My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39700 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39700 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:28:55 PM
Creation date
2/19/2025 4:01:32 PM
Metadata
Fields
Template:
Building Plans
Street #
39700
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
810
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�IWuiWlul���,�► . wlnl�u�Yl�lu�l■i�luul�l■I <br />ATTIC VENTILATION CALCULATIONS - Al (TRA) <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />11150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />—NOTE"' <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />11 D <br />ROOF PLAN - ELEV-Al <br />SCALE: %4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />I Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />e`��011lltl///j•ff <br />O <br />0 <br /><: <br />0. <br />% <br />� �•� <br />CO <br />"fitJ <br />11111 ltt1 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential Bth Edition. Engineers signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />to <br />fly <br />4 <br />�pp <br />—• N 0 �k <br />Q C7 <br />I' <br />C J <br />OM N N C En N LL <br />C <br />i1i <br />M ' <br />LLI <br />7 -1 - u- -JLL a <br />�) <br />a <br />�? ai m w vi <br />�C)'i� aair <br />Z-, <br />CIL <br />ZZ <br />U) 0 <br />cacao mm0 <br />W <br />us <br />E rn a p a <br />a) ..�+ <br />Z <br />C) <br />N Q M Z U J <br />Z <br />�(3 ❑❑❑ <br />W <br />M c <br />z N O <br />0 0 <br />_ <br />z � <br />z <br />J � <br />d N <br />Ln <br />_ M <br />a <br />o <br />-d <br />1 <br />rI <br />.0 <br />W 2 <br />0 <br />o a <br />N <br />W � <br />EcJ'1 <br />U 0° <br />w m <br />I° s <br />0 <br />i <br />S <br />Ili <br />U o T <br />c CD <br />4m, <br />Q o <br />/ <br />14 <br />O <br />co <br />� <br />coZ <br />M <br />z <br />o <br />Z <br />¢ <br />� <br />ILL. <br />E <br />Z O <br />> R <br />W O <br />Z <br />oa <br />�CU <br />X O <br />O¢ <br />O <br />0 U <br />0< <br />O <br />N ro <br />a <br />o <br />w Z. <br />¢ <br />a Z <br />W, <br />d L <br />(O <br />W <br />❑ <br />Y <br />n� <br />M O <br />o <br />W <br />z-Z <br />>Z <br />J <br />`z <br />U3 <br />N <br />a� <br />O ¢ <br />U <br />0-, <br />T y <br />U <br />tt 0 <br />O <br />iW-- <br />2 F <br />J W <br />_ <br />� <br />O <br />O <br />w ; <br />} <br />O <br />�1 <br />zla <br />aX <br />o 3 <br />N <br />E2 <br />nL' <br />CU <br />LO <br />U <br />00 <br />I�. <br />LL <br />( <br />r <br />O <br />O <br />V <br />C.0 <br />m <br />O <br />r <br />c>3 O <br />d- <br />= <br />r <br />O if') <br />Liz <br />r <br />Lo <br />o� z <br />r <br />00 <br />rn LO <br />ui <br />E <br />a <br />Z <br />E C <br />c <br />m <br />d <br />E <br />0 <br />0 J <br />Q <br />CD <br />J <br />JOB <br />NO: <br />20-3573 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.