Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />200A <br />INDOOR PANEL <br />CENTER <br />NOTES: <br />#74 copper to lights 8 outlets <br />ELECTRICAL CONTRACTOR <br />NEMA t #12 copper to 20 amp ckts <br />200AMP <br />MUST VERIFY WITH THE <br />10 #10-2 popper to WH <br />SPECIFICATIONS FOR THE TYPE <br />#103 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />T <br />LOCATION PURPOSES. <br />MAIN <br />O <br />200 amp <br />2/0 or 4/0 SER Alu <br />IF <br />150 amp <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />A <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />T© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />[� <br />THERMOSTAT <br />I� <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C`!I? <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />----------------------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />- - - - - - - - - - - - - - - - - - - - - - - - - - --------------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />UPPER FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 <br />C1 <br />Co <br />M <br />_ <br />z <br />z <br />M <br />QCD <br />d N <br />E3 <br />- M <br />V} z <br />CZ <br />Vi Y <br />rl.r o <br />o a <br />LU <br />C) N c o <br />U <br />u, <br />8 <br />0all <br />= <br />Ylf. <br />U a <br />Q <br />It <br />N N <br />Z o _ 22. w Z <br />- ` _�, M <br />wI i � � r„GD .o <br />VJ m U P. W <br />Pz <br />=> m LL o N <br />LULUAQ <br />Z 0vvaiwQ p <br />to 9 vN� <br />U) g ErnP3 Q <br />Z <br />LU a NaM Q <br />LL0 <br />rO � j U <br />00 <br />rn <br />0 <br />CV <br />M <br />w <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />r— <br />o <br />w <br />co <br />co <br />J <br />2 <br />oz S <br />z <br />Q <br />� <br />ce E <br />CL o <br />w0 <br />zo <br /><N <br />z® <br />❑a <br />N V141 <br />— E <br />C) <br />to�o <br />o <br />a� <br />° <br />" <br />00 <br />°¢ <br />a z <br />WW <br />C11 <br />Q <br />L <br />to <br />::,r <br />O <br />0 Y <br />°m <br />m o <br />Z' <br />N <br />J <br />7 <br />¢w <br />2m <br />(1)Z <br />3 <br />W <br />0 <br />ZZ <br />g0 <br />W <br />0 <br />a <br />< 0 <br />oE <br />�w <br />=3 <br />� <br />coo <br />oz< <br />l <br />n} o <br />o~ <br />� <br />¢ <br />U'> <br />S2 O <br />0 <br />^L, <br />W <br />N <br />O <br />0 <br />Q <br />C <br />N <br />m <br />N <br />T <br />`-00 <br />O <br />N 0) <br />r— <br />00 <br />It O <br />= N `- <br />T— <br />N <br />ai <br />I-°' <br />T r N <br />d <br />cc <br />O N <br />Z <br />Z <br />c <br />E Q (D <br />E <br />M <br />t° <br />a- <br />o a cc <br />U J Q <br />a0i <br />J <br />JOB <br />NO: 19-5899 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.1 <br />