My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7952-7954 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7952-7954 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 10:46:35 PM
Creation date
2/19/2025 2:18:08 PM
Metadata
Fields
Template:
Building Plans
Street #
7952-7954
Location
Gall Blvd
Contractor
FM Liner Construction
Building Plans - Permit #
11347
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' - ', � `` • � . . ) • s a • t • • ^ • T • � • i a s t • • 1 F • t t • 1 i e <br />l p•He <br />1EXISTING REAR SIDEWALK IS FLUSH <br />=-�WITH ADJACENT PAVEMENT ALONG <br />THE ENTIRE REAR OF BUILDING B <br />1 <br />I <br />, <br />---- --- -- - -i- IRE. CIVIL PLANS <br />�' <br />i IRE HYDRANT <br />I - <br />i <br />��� �•'I i 1�1 I! - - --- <br />---- <br />Bldg EXISTING <br />- - ---- FIRE RISER ROOM - <br />r <br />l I ? 011� <br />FUTURE BUILDING TO BE.DESIGNED, PERMITTED, <br />^AND CONSTRUCTED AS <br />AOF DRAWNGS - <br />I <br />1 I � <br />"------------ <br />- --- <br />----------------- <br />•I I ' � I I I � II j I 1 <br />FIRE HYDRANT j <br />I I j - RE: CIVIL PLANS — — — — <br />r <br />45'4" <br />FROM INSIDE FACE <br />---- OF CMU TO CENTER I Bldg C l <br />OF DEMISING WALL Bldg g j <br />VERIFY IN FIELD <br />EXISTING BUILDING <br />j -�•- TO REMAIN AS IS. � <br />' B1 B2 <br />-- ,L=F-- <br />... r•-- L - + - -- <br />EXISTING 4 REFER TO SHEET A101 FOR EXISTING <br />s "" HANDICAP RAMP ENLARGED PLANS � LIFE = t <br />I —f HANDICAP RAMP r <br />SAFETY INFORMATION <br />I l <br />I 4 <br />. i . i ..•ice\`\ .. ! _ .. _ __ _ _ _ <br />�17 <br />� , ! <br />i <br />I I' I, {', i L-1 J —� !.- _ __ __ _ . ------ -- - -.L. • 11 <br />1 <br />f• <br />' <br />_ <br />1• I <br />Parcel 1 <br />THIS PARCEL TO BE L_ -- - - - -- - - - -- - - - II <br />i I ! <br />DESIGNED, PERMITTED, <br />AND CONSTRUCTED AS _ l <br />! I , A SEPARATE SET -- -- <br />1 ) I • i I OF DRAWINGS s `�; . + <br />IF I I <br />--- <br />I <br />t <br />t <br />i <br />i <br />FIRE HYDRANT '- <br />R . CIVIL PLANS �; _ ---- -- ---- -- - --- --= _ , <br />j ..+. <br />I. I I •ww <br />i +.ter <br />I 1, <br />FIRE HYDRANT <br />j I I RE: CIVIL PLANS 1 ., <br />1 1 <br />I I <br />I <br />Parcel 2 Parcel 3 <br />THIS PARCEL TO BE THIS PARCEL TO BE t I! <br />DESIGNED, PERMITTED, <br />DESIGNED, PERMITTED, <br />AND CONSTRUCTED AS ' I <br />I AND CONSTRUCTED AS <br />1 I f A SEPARATE SET A SEPARATE SET E <br />ht <br />I 1 OF DRAWINGS <br />1# i I OF DRAWINGS <br />I ! <br />i - <br />� <br />! I 11rp I i y j al <br />. 1 <br />0 <br />e <br />a <br />rm <br />Overall Project Site Plan <br />N SCALE: 1" = 4V-0" <br />THIS SET OF DRAWINGS IS LIMITED TO TENANT B1 B2 ONLY. REFER TO THE COVER SHEET FOR A COMPLETE <br />DESCRIPTION OF THE SCOPE OF WORK COVERED IN THIS SET OF DRAWINGS. <br />BUILDINGS C, D, E, 81 F ARE EXISTING AND ARE TO REMAIN AS IS. <br />ALL OTHER FUTURE BUILDINGS AND PARCELS SHALL BE DESIGNED, PERMITTED, AND CONSTRUCTED SEPARATELY. <br />FOR COMPLETE SITE WORK INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE LANDSCAPE AND IRRIGATION INFORMATION, REFER TO THE CIVIL DRAWINGS PREPARED BY AVID. <br />FOR COMPLETE SITE LIGHTING INFORMATION, REFER TO THE BUILDING B SHELL ELECTRICAL DRAWINGS. <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />FIRE HYDRANT <br />RE: CIVIL PLANS <br />0--,r,T;T Lj <br />H <br />rIRC r1 T UR/'YY 1 <br />RE: CIVIL PLANS I <br />Bldg D <br />Bldg E <br />Bldg F <br />EXISTING BUILDING <br />EXISTING BUILDING <br />EXISTING BUILDING <br />' <br />TO REMAIN AS IS. <br />TO REMAIN AS IS. <br />TO REMAIN AS IS. <br />•-'1�'^ ...._--III. �1r'• --�► <br />0 <br />Yr <br />t <br />0 <br />Elevation & Grading Notes <br />1. ABBREVIATIONS: <br />TOS - TOP OF FLOOR SLAB INSIDE BUILDING <br />TOC - TOP OF CURB AT EDGE OF SIDEWALK <br />TOP - TOP OF PAVING <br />2. EXISTING TOS=113.00'. <br />3. ALL SIDEWALKS ARE EXISTING AND START 114" BELOW THE <br />TOS AT ALL DOORS. <br />4. ALL EXTERIOR DOORS ARE EXISTING AND HAVE EXISTING <br />THRESHOLDS THAT DO NOT EXCEED 112" IN HEIGHT. <br />5. ALL SIDEWALKS ARE EXISTING AND SLOPE AWAY FROM THE <br />BUILDING AT A RATE BETWEEN 1% MIN AND 2% MAX. <br />6. AT ALL FRONT SIDEWALKS, TOC IS 6" MAX ABOVE ADJACENT TOP. <br />7. AT ALL REAR SIDEWALKS, TOC IS FLUSH WITH ADJACENT TOP. <br />8. ALL HANDICAP RAMPS ARE EXISTING AND HAVE A SLOPE OF 1:14 <br />MAX. THE SURFACES OF ALL CURB RAMPS HAVE RAISED <br />DETECTABLE WARNING FINISHES. <br />9. THE BOTTOMS OF ALL HANDICAP RAMPS ARE FLUSH WITH <br />THE ADJACENT TOP <br />10. REFER TO CIVIL DRAWINGS FOR EXACT ELEVATIONS. <br />11. THE CONTRACTOR SHALL FIELD VERIFY ALL SIDEWALK AND <br />GRADING CONDITIONS PRIOR TO STARTING WORK THE GC <br />SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY OF THE <br />EXISTING CONDITIONS DO NOT MEET ADA REQUIREMENTS. <br />Fire Marshal's Checklist <br />EGRESS TRAVEL AND EXITS <br />RE: LIFESAFETY PLAN & CODE INFO ON A101 <br />EXIT AND EMERGENCY LIGHTS <br />RE: LIFESAFETY PLAN ON A101 <br />SMOKE DETECTORS <br />A FIRE ALARM SYSTEM WILL BE DESIGNED AND PERMITTED BY <br />CONTRACTOR'S SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FIRE EXTINGUISHERS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS <br />FIRE RATED WALLS <br />RE: LIFESAFETY PLAN ON A101 FOR LOCATIONS & UL DETAILS <br />ALL DOORS SHALL HAVE HARDWARE THAT COMPLIES WITH <br />PANIC HARDWARE <br />REQUIREMENTS FOR EGRESS AND ADA ACCESSIBILITY. <br />RE: LIFESAFETY PLAN ON A101 FOR DOOR LOCATIONS <br />DUCT DETECTORS SHALL BE PROVIDED AS REQUIRED BY SMACNA, NFPA, <br />DUCT DETECTORS <br />AS WELL AS ANY OTHER APPLICABLE CODE <br />RE: MECHANICAL DRAWINGS FOR HVAC INFORMATION <br />EMERGENCY GENERATOR <br />NONE REQUIRED. NONE PROVIDED. <br />RE: A101 FOR ROOF FINISH INFO & CODE INFORMATION <br />INTERIOR FINISHES <br />FOR FLAME SPREAD RATINGS <br />SITE PLAN SHOWING ADJACENT <br />RE: OVERALL PROJECT SITE PLAN ON A100. FOR COMPLETE SITE <br />ROADWAYS, BUILDINGS, AND <br />WORK AND UTILITY INFORMATION, RE: CIVIL DRAWINGS BY AVID. <br />FIRE HYDRANTS <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />FIRE ALARM <br />CONTRACTORS SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />FULL SYSTEM PROVIDED. TO BE DESIGNED AND PERMITTED BY <br />SPRINKLERS <br />CONTRACTORS SHOP DRAWINGS. RE: CODE INFORMATION ON A101 <br />GAS USAGE <br />NONE REQUIRED. NONE PROVIDED. <br />tn 'p <br />�0 g <br />0 u <br />� , a <br />4u a' 2 N <br />�•i <br />rA <br />� <br />b� <br />P� o <br />• w O Qo <br />U nw , <br />U �O <br />C4 <br />i <br />W <br />O <br />CL <br />O <br />V Z 00 <br />M <br />�QJ <br />CQC ILL <br />Ewa <br />U <br />Cn <br />0 <br />E <br />E <br />0 <br />U <br />L <br />0- <br />CuCN <br />m <br />W Y <br />M ' <br />W <br />Q� J <br />m <br />CuJLL <br />� �N <br />J <br />J <br />W CU�a/ <br />c 04 <br />DU.)a <br />��N <br />a <br />F <br />,Ail <br />U) <br />0 <br />L <br />W CL <br />W <br />Cn <br />W <br />CL <br />W <br />o_ <br />'u7} <br />cQi <br />J <br />W <br />L0 <br />Q <br />N <br />o <br />US <br />� <br />z <br />o�1 <br />Lu <br />304 <br />ir <br />Q <br />o <br />CD <br />N <br />z <br />q <br />� <br />W <br />a <br />o <br />o <br />U <br />i <br />
The URL can be used to link to this page
Your browser does not support the video tag.