Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY <br />BON <br />TERMINATIOIS <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />upper to lights & outlets <br />Dipper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13, All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFi <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />& <br />THREE-WAY SWITCH <br />�'4 <br />FOUR-WAY SWITCH <br />,pR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUSTFAN <br />;QN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FE9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />FD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />NI] <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />S.D <br />C.M <br />OWNER'S SW� ITE <br />T <br />1 / <br />/ ROUGH -IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE / <br />— i u=I <br />PA LO �� j CAFE <br />I / <br />I <br />I <br />I <br />I <br />i <br />I <br />I ` <br />FAMILY RM <br />I G <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />I LIGHT PRE -WIRE <br />U.C. OUTLET <br />I <br />FOR DW <br />I <br />1 U.C. OUTLET <br />I <br />I <br />GFI I _ <br />GFI C-- - - - - - - - - - GF <br />F- -, <br />- <br />i a <br />D.W. I <br />L - - - J <br />INK / DIS <br />SPECSIPENDANT AS <br />PER <br />II w <br />�I 111 III <br />�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIii111111111111i1111 <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H. <br />IRRIGATION <br />VERIFY LOCATION GFI @ 44" A.F.F. <br />W H ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR 1 <br />GAR. DOOh <br />GFI I <br />GFI @ 44" <br />A.F.F. <br />I <br />I I <br />_ I <br />I 11 I <br />1 <br />I <br />I <br />L------------ <br />GFI @ 44" <br />A.F.F. <br />J11ENTRY <br />I <br />WP j <br />- - - - - S.D. _ S.D. <br />db <br />C.M <br />I <br />OPT. <br />REF- BEDROOM 2 �� / 1 S.D. FI \ <br />BEDRVOOM 3� BEDROOM 4 <br />G�I`� ROUGH -IN FOR <br />OUGH-IN FOR �/ / < — — \ OPT. CLG. FAN/ <br />I OPT. CLG. FAN/ / I � LIGHT PRE -WIRE <br />LIGHT PRE -WIRE * <br />ROUGH -IN FOR I <br />OPT. CLG. FAN/ I <br />/ LIGHT PRE -WIRE I ` <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4'=1'-0" <br />0 <br />N <br />0 <br />N <br />0 <br />CD <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building <br />Code - <br />Residential 6th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />v <br />"rs <br />OCN� <br />Co <br />N <br />FA <br />O <br />#- <br />-,, <br />�IN(D <br />C <br />J _N 5 <br />aLL uJW <br />a <br />aimii <br />rri <br />°'awe <br />Z <br /><'EL�, <br />C) i to <br />mmo <br />W <br />2 E C' <br />0 d <br />3 <br />IL <br />-;9N 0 <br />J <br />Q o D <br />0 <br />Z <br />NQcoZ <br />0 < <br />U <br />U f— -J <br />❑❑❑ <br />W <br />v M <br />z N O <br />W � <br />� N <br />� � <br />z <br />Q M <br />a o <br />E3 <br />_ M <br />W <br />� <br />z <br />a <br />W <br />0 UL <br />t6 <br />V= Y <br />w C <br />t <br />o a+ <br />t/t <br />�� <br />wMill <br />c E <br />N <br />N <br />r— a <br />� <br />U °7 <br />LL, <br />E <br />Uk <br />_ 0 <br />v' <br />U o <br />Q <br />• <br />em <br />r_ <br />�Z <br />W <br />M <br />2 <br />u <br />a E <br />� � <br />y <br />L�z <br />U <br />g <br />> o <br />Q � <br />Z © <br />oa <br />_ <br />o <br />o E <br />�� <br />a <br />�o <br />0 <br />o� <br />aZ <br />,� <br />�J <br />Y <br />U <br />Nm <br />m � <br />o <br />0- <br />"0 <br />ZJ <br />N v <br />7 <br /><w <br />U <br />Q <br />U <br />O¢ <br />ire <br />�Z <br />_0 <br />w <br />a <br />w� <br />0� <br />>° <br />a <br />V <br />z¢ <br />0� <br />�M <br />0 <br />= <br />> d' <br />as <br />0 <br />LO <br />n/ <br />v <br />00 <br />C�� <br />i' <br />C V <br />> <br />O <br />�1 <br />0— <br />0 <br />0 <br />(D <br />^ 1 m <br />W <br />� <br />I" <br />E N <br />r <br />cu p <br />o <br />cu <br />T <br />CY) <br />o <br />Z <br />Z <br />E 0 <br />m <br />co <br />a <br />0 <br />0 _j <br />-ao <br />CD <br />-1 <br />JOB <br />NO: <br />20-3573 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />