HEEL <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />12 <br />o 5 <br />F4 <br />T.O.M. — <br />HDR HGT. <br />TEXTURED <br />o CEMENTICIOUS <br />' FINISH ON C.M.U. <br />°O 00 <br />-1 (TYP.) <br />CID <br />12 <br />5� <br />T-0" <br />F.FL. <br />N <br />14'-0" RIDGE VENT <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />1'-0,1 <br />------------------------------- ----—-- — — — — — <br />Mimi INI I—E—IN <br />Mimi ININI 0 <br />FRONT ELEVATION — Al <br />12 <br />�5 <br />SCALE: 1/4"=V-0" <br />15'-0" RIDGE VENT <br />LEFT ELEVATION — Al <br />E: 1 /4"=1 r-0" <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. <br />HDR HGT. <br />6" FASCIA <br />(TYP) <br />TEXTURED _ <br />CEMENTICIOUS a? <br />FINISH ON C.M.U. cD <br />(TYP.) <br />F.FL. <br />A <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />a <br />O <br />0 <br />CO <br />0 W <br />Q .•`' h 0� <br />F <br />` <br />JI <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />Q <br />E n <br />J <br />0 <br />Na aC J LL <br />9GW N 9! LL W <br />tl! <br />dl <br />a <br />r151.-r4.� - w a <br />M a LL d Y <br />� LL U. a U <br />�O <br />_ <br />0: <br />2 cca c <br />�ca Ec�m O <br />W <br />W <br />r9i�OnjO' a ¢ a <br />a <br />Z <br />N M2 �q' to Q <br />Z <br />W <br />OU <br />❑ ❑ ❑ <br />0 <br />z_ 04 <br />z � <br />J <br />�z <br />U <br />O <br />vN <br />u <br />u <br />cb• <br />Cc) <br />M <br />M <br />g <br />aS <br />W <br />z <br />(�E <br />° <br />�£ <br />Z® <br />a� <br />�- � <br />I� U <br />wi <br />'o <br />oa <br />()v <br />ZE <br />C <br />N � <br />az�z <br />o <br />z <br />o <br />l <br />W <br />2 L <br />f0 <br />N C <br />�� <br />0 <br />Zz <br />'<W <br />Z <br />in <br />i7i J <br /><� <br />w <br />iz <br />O <br />W <br />3 <br />� 3 <br />as <br />�w <br />Mill <br />O <br />cozl�d <br />i= <br />8 3 <br />2 O <br />m <br />> I.() <br />O <br />W <br />0 <br />L <br />W <br />T <br />_J <br />N <br />�> <br />A/ <br />LPL <br />Li <br />0 <br />a. <br />U <br />C co <br />T�— <br />it 04 <br />T <br />r <br />T <br />T <br />00 <br />E <br />M <br />z° <br />E O <br />E <br />v w <br />c <br />a <br />0 � <br />Q o <br />� <br />JOB <br />NO: <br />21-1075 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />