th• Iw
<br />Wall Types
<br />1 a = EXISTING EXTERIOR WALL, PATCH & REPAIR AS
<br />REQ'D. G.C. TO FURR OUT PER 1-5/8P FURRING
<br />DETAIL TO UNDERSIDE OF DECK ABOVE. VERIFY
<br />(E) CONDITIONS IN FIELD. SEE WALL TYPE
<br />DETAILS ON SHEET A1.3
<br />1 b = EXISTING EXTERIOR WALL, PATCH & REPAIR AS
<br />REQ'D., G.C. TO FURR OUT W/ 1-5/8' METAL
<br />FURRING AND 5/8" GYP. BD., WHERE SHOWN ON
<br />PLAN, UP TO 6"-9" ABOVE ADJACENT FINISH
<br />CEILING., VERIFY (E) CONDITIONS IN FIELD.
<br />O = COORDINATE HEIGHT WITH REFLECTED CEILING
<br />PLAN A2.0 (BUILD TO 6"-9" ABOVE HIGHEST
<br />ADJACENT FINISH CEILING), SEE WALL TYPE
<br />DETAILS ON SHEET A1.3
<br />O = TYPICAL WALL, FULL HEIGHT TO UNDERSIDE
<br />OF DECK ABOVE, BRACE AS REQ'D, SEE WALL
<br />TYPE DETAILS ON SHEET A1.3
<br />4a = PARTIAL HEIGHT WALL, SEE WALL TYPE
<br />DETAILS ON SHEET A1.3
<br />4b = PARTIAL HEIGHT WALL WITH SUSPENDED WALL,
<br />SEE WALL TYPE DETAILS ON SHEET A1.3
<br />5a =PLUMBING WALL 0 LAVATORIES, 10'-O"±
<br />(6"-9" ABOVE ADJACENT FINISH CEILING) SEE
<br />WALL TYPE DETAILS ON SHEET A1.3
<br />5b = PLUMBING WALL BTWN. MEN'S & WOMEN'S
<br />BATHROOM, TWO ROWS METAL STUDS (FOR 24"
<br />CAVITY), SECURE TO DEMISING WALL, SEE WALL
<br />TYPE DETAILS ON SHEET A1.3
<br />5c = PLUMBING WALL BTWN. MEN'S & WOMEN'S
<br />SHOWER AREA, TWO ROWS METAL STUDS (FOR
<br />24" CAVITY), SECURE TO DEMISING WALL, SEE
<br />WALL TYPE DETAILS ON SHEET A1.3
<br />5d =PLUMBING WALL 0 SHOWER WING WALLS,
<br />10'-0"t (6P-9" ABOVE ADJACENT FINISH
<br />CEILING) SEE WALL TYPE DETAILS ON SHEET
<br />A1.3
<br />NOTE:
<br />G.C. TO PROVIDE LEVEL 4 GYPSUM
<br />BOARD FINISH PER GA 214
<br />Floor Plan Reference Notes
<br />O1 (E) EXTERIOR WALL
<br />NOTE:
<br />O (E) SEPARATE BUILDING EXTERIOR WALLS & PARAPETS, G.C. TO FINISH PLANET FITNESS SIDE PER ELEVATIONS G.C. IS RESPONSIBLE FOR REPLACING
<br />ANY DAMAGED FLASHING AROUND
<br />O3 NEW STOREFRONT GLAZING, G.C. TO PROTECT DURING CONSTRUCTION EXTERIOR DOORS
<br />O4 STOREFRONT GLAZING WITHIN 18" OF FINISH FLOOR OR WITHIN 24" OF DOOR SWING TO BE TEMPERED; G.C. TO VERIFY AND REPLACE AS REQUIRED
<br />O5 EXISTING STRUCTURAL COLUMN TO REMAIN, TYP OF ALL, G.C. TO PROTECT DURING CONST AND PREP FOR NEW PAINT FINISH P-1 NOTE:
<br />ALL EXPOSED ELECTRICAL CONDUIT,
<br />O6 G.C. TO ROUTE POWER TO RACEWAYS FOR TREADMILLS, TYP. CUT CONCRETE TRENCH AND RE -POUR FOR SMOOTH FLUSH FINISH, SEE ELECTRICAL PIPES AND INFRASTRUCTURE TO BE
<br />PAINTED TO MATCH WALL PAINT COLOR
<br />O7 ELECTRICAL RACEWAY BY STARLINE, PROVIDED BY TENANT, SEE ELECTRICAL AS OCCURS, TYP.
<br />O8 G.C. TO FRAME 6" DEEP x 18" WIDE DECORATIVE PILASTER, FINISH PER ELEVATIONS
<br />Og NOT USED E
<br />0HEADER ABOVE, SEE INTERIOR ELEVATIONS
<br />0
<br />11 GYP. BD. EYEBROW SOFFIT ABOVE, SEE REFLECTED CEILING PLAN AND INTERIOR ELEVATIONS
<br />12 GYP. BD. GEAR SOFFIT ABOVE, SEE REFLECTED CEILING PLAN AND INTERIOR ELEVATIONS
<br />13 NOT USED
<br />14 PARTIAL HEIGHT WALL TO BE WRAPPED WITH METAL WAINSCOT AND CAPPED; SEE WALL TYPE DETAILS ON A1.3
<br />15 WALL(S) TO HAVE WAINSCOT AS SCHEDULED, SEE INTERIOR ELEVATIONS N
<br />16 WALL -MOUNTED PF PLUNK ALARM" W/ WALL GRAPHIC BY TENANT, G.C. TO PROVIDE POWER, SEE INT. ELEV. FOR MOUNTING HEIGHT _
<br />17 NOT USED
<br />18 30 MINUTE CLOCK, VERIFY EXACT LOCATION W/ TENANT, G.C. TO PROVIDE POWER
<br />19 MISSION STATEMENT WALL GRAPHIC BY TENANT, SEE INTERIOR ELEVATIONS, VERIFY FINAL LOCATION WITH TENANT
<br />20 TELEVISIONS MOUNTED FROM TRUSSES ABOVE ® 10' TO 11' A.F.F., TYP.
<br />21 CONTINUOUS WALL MOUNTED MIRRORS 0 24" A.F.F., SEE INTERIOR ELEVATIONS
<br />22 BEVERAGE COOLERS, VERIFY ROUGH OPENING HEIGHT AND WIDTH W/MANUF. PRIOR TO FRAMING OPENING D
<br />23 TRANSFORMER, SEE ELECTRICAL
<br />24 ELECTRICAL PANEL, SEE ELECTRICAL C14
<br />I
<br />25 RATED 2A-10B:C FIRE EXTINGUISHER PROVIDED AND INSTALLED BY G.C., FOR EACH 3,000 SQUARE FEET OF SPACE AND TRAVEL DISTANCE NOT N
<br />EXCEEDING 75'-0", MOUNT TO WALL W/ TOP NO GREATER THAN 5'-0" A.F.F., CLEARLY TAGGED/DATED, SEE 2014 FFPC TABLE 13.6.8.2.1.1
<br />26 EMERGENCY LIGHTING INVERTER, SEE 'EMU' NOTATION ON PLANS & AND LIGHTING SCHEDULE ON SHEET A2.0
<br />27 NEW FIRE ALARM CONTROL PANEL, PROVIDED BY TENANT, G.C. TO COORD. INSTALLATION WITH FIRE ALARM SUB -CONTRACTOR
<br />28 GYP BD. COVERED WALL TO CONTINUE TO DECK ABOVE, FINISH PER ELEVATIONS
<br />29 ALIGN NEW WALL WITH EXISTING WALL
<br />NOTE:
<br />G.C. TO VERIFY LOCATION(S) OF ALL
<br />EXISTING STRUCTURAL COLUMNS PRIOR
<br />TO CONSTRUCTION AND NOTIFY
<br />ARCHITECT OF PLAN DISCREPANCIES
<br />NOTE:
<br />ALL CONSTRUCTION TO BE FIRE
<br />RESISTANT OR OF FIRE RETARDANT
<br />MATERIALS. ALL INTERIOR FINISHES TO
<br />COMPLY WITH FLAME SPREAD
<br />REQUIREMENTS OF FBC. -
<br />C L`•— —
<br />0
<br />A —
<br />NOTE:
<br />G.C. TO CONFIRM RACEWAYS WITH
<br />EQUIPMENT MANUFACTURER PRIOR TO
<br />MANUFACTURING
<br />NOTE:
<br />SEE SHEETS A3.0 & A3.1 FOR DOOR,
<br />WINDOW, AND HARDWARE SCHEDULE
<br />nil
<br />FLOOR PLAN
<br />1
<br />39'-9 1/2"
<br />CIRCUIT TRAINING
<br />102
<br />1,2
<br />22'-7 1/2"
<br />LECTRICAL PF 361
<br />112E 7103B
<br />�' j UI III I
<br />nc U U
<br />123'-4"t
<br />V.I.F.
<br />60'-11 1/2"
<br />ABS & STRETCHING
<br />1 33A
<br />TYP.
<br />4,5
<br />A4.2
<br />11
<br />NOTE:
<br />G.C. TO PROVIDE PANIC HARDWARE
<br />— ALL EXISTING EXIT DOORS PER FBC.
<br />O
<br />J
<br />NOTE:
<br />G.C. TO VERIFY EXACT WALL COVERING
<br />SQUARE FOOTAGES NEEDED IN FIELD.
<br />WASTE % TO BE DETERMINED BY G.C.
