <br />APRIL 15, 2020 <br />Project No. <br />191205 <br />Sheet <br />Al *0 <br />