My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39850 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39850 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:00:11 AM
Creation date
2/19/2025 4:08:43 PM
Metadata
Fields
Template:
Building Plans
Street #
39850
Location
Dawson Chase Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
21834
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.'.' II�'II I1 IIII!I�1INIIIIIQI! ll�l I II'1 Lill II 1 11 lip 111 11 "_ ll, — 11111, 1 _ _ '_ I_ _. I. _ _ . _ _ _ I IMINT,IF9111"11 1.11' 1.I. 1, <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY4 <br />BON <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Doper to lights & outlets <br />Dpper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FTF <br />WP WEATHERPROOF DUPLEX OUTLET <br />PEF <br />GFI GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />OEJ <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />I—O WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />+PC LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />iO EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />P13 PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />]M ELECTRIC METER <br />WWI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />H.B. <br />qP <br />AC PAD EP)AD <br />DISC.50 <br />' \ <br />o0 <br />WP =8 I <br />GFI I <br />FAMILY R M PENDANT <br />AS 12 PER / <br />--�/ <br />\ ROUGH -IN FOR -,,CAFE <br />/ LIGHT PRE -WIRE \ \ <br />t <br />PATIO1 1 <br />nGFI ri _HGFI _ <br />tOPT. REF. <br />momlwm A roll 7111 <br />-;' op Me1�.1�11� �►Li <br />M■■■■N =_ � <br />l■m■■■i� <br />(GFI L / U.C. SW►TCH <br />I FOR DISPOSAL <br />I DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />j HOOD PER SPECS <br />C.M <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />FLR. <br />J <br />FLEX <br />12 <br />4A <br />/ G � <br />ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />F <br />V <br />[P� ` /GFI @ 44" <br />1 A.F.F. <br />I <br />\ I <br />I <br />2 CAR\GARAG E � <br />I <br />:FI @ 44" I <br />A.F.F. I <br />GARAGE <br />LIGHT AS GFI FOR <br />PER SPECS GAR. DOOR <br />PREWIRE <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />0 <br />D <br />VERIFY LOCATION <br />ELECTRICAL PANEL I GFI @ 44" A.F.F. - <br />c-� IRRIGATION <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />FI <br />ENTRY <br />N R <br />IG AS LS <br />PER SPECS <br />WP I <br />GFI <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />L <br />O <br />CD <br />0 <br />M C, <br />N O <br />00 <br />Z <br />o <br />Z <br />a <br />J M <br />d N <br />M <br />to Z <br />co <br />W p <br />.O <br />o a <br />< <br />— .f <br />u, I <br />N c <br />�N ZD <br />o <br />t�1oo <br />� � 00 <br />o g <br />1 <br />Nick, 0 as <br />m 8 <br />m <br />�m <br />� N <br />Q N o w z <br />� =LL� op uj w <br />� <br />�LU ��z ° a <br />W >g <br />0 <br />Z ��� _° <br />o¢ C <br />t^ C N <br />V 2 Ern RULLS m d <br />IJJ NaM ~ Q <br />0. r-) o <br />rn <br />0 <br />N <br />00 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />O <br />w <br />M <br />CO <br />z <br />Z <br />u <br />E E <br />�Z <br />w <br />� <br />z m <br /><� <br />Z® <br />oa <br />ca <br />00 <br />ca '6 <br />CL <br />x� <br />U <br />O F <br />0U <br />0 < <br />Z <br />O <br />N <br />o <br />ap <br />az <br />, <br />W2 <br />to <br />�eYoZ <br />_ C <br />U <br />o <br />ZF <br />Z <br />CO <br />a � <br />w <br />Zz <br />�3 <br />s <br />s° <br />1,§ <br />aZ <br />npu <br />�k <br />CJW <br /><o <br />0- <br />_� <br />WF <br />o <br />C.0 <br />w�WO <br />>xx <br />a <br />v <br />< <br />°3 <br />0 <br />.N 0 <br />>M <br />L <br />N <br />O <br />0 <br />�C <br />0 <br />N <br />00 <br />0 <br />N p- <br />r <br />OO <br />N= <br />It O <br />N rn N <br />LO <br />r <br />ai <br />CD <br />T r CCIV <br />o <br />m <br />z <br />� 0 v; <br />E 0 y <br />Z <br />m <br />tt1 <br />tl <br />E w <br />U J Q <br />c <br />J <br />JOB <br />NO: 19-5899 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.