<br />AND WALL COVERING/PAINT VENDOR
<br />A4.2
<br />3
<br />A4.2
<br />E EGRESS CORRIDOR
<br />119
<br />----------
<br />00
<br />4b TV. TYP ' TYP'
<br />18 12 10 14 11 4b 14 10 4b 14 10 12 � III P.
<br />--- — — — 25 3
<br />I 1 MEN'S LOCKER
<br />-------------- - -------------
<br />15'-0 1 /2" 10'-0" 15'-2 1 /2" 6'-1 P 10'-0" 6'-8 1 /2" 5'-5" 10'-0" 5' I 109
<br />CLEAR CLEAR I — — — — — _ =CLEAR= _ — = rr
<br />I 2 91
<br />DIP.II 3 6 I I 2 r 1 11 ( Q. 1
<br />91
<br />21 \ TYP.20 A4.1 I I I I I / II 1
<br />20 I =__ -- 5a-- -- 1
<br />IJ
<br />I I I II
<br />7 MEN'S SHOWER! � I
<br />i
<br />II 107 I t 2 1
<br />I 3'i 3
<br />.I 1 2 1
<br />JANITOR
<br />110B I 5b s 5c 5d 5d n 5b
<br />II �1 i
<br />i "
<br />JANITOR 1
<br />I I � 5d 5d
<br />11OA
<br />II 19
<br />2
<br />III �l b
<br />II 5 — _
<br />—_ WOMEN'S SHOWER 11 2--- - - - - --
<br />z 106
<br />A1.1 ___---------
<br />45
<br />1\\� ' II �/I � II 5a 1 � 2 i
<br />() III 2 II i
<br />A4.1 ( I I A4.1
<br />2
<br />STORAGE i 25 3
<br />113A
<br />II
<br />11 ii II I �J3,
<br />11 I I PEOPF III 1 b
<br />I
<br />—II 5 I I I711/ 1
<br />I �
<br />7 I 2
<br />I II I
<br />II I I I I I I
<br />BLACK CARD LOBBY
<br />10-10" 114 2 I I -------I
<br />----- ����- 28 111E
<br />l I• I I I
<br />Nil I
<br />'
<br />' © i
<br />i
<br />i
<br />MEN'S BATH
<br />108
<br />WOMEN'S BATH
<br />105
<br />WOMEN'S LOCKER
<br />104
<br />TANNING
<br />111B
<br />TANNING
<br />111A
<br />TANNING
<br />111C
<br />TANNING
<br />111D
<br />MASSAGE
<br />A
<br />WORKOUT SPACE' i 1 A RECEPTION I V IT HYDROMASSAGE ALL DIMENSIONS ARE TO FACE OF FINISH
<br />101 #116 112A 1158 (F.O.F.) UNLESS OTHERWISE NOTED.
<br />i I A4.o I I
<br />49'-6" 34'-1 1/2" 39'-8 1/2"
<br />123'-4't
<br />2 ) ( 3 ) ( 4
<br />Planet Fitness
<br />4 Liberty Lane West
<br />Hampton, New Hampshire 03842
<br />Issue Sets
<br />No. Issue Set I By I Date fAppr.
<br />ARCHITECT
<br />J
<br />Daniel K. Mullin, Architect, NCARB
<br />517 S Main St.
<br />Moscow, ID 83843
<br />P.(208) 892-8433
<br />F. (208) 892-8533
<br />MEP ENGINEERS
<br />Dave M. Saarem, P.E.
<br />CIO
<br />2188 Alfred Way
<br />Carson City, NV 89703
<br />P.(775)772-9846
<br />STRUCTURAL ENGINEERS
<br />Richard M. Welcher, P.E.
<br />Tatum Smith Welcher Engineers, Inc.
<br />3100 S Market St, Suite 202
<br />Rogers, AR 72758
<br />P. (479) 621-6128
<br />COPYRIGHT
<br />These plans are an instrument of service and are
<br />the property of DKMullin Architects, and may not be
<br />duplicated, disclosed, or reproduced without the
<br />written consent of DKMullin Architects. Copyright
<br />and infringement will be enforced and prosecuted.
<br />Project Manager Approval
<br />Architect/Engineer of Record
<br />V
<br />ZO
<br />xt.
<br />Location
<br />7910 GALL BLVD
<br />ZEPHYRHILLS, FL 33541
<br />Project/Space No.
<br />Planet Fitness Tenant Improvement
<br />Sheet Title
<br />FLOOR PLAN
<br />NORTH
<br />1 /8" = 1'-0"
<br />Scale: As Shown
<br />Drawn By: C.W.
<br />Chk'd By: T.G.
<br />Issue Date:
<br />APRIL 15, 2020
<br />Project No.
<br />191205
<br />Sheet
<br />Al *0